Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Science ; 178(4059): 396-8, 1972 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-17815361

RESUMEN

Very-long-baseline interferometry experiments, involving observations of extragalactic radio sources, were performed in 1969 to determine the vector separations between antenna sites in Massachusetts and West Virginia. The 845.130-kilometer baseline was estimated from two separate experiments. The results agreed with each other to within 2 meters in all three components and with a special geodetic survey to within 2 meters in length; the differences in baseline direction as determined by the survey and by interferometry corresponded to discrepancies of about 5 meters. The experiments also yielded positions for nine extragalactic radio sources, most to within 1 arc second, and allowed the hydrogen maser clocks at the two sites to be synchronized a posteriori with an uncertainty of only a few nanoseconds.

2.
Science ; 178(4059): 407-9, 1972 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-17815365

RESUMEN

Very-long-baseline interferometric observations of radio signals from the TACSAT synchronous satellite, even though extending over only 7 hours, have enabled an excellent orbit to be deduced. Precision in differenced delay and delay-rate measurements reached 0.15 nanosecond ( approximately 5 centimeters in equivalent differenced distance) and 0.05 picosecond per second ( approximately 0.002 centimeter per second in equivalent differenced velocity), respectively. The results from this initial three-station experiment demonstrate the feasibility of using the method for accurate satellite tracking and for geodesy. Comparisons are made with other techniques.

3.
Pediatr Dent ; 17(3): 204-6, 1995.
Artículo en Inglés | MEDLINE | ID: mdl-7617496

RESUMEN

The adhesive monomer, Clearfil New Bond, was used to enhance the bond strength between orthodontic brackets and primary molars, premolars, and NiCr crowns. Twenty specimens of each had this dental adhesive applied according to the manufacturer's instructions in addition to a chemically cured composite material. The remaining specimens (20 each) were bonded without the adhesive monomer. Shear bond strengths were determined using a universal testing machine. Fracture sites were examined to determine the type of bond failure. All bond strengths were significantly increased with the addition of Clearfil New Bond (P < or = 0.0001). The shear bond strength to NiCr crowns with the addition of the adhesive monomer was 7.76 kg. This is comparable to the shear bond strength observed for primary molars (8.66 kg) and premolars (8.65 kg) without adhesive monomer. The observed decrease in adhesive bond failures with the addition of Clearfil New Bond indicated a stronger shear bond strength between the tooth surface and the bracket base. Clearfil New Bond can significantly increase the shear bond strength of orthodontic brackets to both primary molars and premolars. Additionally, it was shown that orthodontic brackets can be successfully bonded to Ni-Cr crowns at strengths comparable to primary or permanent enamel.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios/química , Soportes Ortodóncicos , Cementos de Resina , Análisis de Varianza , Aleaciones de Cromo , Coronas , Humanos , Ensayo de Materiales , Acero Inoxidable , Resistencia a la Tracción , Diente Primario
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda