Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Osteoarthritis Cartilage ; 19(7): 809-15, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21524707

RESUMEN

OBJECTIVE: To study the association between change in the body mass index (BMI) at different ages and the risk of a later total hip replacement (THR) due to primary osteoarthritis (OA). DESIGN: A total of 265,725 individuals who had two repeated measurements of weight and height were included from national health screenings. These individuals were followed prospectively. The data were matched with the Norwegian Arthroplasty Register and 4,442 of these individuals were identified as having received a THR for primary OA. Cox proportional hazard regression was used to calculate sex-specific relative risks for having a THR according to age at screening and BMI change. RESULTS: Men and women aged 20 years or younger at the first screening in the quartile with the greatest BMI change per year had more than twice the risk of later having a THR compared with those in the quartile with the smallest BMI change per year. For men older than 30 years at the first screening, there was no relationship between BMI gain, or weight gain, and later risk of THR. For older women, BMI gain was associated with risk of THR, but to a lesser degree than in younger women. CONCLUSION: There was a clear relationship between change in BMI and the risk of later THR in young men and women, whereas the association was absent in older men and weaker in older women. It is important to focus on weight control to prevent future OA, and the preventive strategy should be focused on the young population.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osteoartritis de la Cadera/cirugía , Aumento de Peso/fisiología , Adulto , Factores de Edad , Índice de Masa Corporal , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Adulto Joven
2.
J Wound Care ; 20(3): 136-42, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21537297

RESUMEN

OBJECTIVE: To compare the performance of Hydrofiber and alginate dressings used in the treatment of primary hip arthroplasty wounds. METHOD: Patients were randomised into one of two groups, receiving either a Hydrofiber or an alginate dressing. Outcome measures, assessed by daily observations, included skin damage (erythema, blisters and skin injuries) and the dressing's ability to handle exudates. Photos of the dressing and the skin area around wounds were taken. Patients noted skin problems, discomfort at mobilisation and pain at dressing removal. RESULTS: In the alginate group, there were fewer blisters in the wound area compared with the Hydrofiber group (7% versus 18%, p=0.03). During dressing removal, fewer patients in the alginate group reported pain than patients in the Hydrofiber group (2.1% versus 15%, p=0.01) CONCLUSION: We recommend the use of both dressings following total hip arthroplasty, although the alginate would be our first choice, as we found fewer blisters when using alginate dressings as opposed to Hydrofiber dressings. CONFLICT OF INTEREST: None.


Asunto(s)
Alginatos/uso terapéutico , Artroplastia de Reemplazo de Cadera , Vendas Hidrocoloidales , Carboximetilcelulosa de Sodio/uso terapéutico , Infecciones Relacionadas con Prótesis/prevención & control , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Cuidados Posoperatorios/métodos , Resultado del Tratamiento
3.
J Bone Joint Surg Am ; 89(3): 519-25, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17332100

RESUMEN

BACKGROUND: Concern exists regarding the durability of unicompartmental knee replacements. The purpose of the present study was to compare the early failure rates and failure mechanisms of primary cemented unicompartmental knee replacements with those of primary cemented tricompartmental total knee replacements. METHODS: The rates of failure of primary cemented unicompartmental knee replacements (n = 2288) and tricompartmental total knee replacements (n = 3032) as reported to the Norwegian Arthroplasty Register from January 1994 through December 2004 were compared with use of Kaplan-Meier estimated survival rates and Cox multiple regression. RESULTS: The ten-year survival probability was 80.1% (95% confidence interval, 76.0% to 84.2%) for unicompartmental knee replacements, compared with 92.0% (95% confidence interval, 90.4 to 93.6%) for total knee replacements, with a relative risk of revision of 2.0 (95% confidence interval, 1.6 to 2.5) (p < 0.001). This increased risk of revision following unicompartmental knee replacement was seen in all age-categories. Unicompartmental knee replacement was associated with an increased risk of revision due to pain (relative risk, 11.3 [95% confidence interval, 4.8 to 26.8]; p < 0.001), aseptic loosening of the tibial component (relative risk, 1.9 [95% confidence interval, 1.2 to 3.0]; p = 0.01) and of the femoral component (relative risk, 4.8 [95% confidence interval, 2.3 to 10.3]; p < 0.001), and periprosthetic fracture (relative risk, 3.2 [95% confidence interval, 1.2 to 8.9]; p = 0.02) as compared with total knee replacement. Unicompartmental knee replacement was associated with a lower risk of infection compared with total knee replacement (relative risk, 0.28 [95% confidence interval, 0.10 to 0.74]; p = 0.01). CONCLUSIONS: The survival of cemented unicompartmental knee replacements is inferior to that of cemented tricompartmental total knee replacements in all age-categories.


Asunto(s)
Cementos para Huesos , Prótesis de la Rodilla , Falla de Prótesis , Reoperación/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Persona de Mediana Edad , Noruega , Complicaciones Posoperatorias/epidemiología , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Insuficiencia del Tratamiento
4.
J Psychosom Res ; 79(4): 309-15, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26208403

RESUMEN

BACKGROUND: Depression and anxiety have been found to be predictors of poor health outcomes in diabetes, but mechanisms are still unclear. AIMS: To examine whether symptoms of anxiety and depression were associated with timing of initiating insulin therapy. METHODS: A cohort study of insulin-naive particpants with type 2 dabetes completed the Hospital Anxiey and Depression Scale, HADS-A (n = 731) and/or the HADS-D (n = 768) in the communy-based Nord-Trøndelag Health Study (1995-1997). Information on insulin initiation was retrieved from the Norwegian Prescription Database from January 1, 2004 to November 21, 2012. Cox regression analyses were used to estimate the association between symptoms of anxiety, depression and time to insulin initiation. RESULTS: At baseline, 19% reported anxiety symptoms (score≥8) and 18% depressive symptoms (score≥8). After a mean follow-up of 4.4 (SD 3.6) years, 337 (40%) participants had started insulin therapy. After adjustment for sociodemographic and clinical variables, anxiety symptoms were associated with later initiation of insulin therapy (HR 0.70, 95% CI 0.49-0.99), while depressive symptoms were not. Considering groups simultaneously, having both elevated depressive and elevated anxiety symptoms was associated with later time to insulin initiation (HR 0.62, 95% CI 0.39-0.99), while having only anxiety symptoms (without depressive) HR 0.81, 95% CI 0.50-1.32) or only depressive symptoms (without anxiety) (HR 1.08, 95% CI 0.68-1.72) were not. CONCLUSIONS: Anxiety was associated with a later initiation of insulin, while depressive symptoms were not. Persons with both elevated levels of anxiety and depression were also less likely to start insulin therapy. These results need further testing in other prospective studies.


Asunto(s)
Ansiedad/etiología , Depresión/etiología , Diabetes Mellitus Tipo 2/complicaciones , Insulina/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Depresión/diagnóstico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Femenino , Humanos , Insulina/administración & dosificación , Masculino , Persona de Mediana Edad , Noruega , Estudios Prospectivos , Adulto Joven
5.
Bone Joint J ; 97-B(11): 1463-9, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26530646

RESUMEN

We report the five-year outcome of a randomised controlled trial which used radiostereometric analysis (RSA) to assess the influence of surface oxidised zirconium (OxZr, Oxinium) on polyethylene wear in vivo. A total of 120 patients, 85 women and 35 men with a mean age of 70 years (59 to 80) who were scheduled for primary cemented total hip arthroplasty were randomly allocated to four study groups. Patients were blinded to their group assignment and received either a conventional polyethylene (CPE) or a highly cross-linked (HXL) acetabular component of identical design. On the femoral side patients received a 28 mm head made of either cobalt-chromium (CoCr) or OxZr. The proximal head penetration (wear) was measured with repeated RSA examinations over five years. Clinical outcome was measured using the Harris hip score. There was no difference in polyethylene wear between the two head materials when used with either of the two types of acetabular component (p = 0.3 to 0.6). When comparing the two types of polyethylene there was a significant difference in favour of HXLPE, regardless of the head material used (p < 0.001). In conclusion, we found no advantage of OxZr over CoCr in terms of polyethylene wear after five years of follow-up. Our findings do not support laboratory results which have shown a reduced rate of wear with OxZr. They do however add to the evidence on the better resistance to wear of HXLPE over CPE.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cabeza Femoral/cirugía , Prótesis de Cadera , Circonio , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Cementación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Análisis Radioestereométrico/métodos , Resultado del Tratamiento
6.
J Bone Joint Surg Am ; 77(10): 1543-50, 1995 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7593063

RESUMEN

We studied the survival of 8579 Charnley prostheses, in 7922 patients, according to the different types of cement that had been used. All of the patients had had a primary total hip replacement for primary coxarthrosis. The mean duration of follow-up was 3.2 years (range, zero to 6.4 years). The data were collected from the national Norwegian Arthroplasty Register. The duration of survival was defined as the time to revision due to aseptic loosening. The Kaplan-Meier estimate of survival at 5.5 years for the 1226 femoral components that had been implanted with low-viscosity cement was 94.1 per cent (95 per cent confidence interval, 92.1 to 96.2 per cent), compared with 98.1 per cent (95 per cent confidence interval, 97.5 to 98.6 per cent) for the 6589 components that had been implanted with high-viscosity cement (p < 0.0001). The remaining 764 femoral components had been implanted with Boneloc cement, which was classified as neither high nor low-viscosity, and these components were considered as a separate group in the analyses. The Boneloc cement had been used for only three years, and the two-year survival rate of these prostheses was 95.5 per cent (p < 0.0001). The cement contained an antibiotic in 2801 (42 per cent of the hips in which the femoral component had been implanted with high-viscosity cement, compared with only thirty (2 per cent) of those in which it had been implanted with low-viscosity cement.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Cementos para Huesos , Prótesis de Cadera/estadística & datos numéricos , Acetábulo/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Antibacterianos/administración & dosificación , Cementos para Huesos/química , Femenino , Fémur/cirugía , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Humanos , Masculino , Metacrilatos/química , Persona de Mediana Edad , Noruega/epidemiología , Osteoartritis de la Cadera/cirugía , Modelos de Riesgos Proporcionales , Falla de Prótesis , Sistema de Registros , Reoperación , Factores de Tiempo , Viscosidad
7.
Spine (Phila Pa 1976) ; 26(7): 800-8, 2001 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-11295903

RESUMEN

STUDY DESIGN: A randomized, controlled trial. OBJECTIVE: To examine the impact of physical function and pain on work status in patients who are long-term sick-listed because of back pain. SUMMARY OF BACKGROUND DATA: Sickness benefit is granted to a person who is incapable of working because of reduced functioning. Improved physical function and decrease of pain may be important in considering return to work. METHODS: Physical performance (five activities), disability, and pain (self-reported questionnaires) were assessed at baseline and at the 1-year follow-up evaluation in 117 patients randomized to an intervention group (n = 81) and a control group (n = 36). RESULTS: At the 1-year follow-up evaluation, 50% had returned to work. Statistically significant improvements were demonstrated from baseline to follow-up evaluation in returners to work: in the intervention group on all tests and in the control group on all except two performance tests. Improvement measures discriminated between returners and nonreturners to work in the intervention group on all physical tests and a pain test and in the control group on three physical tests and a pain test. In the intervention group, odds ratios for not having returned to work were high when test measures at follow-up indicated markedly impaired physical function and high pain; in the control group, this appeared in high pain. CONCLUSIONS: Return to work was related to physical function and pain. More importance seemed to be attributed to physical performance in the intervention group than in the controls as a basis for returning patients to work.


Asunto(s)
Dolor de Espalda/fisiopatología , Dolor/fisiopatología , Aptitud Física/fisiología , Trabajo/fisiología , Adulto , Evaluación de la Discapacidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Trabajo/estadística & datos numéricos
8.
J Bone Joint Surg Br ; 84(6): 839-45, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12211674

RESUMEN

We have compared the survival of two hydroxyapatite (HA)-coated cups, 1208 Atoll hemispheric and 2641 Tropic threaded, with cemented Charnley all-polyethylene cups (16 021) using the Cox regression model. The Tropic cup used in combination with an alumina ceramic femoral head, had good results, similar to those of the Charnley cup. When used in combination with a stainless-steel head, however, the risk of revision beyond four years was increased 3.4 times for the Tropic cup compared with the Charnley cup (p < 0.001). Over the same period, the Atoll cup had an increased risk of revision of 3.8 times when used with the alumina heads (p < 0.001) and an increased risk of 6.1 times when used with stainless-steel heads (p < 0.001). Revision because of wear and osteolysis was more common with both types of HA-coated cup than with the Charnley cup. The rate of revision of the Atoll cup because of aseptic loosening was also increased. We found that HA-coated cups did not perform better than the Charnley cup.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Materiales Biocompatibles/uso terapéutico , Cementos para Huesos/uso terapéutico , Durapatita/uso terapéutico , Prótesis de Cadera/efectos adversos , Polietileno/uso terapéutico , Adulto , Factores de Edad , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Materiales Biocompatibles/efectos adversos , Durapatita/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación , Factores de Riesgo , Factores de Tiempo
9.
J Bone Joint Surg Br ; 77(1): 11-7, 1995 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-7822364

RESUMEN

The Norwegian Arthroplasty Register recorded 24,408 primary total hip replacements from 1987 to 1993; 2907 of them (13%) were performed with uncemented femoral components. We have compared the results of eight different designs, each used in more than 100 patients. Survivorship of the components was estimated by the Kaplan-Meier method using revision for aseptic loosening of the femoral component as the end-point. At 4.5 years, the estimated probability of revision for aseptic loosening for all implants was 4.5%, for the Bio-Fit stem 18.6% (n = 210) and for the Femora stem 13.6% (n = 173). The PM-Prosthesis and the Harris/Galante stem prostheses needed revision in 5.6% and 3.6%, respectively. The clockwise threaded stem of the Femora implant needed revision in 20% of right hips, but in only 4% of left hips. The short-term results of the four best uncemented femoral components (Corail, LMT, Profile and Zweimüller) were similar to those for cemented stems, with revision for loosening in less than 1% at 4.5 years. The importance of the control of innovative designs and the registration of early results is discussed.


Asunto(s)
Prótesis de Cadera/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cementos para Huesos , Femenino , Fémur , Humanos , Masculino , Persona de Mediana Edad , Noruega , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Análisis de Supervivencia
10.
J Bone Joint Surg Br ; 84(6): 832-8, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12211673

RESUMEN

Using data from the Norwegian Arthroplasty egister, we have assessed the survival of 17 323 primary Charnley hip prostheses in patients with osteoarthritis based upon the type of cement used for the fixation of the implant. Overall, 9.2% had been revised after follow-up for ten years; 71% of the failures involved aseptic loosening of the femoral component. We observed significantly increased rates of failure for prostheses inserted with CMW1 and CMW3 cements. Using implants fixed with gentamicin-containing Palacos cement as the reference, the adjusted Cox regression failure rate ratios were 1.1 (95% CI 0.9 to 1.4) for implants cemented with plain Palacos, 1.1 (95% CI 0.7 to 1.6) for Simplex, 2.1 (95% 1.5 to 2.9) for gentamicin-containing CMW1, 2.0 (95% CI 1.6 to 2.4) for plain CMW1 and 3.0 (95% CI 2.3 to 3.9) for implants fixed with CMW3 cement. The adjusted failure rate at ten years varied from 5.9% for implants fixed with gentamicin-containing Palacos to 17% for those fixed with CMW3.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Cementos para Huesos/uso terapéutico , Falla de Prótesis , Anciano , Artroplastia de Reemplazo de Cadera/mortalidad , Cementos para Huesos/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Análisis de Supervivencia , Insuficiencia del Tratamiento , Viscosidad
11.
J Bone Joint Surg Br ; 79(4): 590-5, 1997 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9250744

RESUMEN

We have assessed the effect of different regimes of antibiotic prophylaxis on the survival of total hip implants, comparing antibiotics administered both systemically and in the bone cement, systemically only, in the bone cement only and with no antibiotics given. We studied 10,905 primary cemented total hip replacements, performed for osteoarthritis of the hip and reported to the Norwegian arthroplasty register between 1987 and 1995. Cox-estimated failure-rate ratios (FRR) are presented with adjustment for gender, age, the brand of cement, the prosthesis, the type of operating theatre and the operating time. For revisions performed for infection (39 operations), the lowest rate of revision was found among patients receiving antibiotic-containing cement plus systemic antibiotics (n = 5804). The revision rate for the 4586 patients receiving systemic antibiotics only was 4.3 times greater (95% CI 1.7 to 11.0, p = 0.001); in 239 with antibiotics in the bone cement only it was 6.3 times greater (CI 1.6 to 25.0, p = 0.003); and in the 276 who did not receive antibiotics it was by 11.5 times greater (CI 2.1 to 63.0, p = 0.002). Adjustment for the total amount of systemic antibiotic administered did not change the results. We also observed an increased revision rate for aseptic loosening (109 operations) comparing the systemic-only (FRR = 1.8, CI 1.1 to 2.9, p = 0.01) and the cement-only regimes (FRR = 2.6, CI 1.2 to 5.9, p = 0.02) with the combined dosage. Our findings show that systemic antibiotics combined with antibiotic-containing bone cement led to fewer revisions than the other methods.


Asunto(s)
Profilaxis Antibiótica , Prótesis de Cadera , Cementos para Huesos , Humanos , Noruega , Osteoartritis de la Cadera/cirugía , Complicaciones Posoperatorias/prevención & control , Pronóstico , Falla de Prótesis , Sistema de Registros , Análisis de Regresión , Reoperación
12.
J Bone Joint Surg Br ; 83(4): 579-86, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11380136

RESUMEN

We studied the rates of revision for 53,698 primary total hip replacements (THRs) in nine different groups of disease. Factors which have previously been shown to be associated with increased risk of revision, such as male gender, young age, or certain types of uncemented prosthesis, showed important differences between the diagnostic groups. Without adjustment for these factors we observed an increased risk of revision in patients with paediatric hip diseases and in a small heterogeneous 'other' group, compared with patients with primary osteoarthritis. Most differences were reduced or disappeared when an adjustment for the prognostic factors was made. After adjustment, an increased relative risk (RR) of revision compared with primary osteoarthritis was seen in hips with complications after fracture of the femoral neck (RR = 1.3, p = 0.0005), in hips with congenital dislocation (RR = 1.3, p = 0.03), and in the heterogenous 'other' group. The analyses were also undertaken in a more homogenous subgroup of 16,217 patients which had a Charnley prosthesis implanted with high-viscosity cement. The only difference in this group was an increased risk for revision in patients who had undergone THR for complications after fracture of the femoral neck (RR = 1.5, p = 0.0005). THR for diagnoses seen mainly among young patients had a good prognosis, but they had more often received inferior uncemented implants. If a cemented Charnley prosthesis is used, the type of disease leading to THR seems in most cases to have only a minor influence on the survival of the prosthesis.


Asunto(s)
Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Articulación de la Cadera , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artritis Reumatoide/cirugía , Cementos para Huesos , Femenino , Fracturas del Cuello Femoral/complicaciones , Estudios de Seguimiento , Luxación Congénita de la Cadera/cirugía , Prótesis de Cadera , Humanos , Artropatías/cirugía , Masculino , Persona de Mediana Edad , Noruega , Osteoartritis de la Cadera/cirugía , Pronóstico , Reoperación
13.
Bone Joint J ; 96-B(5): 609-18, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24788494

RESUMEN

We performed a randomised controlled trial comparing computer-assisted surgery (CAS) with conventional surgery (CONV) in total knee replacement (TKR). Between 2009 and 2011 a total of 192 patients with a mean age of 68 years (55 to 85) with osteoarthritis or arthritic disease of the knee were recruited from four Norwegian hospitals. At three months follow-up, functional results were marginally better for the CAS group. Mean differences (MD) in favour of CAS were found for the Knee Society function score (MD: 5.9, 95% confidence interval (CI) 0.3 to 11.4, p = 0.039), the Knee Injury and Osteoarthritis Outcome Score (KOOS) subscales for 'pain' (MD: 7.7, 95% CI 1.7 to 13.6, p = 0.012), 'sports' (MD: 13.5, 95% CI 5.6 to 21.4, p = 0.001) and 'quality of life' (MD: 7.2, 95% CI 0.1 to 14.3, p = 0.046). At one-year follow-up, differences favouring CAS were found for KOOS 'sports' (MD: 11.0, 95% CI 3.0 to 19.0, p = 0.007) and KOOS 'symptoms' (MD: 6.7, 95% CI 0.5 to 13.0, p = 0.035). The use of CAS resulted in fewer outliers in frontal alignment (> 3° malalignment), both for the entire TKR (37.9% vs. 17.9%, p = 0.042) and for the tibial component separately (28.4% vs 6.3%, p = 0.002). Tibial slope was better achieved with CAS (58.9% vs. 26.3%, p < 0.001). Operation time was 20 minutes longer with CAS. In conclusion, functional results were, statistically, marginally in favour of CAS. Also, CAS was more predictable than CONV for mechanical alignment and positioning of the prosthesis. However, the long-term outcomes must be further investigated.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/rehabilitación , Desviación Ósea/etiología , Desviación Ósea/prevención & control , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/fisiopatología , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Ajuste de Prótesis/métodos , Rango del Movimiento Articular , Recuperación de la Función , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/rehabilitación , Resultado del Tratamiento
14.
Bone Joint J ; 95-B(5): 636-42, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23632673

RESUMEN

We evaluated the rates of survival and cause of revision of seven different brands of cemented primary total knee replacement (TKR) in the Norwegian Arthroplasty Register during the years 1994 to 2009. Revision for any cause, including resurfacing of the patella, was the primary endpoint. Specific causes of revision were secondary outcomes. Three posterior cruciate-retaining (PCR) fixed modular-bearing TKRs, two fixed non-modular bearing PCR TKRs and two mobile-bearing posterior cruciate-sacrificing TKRs were investigated in a total of 17 782 primary TKRs. The median follow-up for the implants ranged from 1.8 to 6.9 years. Kaplan-Meier 10-year survival ranged from 89.5% to 95.3%. Cox's relative risk (RR) was calculated relative to the fixed modular-bearing Profix knee (the most frequently used TKR in Norway), and ranged from 1.1 to 2.6. The risk of revision for aseptic tibial loosening was higher in the mobile-bearing LCS Classic (RR 6.8 (95% confidence interval (CI) 3.8 to 12.1)), the LCS Complete (RR 7.7 (95% CI 4.1 to 14.4)), the fixed modular-bearing Duracon (RR 4.5 (95% CI 1.8 to 11.1)) and the fixed non-modular bearing AGC Universal TKR (RR 2.5 (95% CI 1.3 to 5.1)), compared with the Profix. These implants (except AGC Universal) also had an increased risk of revision for femoral loosening (RR 2.3 (95% CI 1.1 to 4.8), RR 3.7 (95% CI 1.6 to 8.9), and RR 3.4 (95% CI 1.1 to 11.0), respectively). These results suggest that aseptic loosening is related to design in TKR.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Cementos para Huesos , Femenino , Humanos , Prótesis de la Rodilla/efectos adversos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación
15.
J Bone Joint Surg Br ; 94(3): 302-7, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22371534

RESUMEN

In this prospective study we studied the effect of the inclination angle of the acetabular component on polyethylene wear and component migration in cemented acetabular sockets using radiostereometric analysis. A total of 120 patients received either a cemented Reflection All-Poly ultra-high-molecular-weight polyethylene or a cemented Reflection All-Poly highly cross-linked polyethylene acetabular component, combined with either cobalt-chrome or Oxinium femoral heads. Femoral head penetration and migration of the acetabular component were assessed with repeated radiostereometric analysis for two years. The inclination angle was measured on a standard post-operative anteroposterior pelvic radiograph. Linear regression analysis was used to determine the relationship between the inclination angle and femoral head penetration and migration of the acetabular component. We found no relationship between the inclination angle and penetration of the femoral head at two years' follow-up (p = 0.9). Similarly, our data failed to reveal any statistically significant correlation between inclination angle and migration of these cemented acetabular components (p = 0.07 to p = 0.9).


Asunto(s)
Acetábulo/patología , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Falla de Prótesis/etiología , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Anciano , Anciano de 80 o más Años , Cementación , Femenino , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/patología , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/patología , Humanos , Masculino , Persona de Mediana Edad , Polietilenos , Estudios Prospectivos , Diseño de Prótesis , Análisis Radioestereométrico/métodos
16.
ISRN Orthop ; 2012: 437675, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-24977078

RESUMEN

High rates of Staphylococcus aureus are reported in prosthetic joint infection (PJI) in rheumatoid arthritis (RA). RA patients are considered to have a high risk of infection with bacteria of potentially oral or dental origin. One thousand four hundred forty-three revisions for infection were reported to the Norwegian Arthroplasty Register (NAR) from 1987 to 2007. For this study 269 infection episodes in 255 OA patients served as control group. In the NAR we identified 49 infection episodes in 37 RA patients from 1987 to 2009. The RA patients were, on average, 10 years younger than the OA patients and there were more females (70% versus 54%). We found no differences in the bacterial findings in RA and OA. A tendency towards a higher frequency of Staphylococcus aureus (18% versus 11%) causing PJI was found in the RA patients compared to OA. There were no bacteria of potential odontogenic origin found in the RA patients, while we found 4% in OA. The bacteria identified in revisions for infection in THRs in patients with RA did not significantly differ from those in OA. Bacteria of oral or dental origin were not found in infected hip joint replacements in RA.

17.
Br J Surg ; 77(7): 725-30, 1990 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-2200555

RESUMEN

Between 1984 and 1987, 176 Norwegian patients with histologically verified unresectable pancreatic adenocarcinoma were randomized to double-blind treatment with oral tamoxifen (30 mg daily; 48 men and 44 women) or placebo (47 men and 37 women). Analysis of oestrogen receptor activity in the carcinomas was not performed. There were no statistically significant differences between the two groups according to age, Karnofsky performance index, tumour node metastasis (TNM) stage, operative treatment or other patient characteristics. The tamoxifen or placebo treatment continued to death or to 10 months after accrual into the trial was stopped. In the tamoxifen group, the mean and median survivals were 205 and 115 days, respectively. These values did not differ statistically from the 192 and 122 days, respectively, observed in the placebo group. Additional retrospective analyses of sex and stage revealed no beneficial effect of tamoxifen upon survival. For women in stage III (any T N1 M0), mean and median survivals were 255 and 191 days, respectively, compared with values of 84 and 45 days, respectively, in the placebo group (P = 0.011). After 2.5 years, three (7 per cent) women in the tamoxifen group were still alive compared with no survivors in the placebo group. No male patients survived beyond 2.5 years. This therapeutic result in a small subgroup of women is probably incidental and not an effect of tamoxifen.


Asunto(s)
Adenocarcinoma/tratamiento farmacológico , Ampolla Hepatopancreática/patología , Neoplasias del Conducto Colédoco/tratamiento farmacológico , Neoplasias Pancreáticas/tratamiento farmacológico , Tamoxifeno/uso terapéutico , Adenocarcinoma/mortalidad , Adenocarcinoma/patología , Anciano , Neoplasias del Conducto Colédoco/mortalidad , Neoplasias del Conducto Colédoco/patología , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Neoplasias Pancreáticas/mortalidad , Neoplasias Pancreáticas/patología , Ensayos Clínicos Controlados Aleatorios como Asunto , Tasa de Supervivencia
18.
Tidsskr Nor Laegeforen ; 112(7): 872-5, 1992 Mar 10.
Artículo en Nor | MEDLINE | ID: mdl-1557752

RESUMEN

The Norwegian national register for total hip replacements collects data on the total hip arthroplasties performed in Norway. 17,444 operations were registered from the start i September 1987 and through 1990. The age of the patients ranged from 12 til 97 years. The median was 69 years. 69% of the patients were females. The operating-time ranged from 25 to 420 minutes, with a median of 100 minutes. Cemented prostheses constituted 83% and uncemented prostheses 17% of the market. The Charnley prosthesis dominated, and was used in 49% of all implants. 13% of all operations were revisions. During these three and a half years, 0.9% of the cemented prostheses and 2.9% of the noncemented prostheses were revised (P less than 0.001).


Asunto(s)
Prótesis de Cadera/estadística & datos numéricos , Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Noruega/epidemiología , Diseño de Prótesis , Sistema de Registros , Reoperación
19.
Acta Orthop Scand ; 65(1): 1-6, 1994 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8154270

RESUMEN

In the Norwegian Arthroplasty Register, 15,335 primary total hip replacements (THR) in patients with primary arthrosis were followed for 0-5.4 years. The Kaplan-Meier estimate of cumulative failure (revision) after 4.5 years was 2.7 percent for cemented THR, compared to 6.5 percent for uncemented. In patients under 65 years the cumulative revisions for cemented and uncemented THR were 3.3 and 7.9 percent. For the acetabular components, the cumulative failures were 0.6 percent for cemented and 1.7 percent for uncemented, and for femoral components 1.7 and 3.9 percent after 4.5 years. Adjusting for age and sex using a Cox regression model, 2 times higher rates of failure were found comparing uncemented to cemented THR. The results for uncemented prostheses were more unfavorable in young patients. In men and women under 60, the revision rates were increased 6 and 3 times, respectively, for patients with uncemented THR compared to those with cemented THR. Restriction of the end-point to revision for aseptic loosening gave results similar to the over-all results. No difference between cemented and uncemented THR was seen for revisions due to infection, whereas the most unfavorable results for uncemented THR were seen when revisions due to causes other than infection and aseptic loosening were considered.


Asunto(s)
Cementos para Huesos/uso terapéutico , Cementación , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Sistema de Registros , Adulto , Factores de Edad , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Noruega , Modelos de Riesgos Proporcionales , Falla de Prótesis , Análisis de Regresión , Reoperación , Factores Sexuales , Factores de Tiempo
20.
Ann Surg ; 209(4): 418-23, 1989 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-2930287

RESUMEN

One thousand one hundred and twenty-eight patients treated for perforated gastroduodenal ulcer during the years 1935-1985 were studied at the Haukeland University Hospital. The majority of patients (97.7%) were treated surgically. The data was analyzed by contingency tables and chi square testing, and a stepwise logistic regression analysis was performed in order to reveal interactions between variables and to elucidate time trends in lethality rates. The total postperforation lethality was 7.4%, the postsurgical death rate was 6.6%, and the death rate among conservatively treated patients was 42.3%. Lethality was significantly influenced by year of hospital admission and increased markedly with the age of the patients. For all age groups, the lethality decreased markedly with time. Treatment delay was associated with a moderate but significant increase in lethality. In patients with gastric ulcer the lethality was 3.6 times higher than in those with duodenal ulcer. The death rate was similar in the duodenal and pyloric ulcer groups. Death rate decreased with time in both stomach ulcer, duodenal, and pyloric ulcer patients. There was no sex difference and no difference between patients treated with simple suture or gastric resection.


Asunto(s)
Úlcera Duodenal/complicaciones , Úlcera Péptica Perforada/mortalidad , Úlcera Gástrica/complicaciones , Úlcera Duodenal/mortalidad , Femenino , Humanos , Masculino , Noruega , Úlcera Péptica Perforada/cirugía , Análisis de Regresión , Estudios Retrospectivos , Úlcera Gástrica/mortalidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda