RESUMEN
OBJECTIVE: In patients with Crohn's disease (CD) on combination therapy (infliximab and immunosuppressant) and stopping infliximab (cohort from the study of infliximab diSconTinuation in CrOhn's disease patients in stable Remission on combined therapy with Immunosuppressors (STORI)), the risk of short-term (≤6 months) and mid/long-term relapse (>6 months) was associated with distinct blood protein profiles. Our aim was to test the external validity of this finding in the SPARE cohort (A proSpective Randomized Controlled Trial comParing infliximAb-antimetabolites Combination Therapy to Anti-metabolites monotheRapy and Infliximab monothErapy in Crohn's Disease Patients in Sustained Steroid-free Remission on Combination Therapy). DESIGN: In SPARE, patients with CD in sustained steroid-free clinical remission and on combination therapy were randomly allocated to three arms: continuing combination therapy, stopping infliximab or stopping immunosuppressant. In the baseline serum of the STORI and SPARE (arm stopping infliximab) cohorts, we studied 202 immune-related proteins. The proteins associated with time to relapse (univariable Cox model) were compared between STORI and SPARE. The discriminative ability of biomarkers (individually and combined in pairs) was evaluated by the c-statistic (concordance analysis) which was compared with C-reactive protein (CRP), faecal calprotectin and a previously validated model (CEASE). RESULTS: In STORI and SPARE, distinct blood protein profiles were associated with the risk of short-term (eg, high level: CRP, haptoglobin, interleukin-6, C-type lectin domain family 4 member C) and mid/long-term relapse (eg, low level: Fms-related tyrosine kinase 3 ligand, kallistatin, fibroblast growth factor 2). At external validation, the top 10 biomarker pairs showed a higher c-statistic than the CEASE model, CRP and faecal calprotectin in predicting short-term (0.76-0.80 vs 0.74 vs 0.71 vs 0.69, respectively) and mid/long-term relapse (0.66-0.68 vs 0.61 vs 0.52 vs 0.59, respectively). CONCLUSION: In patients with CD stopping infliximab, we confirm that the risk of short-term and mid/long-term relapse is associated with distinct blood protein profiles showing the potential to guide infliximab withdrawal. TRIAL REGISTRATION NUMBER: NCT00571337 and NCT02177071.
RESUMEN
Hyperspectral stimulated Raman scattering (SRS) microscopy is a powerful method for direct visualisation and compositional analysis of cellular lipid droplets. Here we report the application of spectral phasor analysis as a convenient method for the segmentation of lipid droplets using the hyperspectral SRS spectrum in the high wavenumber and fingerprint region of the spectrum. Spectral phasor analysis was shown to discriminate six fatty acids based on vibrational spectroscopic features in solution. The methodology was then applied to studying fatty acid metabolism and storage in a mammalian cancer cell model and during drug-induced steatosis in a hepatocellular carcinoma cell model. The accumulation of fatty acids into cellular lipid droplets was shown to vary as a function of the degree of unsaturation, whilst in a model of drug-induced steatosis, the detection of increased saturated fatty acid esters was observed. Taking advantage of the fingerprint and high wavenumber regions of the SRS spectrum has yielded a greater insight into lipid droplet composition in a cellular context. This approach will find application in the label-free profiling of intracellular lipids in complex disease models.
Asunto(s)
Quimiometría , Gotas Lipídicas , Animales , Microscopía Óptica no Lineal , Ácidos Grasos , Microscopía/métodos , Espectrometría Raman/métodos , MamíferosRESUMEN
Over the past decade, the separation efficiency achieved by linear IMS instruments has increased substantially, with state-of-the-art IM technologies, such as the trapped ion mobility (TIMS), the cyclic traveling wave ion mobility (cTWIMS), and the structure for lossless ion manipulation (SLIM) platforms commonly demonstrating resolving powers in excess of 200. However, for complex sample analysis that require front end separation, the achievement of such high resolving power in TIMS is significantly hampered, since the ion mobility range must be broad enough to analyze all the classes of compounds of interest, whereas the IM analysis time must be short enough to cope with the time scale of the preseparation technique employed. In this paper, we introduce the concept of sliding windows in ion mobility (SWIM) for chromatography hyphenated TIMS applications that bypasses the need to use a wide and fixed IM range by using instead narrow and mobile ion mobility windows that adapt to the analytes' ion mobility during chromatographic separation. GC-TIMS-MS analysis of a mixture of 174 standards from several halogenated persistent organic pollutant (POP) classes, including chlorinated and brominated dioxins, biphenyls, and PBDEs, demonstrated that the average IM resolving power could be increased up to 40% when the SWIM mode was used, thereby greatly increasing the method selectivity for the analysis of complex samples.
RESUMEN
In the last decades, surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) has attracted increasing interest due to its unique capabilities, achievable through the nanostructured substrates used to promote the analyte desorption/ionization. While the most widely recognized asset of SALDI-MS is the untargeted analysis of small molecules, this technique also offers the possibility of targeted approaches. In particular, the implementation of SALDI-MS imaging (SALDI-MSI), which is the focus of this review, opens up new opportunities. After a brief discussion of the nomenclature and the fundamental mechanisms associated with this technique, which are still highly controversial, the analytical strategies to perform SALDI-MSI are extensively discussed. Emphasis is placed on the sample preparation but also on the selection of the nanosubstrate (in terms of chemical composition and morphology) as well as its functionalization possibilities for the selective analysis of specific compounds in targeted approaches. Subsequently, some selected applications of SALDI-MSI in various fields (i.e., biomedical, biological, environmental, and forensic) are presented. The strengths and the remaining limitations of SALDI-MSI are finally summarized in the conclusion and some perspectives of this technique, which has a bright future, are proposed in this section.
Asunto(s)
Medicina Legal , Rayos Láser , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodosRESUMEN
MALDI mass spectrometry imaging (MALDI MSI) is a powerful analytical method for achieving 2D localization of compounds from thin sections of typically but not exclusively biological samples. The dynamically harmonized ICR cell (ParaCell) was recently introduced to achieve extreme spectral resolution capable of providing the isotopic fine structure of ions detected in complex samples. The latest improvement in the ICR technology also includes 2ω detection, which significantly reduces the transient time while preserving the nominal mass resolving power of the ICR cell. High-resolution MS images acquired on FT-ICR instruments equipped with 7T and 9.4T superconducting magnets and the dynamically harmonized ICR cell operating at suboptimal parameters suffered severely from the pixel-to-pixel shifting of m/z peaks due to space-charge effects. The resulting profile average mass spectra have depreciated mass measurement accuracy and mass resolving power under the instrument specifications that affect the confidence level of the identified ions. Here, we propose an analytical workflow based on the monitoring of the total ion current to restrain the pixel-to-pixel m/z shift. Adjustment of the laser parameters is proposed to maintain high spectral resolution and mass accuracy measurement within the instrument specifications during MSI analyses. The optimized method has been successfully employed in replicates to perform high-quality MALDI MS images at resolving power (FWHM) above 1,000,000 in the lipid mass range across the whole image for superconducting magnets of 7T and 9.4T using 1 and 2ω detection. Our data also compare favorably with MALDI MSI experiments performed on higher-magnetic-field superconducting magnets, including the 21T MALDI FT-ICR prototype instrument of the NHMFL group at Tallahassee, Florida.
Asunto(s)
Ciclotrones , Diagnóstico por Imagen , Análisis de Fourier , Iones , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodosRESUMEN
Folate receptor α (FRα) is a high affinity folate membrane receptor that is overexpressed in a wide variety of cancers. Detecting the overexpression of this receptor is important for cancer cells identification and to potentially guide the choice of treatment since several FRα-targeted drugs are currently in clinical trials. In this work, we built SERS nanotags based on core@shell Au@Ag nanoparticles labelled with resonant Raman-reporter and functionalised with a thiolated PEG linker bearing folic acid at the chain end. Using SERS mapping on single cells, we showed that the nanotags (FR-nanotags) could specifically target FRα on overexpressing HeLa cells and could measure the gradual blocking of FRα by free folic acid introduced in the media along the nanotags. With a control nanotag, we showed that the SERS response was 10-fold higher on HeLa cells when folic acid is present on the PEG linker compared to PEG chains without folic acid. Non-specific binding of the FR-nanotags was demonstrated to be low and mainly caused by the folic acid molecule at the PEG chain end. When comparing cancer cells with different expression levels of FRα, we obtained 4-fold higher SERS response on overexpressing HeLa cells compared to non-overexpressing A549 cells, allowing the discrimination of both cell lines with a high contrast. Owing to the biocompatibility of the developed nanotags, we demonstrated that measurements of FRα on live HeLa cells were also possible and gave similar results to measurements on fixed cells, indicating the versatility of the developed nanotags for detecting FRα under various experimental conditions.
Asunto(s)
Receptor 1 de Folato , Nanopartículas del Metal , Receptor 1 de Folato/metabolismo , Ácido Fólico/química , Células HeLa , Humanos , Nanopartículas del Metal/química , Plata/químicaRESUMEN
Stomatopoda is a crustacean order including sophisticated predators called spearing and smashing mantis shrimps that are separated from the well-studied Eumalacotraca since the Devonian. The spearing mantis shrimp has developed a spiky dactyl capable of impaling fishes or crustaceans in a fraction of second. In this high velocity hunting technique, the spikes undergo an intense mechanical constraint to which their exoskeleton (or cuticle) has to be adapted. To better understand the spike cuticle internal architecture and composition, electron microscopy, X-ray microanalysis and Raman spectroscopy were used on the spikes of 7 individuals (collected in French Polynesia and Indonesia), but also on parts of the body cuticle that have less mechanical stress to bear. In the body cuticle, several specificities linked to the group were found, allowing to determine the basic structure from which the spike cuticle has evolved. Results also highlighted that the body cuticle of mantis shrimps could be a model close to the ancestral arthropod cuticle by the aspect of its biological layers (epi- and procuticle including exo- and endocuticle) as well as by the Ca-carbonate/phosphate mineral content of these layers. In contrast, the spike cuticle exhibits a deeply modified organization in four functional regions overprinted on the biological layers. Each of them has specific fibre arrangement or mineral content (fluorapatite, ACP or phosphate-rich Ca-carbonate) and is thought to assume specific mechanical roles, conferring appropriate properties on the entire spike. These results agree with an evolution of smashing mantis shrimps from primitive stabbing/spearing shrimps, and thus also allowed a better understanding of the structural modifications described in previous studies on the dactyl club of smashing mantis shrimps.
Asunto(s)
Estructuras Animales/metabolismo , Biomineralización/fisiología , Crustáceos/metabolismo , Minerales/metabolismo , Estructuras Animales/química , Estructuras Animales/ultraestructura , Animales , Carbonato de Calcio/metabolismo , Fosfatos de Calcio/metabolismo , Crustáceos/química , Crustáceos/ultraestructura , Decápodos/química , Decápodos/metabolismo , Decápodos/ultraestructura , Microanálisis por Sonda Electrónica/métodos , Microscopía Electrónica de Rastreo/métodos , Microscopía Electrónica de Transmisión/métodos , Conducta Predatoria/fisiología , Espectrometría por Rayos X/métodos , Espectrometría Raman/métodosRESUMEN
Mass spectrometry imaging (MSI) is a powerful and convenient method for revealing the spatial chemical composition of different biological samples. Molecular annotation of the detected signals is only possible if a high mass accuracy is maintained over the entire image and the m/z range. However, the change in the number of ions from pixel-to-pixel of the biological samples could lead to small fluctuations in the detected m/z-values, called mass shift. The use of internal calibration is known to offer the best solution to avoid, or at least to reduce, mass shifts. Their "a priori" selection for a global MSI acquisition is prone to false positive detection and therefore to poor recalibration. To fill this gap, this work describes an algorithm that recalibrates each spectrum individually by estimating its mass shift with the help of a list of pixel-specific internal calibrating ions, automatically generated in a data-adaptive manner (https://github.com/LaRoccaRaphael/MSI_recalibration). Through a practical example, we applied the methodology to a zebrafish whole-body section acquired at a high mass resolution to demonstrate the impact of mass shift on data analysis and the capability of our algorithm to recalibrate MSI data. In addition, we illustrate the broad applicability of the method by recalibrating 31 different public MSI data sets from METASPACE from various samples and types of MSI and show that our recalibration significantly increases the numbers of METASPACE annotations (gaining from 20 up to 400 additional annotations), particularly the high-confidence annotations with a low false discovery rate.
Asunto(s)
Técnicas Histológicas , Pez Cebra , Animales , Calibración , Iones , Espectrometría de Masa por Láser de Matriz Asistida de Ionización DesorciónRESUMEN
Lipids are biomolecules of crucial importance involved in critical biological functions. Yet, lipid content determination using mass spectrometry is still challenging due to their rich structural diversity. Preferential ionisation of the different lipid species in the positive or negative polarity is common, especially when using soft ionisation mass spectrometry techniques. Here, we demonstrate the potency of a dual-polarity approach using surface-assisted laser desorption/ionisation coupled to Fourier transform-ion cyclotron resonance (SALDI FT-ICR) mass spectrometry imaging (MSI) combined with Kendrick mass defect data filtering to (i) identify the lipids detected in both polarities from the same tissue section and (ii) show the complementarity of the dual-polarity data, both regarding the lipid coverage and the spatial distributions of the various lipids. For this purpose, we imaged the same mouse brain section in the positive and negative ionisation modes, on alternate pixels, in a SALDI FT-ICR MS imaging approach using gold nanoparticles (AuNPs) as dual-polarity nanosubstrates. Our study demonstrates, for the first time, the feasibility of (i) a dual-polarity SALDI-MSI approach on the same tissue section, (ii) using AuNPs as nanosubstrates combined with a FT-ICR mass analyser and (iii) the Kendrick mass defect data filtering applied to SALDI-MSI data. In particular, we show the complementarity in the lipids detected both in a given ionisation mode and in the two different ionisation modes. Graphical abstract.
Asunto(s)
Química Encefálica , Lípidos/análisis , Animales , Análisis de Fourier , Oro/química , Espectrometría de Masas/métodos , Nanopartículas del Metal/química , RatonesRESUMEN
MALDI mass spectrometry imaging (MSI) allows the mapping and the tentative identification of compounds based on their m/z value. In typical MSI, a spectrum is taken at incremental 2D coordinates (pixels) across a sample surface. Single pixel mass spectra show the resolving power of the mass analyzer. Mass shift, i.e., variations of the m/z of the same ion(s), may occur from one pixel to another. The superposition of shifted masses from individual pixels peaks apparently degrades the resolution and the mass accuracy in the average spectrum. This leads to low confidence annotations and biased localization in the image. Besides the intrinsic performances of the analyzer, the sample properties (local composition, thickness, matrix deposition) and the calibration method are sources of mass shift. Here, we report a critical analysis and recommendations to mitigate these sources of mass shift. Mass shift 2D distributions were mapped to illustrate its effect and explore systematically its origin. Adapting the sample preparation, carefully selecting the data acquisition settings, and wisely applying post-processing methods (i.e., m/z realignment or individual m/z recalibration pixel by pixel) are key factors to lower the mass shift and to improve image quality and annotations. A recommended workflow, resulting from a comprehensive analysis, was successfully applied to several complex samples acquired on both MALDI ToF and MALDI FT-ICR instruments.
RESUMEN
Mass spectrometry imaging (MSI) has become a powerful method for mapping metabolite distribution in a tissue. Applied to bacterial colonies, MSI has a bright future, both for the discovery of new bioactive compounds and for a better understanding of bacterial antibiotic resistance mechanisms. Coupled with separation techniques such as ion mobility mass spectrometry (IM-MS), the identification of metabolites directly on the image is now possible and does not require additional analysis such as HPLC-MS/MS. In this article, we propose to apply a semi-targeted workflow for rapid IM-MSI data analysis focused on the search for bioactive compounds. First, chemically-related compounds showing a repetitive mass unit (i.e. lipids and lipopeptides) were targeted based on the Kendrick mass defect analysis. The detected groups of potentially bioactive compounds were then confirmed by fitting their measured ion moibilites to their measured m/z values. Using both their m/z and ion mobility values, the selected groups of compounds were identified using the available databases and finally their distribution was observed on the image. Using this workflow on a co-culture of bacteria, we were able to detect and localize bioactive compounds involved in the microbial interaction.
Asunto(s)
Lipopéptidos , Espectrometría de Masas en Tándem , Cromatografía Líquida de Alta Presión , Espectrometría de Masa por Láser de Matriz Asistida de Ionización DesorciónRESUMEN
Highly selective nanoprobes have been developed based on SERS-active Au@Ag nanoparticles protected by a PEG coating and functionalized with monoclonal antibodies against human epidermal growth factor receptor 2 (HER2). The PEG coating allows to drastically reduce unspecific interactions during incubation on tissues, while the monoclonal antibodies allow a highly specific targeting of HER2. Using the designed SERS nanoprobes combined with a spectral imaging and data weighting approach, we demonstrate the proportionality between the SERS signal and the amount of HER2 antigen on the cell membranes as measured by digital image analysis of IHC staining in microscopic breast tumors (linear fit R2 = 0.87). We also show that the level of expression of HER2 measured by SERS is significantly different between several microscopic tumor parts of the same tissue slide. Therefore, SERS is proving to be a suitable technique for the localized quantitative measurement of specific markers in breast cancerous tissues. Owing to its high multiplexing capabilities, SERS could be a future tool of choice for characterizing the molecular heterogeneity of tumors at the microscopic scale.
Asunto(s)
Biomarcadores de Tumor/metabolismo , Neoplasias de la Mama/diagnóstico , Nanopartículas del Metal/química , Receptor ErbB-2/metabolismo , Espectrometría Raman/métodos , Neoplasias de la Mama/genética , Femenino , HumanosRESUMEN
In this work, the multilayer of the surface plasmon resonance (SPR) sensor was optimized to achieve the maximum sensor sensitivity. By optimizing the thickness of the silver layer (Ag) and dielectric films (TiO2 and AlAs), the optimum sensitivity of the SPR sensor could be obtained. The performance of the SPR sensor proposed was compared with control simulations utilizing zinc oxide (ZnO) and molybdenum oxide (MoO3). The numerical results indicate that the figure-of-merits (FOM) of the SPR sensor was achieved around 150/RIU, corresponding to the sensor sensitivity of 162.79°/RIU with the optimized thicknesses of the TiO2, Ag, and AlAs layers of 140 nm, 60 nm, and 25 nm, respectively. This refractive index sensor shows the FOM to have high detection accuracy and high sensitivity that lead to finding potential application in bio-chemical detection with a small volume of liquid used in biological diagnosis.
Asunto(s)
Refractometría , Óxido de Zinc , Plata , Resonancia por Plasmón de SuperficieRESUMEN
The potential of eccrine sweat as a bio-fluid of interest for diagnosis and personalized therapy has not yet been fully evaluated, due to the lack of in-depth sweat characterization studies. Thanks to recent developments in omics, together with the availability of accredited sweat collection methods, the analysis of human sweat may now be envisioned as a standardized, non-invasive test for individualized monitoring and personalized medicine. Here, we characterized individual sweat samples, collected from 28 healthy adult volunteers under the most standardized sampling methodology, by applying optimized shotgun proteomics. The thorough characterization of the sweat proteome allowed the identification of 983 unique proteins from which 344 were identified across all samples. Annotation-wise, the study of the sweat proteome unveiled the over-representation of newly addressed actin dynamics, oxidative stress and proteasome-related functions, in addition to well-described proteolysis and anti-microbial immunity. The sweat proteome composition correlated with the inter-individual variability of sweat secretion parameters. In addition, both gender-exclusive proteins and gender-specific protein abundances were highlighted, despite the high similarity between human female and male sweat proteomes. In conclusion, standardized sample collection coupled with optimized shotgun proteomics significantly improved the depth of sweat proteome coverage, far beyond previous similar studies. The identified proteins were involved in many diverse biological processes and molecular functions, indicating the potential of this bio-fluid as a valuable biological matrix for further studies. Addressing sweat variability, our results prove the proteomic profiling of sweat to be a promising bio-fluid analysis for individualized, non-invasive monitoring and personalized medicine.
Asunto(s)
Glándulas Ecrinas/metabolismo , Proteoma/análisis , Proteoma/metabolismo , Proteómica/métodos , Sudor/química , Sudor/metabolismo , Adulto , Anciano , Niño , Preescolar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Manejo de Especímenes , Adulto JovenRESUMEN
The digital revolution sets a milestone in the progressive miniaturization of working devices and in the underlying advent of molecular machines. Foldamers involving mechanically entangled components with modular secondary structures are among the most promising designs for molecular switch-based applications. Characterizing the nature and dynamics of their intramolecular network following the application of a stimulus is the key to their performance. Here, we use non-dissociative electron transfer as a reductive stimulus in the gas phase and probe the consecutive co-conformational transitions of a donor-acceptor oligorotaxane foldamer using electrospray mass spectrometry interfaced with ion mobility and infrared ion spectroscopy. A comparison of collision cross section distributions for analogous closed-shell and radical molecular ions sheds light on their respective formation energetics, while variations in their respective infrared absorption bands evidence changes in intramolecular organization as the foldamer becomes more compact. These differences are compatible with the advent of radical-pairing interactions.
RESUMEN
In any vertebrate group, tooth shape is known to fit with a biological function related to diet. However, little is known about the relationships between diet and tooth microstructure and composition in teleost fishes. In this work, we describe the external morphology, internal microstructure and elemental composition of the oral teeth of three representative species of the family Serrasalmidae having different feeding habits (herbivorous vs. omnivorous vs. carnivorous). We used backscattered-electron imaging and low vacuum environmental scanning electron microscope to compare the organization and mineralization of tooth layers as well as energy dispersive X-ray microanalysis and Raman microspectrometry to investigate the elemental composition, Ca/P ratio and mineralogy of the most superficial layers. Oral teeth of each serrasalmid species have the same internal organization based on five distinctive layers (i.e. pulp, dentine, inner enameloid, outer enameloid and cuticle) but the general tooth morphology is different according to diet. Microstructural and compositional variation of the cuticle and iron-enrichment of superficial layers were highlighted between herbivorous and carnivorous species. Iron is more concentrated in teeth of the herbivorous species where it is associated with a thicker cuticle explaining the more intense red-pigmentation of the cutting edges of oral teeth. The iron-enrichment is interpreted as a substitution of Ca by Fe in the hydroxyapatite. These traits are discussed in the light of the evolutionary history of the family. Further considerations and hypotheses about the formation and origin of the mineralized tooth layers and especially the iron-rich superficial layers in teleost fishes are suggested.
Asunto(s)
Characiformes/metabolismo , Diente/metabolismo , Animales , Evolución Biológica , Hierro/metabolismo , Espectrometría por Rayos X , Espectrometría RamanRESUMEN
Modern ion mobility instrumentation is typically operated above the low field limit, which may activate the ions and cause structural rearrangement or fragmentation during analysis. Here, we quantitatively assessed the internal heating experienced by ions during trapped ion mobility spectrometry (TIMS) experiments. To this end, the fragmentation yields of fragile benzylpyridinium "thermometer" ions were monitored during both the accumulation and analysis steps inside the TIMS tunnel. The corresponding fragmentation rate constants were translated into a vibrational effective temperature Teff,vib. Our results demonstrate significant fragmentation upstream and inside the TIMS tunnel that corresponds to Teff,vib ≈ 510 K during both the accumulation and analysis steps. Broadening our scope to cytochrome c and lysozyme, we showed that although compact "native" folds can be preserved, the collision cross section distributions are highly sensitive to the transmission voltages and the analysis time scale. Our results are discussed with regard to Teff,vib data previously acquired on traveling-wave (TWIMS) ion mobility in the context of native mass spectrometry and conformational landscape exploration.
RESUMEN
The variable configuration of Raman spectroscopic platforms is one of the major obstacles in establishing Raman spectroscopy as a valuable physicochemical method within real-world scenarios such as clinical diagnostics. For such real world applications like diagnostic classification, the models should ideally be usable to predict data from different setups. Whether it is done by training a rugged model with data from many setups or by a primary-replica strategy where models are developed on a 'primary' setup and the test data are generated on 'replicate' setups, this is only possible if the Raman spectra from different setups are consistent, reproducible, and comparable. However, Raman spectra can be highly sensitive to the measurement conditions, and they change from setup to setup even if the same samples are measured. Although increasingly recognized as an issue, the dependence of the Raman spectra on the instrumental configuration is far from being fully understood and great effort is needed to address the resulting spectral variations and to correct for them. To make the severity of the situation clear, we present a round robin experiment investigating the comparability of 35 Raman spectroscopic devices with different configurations in 15 institutes within seven European countries from the COST (European Cooperation in Science and Technology) action Raman4clinics. The experiment was developed in a fashion that allows various instrumental configurations ranging from highly confocal setups to fibre-optic based systems with different excitation wavelengths. We illustrate the spectral variations caused by the instrumental configurations from the perspectives of peak shifts, intensity variations, peak widths, and noise levels. We conclude this contribution with recommendations that may help to improve the inter-laboratory studies.
RESUMEN
Surface-enhanced Raman scattering (SERS) is a powerful and sensitive technique for the detection of fingerprint signals of molecules and for the investigation of a series of surface chemical reactions. Many studies introduced quantitative applications of SERS in various fields, and several SERS methods have been implemented for each specific application, ranging in performance characteristics, analytes used, instruments, and analytical matrices. In general, very few methods have been validated according to international guidelines. As a consequence, the application of SERS in highly regulated environments is still considered risky, and the perception of a poorly reproducible and insufficiently robust analytical technique has persistently retarded its routine implementation. Collaborative trials are a type of interlaboratory study (ILS) frequently performed to ascertain the quality of a single analytical method. The idea of an ILS of quantification with SERS arose within the framework of Working Group 1 (WG1) of the EU COST Action BM1401 Raman4Clinics in an effort to overcome the problematic perception of quantitative SERS methods. Here, we report the first interlaboratory SERS study ever conducted, involving 15 laboratories and 44 researchers. In this study, we tried to define a methodology to assess the reproducibility and trueness of a quantitative SERS method and to compare different methods. In our opinion, this is a first important step toward a "standardization" process of SERS protocols, not proposed by a single laboratory but by a larger community.
RESUMEN
Surface-enhanced Raman scattering (SERS) nanoprobes based on Au@Ag core@shell nanoparticles coated with poly(allylamine) were functionalized with small targeting molecules to evaluate simultaneously the level of expression of two cancer-related markers, both in cells and in tissues. The Au@Ag nanoparticles provide a high SERS signal enhancement in the visible range when combined with resonant Raman-active molecules. The poly(allylamine) coating plays a dual key role in (i) protecting the metal surface against the complex biological medium, leading to a stable signal of the Raman-active molecules, and (ii) enabling specific biofunctionalization through its amine functions. Using small targeting molecules linked to the polymer coating, two different nanoprobes (duplex approach) were designed. Each was able to specifically target a particular cancer-related marker: folate receptors (FRs) and sialic acid (SA). We demonstrate that the level of expression of these targeted markers can be evaluated following the SERS signal of the probes incubated on cells or tissues. The potential overexpression of folate receptors and of sialic acid was evaluated and measured in breast and ovarian cancerous tissue sections. In addition, FR and/or SA overexpression in the tumor region can be visualized with high contrast with respect to the healthy region and with high spatial accuracy consistent with histology by SERS imaging of the nanoprobe signal. Owing to the unique spectral signature of the designed nanoprobes, this approach offers an efficient tool for the spatially resolved, in situ measurement of the expression level of several cancer-related markers in tumors at the same time.Graphical abstract.