RESUMEN
Blood-based kinetic analysis of PET data relies on an accurate estimate of the arterial plasma input function (PIF). An alternative to invasive measurements from arterial sampling is an image-derived input function (IDIF). However, an IDIF provides the whole blood radioactivity concentration, rather than the required free tracer radioactivity concentration in plasma. To estimate the tracer PIF, we corrected an IDIF from the carotid artery with estimates of plasma parent fraction (PF) and plasma-to-whole blood (PWB) ratio obtained from five venous samples. We compared the combined IDIF+venous approach to gold standard data from arterial sampling in 10 healthy volunteers undergoing [18F]GE-179 brain PET imaging of the NMDA receptor. Arterial and venous PF and PWB ratio estimates determined from 7 patients with traumatic brain injury (TBI) were also compared to assess the potential effect of medication. There was high agreement between areas under the curves of the estimates of PF (r = 0.99, p<0.001), PWB ratio (r = 0.93, p<0.001), and the PIF (r = 0.92, p<0.001) as well as total distribution volume (VT) in 11 regions across the brain (r = 0.95, p<0.001). IDIF+venous VT had a mean bias of -1.7% and a comparable regional coefficient of variation (arterial: 21.3 ± 2.5%, IDIF+venous: 21.5 ± 2.0%). Simplification of the IDIF+venous method to use only one venous sample provided less accurate VT estimates (mean bias 9.9%; r = 0.71, p<0.001). A version of the method that avoids the need for blood sampling by combining the IDIF with population-based PF and PWB ratio estimates systematically underestimated VT (mean bias -20.9%), and produced VT estimates with a poor correlation to those obtained using arterial data (r = 0.45, p<0.001). Arterial and venous blood data from 7 TBI patients showed high correlations for PF (r = 0.92, p = 0.003) and PWB ratio (r = 0.93, p = 0.003). In conclusion, the IDIF+venous method with five venous samples provides a viable alternative to arterial sampling for quantification of [18F]GE-179 VT.
Asunto(s)
Lesiones Traumáticas del Encéfalo/metabolismo , Neuroimagen/normas , Tomografía de Emisión de Positrones/normas , Radiofármacos/farmacocinética , Receptores de N-Metil-D-Aspartato/metabolismo , Adulto , Lesiones Traumáticas del Encéfalo/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neuroimagen/métodos , Tomografía de Emisión de Positrones/métodos , Reproducibilidad de los Resultados , VenasRESUMEN
Single-photon emission computed tomography (SPECT) systems with pinhole collimators are becoming increasingly important in clinical and preclinical nuclear medicine investigations as they can provide a superior resolution-sensitivity trade-off compared to conventional parallel-hole and fanbeam collimators. Previously, open-source software did not exist for reconstructing tomographic images from pinhole-SPECT datasets. A 3D SPECT system matrix modelling library specific for pinhole collimators has recently been integrated into STIR, an open-source software package for tomographic image reconstruction. The pinhole-SPECT library enables corrections for attenuation and the spatially variant collimator-detector response by incorporating their effects into the system matrix. Attenuation correction can be calculated with a simple single line of response or a full model. The spatially variant collimator-detector response can be modelled with a point spread function and depth of interaction corrections for increased system matrix accuracy. In addition, improvements to computational speed and memory requirements can be made with image masking. This work demonstrates the flexibility and accuracy of STIR's support for pinhole-SPECT datasets using measured and simulated single-pinhole SPECT data from which reconstructed images were analysed quantitatively and qualitatively. The extension of the open-source STIR project with advanced pinhole-SPECT modelling will enable the research community to study the impact of pinhole collimators in several SPECT imaging scenarios and with different scanners.
RESUMEN
INTRODUCTION: The Centiloid scale aims to harmonize amyloid beta (Aß) positron emission tomography (PET) measures across different analysis methods. As Centiloids were created using PET/computerized tomography (CT) data and are influenced by scanner differences, we investigated the Centiloid transformation with data from Insight 46 acquired with PET/magnetic resonanceimaging (MRI). METHODS: We transformed standardized uptake value ratios (SUVRs) from 432 florbetapir PET/MRI scans processed using whole cerebellum (WC) and white matter (WM) references, with and without partial volume correction. Gaussian-mixture-modelling-derived cutpoints for Aß PET positivity were converted. RESULTS: The Centiloid cutpoint was 14.2 for WC SUVRs. The relationship between WM and WC uptake differed between the calibration and testing datasets, producing implausibly low WM-based Centiloids. Linear adjustment produced a WM-based cutpoint of 18.1. DISCUSSION: Transformation of PET/MRI florbetapir data to Centiloids is valid. However, further understanding of the effects of acquisition or biological factors on the transformation using a WM reference is needed. HIGHLIGHTS: Centiloid conversion of amyloid beta positron emission tomography (PET) data aims to standardize results.Centiloid values can be influenced by differences in acquisition.We converted florbetapir PET/magnetic resonance imaging data from a large birth cohort.Whole cerebellum referenced values could be reliably transformed to Centiloids.White matter referenced values may be less generalizable between datasets.
RESUMEN
BACKGROUND: Currently, there is no consensus on the optimal partial volume correction (PVC) algorithm for oncology imaging. Several existing PVC methods require knowledge of the reconstructed resolution, usually as the point spread function (PSF)-often assumed to be spatially invariant. However, this is not the case for SPECT imaging. This work aimed to assess the accuracy of SPECT quantification when PVC is applied using a case-specific PSF. METHODS: Simulations of SPECT [Formula: see text]Tc imaging were performed for a range of activity distributions, including those replicating typical clinical oncology studies. Gaussian PSFs in reconstructed images were estimated using perturbation with a small point source. Estimates of the PSF were made in situations which could be encountered in a patient study, including; different positions in the field of view, different lesion shapes, sizes and contrasts, noise-free and noisy data. Ground truth images were convolved with the perturbation-estimated PSF, and with a PSF reflecting the resolution at the centre of the field of view. Both were compared with reconstructed images and the root-mean-square error calculated to assess the accuracy of the estimated PSF. PVC was applied using Single Target Correction, incorporating the perturbation-estimated PSF. Corrected regional mean values were assessed for quantitative accuracy. RESULTS: Perturbation-estimated PSF values demonstrated dependence on the position in the Field of View and the number of OSEM iterations. A lower root mean squared error was observed when convolution of the ground truth image was performed with the perturbation-estimated PSF, compared with convolution using a different PSF. Regional mean values following PVC using the perturbation-estimated PSF were more accurate than uncorrected data, or data corrected with PVC using an unsuitable PSF. This was the case for both simple and anthropomorphic phantoms. For the simple phantom, regional mean values were within 0.7% of the ground truth values. Accuracy improved after 5 or more OSEM iterations (10 subsets). For the anthropomorphic phantoms, post-correction regional mean values were within 1.6% of the ground truth values for noise-free uniform lesions. CONCLUSION: Perturbation using a simulated point source could potentially improve quantitative SPECT accuracy via the application of PVC, provided that sufficient reconstruction iterations are used.
RESUMEN
PURPOSE: It has recently been recognized that PET/CT may play a role in diffuse parenchymal lung disease. However, interpretation can be confounded due to the variability in lung density both within and between individuals. To address this issue a novel correction method is proposed. METHODS: A CT scan acquired during shallow breathing is registered to a PET study and smoothed so as to match the PET resolution. This is used to derive voxel-based tissue fraction correction factors for the individual. The method was evaluated in a lung phantom study in which the lung was simulated by a Styrofoam/water mixture. The method was further evaluated using (18)F-FDG in 12 subjects free from pulmonary disease where ranges before and after correction were considered. RESULTS: Correction resulted in similar activity concentrations for the lung and background regions, consistent with the experimental phantom set-up. Correction resulted in reduced inter- and intrasubject variability in the estimated SUV. The possible application of the method was further demonstrated in five subjects with interstitial lung changes where increased SUV was demonstrated. Single study pre- and post-treatment studies were also analysed to further illustrate the utility of the method. CONCLUSION: The proposed tissue fraction correction method is a promising technique to account for variability of density in interpreting lung PET studies.
Asunto(s)
Artefactos , Densitometría/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Pulmón/diagnóstico por imagen , Modelos Biológicos , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Simulación por Computador , Femenino , Humanos , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
PURPOSE: Alzheimer's disease (AD) is the most common form of dementia. Clinically, it is characterized by progressive cognitive and functional impairment with structural hallmarks of cortical atrophy and ventricular expansion. Amyloid plaque aggregation is also known to occur in AD subjects. In-vivo imaging of amyloid plaques is now possible with positron emission tomography (PET) radioligands. PET imaging suffers from a degrading phenomenon known as the partial volume effect (PVE). The quantitative accuracy of PET images is reduced by PVEs primarily due to the limited spatial resolution of the scanner. The degree of PVE is influenced by structure size, with smaller structures tending to suffer from more severe PVEs such as atrophied grey matter regions. The aims of this paper were to investigate the effect of partial volume correction (PVC) on the quantification of amyloid PET and to highlight the importance of selecting an appropriate PVC technique. METHODS: An improved PVC technique, region-based voxel-wise (RBV) correction, was compared against existing Van-Cittert (VC) and Müller-Gärtner (MG) methods using amyloid PET imaging data. Digital phantom data were produced using segmented MRI scans from a control subject and an AD subject. Typical tracer distributions were generated for each of the phantom anatomies. Also examined were 70 clinical PET scans acquired using [(18)F]flutemetamol. Volume of interest (VOI) analysis was performed for corrected and uncorrected images. RESULTS: PVC was shown to improve the quantitative accuracy of regional analysis performed on amyloid PET images. Of the corrections applied, VC deconvolution demonstrated the worst recovery of grey matter values. MG PVC was shown to induce biases in some grey matter regions due to grey matter variability. In addition, white matter variability was shown to influence the accuracy of MG PVC in cortical grey matter and also cerebellar grey matter, a typical reference region for amyloid PET normalization in sporadic AD. RBV was shown to be more accurate than MG in terms of grey matter and white matter uptake. An increase in within-group variability after PVC was observed and is believed to be a genuine, more accurate representation of the data rather than a correction-induced error. The standardized uptake value ratio (SUVR) threshold for classifying subjects as either amyloid-positive or amyloid-negative was found to be 1.64 in the uncorrected dataset, rising to 2.25 after PVC. CONCLUSION: Care should be taken when applying PVC to amyloid PET images. Assumptions made in existing PVC strategies can induce biases that could lead to erroneous inferences about uptake in certain regions. The proposed RBV PVC technique accounts for within-compartment variability, with the potential to reduce errors of this kind.
Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Algoritmos , Encéfalo/diagnóstico por imagen , Ensayos Clínicos como Asunto , Humanos , Fantasmas de ImagenRESUMEN
Sprague Dawley rats (10/sex/group) were given a single intravenous (iv) dose of CUMI-101 to determine acute toxicity of CUMI-101 and radiation dosimetry estimations were conducted in baboons with [(11)C]CUMI-101. Intravenous administration of CUMI-101 did not produce overt biologically or toxicologically significant adverse effects except transient hypoactivity immediately after dose in the mid- and high-dose groups, which is not considered to be a dose-limiting toxic effect. No adverse effects were observed in the low-dose group. The no observed adverse effect level (NOAEL) is considered to be 44.05 µg/kg for a single iv dose administration in rats. The maximum tolerated dose (MTD) was estimated to be 881 µg/kg for a single iv dose administration. The Medical Internal Radiation Dose (MIRDOSE) estimates indicate the maximum permissible single-study dosage of [(11)C]CUMI-101 in humans is 52 mCi with testes and urinary bladder as the critical organ for males and females, respectively.
Asunto(s)
Piperazinas/farmacocinética , Agonistas del Receptor de Serotonina 5-HT1/farmacocinética , Triazinas/farmacocinética , Animales , Radioisótopos de Carbono , Femenino , Ligandos , Masculino , Papio , Piperazinas/toxicidad , Tomografía de Emisión de Positrones , Radiometría , Ratas , Ratas Sprague-Dawley , Agonistas del Receptor de Serotonina 5-HT1/toxicidad , Distribución Tisular , Triazinas/toxicidadRESUMEN
PURPOSE: Reconstruction of DaTSCAN brain studies using OS-EM iterative reconstruction offers better image quality and more accurate quantification than filtered back-projection. However, reconstruction must proceed for a sufficient number of iterations to achieve stable and accurate data. This study assessed the impact of the number of iterations on the image quantification, comparing the results of the iterative reconstruction with filtered back-projection data. METHODS: A striatal phantom filled with (123)I using striatal to background ratios between 2:1 and 10:1 was imaged on five different gamma camera systems. Data from each system were reconstructed using OS-EM (which included depth-independent resolution recovery) with various combinations of iterations and subsets to achieve up to 200 EM-equivalent iterations and with filtered back-projection. Using volume of interest analysis, the relationships between image reconstruction strategy and quantification of striatal uptake were assessed. RESULTS: For phantom filling ratios of 5:1 or less, significant convergence of measured ratios occurred close to 100 EM-equivalent iterations, whereas for higher filling ratios, measured uptake ratios did not display a convergence pattern. Assessment of the count concentrations used to derive the measured uptake ratio showed that nonconvergence of low background count concentrations caused peaking in higher measured uptake ratios. Compared to filtered back-projection, OS-EM displayed larger uptake ratios because of the resolution recovery applied in the iterative algorithm. CONCLUSION: The number of EM-equivalent iterations used in OS-EM reconstruction influences the quantification of DaTSCAN studies because of incomplete convergence and possible bias in areas of low activity due to the nonnegativity constraint in OS-EM reconstruction. Nevertheless, OS-EM using 100 EM-equivalent iterations provides the best linear discriminatory measure to quantify the uptake in DaTSCAN studies.
Asunto(s)
Algoritmos , Cuerpo Estriado/diagnóstico por imagen , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tropanos , Humanos , Fantasmas de Imagen , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único/instrumentaciónRESUMEN
PURPOSE: We compared simultaneous dual-radionuclide (DR) stress and rest myocardial perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT camera with separate stress and rest acquisitions. METHODS: Of 27 consecutive patients recruited, 24 (64.5+/-11.8 years of age, 16 men) were injected with 74 MBq of (201)Tl (rest) and 250 MBq (99m)Tc-MIBI (stress). Conventional MPI acquisition times for stress and rest are 21 min and 16 min, respectively. Rest (201)Tl for 6 min and simultaneous DR 15-min list mode gated scans were performed on a D-SPECT cardiac scanner. In 11 patients DR D-SPECT was performed first and in 13 patients conventional stress (99m)Tc-MIBI SPECT imaging was performed followed by DR D-SPECT. The DR D-SPECT data were processed using a spill-over and scatter correction method. DR D-SPECT images were compared with rest (201)Tl D-SPECT and with conventional SPECT images by visual analysis employing the 17-segment model and a five-point scale (0 normal, 4 absent) to calculate the summed stress and rest scores. Image quality was assessed on a four-point scale (1 poor, 4 very good) and gut activity was assessed on a four-point scale (0 none, 3 high). RESULTS: Conventional MPI studies were abnormal at stress in 17 patients and at rest in 9 patients. In the 17 abnormal stress studies DR D-SPECT MPI showed 113 abnormal segments and conventional MPI showed 93 abnormal segments. In the nine abnormal rest studies DR D-SPECT showed 45 abnormal segments and conventional MPI showed 48 abnormal segments. The summed stress and rest scores on conventional SPECT and DR D-SPECT were highly correlated (r=0.9790 and 0.9694, respectively). The summed scores of rest (201)Tl D-SPECT and DR-DSPECT were also highly correlated (r=0.9968, p<0.0001 for all). In six patients stress perfusion defects were significantly larger on stress DR D-SPECT images, and five of these patients were imaged earlier by D-SPECT than by conventional SPECT. CONCLUSION: Fast and high-quality simultaneous DR MPI is feasible with D-SPECT in a single imaging session with comparable diagnostic performance and image quality to conventional SPECT and to a separate rest (201)Tl D-SPECT acquisition.
Asunto(s)
Cámaras gamma , Corazón/diagnóstico por imagen , Imagen de Perfusión Miocárdica/instrumentación , Adulto , Anciano , Vasos Coronarios/diagnóstico por imagen , Femenino , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Descanso , Estrés Fisiológico , Factores de Tiempo , Tomografía Computarizada de Emisión de Fotón ÚnicoRESUMEN
PET with 18F-FDG has been increasingly applied, predominantly in the research setting, to study drug effects and pulmonary biology and to monitor disease progression and treatment outcomes in lung diseases that interfere with gas exchange through alterations of the pulmonary parenchyma, airways, or vasculature. To date, however, there are no widely accepted standard acquisition protocols or imaging data analysis methods for pulmonary 18F-FDG PET/CT in these diseases, resulting in disparate approaches. Hence, comparison of data across the literature is challenging. To help harmonize the acquisition and analysis and promote reproducibility, we collated details of acquisition protocols and analysis methods from 7 PET centers. From this information and our discussions, we reached the consensus recommendations given here on patient preparation, choice of dynamic versus static imaging, image reconstruction, and image analysis reporting.
Asunto(s)
Consenso , Fluorodesoxiglucosa F18 , Enfermedades Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Guías de Práctica Clínica como Asunto , Fluorodesoxiglucosa F18/administración & dosificación , Humanos , Procesamiento de Imagen Asistido por Computador , Inyecciones , Enfermedades Pulmonares/fisiopatología , Posicionamiento del Paciente , RespiraciónRESUMEN
D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and resolution recovery, it offers potential advantages over conventional systems. A series of measurements were made on a beta-version D-SPECT system in order to evaluate its performance in terms of energy resolution, scatter fraction, sensitivity, count rate capability and resolution. Corresponding measurements were also done on a conventional SPECT system (CS) for comparison. The energy resolution of the D-SPECT system at 140 keV was 5.5% (CS: 9.25%), the scatter fraction 30% (CS: 34%), the planar sensitivity 398 s(-1) MBq(-1) per head ((99m)Tc, 10 cm) (CS: 72 s(-1) MBq(-1)), and the tomographic sensitivity in the heart region was in the range 647-1107 s(-1) MBq(-1) (CS: 141 s(-1) MBq(-1)). The count rate increased linearly with increasing activity up to 1.44 M s(-1). The intrinsic resolution was equal to the pixel size, 2.46 mm (CS: 3.8 mm). The average reconstructed resolution using the standard clinical filter was 12.5 mm (CS: 13.7 mm). The D-SPECT has superior sensitivity to that of a conventional system with similar spatial resolution. It also has excellent energy resolution and count rate characteristics, which should prove useful in dynamic and dual radionuclide studies.
Asunto(s)
Cardiología/métodos , Medicina Nuclear/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Dispersión de Radiación , Sensibilidad y EspecificidadRESUMEN
RATIONALE: Ketamine induces effects resembling both positive and negative psychotic symptoms of schizophrenia. These are thought to arise through its action as an uncompetitive antagonist of the N-methyl-D-aspartate (NMDA) receptor. OBJECTIVES: We used [(123)I]CNS-1261 to study ketamine binding to NMDA receptors in healthy human controls in vivo and its relationship to positive and negative psychotic symptom induction. MATERIALS AND METHODS: Ten healthy controls underwent two single-photon emission tomography scans with [(123)I]CNS-1261. On each occasion, they received a bolus infusion of either ketamine or saline. The Brief Psychiatric Rating Scale (BPRS) was administered at the end of each scan. Predefined regions of interest were used to estimate change in volume of distribution of [(123)I]CNS-1261 following ketamine administration. Two normalised-to-cortex binding indices were also used in order to study effects of ketamine on NMDA receptor availability by region, after correction for global and nonspecific effects. RESULTS: Ketamine-induced reduction in [(123)I]CNS-1261 volume of distribution in all regions showed the strongest correlation with BPRS negative subscale (p < 0.01). With the normalised-to-cortex measures, NMDA receptor binding in middle inferior frontal cortex showed a significant correlation with BPRS negative subscale (BI1 r = 0.88, BI2 r = 95.9, p < 0.001). CONCLUSIONS: [(123)I]CNS-1261 binding was modulated by ketamine, a drug known to compete for the same site on the NMDA receptor in vitro. Ketamine may induce negative symptoms through direct inhibition of the NMDA receptor, and positive symptoms may arise through a different neurochemical pathway.
Asunto(s)
Guanidinas , Radioisótopos de Yodo , Ketamina/toxicidad , Corteza Prefrontal/efectos de los fármacos , Corteza Prefrontal/diagnóstico por imagen , Psicosis Inducidas por Sustancias/diagnóstico por imagen , Psicosis Inducidas por Sustancias/fisiopatología , Receptores de N-Metil-D-Aspartato/efectos de los fármacos , Esquizofrenia/inducido químicamente , Esquizofrenia/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Escalas de Valoración Psiquiátrica Breve , Relación Dosis-Respuesta a Droga , Guanidinas/farmacocinética , Humanos , Infusiones Intravenosas , Radioisótopos de Yodo/farmacocinética , Ketamina/administración & dosificación , Ketamina/farmacocinética , Masculino , Receptores de N-Metil-D-Aspartato/metabolismo , Método Simple CiegoRESUMEN
We present a standalone, scalable and high-throughput software platform for PET image reconstruction and analysis. We focus on high fidelity modelling of the acquisition processes to provide high accuracy and precision quantitative imaging, especially for large axial field of view scanners. All the core routines are implemented using parallel computing available from within the Python package NiftyPET, enabling easy access, manipulation and visualisation of data at any processing stage. The pipeline of the platform starts from MR and raw PET input data and is divided into the following processing stages: (1) list-mode data processing; (2) accurate attenuation coefficient map generation; (3) detector normalisation; (4) exact forward and back projection between sinogram and image space; (5) estimation of reduced-variance random events; (6) high accuracy fully 3D estimation of scatter events; (7) voxel-based partial volume correction; (8) region- and voxel-level image analysis. We demonstrate the advantages of this platform using an amyloid brain scan where all the processing is executed from a single and uniform computational environment in Python. The high accuracy acquisition modelling is achieved through span-1 (no axial compression) ray tracing for true, random and scatter events. Furthermore, the platform offers uncertainty estimation of any image derived statistic to facilitate robust tracking of subtle physiological changes in longitudinal studies. The platform also supports the development of new reconstruction and analysis algorithms through restricting the axial field of view to any set of rings covering a region of interest and thus performing fully 3D reconstruction and corrections using real data significantly faster. All the software is available as open source with the accompanying wiki-page and test data.
Asunto(s)
Encéfalo/diagnóstico por imagen , Análisis de Datos , Ensayos Analíticos de Alto Rendimiento/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía de Emisión de Positrones/métodos , Programas Informáticos , Ensayos Analíticos de Alto Rendimiento/normas , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Tomografía de Emisión de Positrones/normas , Programas Informáticos/normasRESUMEN
BACKGROUND: Kinetic analysis of dynamic PET data requires an accurate knowledge of available PET tracer concentration within blood plasma over time, known as the arterial input function (AIF). The gold standard method used to measure the AIF requires serial arterial blood sampling over the course of the PET scan, which is an invasive procedure and makes this method less practical in clinical settings. Traditional image-derived methods are limited to specific tracers and are not accurate if metabolites are present in the plasma. RESULTS: In this work, we utilise an image-derived whole blood curve measurement to reduce the computational complexity of the simultaneous estimation method (SIME), which is capable of estimating the AIF directly from tissue time activity curves (TACs). This method was applied to data obtained from a serotonin receptor study (11C-SB207145) and estimated parameter results are compared to results obtained using the original SIME and gold standard AIFs derived from arterial samples. Reproducibility of the method was assessed using test-retest data. It was shown that the incorporation of image-derived information increased the accuracy of total volume of distribution (V T) estimates, averaged across all regions, by 40% and non-displaceable binding potential (BP ND) estimates by 16% compared to the original SIME. Particular improvements were observed in K1 parameter estimates. BP ND estimates, based on the proposed method and the gold standard arterial sample-derived AIF, were not significantly different (P=0.7). CONCLUSIONS: The results of this work indicate that the proposed method with prior AIF information obtained from a partial volume corrected image-derived whole blood curve, and modelled parent fraction, has the potential to be used as an alternative non-invasive method to perform kinetic analysis of tracers with metabolite products.
RESUMEN
There is increasing clinical use of combined positron emission tomography and MRI, but to date there has been no clinical system developed capable of simultaneous single-photon emission computed tomography (SPECT) and MRI. There has been development of preclinical systems, but there are several challenges faced by researchers who are developing a clinical prototype including the need for the system to be compact and stationary with MRI-compatible components. The limited work in this area is described with specific reference to the Integrated SPECT/MRI for Enhanced stratification in Radio-chemo Therapy (INSERT) project, which is at an advanced stage of developing a clinical prototype. Issues of SPECT/MRI compatibility are outlined and the clinical appeal of such a system is discussed, especially in the management of brain tumour treatment.
Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Neoplasias Encefálicas/diagnóstico por imagen , Medios de Contraste , Diseño de Equipo , Humanos , Imagenología Tridimensional , Imagen Multimodal/instrumentaciónRESUMEN
Positron emission tomography (PET) studies of the serotonin transporter (5-HTT) in the human brain are increasingly using the radioligand [(11)C]N, N-dimethyl-2-(2-amino-4-cyanophenylthio) benzylamine. A variety of models have been applied to such data in several published articles; however to date, these models have not been validated with test-retest data. We recruited 11 healthy subjects and conducted two identical scans on each subject on the same day. We considered four different models (one- and two-tissue compartment kinetic models, likelihood estimation in graphical analysis (LEGA; a bias-free alternative to the graphical method), and basis pursuit) along with fast noniterative approximations to the kinetic models. We considered four different outcome measures (total volume of distribution (V(T)), binding potential with (BP) and without (BP(1)), free-fraction adjustment, and specific-to-nonspecific equilibrium partition coefficient (BP(2))). To assess the performance of each model, we compared results using six different metrics (percent difference (PD) and within-subject mean sum of squares for reproducibility, interclass coefficient for reliability, variance across subjects, identifiability based on bootstrap resampling of residuals for each method, and time stability analysis to determine minimal required scanning time). We considered analysis of both at the voxel level and at the region of interest (ROI) level and compared results from these two approaches to assess agreement. We determined that 100 mins of scanning time is adequate and that for ROI-level analysis, LEGA gives best results. Average PD is 5.51 for V(T), 20.7 for BP, 17.2 for BP(1), and 16.5 for BP(2) across all regions. For voxel-level analysis we determined that the one-tissue compartment noniterative model is best.
Asunto(s)
Compuestos de Anilina , Encéfalo/diagnóstico por imagen , Radiofármacos , Proteínas de Transporte de Serotonina en la Membrana Plasmática/metabolismo , Sulfuros , Adolescente , Adulto , Anciano , Algoritmos , Radioisótopos de Carbono , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Cinética , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Modelos Neurológicos , Modelos Estadísticos , Tomografía de Emisión de Positrones , Valores de Referencia , Reproducibilidad de los ResultadosRESUMEN
UNLABELLED: We present a method for pharmacokinetic modeling of distributions of (111)In-labeled monoclonal antibodies (mAbs) on individual pixels of planar scintillation-camera images. METHODS: The method is applied to 2 sets of clinical whole-body images, each consisting of 6 consecutive images acquired over a week. Quantification is performed on a pixel basis, yielding images in units of Bq/pixel. The images acquired on the different occasions are registered using a nonrigid method, and for each pixel location a time-activity curve is obtained for which kinetic modeling is performed. The (111)In-mAb is assumed to be located in either the vascular or the extravascular space. The vascular content is assumed to follow the global blood kinetics as determined from blood samples, together with a model parameter alpha that describes the fraction of the whole-body blood volume present in the particular pixel. The rate of change of the extravascular compartment is described by a linear 1-tissue-compartment model with 2 rate constants, K'1 and k2, reflecting extravasation and washout, respectively. The model is optimized for each pixel position with regard to the values of the 3 parameters (alpha, K'1, and k2), resulting in 3 parametric images. From these, images of the cumulated activity in vascular and extravascular spaces are calculated, as is an image of the rate-constants ratio, which is closely related to the volume of distribution. RESULTS: The resulting parametric images are analyzed in terms of the appearance of the time-activity curves at various locations. Results also include interpretation of the parametric images in their clinical context, and the location of regions that exhibit high extravasation and a low washout rate is compared with confirmed malignant sites. CONCLUSION: Parametric imaging allows the study and analysis of the spatial and temporal distributions of mAbs simultaneously. Parametric imaging enhances regions where the pharmacokinetics differ from the surrounding tissue and provides a tool to detect and locate unexpected kinetic behavior, which is sometimes characteristic of malignant tissue. For dosimetry in radionuclide therapy, parametric imaging offers a less biased means of analyzing serial mAb images than traditional region-of-interest-based analysis.
Asunto(s)
Anticuerpos Monoclonales/farmacocinética , Radioisótopos de Indio , Radioinmunodetección , Humanos , Modelos Biológicos , Dosis de RadiaciónRESUMEN
OBJECTIVE: Monoamine oxidase A is a mitochondrial enzyme which is responsible for the metabolism of catecholamines such as dopamine, norepinephrine, as well as serotonin. This study describes the biodistribution and dosimetry of 11C-harmine, a tracer designed to specifically bind to monoamine oxidase A for positron emission tomography imaging. METHODS: Three baboon studies were acquired using a Seimens ECAT camera. Dynamic whole-body emission scans were collected in two-dimensional mode over a 2 h period after 223-255 MBq of 11C-harmine was injected. Regions of interest were drawn on transmission corrected images to encompass the entire activity in visible organs at each time point. Time-activity data were used to obtain residence times and absorbed radiation dose to various organs and to the entire body. RESULTS: Tracer uptake was greatest in the lungs, followed by kidney, small intestine, liver and brain. The largest absorbed dose based on averaged residence times was found in the lungs (reference adult/female 3.99x10(-2)/5.03x10(-2) mSv x MBq(-1)). CONCLUSION: The lungs are the critical organs for administration of 11C-harmine. For example, in the United States, the absorbed dose to the lungs would limit a single 11C-harmine administration for a research subject with the approval of a Radioactive Drug Research Committee to 1258/999 MBq (34/27 mCi) in the adult male/female. Quantitative measurement of monoamine oxidase A activity in the brain and elsewhere may aid in understanding the pathophysiology of several disease processes including neuroendocrine neoplasms and depression.