1.
J Med Virol ; 96(1): e29365, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38185981

RESUMEN

Studies about the duration of the humoral and cellular response following the bivalent booster administration are still scarce. We aimed at assessing the humoral and cellular response in a cohort of healthcare workers that received this booster. Blood samples were collected before the administration of the bivalent booster from Pfizer-BioNTech and after 14, 28, 90, and 180 days. Neutralizing antibodies against either the D614G strain, the delta variant, the BA.5 variant, or the XBB.1.5 subvariant were measured. The cellular response was assessed by measurement of the release of interferon gamma from T cells in response to an in vitro SARS-CoV-2 stimulation. A substantial waning of neutralizing antibodies was observed after 6 months (23.1-fold decrease), especially considering the XBB.1.5 subvariant. The estimated T1/2 of neutralizing antibodies was 16.1 days (95% CI = 10.2-38.4 days). Although most participants still present a robust cellular response after 6 months (i.e., 95%), a significant decrease was also observed compared to the peak response (0.95 vs. 0.41 UI/L, p = 0.0083). A significant waning of the humoral and cellular response was observed after 6 months. These data can also help competent national authorities in their recommendation regarding the administration of an additional booster.


Asunto(s)
Vacuna BNT162 , Terapias Complementarias , Humanos , Inmunidad Celular , Anticuerpos Neutralizantes , Personal de Salud
2.
J Med Virol ; 95(1): e28164, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36131356

RESUMEN

Evidence about the long-term persistence of the booster-mediated immunity against Omicron is mandatory for pandemic management and deployment of vaccination strategies. A total of 155 healthcare professionals (104 COVID-19 naive and 51 with a history of SARS-CoV-2 infection) received a homologous BNT162b2 booster. Binding antibodies against the spike protein and neutralizing antibodies against Omicron were measured at several time points before and up to 6 months after the booster. Geometric mean titers of measured antibodies were correlated to vaccine efficacy (VE) against symptomatic disease. Compared to the highest response, a significant 10.2- and 11.5-fold decrease in neutralizing titers was observed after 6 months in participants with and without history of SARS-CoV-2 infection. A corresponding 2.5- and 2.9-fold decrease in binding antibodies was observed. The estimated T1/2 of neutralizing antibodies in participants with and without history of SARS-CoV-2 infection was 42 (95% confidence interval [CI]: 25-137) and 36 days (95% CI: 25-65). Estimated T1/2 were longer for binding antibodies: 168 (95% CI: 116-303) and 139 days (95% CI: 113-180), respectively. Both binding and neutralizing antibodies were strongly correlated to VE (r = 0.83 and 0.89). However, binding and neutralizing antibodies were modestly correlated, and a high proportion of subjects (36.7%) with high binding antibody titers (i.e., >8434 BAU/ml) did not have neutralizing activity. A considerable decay of the humoral response was observed 6 months after the booster, and was strongly correlated with VE. Our study also shows that commercial assays available in clinical laboratories might require adaptation to better predict neutralization in the Omicron era.


Asunto(s)
COVID-19 , Vacunas , Humanos , Anticuerpos Neutralizantes , Vacuna BNT162 , COVID-19/prevención & control , SARS-CoV-2 , Anticuerpos Antivirales
3.
Clin Chem Lab Med ; 61(8): 1420-1427, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-36785905

RESUMEN

OBJECTIVES: The aim of this study was to compare the results of five methods for the determination of total 25(OH)D. For that purpose, two mass spectrometry and three immunoassay methods were used. METHODS: A total of 124 serum samples were analyzed on five different methods (i.e., a reference LC-MS/MS, Cascadion, Lumipulse, Roche Elecsys II and Roche Elecsys III). Analytical performance against LC-MS/MS was evaluated and compared to the Milan models 1 (analytical performance based on the clinical outcome using thresholds of 12, 20 and 30 ng/mL) and 2 (analytical performance based on biological variation). Additionally, imprecision studies and accuracy using NIST SRM972a samples were carried out. RESULTS: Compared to the reference LC-MS/MS method, the Lumipulse and the Roche Elecsys III assays reached the optimal criterion for bias, while the Cascadion met the desirable one. The Roche Elecsys II was not able to reach the minimal criteria. The proportion of correctly classified patients was higher using the Cascadion (95.2%) compared to the three immunoassays. In addition to its better precision, the Cascadion was not impacted by a high concentration of 3-epi-25(OH)D3 compared to the three immunoassays. CONCLUSIONS: Compared to the LC-MS/MS reference method, the Cascadion presented the highest level of concordance at medical decision cut-offs for total 25(OH)D and reached the desirable specification for bias. Moreover, the presence of 3-epi-25(OH)D3 in enriched samples was only problematic in immunoassay methods, and especially considering Roche Elecsys methods. The release of performant fully automated mass spectrometry assays with high throughput might therefore facilitate the wide scale adoption of LC-MS/MS, even in non-specialized clinical laboratories.


Asunto(s)
Espectrometría de Masas en Tándem , Vitamina D , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Inmunoensayo/métodos
4.
Clin Chem Lab Med ; 61(3): 427-434, 2023 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-36420543

RESUMEN

OBJECTIVES: Alpha-1 antitrypsin (A1AT) deficiency was first identified in patients with emphysema by the absence of the α1 band on serum protein electrophoresis (SPE). Today, capillary zone electrophoresis is widely performed in laboratories. Here, we compared two SPE systems to detect decreased A1AT concentrations to optimize their use as a screening tool for A1AT deficiency. METHODS: Serum protein electrophoresis was performed on 200 samples on the Capillarys 2 and the V8 Nexus. The latter presents two α1 bands (α1 band 1 and 2) while the Capillarys 2 has only one (Capillarys 2 total α1). The measures of A1AT and α1 acid glycoprotein (AAG) were performed as well as the phenotyping of M, S and Z alleles. RESULTS: At a A1AT cutoff of 0.80 g/L, a cutoff of 1.21 g/L using the V8 Nexus α1 band 2 corresponded to a 100% sensitivity and a 92.4% specificity while a 1.69% cutoff corresponded to a 100% sensitivity and a 92.4% specificity. The performance of the α1 band 1 was suboptimal and rather corresponded to AAG. On the Capillarys 2, a cutoff of 2.0 g/L corresponded to a 75.0% sensitivity and a 86.6% specificity, while a 3.2% cutoff showed a 96.4% sensitivity and a 67.4% specificity. The V8 Nexus α1 band 2 was the method the most correlated with A1AT (r=0.90-0.94). CONCLUSIONS: The V8 Nexus α1 band 2 was the best predictor of A1AT deficiency, probably owing to a better resolution. The use of SPE was however unable to predict each phenotype. Phenotype or genotype studies are therefore still advisable in case of A1AT deficiency.


Asunto(s)
Deficiencia de alfa 1-Antitripsina , Humanos , Deficiencia de alfa 1-Antitripsina/genética , alfa 1-Antitripsina/genética , Genotipo , Fenotipo , Electroforesis Capilar
5.
Clin Chem Lab Med ; 61(5): 811-821, 2023 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-36420539

RESUMEN

This review is an integral part of the special issue for the 60 years of the journal Clinical Chemistry and Laboratory Medicine (CCLM). The aim of the review is to highlight the role of the clinical laboratory since the emergence of the "severe acute respiratory syndrome coronavirus 2" (SARS-CoV-2), which causes Coronavirus disease 2019 (COVID-19), with special focus on the contribution of the journal in generating knowledge in SARS-CoV-2 diagnosis. As of October 30, 2022, a total of 186 CCLM publications were dedicated to COVID-19. Of importance, major International Federation of Clinical Chemistry (IFCC) guidelines related to the diagnosis of COVID-19 were published in CCLM. Between early-2020 and late October 2022, COVID-19 publications represented around 27% of all articles in CCLM, highlighting the willingness of the editorial board to help the field in order to better describe and diagnose this new emerging disease. First launched in 1963 under the name "Zeitschrift für Klinische Chemie", the Journal was entirely devoted to clinical chemistry in the strict sense. The various topics published in relation to COVID-19 including its diagnosis, its impact on biochemical or hematological measures, as well as biosafety measures, is the perfect example that shows that the journal has greatly diversified over time.


Asunto(s)
COVID-19 , Servicios de Laboratorio Clínico , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Química Clínica
6.
Clin Chem Lab Med ; 61(9): 1670-1675, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-36999398

RESUMEN

OBJECTIVES: The BNT162b2 messenger RNA vaccine is highly effective in reducing COVID-19 infection, hospitalization and death. However, many subjects developed a breakthrough infection despite a full vaccination scheme. Since the waned efficacy of mRNA vaccines is correlated with the decrease of antibodies occurring over time, we aimed at evaluating whether lower levels of antibodies were associated with an increased risk of breakthrough infection in a cohort of breakthrough subjects that received three vaccine doses. METHODS: Total binding antibodies against the RBD of the S1 subunit (Roche Diagnostics, Machelen, Belgium) and neutralizing antibodies using the Omicron B.1.1.529 variant pseudovirus were measured. Based on individual kinetic curves, the antibody titer of each subject was interpolated just before the breakthrough infection and compared to a matched-control group that did not develop a breakthrough infection. RESULTS: Lower levels of total binding and neutralizing antibodies were observed compared to the control group (6.900 [95% CI; 5.101-9.470] vs. 11.395 BAU/mL [8.627-15.050] [p=0.0301] and 26.6 [18.0-39.3] vs. 59.5 dilution titer-1 [32.3-110] [p=0.0042], respectively). The difference between breakthrough and control subjects was mostly observed for neutralizing antibodies before three months after the homologous booster administration (46.5 [18.2-119] vs. 381 [285-509] [p=0.0156]). Considering the measurement of total binding antibodies before 3 months, there was no significant difference (p=0.4375). CONCLUSIONS: In conclusion, our results showed that subjects that developed a breakthrough infection had lower levels of neutralizing and total binding antibodies compared to controls. The difference was mostly noticeable considering neutralizing antibodies, especially for infections occurring before 3 months after the booster administration.


Asunto(s)
COVID-19 , Humanos , Infección Irruptiva , Vacuna BNT162 , Anticuerpos Neutralizantes , Atención a la Salud , Anticuerpos Antivirales
7.
Clin Chem Lab Med ; 61(10): 1875-1885, 2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37078220

RESUMEN

OBJECTIVES: To assess the long-term humoral immunity induced by booster administration, as well as the ability of binding antibody and surrogate virus neutralization tests (sVNT) to predict neutralizing antibodies (NAbs) against the SARS-CoV-2 Omicron variant. METHODS: A total of 269 sera samples were analyzed from 64 healthcare workers who had received a homologous booster dose of BNT162b2. Neutralizing antibodies assessed by sVNT and anti-RBD IgG measured with the sCOVG assay (Siemens Healthineers®) were analyzed at five timepoints; before and up to 6 months following the booster. Antibody titers were correlated with neutralizing antibodies against the Omicron BA.1 variant obtained by pseudovirus neutralization test (pVNT) as a reference method. RESULTS: While Wild-type sVNT percentage of inhibition (POI) remained above 98.6% throughout the follow-up period after booster administration, anti-RBD IgG and NAbs assessed by Omicron BA.1 pVNT showed respectively a 3.4-fold and 13.3-fold decrease after 6 months compared to the peak reached at day 14. NAbs assessed by Omicron sVNT followed a steady decline until reaching a POI of 53.4%. Anti-RBD IgG and Omicron sVNT assays were strongly correlated (r=0.90) and performed similarly to predict the presence of neutralizing antibodies with Omicron pVNT (area under the ROC: 0.82 for both assays). In addition, new adapted cut-off values of anti-RBD IgG (>1,276 BAU/mL) and Omicron sVNT (POI>46.6%) were found to be better predictors of neutralizing activity. CONCLUSIONS: This study showed a significant drop in humoral immunity 6 months after booster administration. Anti-RBD IgG and Omicron sVNT assays were highly correlated and could predict neutralizing activity with moderate performance.


Asunto(s)
Anticuerpos Neutralizantes , COVID-19 , Humanos , SARS-CoV-2 , Pruebas de Neutralización , Vacuna BNT162 , Cinética , Inmunoglobulina G , Anticuerpos Antivirales
8.
Clin Chem Lab Med ; 60(2): 229-234, 2022 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-34751528

RESUMEN

OBJECTIVES: Carbamylation is a non-enzymatic post-translational reaction of a primary amino group of a protein with isocyanate. The albumin carbamylation is a negative prognostic factor in chronic kidney disease (CKD) patients and induce charge difference implying an observed shift in electrophoretic mobility that can be measured through a symmetry factor (SF). METHODS: The Helena V8 and the Sebia Capillarys 2 systems were used for all experiments. The effect of in vitro carbamylation on the SF by spiking increasing concentrations of potassium isocyanate (KCNO) in serum of three healthy volunteers was investigated. Theoretical plate numbers (N) as a surrogate of separation efficiency were also calculated and correlations between SF and renal function biomarkers were performed on 284 patients. RESULTS: A dose-dependent impact of KCNO on the SF was observed for both methods with the Helena V8 being more sensitive. The mean N was significantly higher on the Helena V8 as compared to the Sebia Capillarys 2 (2,972 vs. 444.1, p<0.0001). The SF correlated significantly with eGFR (r=0.50, p<0.0001), creatinine (r=-0.31, p<0.0001) and urea (r=-0.34, p<0.0001) on the Helena V8. On the Sebia Capillarys 2, a significant correlation was only observed with eGFR (r=0.17, p=0.004). A better discrimination between CKD stages was also observed using the Helena V8. CONCLUSIONS: Thanks to a higher mean N, the Helena V8 might offer new possibilities, including detection of carbamylated albumin through SF calculation. Further studies are still needed to confirm the interest of using this type of assays in clinical routine.


Asunto(s)
Electroforesis Capilar , Insuficiencia Renal Crónica , Albúminas , Creatinina , Electroforesis Capilar/métodos , Humanos , Insuficiencia Renal Crónica/diagnóstico , Urea
9.
Clin Chem Lab Med ; 60(6): 808-820, 2022 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-35304841

RESUMEN

Immunoassays are currently the methods of choice for the measurement of a large panel of complex and heterogenous molecules owing to full automation, short turnaround time, high specificity and sensitivity. Despite remarkable performances, immunoassays are prone to several types of interferences that may lead to harmful consequences for the patient (e.g., prescription of an inadequate treatment, delayed diagnosis, unnecessary invasive investigations). A systematic search is only performed for some interferences because of its impracticality in clinical laboratories as it would notably impact budget, turnaround time, and human resources. Therefore, a case-by-case approach is generally preferred when facing an aberrant result. Hereby, we review the current knowledge on immunoassay interferences and present an algorithm for interference workup in clinical laboratories, from suspecting their presence to using the appropriate tests to identify them. We propose an approach to rationalize the attitude of laboratory specialists when faced with a potential interference and emphasize the importance of their collaboration with clinicians and manufacturers to ensure future improvements.


Asunto(s)
Algoritmos , Automatización , Humanos , Inmunoensayo/métodos
10.
Clin Chem Lab Med ; 60(7): 975-981, 2022 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-35452576

RESUMEN

This document, endorsed by the IFCC Working Group on SARS-CoV-2 Variants, aims to update previous indications for diagnosing acute SARS-CoV-2 infection, taking into consideration the evidence that has emerged after the origin and spread of new lineages and sub-lineages of the virus characterized by mutated genetics and altered biochemical, biological and clinical characteristics. These indications encompass the use of different diagnostic strategies in specific clinical settings, such as high risk of SARS-CoV-2 infection (symptomatic patients), low risk of SARS-CoV-2 infection (asymptomatic subjects) at hospital admission/contact tracing, testing in asymptomatic subjects, in epidemiologic surveys and/or population screening, along with tentative indications for identification of new lineages and/or sub-lineages of SARS-CoV-2.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , SARS-CoV-2/genética
11.
Clin Chem Lab Med ; 60(10): 1598-1606, 2022 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-35849629

RESUMEN

OBJECTIVES: The high request for vitamin D testing in the last decades has led manufacturers to develop assays on automated immunoassay platforms. The objective of this study was to evaluate the performance of the new Elecsys Vitamin D total III assay for the measurement of total 25(OH)D. METHODS: A total of 844 serum samples collected in two clinical laboratories were used to evaluate the new Roche Elecsys Vitamin D total III assay. Comparisons with Roche Elecsys Vitamin D total II and liquid chromatography tandem mass spectrometry (LC-MS/MS) were carried out. Additionally, assay imprecision, linearity, matrix effects, biotin interference, cross-reactivity with 24,25(OH)2D3 and 3-epi-25(OH)D3, and outlier rate were evaluated for the Elecsys Vitamin D total III assay. RESULTS: Only the comparison between LC-MS/MS and Roche Elecsys Vitamin D total III achieved the optimal specification for bias (i.e., <3.4%). Imprecision, linearity and matrix effects showed acceptable results. The biotin interference threshold was increased up to 1,200 ng/mL and the outlier rate was low (0.26%). The cross-reactivity with 24,25(OH)2D3 and 3-epi-25(OH)D3 was weak or modest in available patient samples. However, using SRM972a with a high level of 3-epi-25(OH)D3 (enriched) revealed an important cross-reactivity with both Roche Elecsys Vitamin D total II and III assays (+74.7% and +73.7%). CONCLUSIONS: In conclusion, the Roche Elecsys Vitamin D total III assay presents several advantages compared to the previous assay generation: higher biotin interference threshold, broader measuring range, and better comparability with LC-MS/MS. However, the cross-reactivity toward 3-epi-25(OH)D3 is still problematic in high titer samples.


Asunto(s)
Espectrometría de Masas en Tándem , Vitamina D , Biotina , Cromatografía Liquida , Humanos , Inmunoensayo , Vitaminas
12.
J Med Virol ; 93(2): 803-811, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32667733

RESUMEN

The development of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serological tests is massive. The external validation of their performance is needed before use in clinical routine practice. Our study aims at assessing the analytical and clinical performance of two enzyme-linked immunosorbent assay tests detecting antibodies directed against the virus nucleocapsid protein: The NovaLisa SARS-CoV-2 immunoglobulin G (IgG), immunoglobulin A (IgA), and immunoglobulin M (IgM) test (NovaTec) allowing a separate detection of each antibody and the Platelia SARS-CoV-2 Total Ab test (Bio-Rad) detecting total antibodies (IgM, IgA, and IgG). Two-hundred and eight coronavirus disease 2019 samples from 48 quantitative reverse transcription-polymerase chain reaction (RT-qPCR) confirmed patients were used to perform the sensitivity analysis. Non-SARS-CoV-2 sera (n = 79) with a potential cross-reaction to SARS-CoV-2 immunoassays were included in the specificity analysis. In addition, using receiver operator characteristic curves, adapted cut-off for improvement of the performances were proposed. The kinetics of these antibodies was also assessed over 8 weeks. Two weeks after the RT-qPCR positive detection, the NovaLisa test shows a sensitivity and specificity of 94.9% (95% confidence interval [CI]: 83.1%-98.6%) and 96.2% (95% CI: 89.4%-98.7%) for IgG, of 89.7% (95% CI: 76.4%-95.9%) and 98.7% (95% CI: 93.2%-98.8%) for IgA, and of 48.7% (95% CI: 33.9%-63.8%) and 98.7% (95% CI: 93.2%-99.8%) for IgM. With the Platelia system, the specificity and sensitivity were 97.4% (95% CI: 92.1%-99.7%) and 94.9% (95% CI: 87.7%-98.0%) for total antibodies using the adapted cut-offs. The NovaLisa and the Platelia tests have satisfactory analytical performances. The clinical performances are excellent for IgG, IgA, and total antibodies especially if the cut-off is optimized.


Asunto(s)
Anticuerpos Antivirales/sangre , COVID-19/diagnóstico , Ensayo de Inmunoadsorción Enzimática/normas , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , SARS-CoV-2/inmunología , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/inmunología , COVID-19/mortalidad , COVID-19/virología , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2/patogenicidad , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Análisis de Supervivencia
13.
J Med Virol ; 93(4): 2262-2269, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33200836

RESUMEN

This study assesses the clinical performance of three anti-SARS-CoV-2 assays, namely EUROIMMUN anti-SARS-CoV-2 nucleocapsid (IgG) ELISA, Elecsys anti-SARS-CoV-2 nucleocapsid (total antibodies) assay, and LIAISON anti-SARS-CoV-2 spike proteins S1 and S2 (IgG) assay. One hundred and thirty-seven coronavirus disease 2019 (COVID-19) samples from 96 reverse-transcription polymerase chain reaction confirmed patients were chosen to perform the sensitivity analysis. Non-SARS-CoV-2 sera (n = 141) with a potential cross-reaction to SARS-CoV-2 immunoassays were included in the specificity analysis. None of these tests demonstrated a sufficiently high clinical sensitivity to diagnose acute infection. Fourteen days since symptom onset, we did not find any significant difference between the three techniques in terms of sensitivities. However, Elecsys performed better in terms of specificity. All three anti-SARS-CoV-2 assays had equivalent sensitivities 14 days from symptom onset to diagnose past-COVID-19 infection. We also confirmed that anti-SARS-CoV-2 determination before Day 14 is of less clinical interest.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/sangre , COVID-19/virología , Proteínas de la Nucleocápside de Coronavirus/sangre , Inmunoensayo/métodos , SARS-CoV-2/aislamiento & purificación , Glicoproteína de la Espiga del Coronavirus/sangre , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Antivirales/sangre , COVID-19/diagnóstico , COVID-19/inmunología , Proteínas de la Nucleocápside de Coronavirus/inmunología , Reacciones Cruzadas , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , Fosfoproteínas/sangre , Fosfoproteínas/inmunología , Estudios Retrospectivos , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus/análisis , Glicoproteína de la Espiga del Coronavirus/inmunología
14.
J Med Virol ; 93(5): 3277-3281, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33599299

RESUMEN

Following the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic, numerous serological tests have been developed, including rapid diagnostic tests. This study aims at assessing the clinical performance of the Panbio immunoglobulin G (IgG)/IgM coronavirus disease 2019 (COVID-19) test (Abbott), a rapid lateral flow assay for the qualitative detection of IgG and IgM against SARS-CoV-2. One hundred and thirty-eight samples from 95 COVID-19 patients with a positive SARS-CoV-2 reverse-transcriptase polymerase chain reaction were analyzed to assess the clinical sensitivity. Seventy-six pre-COVID-19 samples were used to evaluate the clinical specificity. Two independent and blinded raters determined visually the presence or absence of the IgG, IgM, and control lines for each test after 10 and 20 min. The sensitivity obtained from collected samples more than 14 days after the onset of symptoms was 95.2% for IgG. IgM was less frequently detected (highest sensitivity of 20.5%). The specificities obtained were 98.7% and 100% for IgG and IgM, respectively. In addition, the sensitivity of the assay was better when the reading was performed at 20 min than at 10 min, whereas the specificity was unchanged. The Panbio COVID-19 IgG/IgM rapid test detects IgG with high sensitivity 14 days since symptom onset but presents a low sensitivity for IgM. The specificity was excellent for both IgG and IgM.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , Inmunoensayo/métodos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , SARS-CoV-2 , COVID-19/sangre , COVID-19/inmunología , Humanos
15.
Clin Endocrinol (Oxf) ; 94(5): 845-850, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33107075

RESUMEN

BACKGROUND: Interpretation of thyroid function tests by means of biological variation (BV) data is essential to identify significant changes between serial measurements at an individual level. Data on thyroid parameters in adults are limited. OBJECTIVES: We aimed at determining the BV of four thyroid function test (thyroid-stimulating hormone (TSH), free thyroxin (FT4), free triiodothyronine (FT3) and thyroglobulin (Tg)) by applying recent recommendations to acquire BV data on a latest generation of immunoassay. METHODS: Nineteen healthy volunteers (8 males and 11 females) were drawn every week during 5 consecutive weeks. Samples were analysed in duplicate on the Cobas 602 analyzer (Roche Diagnostics). After normality assessment, outlier exclusion and homogeneity of variance analysis, analytical variation (CVA ), within-subject biological variation (CVI ) and between-subject biological variation (CVG ) were determined using nested ANOVA. RESULTS: CVA , CVI and CVG were 0.9%, 19.7% and 37.6% for TSH; 3.6%, 4.6% and 10.8% for FT4; 2.2%, 6.0% and 8.6% for FT3; and 0.9%, 15.4% and 84.9% for Tg. Index of individuality (II) for all parameters was between 0.2 and 0.7. The percentage above which the change between two measures is truly significant (reference change value) was 54.7% for TSH, 16.2% for FT4, 17.7% for FT3 and 42.8% for Tg. CONCLUSION: Based on recent international recommendations, our study provides updated BV data for four thyroid function tests in European healthy volunteers. Reliable BV characteristics, and especially RCV, can facilitate the interpretation of consecutive thyroid function tests in an individual and therefore have the potential to efficiently support clinical decisions regarding thyroid diseases.


Asunto(s)
Objetivos , Glándula Tiroides , Adulto , Biomarcadores , Femenino , Voluntarios Sanos , Humanos , Masculino , Valores de Referencia , Tirotropina , Tiroxina , Triyodotironina
16.
Clin Chem Lab Med ; 59(7): 1201-1211, 2021 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-33554552

RESUMEN

Cardiac troponins (cTn) are the preferred biomarkers for the evaluation of myocardial injury and play a key role in the diagnosis of acute myocardial infarction (MI). Pre-analytical or analytical issues and interferences affecting troponin T and I assays are therefore of major concern given the risk of misdiagnosis. False positive troponin results have been related to various interferences including anti-troponin antibodies, heterophilic antibodies, or elevated alkaline phosphatase level. On the other hand, false negative results have been reported in the case of a large biotin intake. These interferences are characterized with erroneous but reproducible troponin results. Of interest, non-reproducible results have also been reported in the literature. In other words, if the sample is reanalyzed a second time, a significant difference in troponin results will be observed. These interferences have been named "fliers" or "outliers". Compared to the biotin interference that received major attention in the literature, troponin outliers are also able to induce harmful clinical consequences for the patient. Moreover, the prevalence of outliers in recent studies was found to be higher (0.28-0.57%) compared to the biotin interference. The aim of this systematic review is to warn clinicians about these non-reproducible results that may alter their clinical judgment. Four case reports that occurred in the Clinique of Saint-Luc Bouge are presented to attest this point. Moreover, we aimed at identifying the nature of these non-reproducible troponin results, determining their occurrence, and describing the best way for their identification.


Asunto(s)
Infarto del Miocardio , Troponina I , Biomarcadores , Biotina , Humanos , Infarto del Miocardio/diagnóstico , Troponina T
17.
Clin Chem Lab Med ; 59(5): 971-978, 2021 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-33554567

RESUMEN

OBJECTIVES: Accurate SARS-CoV-2 serological assays are urgently needed to help diagnose infection, determine past exposure of populations and assess the response to future vaccines. The study aims at assessing the performance of the multiplex D-tek COVIDOT 5 IgG assay for the detection of SARS-CoV-2 IgG antibodies (N, S1+S2, S1, S2 and RBD). METHODS: Sensitivity and dynamic trend to seropositivity were evaluated in 218 samples obtained from 46 rRT-PCR confirmed COVID-19 patients. Non-SARS-CoV-2 sera (n=118) collected before the COVID-19 pandemic with a potential cross-reaction to the SARS-CoV-2 immunoassay were included in the specificity analysis. RESULTS: A gradual dynamic trend since symptom onset was observed for all IgG antibodies. Sensitivities before day 14 were suboptimal. At ≥21 days, sensitivities reached 100% (93.4-100%) for N, S1+S2, S2 and RBD-directed IgG and 96.3% (87.3-99.6%) for S1-directed IgG. In 42 out of 46 patients (91.3%), all five antibodies were detected at ≥14 days. The four remaining patients had between 2 and 4 positive antibodies at their respective maximal follow-up period. The specificity was 100 % for S1+S2, S2 and RBD, 98.3% for N and 92.4% (86.0-96.5%) for S1-directed IgG. The combined use of antigens increases the early sensitivity whilst enforcing high specificity. CONCLUSIONS: Sensitivities at ≥21 days and specificities were excellent, especially for N, S1+S2, S2 and RBD-directed IgG. Caution is however required when interpreting single S1-directed reactivities. Using a multiplex assay complies with the orthogonal testing algorithm of the CDC and allows a better and critical interpretation of the serological status of a patient.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Inmunoensayo/métodos , Inmunoglobulina G/sangre , SARS-CoV-2/inmunología , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Antivirales/inmunología , COVID-19/sangre , Femenino , Humanos , Inmunoglobulina G/inmunología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
18.
Clin Chem Lab Med ; 58(12): 2037-2045, 2020 11 26.
Artículo en Inglés | MEDLINE | ID: mdl-32324155

RESUMEN

Background Biotin is currently a matter of concern for laboratories using biotin-streptavidin-based immunoassays. Biotin interferences have been reported for high-sensitive troponin T (hsTnT) and thyroid-stimulating hormone (TSH) assays. We aimed to evaluate the new generation of hsTnT and TSH electrochemiluminescent immunoassays announced to be less sensitive to biotin. Methods Firstly, we assessed the analytical performances of new generation assays (imprecision, bias, total error, limit of quantification) and compared previous and new generation assays in the absence of biotin. Secondly, we challenged both generations of assays with samples spiked with seven different biotin levels. The efficiency of new generation assays was also compared to the streptavidin beads treatment. Results New generation assays presented suitable analytical performances. Previous and new generations of hsTnT and TSH assays were commutable in the absence of biotin. In the presence of biotin, we confirmed that previous generation assays were affected by biotin concentration as low as 40.5 ng/mL and that new generation assays were not affected up to the announced tolerance threshold of 1200 ng/mL. After the streptavidin beads treatment, we observed a higher imprecision for both parameters and a constant 10% negative bias for TSH compared to new generation assays. Conclusions New generation of electrochemiluminescent immunoassays appears as a reliable systematic solution to prevent biotin interference for hsTnT and TSH testing.


Asunto(s)
Inmunoensayo/métodos , Tirotropina/análisis , Troponina T/análisis , Artefactos , Biotina/química , Técnicas Electroquímicas/métodos , Humanos , Pruebas Inmunológicas , Estreptavidina , Pruebas de Función de la Tiroides
19.
Clin Chem Lab Med ; 58(3): 408-415, 2020 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-31665115

RESUMEN

Background The correct identification of the macro-B12 interference (macroforms) is paramount to avoid potential erroneous clinical decisions. Our objectives were to determine whether immunoassays are affected by the presence of macro-B12 and to validate a polyethylene glycol (PEG) precipitation procedure to detect it. Methods Sixty-two serum samples obtained from healthy volunteers were analyzed to determine recovery and reference intervals (RIs) following PEG precipitation. Thereafter, 50 serum samples with very high levels of B12 (>1476 pmol/L) were randomly selected to search for macro-B12 interferences. Serum samples obtained from healthy volunteers and related PEG aliquots were analyzed on a Cobas® immunoassay. Patients' samples were analyzed on both Cobas® and Architect® immunoassays. Finally, samples suspected to contain macro-B12 were analyzed by size-exclusion chromatography (SEC) to confirm the presence of macro-B12. Results Recovery and post-PEG RIs determined on a Cobas 8000® in healthy volunteers ranged from 68.3% to 108.4% and from 122.1 to 514.4 pmol/L, respectively. Fifteen samples (30%) were found to show macro-B12 while using the recovery criteria, and nine samples (18%) while using the post-PEG RI. The other immunoassay ran on the Architect i2000® was also affected by the presence of macro-B12. Size-exclusion chromatography studies confirmed the presence of macro-B12 (immunoglobulin-B12 complexes). Conclusions The prevalence of macro-B12 in elevated B12 samples is high. We suggest to systematically screen for the presence of macro-B12 with PEG precipitation procedure in samples with elevated B12 levels to avoid potential misdiagnosis or harmful clinical consequences.


Asunto(s)
Análisis Químico de la Sangre , Vitamina B 12/sangre , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
SELECCIÓN DE REFERENCIAS