Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
2.
Clin Vaccine Immunol ; 16(7): 1091-2, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19458205

RESUMEN

The CDC recommends that a reactive rapid human immunodeficiency virus (HIV) test be confirmed with an approved supplemental test; the performance of an intermediate enzyme immunoassay (EIA) is optional. In support of this recommendation, it was found that of 1,431 reactive rapid HIV test results, 2 (0.1%) had false-negative oral fluid Western blot results and both had false-negative EIA results.


Asunto(s)
Infecciones por VIH/diagnóstico , VIH/inmunología , Boca/inmunología , Humanos , Técnicas para Inmunoenzimas/métodos
3.
Cytometry ; 13(1): 68-74, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1372204

RESUMEN

We studied the effects of anticoagulants and cell preparation methods on lymphocyte forward-angle scatter (FSC), autofluorescence, and immunofluorescent staining for CD45, CD14, and CD13. Blood samples collected in ethylenediaminetetracetic acid (EDTA), heparin, and acid citrate dextrose (ACD) were processed by using conventional Hypaque-Ficoll (HF) separation and four whole blood (WB) lysis techniques: Immuno-lyse, Q-Prep, FACS Lyse, and Gen Trak Lysis. Lymphocytes prepared by using three of the four whole blood methods gave FCS values comparable to those isolated by HF, while one method (FACS Lyse) gave consistently lower values. Autofluorescence values were comparable by all methods except Immuno-lyse, which showed consistently higher values in blood stored for 24 h with any anticoagulant. Immunofluorescent values for CD45-stained cells were quite consistent across all methods, and among the whole blood methods, FACS Lyse and Q-Prep uniformly gave the highest purity of CD45-positive cells in the lymphocyte light scatter gates. Additionally, propidium iodide (PI) analyses of CD45-stained whole blood, and analyzed without lysis, confirmed that ACD and heparin were superior to EDTA for maintaining viable leucocytes overnight. Future studies should focus on other commonly used reagents, a wide variety of abnormal samples, and cell viability.


Asunto(s)
Análisis Químico de la Sangre , Conservación de la Sangre , Ácido Cítrico , Citometría de Flujo , Hemólisis , Antígenos CD/análisis , Antígenos de Diferenciación Mielomonocítica/análisis , Antígenos CD13 , Ácido Edético , Glucosa/análogos & derivados , Heparina , Antígenos de Histocompatibilidad/análisis , Humanos , Antígenos Comunes de Leucocito , Luz , Receptores de Lipopolisacáridos , Propidio , Dispersión de Radiación
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda