RESUMEN
BACKGROUND: We examined the use of [18F]FDG-PET/CT for the diagnosis of native valve endocarditis (NVE). METHODS: PET/CT images in patients with suspected NVE were retrospectively reviewed independently by two experienced physicians blinded to all clinical information. The gold standard consisted of surgical findings, when available, or the modified Duke criteria. RESULTS: Fifty four subjects were included, 31 (57%) with a diagnosis of NVE. [18F]FDG-PET/CT correctly identified 21/31 (67.7%) subjects, yielding a sensitivity and specificity of 68% (95% CI 49-83%) and 100% (95% CI 85-100%), respectively. The sensitivity and specificity of the modified Duke criteria were 48% and 74%, respectively. Positive and negative predictive values of PET were 100% (95% CI 84-100%) and 70% (95% CI 51-84%), respectively. Modifying the Duke criteria to include [18F]FDG-PET positivity as a major criterion increased sensitivity to 77% without affecting specificity and led to the correct reclassification of 8/18 (44.4%) subjects from Possible IE to Definite IE. CONCLUSION: The addition of a positive [18F]FDG-PET/CT as a major criterion in the modified Duke Criteria improved performance of the criteria for the diagnosis of NVE, particularly in those subjects with Possible IE.
Asunto(s)
Endocarditis , Fluorodesoxiglucosa F18 , Endocarditis/diagnóstico por imagen , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Estudios RetrospectivosRESUMEN
BACKGROUND: Pyrophosphate (PYP) scintigraphy provides high diagnostic accuracy for the detection of transthyretin (ATTR) cardiac amyloidosis (CA). There has recently been emerging interest in using 18F-sodium fluoride (NaF) for this application, yet its sensitivity has never been directly compared to that of PYP, the current molecular gold standard METHODS: Twelve subjects with ATTR-CA and 5 controls referred for PYP-SPECT were prospectively enrolled. 18F-NaF PET/CT scans were performed at 1 and 3 hours. Qualitative and quantitative analyses of the images were performed, and the sensitivity of 18F-NaF PET/CT and PYP-SPECT were compared RESULTS: Visual interpretation of NaF PET/CT yielded a sensitivity of 0.25 (95% CI 0.089 to 0.53) for the detection of ATTR-CA, which is significantly inferior to that of PYP-SPECT/CT (100%, P = .016). Visual interpretation at 3 hours yielded a similar sensitivity of 0.30 (95% CI 0.11 to 0.60, P = 1.00). There were no false-positive NaF PET studies. Mean target-to-background ratio (TBRmean) at 1h did not differ significantly (P = .21) in ATTR-CA subjects (0.83 ± 0.15) compared to controls (0.72 ± 0.15). Receiver operating characteristic (ROC) analysis yielded an area under the curve (AUC) of 0.69 ± 0.16 (95% CI 0.37 to 1.00, P = .23). CONCLUSION: With qualitative and quantitative analyses, sensitivity of NaF PET/CT is significantly inferior to that of PYP-SPECT for the diagnosis of ATTR-CA.
Asunto(s)
Amiloidosis , Fluoruro de Sodio , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/métodos , Sodio , Pirofosfato de Tecnecio Tc 99mRESUMEN
OBJECTIVE: Evaluate the impact of 82-Rubidium positron emission tomography (PET) myocardial perfusion imaging (MPI) availability on patient management presenting at the emergency department (ED) with chest pain (CP). METHODS: This is a single-center retrospective study of clinical databases. Patients presenting with CP with a non-definitive suspicion of acute coronary syndrome (ACS) at the ED between April 2016 and February 2020 were divided into 2 groups based on PET availability. The proportion of invasive coronary angiography (ICA) without significant coronary artery disease (CAD), length of stay (LoS), and additional downstream testing were evaluated. RESULTS: There were 21,242 ED visits for CP without definitive ACS: 5,492 when PET is not available and 15,750 when PET is available. When PET is available, proportion of patients undergoing a MPI study was greater (20.7% vs 17.6%, P<0.0001), proportion of ICA without significant CAD was similar (18.5% vs 21.4%, P=0.24), and median ED LoS was shorter (16.6 vs 18.1 hours, P=0.03). Patients undergoing SPECT MPI had significantly more downstream testing (8.9% vs 6.4%, P=0.003) and a higher rate of coronary angiogram without significant CAD (21.2% vs 14.2%, P=0.09) compared to those who underwent PET MPI. CONCLUSION: Availability of PET MPI was associated with an increased number of MPI referral from the ED, similar rates of ICA without significant CAD, decreased LoS, and fewer downstream testing.
OBJETIVO: Evaluar el impacto de la tomografía por emisión de positrones (PET) con 82-Rubidio y la disponibilidad de imágenes de perfusión miocárdica (MPI) en el manejo de los pacientes que se presentan en el servicio de urgencias (ED) con dolor torácico (CP). MéTODOS: Este es un estudio retrospectivo de bases de datos clínicas de un solo centro. Pacientes que presentaron CP con sospecha no definitiva de síndrome coronario agudo (ACS) en el ED entre abril de 2016 y febrero de 2020, se dividieron en 2 grupos según la disponibilidad de PET. Se evaluó la proporción de angiografía coronaria invasiva (ICA) sin enfermedad arterial coronaria (CAD) significativa, la duración de la estancia (LoS) y las pruebas posteriores adicionales. RESULTADOS: Hubo 21,242 visitas al ED por CP sin ACS definitivo: 5,492 cuando no se dispone de PET y 15.750 cuando se dispone de PET. Cuando se dispone de PET, la proporción de pacientes sometidos a estudio de MPI fue mayor (20.7% vs 17.6%, p=0.03). Los pacientes que se sometieron a SPECT MPI tuvieron significativamente más pruebas posteriores (8.9 % frente a 6.4 %, p = 0.003) y una tasa más alta de angiografía coronaria sin CAD significativa (21.2 % frente a 14.2 %, p = 0.09) en comparación con los que se sometieron a PET MPI. CONCLUSIóN: La disponibilidad de PET MPI se asoció con un mayor número de referencias de MPI desde el ED, tasas similares de ICA sin CAD significativa, disminución de LoS y menos pruebas posteriores.
Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Humanos , Rubidio , Angiografía Coronaria/métodos , Estudios Retrospectivos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/complicaciones , Dolor en el Pecho/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía de Emisión de Positrones/métodos , Radioisótopos de Rubidio , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Imagen de Perfusión Miocárdica/métodosRESUMEN
BACKGROUND: Pulmonary hypertension (PH) complicating idiopathic pulmonary fibrosis (IPF) is associated to worse outcome. There is a great need for a non-invasive diagnostic modality to detect and evaluate the severity of pulmonary vascular disease (PVD). 99mTc-PulmoBind is a novel imaging agent that binds to the adrenomedullin (AM) receptor on the pulmonary microvascular endothelium. SPECT imaging employing the endothelial cell tracer 99mTc-PulmoBind was used to assess PVD associated with lung fibrosis. METHODS: Rats with selective right lung bleomycin-induced fibrosis were compared to control rats. SPECT imaging was performed after three weeks with 99mTc-PulmoBind and 99mTc-macroaggregates of albumin (MAA). PH and right ventricular (RV) function were assessed by echocardiography. Lung perfusion was evaluated by fluorescent microangiography. Lung AM receptor expression was measured by qPCR and by immunohistology. Relevance to human IPF was explored by measuring AM receptor expression in lung biopsies from IPF patients and healthy controls. RESULTS: The bleomycin group developed preferential right lung fibrosis with remodeling and reduced perfusion as assessed with fluorescent microangiography. These rats developed PH with RV hypertrophy and dysfunction. 99mTc-PulmoBind uptake was selectively reduced by 50% in the right lung and associated with reduced AM receptor expression, PH and RV hypertrophy. AM receptor was co-expressed with the endothelial cell protein CD31 in alveolar capillaries, and markedly reduced after bleomycin. Quantitative dynamic analysis of 99mTc-PulmoBind uptake in comparison to 99mTc-MAA revealed that the latter distributed only according to flow, with about 60% increased left lung uptake while left lung uptake of 99mTc-PulmoBind was not affected. Lung from human IPF patients showed important reduction in AM receptor expression closely associated with CD31. CONCLUSIONS: SPECT imaging with 99mTc-PulmoBind detects PVD and its severity in bleomycin-induced lung fibrosis. Reduced AM receptor expression in human IPF supports further clinical development of this imaging approach.
Asunto(s)
Adrenomedulina/análogos & derivados , Bleomicina/toxicidad , Endotelio Vascular/metabolismo , Hipertensión Pulmonar/metabolismo , Fragmentos de Péptidos/metabolismo , Fibrosis Pulmonar/metabolismo , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adrenomedulina/metabolismo , Animales , Antibióticos Antineoplásicos/toxicidad , Endotelio Vascular/diagnóstico por imagen , Endotelio Vascular/efectos de los fármacos , Hipertensión Pulmonar/inducido químicamente , Hipertensión Pulmonar/diagnóstico por imagen , Masculino , Fibrosis Pulmonar/inducido químicamente , Fibrosis Pulmonar/diagnóstico por imagen , Radiofármacos/metabolismo , Ratas , Ratas WistarRESUMEN
BACKGROUND: Conventional nuclear imaging with bone-seeking radiopharmaceuticals has been shown to be a sensitive test for the detection of transthyretin cardiac amyloidosis (ATTR); however, to date, few data exist on the utility of 18F-sodium fluoride (NaF) positron emission tomography (PET) in subjects with cardiac amyloidosis (CA). METHODS: Myocardial perfusion imaging and cardiac 18F-NaF PET/CT of 7 subjects with ATTR, four with light-chain CA (AL), and four controls were retrospectively reviewed. Qualitative interpretation and quantitative analyses with average left ventricular standardized uptake values (SUVmean) and target-to-background ratios (TBRmean) were performed. RESULTS: Average TBRmean was significantly increased in subjects with ATTR (0.98 ± 0.09) compared to AL (0.85 ± 0.08, P = .026) and CTL (0.82 ± 0.07, P = .020), while SUVmean was not (P = .14). Receiver-operator characteristic (ROC) analysis yielded an area under the curve (AUC) of 0.91, with a sensitivity/specificity of 75%/100% for TBRmean using a cutoff value of 0.89 for the diagnosis of ATTR. Qualitative interpretation resulted in a sensitivity/specificity of 57%/100% for ATTR. CONCLUSIONS: While 18F-NaF PET/CT demonstrates good diagnostic accuracy for ATTR, particularly when using quantitative analysis, the low TBRmean values observed in ATTR indicate poor myocardial signal. 18F-NaF PET/CT is not yet ready for clinical use in CA until further comparison studies are performed with 99mTc-DPD/PYP.
Asunto(s)
Amiloidosis/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Radioisótopos de Flúor , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluoruro de Sodio , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Radiofármacos , Estudios RetrospectivosRESUMEN
BACKGROUND: Qualification and interpretation standards are essential for establishing 99mTc-SPECT MPI accuracy vs. alternative modalities. METHODS: Rest-stress 99mTc-SPECT phantom scans were acquired on 35 cameras. LV defects were quantified with summed stress (SSS) and difference scores (SDS) at 2 core labs. SDS ≥ 2 in the right coronary artery (RCA) was the qualifying standard. Twenty rest (R)-stress (S) patient images were acquired on qualified cameras and interpreted by core labs. Global scoring differences > 3 between labs or discordant clinical interpretations underwent review. Scoring, interpretation, image quality, and diagnostic parameter agreement were assessed. RESULTS: Phantom scans: visual scoring confirmed RCA-ischemia on all cameras. Regional SSS, SDS agreement was moderate to very good: ICC-r = 0.57, 0.84. Patient scans: 90% of global SSS, 85% of SDS differences were ≤ 3. Regional SSS, SDS agreement: ICC-r = 0.87, 0.86, and global abnormal (SSS ≥ 4) and ischemic (SDS ≥ 2) interpretation: ICC-r = 0.90 were excellent. Clinical interpretation agreement was 100% following review. Image quality agreement was 70%. Automated metrics also agreed: ischemic total perfusion deficit ICC-r = 0.75, reversible perfusion defect, transient ischemic dilation, and S-R LV ejection fraction ICC-r ≥ 0.90. CONCLUSION: Quantitative scoring and interpretation of scans were highly repeatable with site qualification and clinical interpretation standardization, indicating that dual-core lab interpretation is appropriate to determine 99mTc-SPECT MPI accuracy.
Asunto(s)
Imagen de Perfusión Miocárdica/métodos , Fantasmas de Imagen , Tecnecio , Tomografía Computarizada de Emisión de Fotón Único/normas , Anciano , Anciano de 80 o más Años , Canadá , Femenino , Humanos , Masculino , Persona de Mediana EdadRESUMEN
BACKGROUND: Myocardial perfusion imaging (MPI) with positron emission tomography allows accurate measurements of myocardial blood flow (MBF). Stress MBF thresholds have been proposed to provide diagnostic and prognostic information in different pathology. Most studies relying on dipyridamole use a 5-minute infusion protocol, while current guidelines recommend a 4-minute infusion. The purpose of this study is to compare the effects of different dipyridamole infusion times on stress MBF. METHODS: The charts of 2,207 patients who underwent rubidium-82 MPI were retrospectively reviewed and 147 subjects with low likelihood of significant coronary artery disease (CAD) defined as calcium score = 0, body mass index < 45 kg·m-2, and summed stress score ≤ 3 were included. Of those, 65 were imaged with a 4-minute dipyridamole infusion (0.56 mg·kg-1) protocol and 82 with a 5-minute protocol (0.70 mg·kg-1). RESULTS: Stress MBF (3.23±0.76 vs 3.02±0.71 mL·min-1·g-1, P = 0.09), myocardial flow reserve (2.70±0.67 vs 2.85±0.74, P = 0.20), and coronary vascular resistance index (30±10 vs 31±9 mmHg × g × min·mL-1, P = 0.38) were not significantly different between the two protocols. The 5-minute protocol was associated with higher prevalence of symptoms (92.7% vs 81.5%, P = 0.04) and greater decrease in systolic blood pressure (- 9 vs - 6 mmHg, P = 0.03). CONCLUSIONS: The 4-minute and 5-minute dipyridamole infusion protocols produce comparable myocardial flow response, hemodynamic changes, and symptoms, in subjects with low likelihood of significant obstructive CAD.
Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Dipiridamol/administración & dosificación , Imagen de Perfusión Miocárdica , Tomografía de Emisión de Positrones , Vasodilatadores/administración & dosificación , Adulto , Anciano , Circulación Coronaria/fisiología , Esquema de Medicación , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Radioisótopos de RubidioRESUMEN
BACKGROUND: IQ-SPECT has been shown to significantly reduce acquisition time and administered dose while preserving image quality in myocardial perfusion imaging. Whether IQ-SPECT provides accurate left ventricular ejection fractions (LVEF) with gated blood pool SPECT (GBPS) remains unknown. METHODS: Sixty patients underwent IQ-SPECT GBPS and planar imaging. Among those patients, 11 underwent both cMRI and GBPS. GBPS LVEF, LVEDV, and LVESV were calculated using 2 validated software; QBS (Cedars-Sinai Medical Center, Los Angeles, USA) and MHI (Montreal Heart Institute, Montreal, Canada). LVEF, LVEDV, and LVESV obtained with the different modalities were compared. RESULTS: Average planar LVEF was 48 ± 11% (mean ± SD), average LVEDV was 177 ± 59 mL (range 63 to 342 mL), and average LVESV was 96 ± 46 mL (range 16 to 234 mL). GBPS LVEF and their correlation coefficient with planar LVEF were 40 ± 12% (r = 0.70) and 44 ± 12% (r = 0.83) with QBS and MHI, respectively. Correlation coefficient between cMRI and planar LVEF was 0.65 and were 0.69 and 0.52 between cMRI and GBPS using QBS and MHI, respectively. CONCLUSIONS: LVEF calculated with GBPS using IQ-SPECT correlates with planar measurements. Correlation is best using the MHI method and variation is independent of LVEDV.
Asunto(s)
Angiografía/métodos , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Imagen de Acumulación Sanguínea de Compuerta/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Miocarditis/diagnóstico por imagen , Programas Informáticos , Volumen Sistólico , Disfunción Ventricular Izquierda , Función Ventricular IzquierdaRESUMEN
Previous studies have suggested good adaptation of cardiac transplant (CTx) recipients to exposure to a high altitude. No studies have investigated the cardiopulmonary and biomarker responses to acute hypoxic challenges following CTx. Thirty-six CTx recipients and 17 age-matched healthy controls (HC) were recruited. Sixteen (16) patients (42%) had cardiac allograft vasculopathy (CAV). Cardiopulmonary responses to maximal and submaximal exercise at 21% O2 , 20-minutes hypoxia (11.5% O2 ), and following a 10-minute exposure to 11.5% O2 using 30% of peak power output were completed. Vascular endothelial growth factor (VEGF), interleukin-6 (IL-6), suppression of tumorigenicity 2 (ST2) were measured at baseline and at peak stress. Endothelial peripheral function was assessed using near-infrared spectroscopy. Compared with HC, CTx presented a lesser O2 desaturation both at rest (-19.4 ± 6.8 [CTx] vs -24.2 ± 6.0% O2 [HC], P < 0.05) and following exercise (-23.2 ± 4.9 [CTx] vs -26.2 ± 4.7% O2 [HC], P < 0.05). CTx patients exhibited a significant decrease in peak oxygen uptake. IL-6 and VEGF levels were significantly higher in CTx recipients in basal conditions but did not change in response to acute stress. CTx patients exhibit a favorable ventilatory and overall response to hypoxic stress. These data provide further insights on the good adaptability of CTx to exposure to high altitude.
Asunto(s)
Adaptación Fisiológica , Biomarcadores/análisis , Sistema Cardiovascular/fisiopatología , Ejercicio Físico , Trasplante de Corazón/métodos , Hipoxia/fisiopatología , Pulmón/fisiología , Altitud , Estudios de Casos y Controles , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Consumo de Oxígeno , Estudios ProspectivosRESUMEN
PURPOSE: The adrenomedullin receptor is densely expressed in the pulmonary vascular endothelium. PulmoBind, an adrenomedullin receptor ligand, was developed for molecular diagnosis of pulmonary vascular disease. We evaluated the safety of PulmoBind SPECT imaging and its capacity to detect pulmonary vascular disease associated with pulmonary hypertension (PH) in a human phase II study. METHODS: Thirty patients with pulmonary arterial hypertension (PAH, n = 23) or chronic thromboembolic PH (CTEPH, n = 7) in WHO functional class II (n = 26) or III (n = 4) were compared to 15 healthy controls. Lung SPECT was performed after injection of 15 mCi 99mTc-PulmoBind in supine position. Qualitative and semi-quantitative analyses of lung uptake were performed. Reproducibility of repeated testing was evaluated in controls after 1 month. RESULTS: PulmoBind injection was well tolerated without any serious adverse event. Imaging was markedly abnormal in PH with â¼50% of subjects showing moderate to severe heterogeneity of moderate to severe extent. The abnormalities were unevenly distributed between the right and left lungs as well as within each lung. Segmental defects compatible with pulmonary embolism were present in 7/7 subjects with CTEPH and in 2/23 subjects with PAH. There were no segmental defects in controls. The PulmoBind activity distribution index, a parameter indicative of heterogeneity, was elevated in PH (65% ± 28%) vs. controls (41% ± 13%, p = 0.0003). In the only subject with vasodilator-responsive idiopathic PAH, PulmoBind lung SPECT was completely normal. Repeated testing 1 month later in healthy controls was well tolerated and showed no significant variability of PulmoBind distribution. CONCLUSIONS: In this phase II study, molecular SPECT imaging of the pulmonary vascular endothelium using 99mTc-PulmoBind was safe. PulmoBind showed potential to detect both pulmonary embolism and abnormalities indicative of pulmonary vascular disease in PAH. Phase III studies with this novel tracer and direct comparisons to lung perfusion agents such as labeled macro-aggregates of albumin are needed. CLINICAL TRIAL: ClinicalTrials.gov, NCT02216279.
Asunto(s)
Endotelio Vascular/diagnóstico por imagen , Hipertensión Pulmonar/diagnóstico por imagen , Pulmón/irrigación sanguínea , Imagen Molecular/efectos adversos , Seguridad , Adulto , Estudios de Casos y Controles , Femenino , Humanos , Hipertensión Pulmonar/patología , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Reproducibilidad de los ResultadosRESUMEN
BACKGROUND: Stress-induced dyssynchrony has been shown to be independently correlated with clinical outcomes in patients with dilated cardiomyopathy (DCM) and narrow QRS complexes. However, the extent to which stress levels affect inter- and intraventricular dyssynchrony parameters remains unknown. METHODS: Ten large dogs were submitted to tachycardia-induced DCM by pacing the right ventricular apex for 3-4 weeks to reach a target ejection fraction (EF) of 35% or less. Stress was then induced in DCM dogs by administering intravenous dobutamine up to a maximum of 20 µg·kg-1·min-1. Hemodynamic and ventricular dyssynchrony data were analyzed by left ventricular (LV) pressure measurements and gated blood pool SPECT (GBPS) imaging. In order to assess mechanical dyssynchrony in DCM subjects and compare it with that of 8 normal counterparts, we extracted the following data: count-based indices of LV contraction homogeneity index (CHI), entropy and phase standard deviation, and interventricular dyssynchrony index. RESULTS: A significant LV intraventricular dyssynchrony (CHI: 96.4 ± 1.3% in control vs 78.6% ± 10.9% in DCM subjects) resulted in an intense LV dysfunction in DCM subjects (EF: 49.5% ± 8.4% in control vs 22.6% ± 6.0% in DCM), compared to control subjects. However, interventricular dyssynchrony did not vary significantly between the two groups. Under stress, DCM subjects showed a significant improvement in ventricular functional parameters at each level (EF: 22.6% ± 6.0% at rest vs 48.1% ± 5.8% at maximum stress). All intraventricular dyssynchrony indices showed a significant increase in magnitude of synchrony from baseline to stress levels of greater than or equal to 5 µg·kg-1·min-1 dobutamine. There were individual differences in the magnitude and pattern of change in interventricular dyssynchrony during the various levels of stress. CONCLUSIONS: Based on GBPS analyses, different levels of functional stress, even in close intervals, can have a significant impact on hemodynamic and intraventricular dyssynchrony parameters in a DCM model with narrow QRS complex.
Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/fisiopatología , Prueba de Esfuerzo/métodos , Imagen de Acumulación Sanguínea de Compuerta/métodos , Taquicardia Ventricular/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Animales , Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca/métodos , Cardiomiopatía Dilatada/etiología , Perros , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/fisiopatología , Disfunción Ventricular Izquierda/etiologíaRESUMEN
This phase I study (NCT01539889) evaluated the safety, efficacy, and dosing of PulmoBind for molecular imaging of pulmonary circulation. PulmoBind is a ligand of the adrenomedullin receptor abundantly distributed in lung capillaries. Labeled with 99mTc, it allows single-photon emission computed tomographic (SPECT) imaging of lung perfusion. In preclinical studies, PulmoBind scans enabled detection of lung perfusion defects and quantification of microcirculatory occlusion caused by pulmonary hypertension. Healthy humans ( N = 20) were included into escalating groups of 5 mCi ( n = 5), 10 mCi ( n = 5), or 15 mCi ( n = 10) 99mTc-PulmoBind. SPECT imaging was serially performed, and 99mTc-PulmoBind dosimetric analysis was accomplished. The radiochemical purity of 99mTc-PulmoBind was greater than 95%. There were no safety concerns at the three dosages studied. Imaging revealed predominant and prolonged lung uptake with a mean peak extraction of 58% ± 7%. PulmoBind was well tolerated, with no clinically significant adverse event related to the study drug. The highest dose of 15 mCi provided a favorable dosimetric profile and excellent imaging. The postural lung perfusion gradient was detectable. 99mTc-PulmoBind is safe and provides good quality lung perfusion imaging. The safety/efficacy of this agent can be tested in disorders of pulmonary circulation such as pulmonary arterial hypertension.
RESUMEN
This phase I study (NCT01539889) evaluated the safety, efficacy, and dosing of PulmoBind for molecular imaging of pulmonary circulation. PulmoBind is a ligand of the adrenomedullin receptor abundantly distributed in lung capillaries. Labeled with 99mTc, it allows single-photon emission computed tomographic (SPECT) imaging of lung perfusion. In preclinical studies, PulmoBind scans enabled detection of lung perfusion defects and quantification of microcirculatory occlusion caused by pulmonary hypertension. Healthy humans (N â=â 20) were included into escalating groups of 5 mCi (n â=â 5), 10 mCi (n â=â 5), or 15 mCi (n â=â 10) 99mTc-PulmoBind. SPECT imaging was serially performed, and 99mTc-PulmoBind dosimetric analysis was accomplished. The radiochemical purity of 99mTc-PulmoBind was greater than 95%. There were no safety concerns at the three dosages studied. Imaging revealed predominant and prolonged lung uptake with a mean peak extraction of 58% ± 7%. PulmoBind was well tolerated, with no clinically significant adverse event related to the study drug. The highest dose of 15 mCi provided a favorable dosimetric profile and excellent imaging. The postural lung perfusion gradient was detectable. 99mTc-PulmoBind is safe and provides good quality lung perfusion imaging. The safety/efficacy of this agent can be tested in disorders of pulmonary circulation such as pulmonary arterial hypertension.
Asunto(s)
Endotelio Vascular/patología , Pulmón/patología , Imagen Molecular , Receptores de Adrenomedulina/metabolismo , Adrenomedulina/análogos & derivados , Adrenomedulina/química , Adrenomedulina/metabolismo , Adulto , Anciano , Diástole , Femenino , Humanos , Concentración de Iones de Hidrógeno , Ligandos , Masculino , Microcirculación , Persona de Mediana Edad , Fragmentos de Péptidos/química , Radiometría , Sístole , Tecnecio/química , Adulto JovenRESUMEN
BACKGROUND: Precise identification of left ventricular (LV) systolic mechanical dyssynchrony may be useful in optimizing the response to cardiac resynchronization therapy in heart failure (HF) patients. However, LV dyssynchrony is mostly measured at rest; patients often suffer from the HF symptoms during exercise. OBJECTIVES: Our objective was to examine the impacts of stress on LV synchronism with phase analysis of gated SPECT myocardial perfusion imaging (GMPS) within a normal animal cohort. METHODS: Stress was induced with different levels of dobutamine infusion in six healthy canine subjects. Hemodynamic properties were assessed by LV pressure measurements. Also, LV mechanical synchronism (coordination of LV septal and lateral wall at the time of contraction) was determined by phase analysis of GMPS using commercially available QGS software and in-house MHI4MPI software, with the thickening- and displacement-based method. Synchrony indexes in MHI4MPI included the septal-to-lateral delay and homogeneity index, derived from each of the two methods. Also, bandwidth, SD, and entropy (synchrony indexes) of the QGS software were assessed. RESULTS: LVEF increased from 36.7% ± 8.7% at rest to 53.67% ± 12.34% at 20 µg · kg(-1) · minute(-1) (P < .001). Also, cardiac output increased from 3.67 ± 1.0 L · minute(-1) at rest to 8.4 ± 2.6 L · minute(-1) at 10 µg · kg(-1) · minute(-1) (P < .001). The same trend was observed for dP/dt max which increased from 1,247 ± 382.7 at rest to 5,062 ± 1,800 mm Hg · s(-1) at 10 µg · kg(-1) · minute(-1) (P < .01). Entropy decreased from 55.2% ± 8% at baseline to 43.5% ± 8.5% at 5 and 43.0% ± 3.7% at 10 µg · kg(-1) · minute(-1) dobutamine (P < .01). Thickening homogeneity index showed a difference from 91.7% ± 5.53% at rest to 98.2% ± 0.75% at 20 µg · kg(-1) · minute(-1) (P < .05). CONCLUSIONS: Dobutamine stimulation could amplify the ventricular synchronism, and the thickening-based approach is more accurate than wall displacement for assessment of mechanical dyssynchrony in GMPS.
Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Dobutamina , Ventrículos Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen de Perfusión Miocárdica/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Función Ventricular Izquierda/fisiología , Animales , Perros , Prueba de Esfuerzo/métodos , Ventrículos Cardíacos/efectos de los fármacos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Volumen Sistólico/efectos de los fármacos , Volumen Sistólico/fisiología , Vasodilatadores , Función Ventricular Izquierda/efectos de los fármacosRESUMEN
Lymphatic vessels are essential for preventing the accumulation of harmful components within peripheral tissues, including the artery wall. Various endogenous mechanisms maintain adequate lymphatic function throughout life, with platelets being essential for preserving lymphatic vessel integrity. However, since lymph lacks platelets, their impact on the lymphatic system has long been viewed as restricted to areas where lymphatics intersect with blood vessels. Nevertheless, platelets can also exert long range effects through the release of extracellular vesicles (EVs) upon activation. We observed that platelet EVs (PEVs) are present in lymph, a compartment to which they could transfer regulatory effects of platelets. Here, we report that PEVs in lymph exhibit a distinct signature enabling them to interact with lymphatic endothelial cells (LECs). In vitro experiments show that the internalization of PEVs by LECs maintains their functional integrity. Treatment with PEVs improves lymphatic contraction capacity in atherosclerosis-prone mice. We suggest that boosting lymphatic pumping with exogenous PEVs offers a novel therapeutic approach for chronic inflammatory diseases characterized by defective lymphatics.
Asunto(s)
Plaquetas , Células Endoteliales , Vesículas Extracelulares , Vasos Linfáticos , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/fisiología , Vasos Linfáticos/metabolismo , Vasos Linfáticos/fisiología , Animales , Células Endoteliales/fisiología , Células Endoteliales/metabolismo , Plaquetas/metabolismo , Plaquetas/fisiología , Ratones , Humanos , Ratones Endogámicos C57BL , Masculino , FemeninoRESUMEN
BACKGROUND: We evaluated the accuracy of planar radionuclide angiography and different count-based and space-based electrocardiogram (ECG)-gated blood-pool single-photon emission computed tomography (GBPS) algorithms for assessment of left ventricular end-diastolic volume (LVEDV), end-systolic volume (LVESV), and ejection fraction (LVEF) compared with the gold standard of cardiac magnetic resonance imaging (cMRI). The goal is to assess the accuracy of a recently developed GBPS algorithm. METHODS AND RESULTS: Subjects had planar, GBPS, and cMRI sequentially. Datasets were processed by QBS software (Cedar-Sinai) and by MHI software (Montreal Heart Institute). Space-based approaches were used to compute LVEDV, LVESV, and LVEF. Count-based techniques were also used to assess LVEF. All results were compared to cMRI. Fifty-five patients (85% male; mean age 63 +/- 9 years) completed the study. LVEFs and their correlations to cMRI values were 43 +/- 12% (r = .82), 39 +/- 14% (r = .82), and 39 +/- 13% for MHI(space), QBS(space), and cMRI methodologies, respectively. LVEF by count-based methods also demonstrated good correlation to LVEF provided by cMRI (42 +/- 13%, r = .88 for MHI(count) and 46 +/- 15%, r = .84 for QBS(count)). Strong correlations were obtained for LVEDV (r = .96 for MHI and r = .92 for QBS) and for LVESV (.97 for MHI and r = .94 for QBS). CONCLUSIONS: All Gated blood-pool SPECT algorithms had significant variation in estimating LVEF. Nevertheless our software provides good estimates of LV volumes and LVEF. Such software may, therefore, be applied to assess LV morphology and function.
Asunto(s)
Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca , Imagen por Resonancia Magnética , Volumen Sistólico , Femenino , Imagen de Acumulación Sanguínea de Compuerta , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Ventriculografía con RadionúclidosRESUMEN
PURPOSE: FDG-PET/CT has the potential to play an important role in the diagnosis of sternal wound infections (SWI). The purpose of this study was to analyze the diagnostic accuracy of FDG-PET/CT for SWI in patients following sternotomy. METHODS: We performed a single-center, retrospective analysis of patients who had undergone median sternotomy and FDG-PET/CT imaging. The gold standard consisted of positive bacterial culture and/or the presence of purulent material at surgery. Qualitative patterns of sternal FDG uptake, SUVmax, and associated CT findings were determined, and an imaging scoring system was developed. The diagnostic performances were studied in both the recent (≤ 6 months between sternotomy and imaging) and remote surgery phase (> 6 months). RESULTS: A total of 40 subjects were identified with 11 confirmed SWI cases. Consensus interpretation was associated with a sensitivity of 91% and specificity of 97%. Combination of uptake patterns yielded an AUC of 0.96 while use of SUVmax yielded an AUC of 0.82. CONCLUSIONS: Results suggest that FDG-PET/CT may be useful for the diagnosis of SWI with optimal diagnostic accuracy achieved by identifying specific patterns of uptake. SUVmax can be helpful in assessing subjects with remote surgery, but its use is limited in the context of recent surgery. Further studies are required to confirm these results.
RESUMEN
Circulating adrenomedullin (AM) levels are elevated in several cardiovascular diseases, including pulmonary vascular diseases causing pulmonary hypertension. To date the perfusion agent 99mTc-albumin macroaggregates (MAA) is the only approved radiopharmaceutical used for imaging of pulmonary circulation. Unlike 99mTc-MAA, imaging the AM receptors involves a molecular process dependent on the density of the receptors and the affinity of specific radioligands. The AM receptors are abundantly distributed in lung capillaries and its integrity provides protection in the development of pulmonary vascular diseases. This review summarizes the development and characterization of radioligands for in vivo imaging of AM receptors as an early predictor of the onset of a pulmonary vascular disease.
RESUMEN
BACKGROUND: There is growing interest in developing a practical technique to accurately assess ventricular synchrony. We describe a novel 3-dimensional (3D) gated blood pool single photon emission computed tomography (SPECT) approach, from which a contraction homogeneity index (CHI) is derived and compared with planar phase analyses. METHODS AND RESULTS: Subjects underwent planar and SPECT blood pool acquisition. Planar images were processed for left ventricular ejection fraction computation and phase values. SPECT images were processed by our novel algorithm, with which CHI was computed. Overall, 235 patients (79% male; mean age, 62 +/- 11 years) completed the study. Left ventricular ejection fractions were similar by planar (33.5% +/- 13.5%) and 3D (34.7% +/- 12.7%) methods (r = 0.83, P < .0001). Mean phase angles for planar and tomographic methods were 126.3 degrees +/- 29.6 degrees and 124.4 degrees +/- 28.7 degrees , respectively (r = 0.53, P < .0001). Phase and amplitude signals were incorporated in the CHI, which was non-normally distributed with a median of 73.8% (interquartile range, 58.7%-84.9%). This index minimized the negative impact of dyskinetic wall segments with limited regional motion. The planar heterogeneity index (SDPhi) was 28.2 degrees (interquartile range, 17.5 degrees -46.8 degrees ) and correlated inversely with CHI (r = -0.61, P < .0001). CONCLUSION: The novel 3D dispersion index CHI accounts for both phase delay of a dyssynchronous segment and its magnitude of contraction and is moderately correlated with planar phase analyses. Its potential in cardiac resynchronization therapy remains to be exploited.
Asunto(s)
Imagen de Acumulación Sanguínea de Compuerta/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de TiempoRESUMEN
INTRODUCTION: Adrenomedullin receptors are highly expressed in human alveolar capillaries and provide a molecular target for imaging the integrity of pulmonary microcirculation. In this work, we aimed to develop a NOTA-derivatized adrenomedullin analog (DFH17), radiolabeled with [18F]AlF, for PET imaging of pulmonary microcirculation. METHODS: Highly concentrated [18F](AlF)2+ (15⯵L) was produced from purified fluorine-18 in NaCl 0.9%. Various complexation experiments were carried out at Al-to-NOTA molar ratios ranging from 1:1 to 1:40 to assess optimal radiolabeling conditions before using the peptide. DFH17 peptide (2â¯mM, pHâ¯4) was radiolabeled with [18F](AlF)2+ for 15â¯min at 100⯰C in a total volume of 60⯵L. As part of the radiolabeling process, parameters such as fluorine-18 activity (~37 and 1480â¯MBq), concentration of AlCl3 (0.75, 2, 3, 6 or 10â¯mM) and the effects of hydrophilic organic solvent (aqueous vs ethanol 50%) were studied. The final formulation was tested for purity, identity and stability in saline. Initial in vivo evaluation of [18F]AlF-DFH17 was performed in normal rats by PET/CT. RESULTS: The scaled-up production of [18F]AlF-DFH17 was performed in high radiochemical and chemical purities in an overall radiochemical yield of 22-38% (at end-of-synthesis) within 60â¯min. The final formulation was stable in saline at different radioactive concentrations for 8â¯h. PET evaluation in rats revealed high lung-to-background ratios and no defluorination in vivo up to 1â¯h post-injection. CONCLUSION: The novel radioconjugate [18F]AlF-DFH17 appears to be a promising PET ligand for pulmonary microcirculation imaging.