Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
2.
J Biomed Opt ; 10(1): 11011, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15847577

RESUMEN

The neonatal rabbit brain shows prolonged postnatal development both structurally and physiologically. We use noninvasive near-IR frequency-domain optical spectroscopy (NIRS) and magnetic resonance imaging (MRI) to follow early developmental changes in cerebral oxygenation and anatomy, respectively. Four groups of animals are measured: NIRS in normals, MRI in normals, and both NIRS and MRI with hypoxia-ischemia (HI) (diffusion MRI staging). NIRS and/or MRI are performed from P3 (postnatal day=P) up to P76. NIRS is performed on awake animals with a frequency-domain tissue photometer. Absolute values of oxyhemoglobin concentration ([HbO2]), deoxyhemoglobin concentration ([HbR]), total hemoglobin concentration (HbT), and hemoglobin saturation (StO2) are calculated. The brains of all animals appeared to be maturing as shown in the diffusion tensor MRI. Mean optical coefficients (reduced scattering) remained unchanged in all animals throughout. StO2 increased in all animals (40% at P9 to 65% at P43) and there are no differences between normal, HI controls, and HI brains. The measured increase in StO2 is in agreement with the reported increase in blood flow during the first 2 months of life in rabbits. HbT, which reflects blood volume, peaked at postnatal day P17, as expected since the capillary density increases up to P17 when the microvasculature matures.


Asunto(s)
Animales Recién Nacidos/crecimiento & desarrollo , Isquemia Encefálica/fisiopatología , Encéfalo/crecimiento & desarrollo , Imagen de Difusión por Resonancia Magnética , Hipoxia Encefálica/fisiopatología , Espectroscopía Infrarroja Corta , Animales , Isquemia Encefálica/complicaciones , Circulación Cerebrovascular , Hemoglobinas/metabolismo , Hipoxia Encefálica/complicaciones , Oxihemoglobinas/metabolismo , Conejos
3.
Opt Express ; 6(3): 49-57, 2000 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-19401744

RESUMEN

We have developed an instrument for non-invasive optical imaging of the human brain that produces on-line images with a temporal resolution of 160 ms. The imaged quantities are the temporal changes in cerebral oxy-hemoglobin and deoxy-hemoglobin concentrations. We report real-time videos of the arterial pulsation and motor activation recorded on a 4 x 9 cm 2 area of the cerebral cortex in a healthy human subject. This approach to optical brain imaging is a powerful tool for the investigation of the spatial and temporal features of the optical signals collected on the brain.

4.
J Biomed Opt ; 3(2): 129-36, 1998 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23015049

RESUMEN

Frequency-domain optical mammography has been advocated to improve contrast and thus cancer detectability in breast transillumination. To the best of our knowledge, this report provides the first systematic clinical results of a frequency-domain laser scanning mammograph (FLM). The instrument provides monochromatic light at 690 and 810 nm, whose intensity is modulated at 110.0010 and 110.0008 MHz, respectively. The breast is scanned by stepwise positioning of source and detector, and amplitude and phase for both wavelengths are measured by a photomultiplier tube using heterodyne detection. Images are formed representing amplitude or phase data on linear gray scales. Furthermore, various algorithms carrying on more than one signal (amplitude ratio, phase difference, µa,µs',N) were essayed. Twenty visible cancers out of 25 cancers in the first 59 investigations were analyzed for their quantitative contrast with respect to the whole breast or to defined reference areas. Contrast definitions refer to the signal itself (definition 1), to the signal noise (definition 2), or were based on nonparametric comparison (definition 3). The amplitude signal provides better contrast than the phase signal. Ratio images between red and infrared amplitudes gave variable results; in some cases the tumor contrast was canceled. The algorithms to determine µa and µs' from amplitude and phase data did not significantly improve upon objective contrast. The N algorithm, using the phase signal to flatten the amplitude signal did significantly improve upon contrast according to contrast definitions 1 and 2, however, did not improve upon nonparametric contrast. Thus, with the current instrumentation, the phase signal is helpful to correct for the complex and variable geometry of the breast. However, an independent informational content for tumor differentiation could not be determined. The flat field algorithm did greatly enhance optical contrast in comparison with amplitude or amplitude ratio images. Further evaluation of FLM will have to be based on the N-algorithm images. © 1998 Society of Photo-Optical Instrumentation Engineers.

5.
Med Phys ; 27(4): 801-15, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10798703

RESUMEN

We have noninvasively studied the motor cortex hemodynamics in human subjects under rest and motor stimulation conditions using a multichannel near-infrared tissue spectrometer. Our instrument measures optical maps of the cerebral cortex at two wavelengths (758 and 830 nm), with an acquisition time of 160 ms per map. We obtained optical maps of oxy- and deoxy-hemoglobin concentration changes in terms of amplitudes of folding average, power spectrum and coherence at the stimulation repetition frequency, and the phase synchronization index. Under periodic motor stimulation conditions, we observed coherence and frequency or phase synchronization of the local hemodynamic changes with stimulation. Our main findings are the following: (1) The amplitude of the hemodynamic response to the motor stimulation is comparable to the amplitude of the fluctuations at rest. (2) The spatial patterns of the oxy- and deoxy-hemoglobin responses to the stimulation are different. (3) The hemodynamic response to stimulation shows a spatial localization and a level of phase synchronization with the motor stimulation that depends on the stimulation period.


Asunto(s)
Encéfalo/irrigación sanguínea , Espectrofotometría Infrarroja/métodos , Adulto , Anciano , Algoritmos , Lateralidad Funcional , Hemodinámica , Hemoglobinas/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Oxihemoglobinas/metabolismo , Esfuerzo Físico , Reproducibilidad de los Resultados , Descanso , Espectrofotometría Infrarroja/instrumentación , Factores de Tiempo
6.
Med Phys ; 23(1): 149-57, 1996 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8700026

RESUMEN

We have investigated the problem of edge effects in laser-beam transillumination scanning of the human breast. Edge effects arise from tissue thickness variability along the scanned area, and from lateral photon losses through the sides of the breast. Edge effects can be effectively corrected in frequency-domain measurements by employing a two-step procedure: (1) use of the phase information to calculate an effective tissue thickness for each pixel location; (2) application of the knowledge of tissue thickness to calculate an edge-corrected optical image from the ac signal image. The measurements were conducted with a light mammography apparatus (LIMA) designed for feasibility tests in the clinical environment. Operating in the frequency-domain (110 MHz), this instrument performs a transillumination optical scan at two wavelengths (685 and 825 nm). We applied the proposed two-step procedure to data from breast phantoms and from human breasts. The processed images provide higher contrast and detectability in optical mammography with respect to raw data breast images.


Asunto(s)
Mamografía/métodos , Fenómenos Biofísicos , Biofisica , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Rayos Láser , Mamografía/instrumentación , Mamografía/estadística & datos numéricos , Óptica y Fotónica/instrumentación , Fantasmas de Imagen
7.
Phys Med Biol ; 46(1): 41-62, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11197678

RESUMEN

The frequency-domain multiple-distance (FDMD) method is capable of measuring the absolute absorption and reduced scattering coefficients of optically turbid media. Absolute measurement of absorption at two near-infrared (NIR) wavelengths makes possible the quantitation of tissue haemoglobin concentration and tissue haemoglobin oxygen-saturation (StO2). However, errors are introduced by the uncertainties of background absorption and the dissimilarities between real tissues and the simplified mathematical model on which these measurements are based. An FDMD-based tissue instrument has been used for the monitoring of tissue haemoglobin concentration and oxygenation in the brain of newborn piglets during periods of hypoxia and hyperoxia. These tissue haemoglobin saturation values were compared with arterial saturation (SaO2) and venous saturation (SvO2) measured by blood gas analyses. A linear correlation was observed between StO2 and the average of SaO2 and SvO2. However, StO2 is not equal to any fixed weighted average of SaO2 and SvO2 unless we introduce an effective background tissue absorption. The magnitude of the background absorption was about 0.08 cm(-1) at 758 nm and 0.06 cm(-1) at 830 nm, and it was nearly consistent between piglets. The origin of this 'effective' background absorption may be real, an artefact caused by the application of a simplified model to a complex sample, or a combination of factors.


Asunto(s)
Encéfalo/metabolismo , Hemoglobinas/análisis , Hipoxia/metabolismo , Estrés Oxidativo , Espectroscopía Infrarroja Corta/instrumentación , Espectroscopía Infrarroja Corta/métodos , Animales , Modelos Estadísticos , Oxígeno/análisis , Oxígeno/metabolismo , Porcinos , Factores de Tiempo , Agua/metabolismo
8.
Phys Med Biol ; 44(6): 1543-63, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10498522

RESUMEN

We have used continuous-wave (CW) and frequency-domain spectroscopy to investigate the optical properties of the newborn piglet brain in vivo and non-invasively. Three anaesthetized, intubated, ventilated and instrumented newborn piglets were placed into a stereotaxic instrument for optimal experimental stability, reproducible probe-to-scalp optical contact and 3D adjustment of the optical probe. By measuring the absolute values of the brain absorption and reduced scattering coefficients at two wavelengths (758 and 830 nm), frequency-domain spectroscopy provided absolute readings (in contrast to the relative readings of CW spectroscopy) of cerebral haemoglobin concentration and saturation during experimentally induced perturbations in cerebral haemodynamics and oxygenation. Such perturbations included a modulation of the inspired oxygen concentration, transient brain asphyxia, carotid artery occlusion and terminal brain asphyxia. The baseline cerebral haemoglobin saturation and concentration, measured with frequency-domain spectroscopy, were about 60% and 42 microM respectively. The cerebral saturation values ranged from a minimum of 17% (during transient brain asphyxia) to a maximum of 80% (during recovery from transient brain asphyxia). To analyse the CW optical data, we have (a) derived a mathematical relationship between the cerebral optical properties and the differential pathlength factor and (b) introduced a method based on the spatial dependence of the detected intensity (dc slope method). The analysis of the cerebral optical signals associated with the arterial pulse and with respiration demonstrates that motion artefacts can significantly affect the intensity recorded from a single optode pair. Motion artefacts can be strongly reduced by combining data from multiple optodes to provide relative readings in the dc slope method. We also report significant biphasic changes (initial decrease and successive increase) in the reduced scattering coefficient measured in the brain after the piglet had been sacrificed.


Asunto(s)
Animales Recién Nacidos , Encéfalo/diagnóstico por imagen , Espectroscopía Infrarroja Corta/instrumentación , Espectroscopía Infrarroja Corta/métodos , Animales , Asfixia/diagnóstico , Estenosis Carotídea/diagnóstico , Hemoglobinas/análisis , Modelos Teóricos , Radiografía , Reproducibilidad de los Resultados , Porcinos , Factores de Tiempo
9.
Med Biol Eng Comput ; 33(2): 228-30, 1995 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-7643667

RESUMEN

Tissue oxygen saturation quantification was obtained using a frequency-domain multi-source method based on two wavelength light-emitting diodes. Brain saturation was 60.3 +/- 1.1% (n = 12). Brachioradial muscle saturation declined during forearm ischaemia and maximal voluntary contraction from 73.7 +/- 1.8 and 74.7 +/- 1.8% at rest to 44.2 +/- 3.3 and 61.4 +/- 2.9%, respectively.


Asunto(s)
Encéfalo/metabolismo , Músculo Esquelético/metabolismo , Consumo de Oxígeno , Adulto , Femenino , Antebrazo/irrigación sanguínea , Humanos , Isquemia/metabolismo , Masculino , Espectrofotometría Infrarroja/métodos
10.
Clin Hemorheol Microcirc ; 21(3-4): 389-93, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10711775

RESUMEN

Near-infrared spectroscopy (NIRS) is a noninvasive technique to measure the tissue oxygenation in real time. This optical method has many advantages over the invasive analysis currently used for clinical tests. Among the possible applications of near-infrared oxymetry, we report three protocols (exercise, venous occlusion and tilting table) in conjunction with NIRS, and discuss their applicability in the diagnosis of peripheral vascular disease (PVD).


Asunto(s)
Oximetría/métodos , Enfermedades Vasculares Periféricas/diagnóstico , Espectroscopía Infrarroja Corta/métodos , Humanos , Oximetría/instrumentación , Oxígeno , Enfermedades Vasculares Periféricas/metabolismo , Espectroscopía Infrarroja Corta/instrumentación
11.
Biomed Opt Express ; 1(2): 553-565, 2010 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-21258489

RESUMEN

Cerebral blood flow (CBF) during stepped hypercapnia was measured simultaneously in the rat brain using near-infrared diffuse correlation spectroscopy (DCS) and arterial spin labeling MRI (ASL). DCS and ASL CBF values agree very well, with high correlation (R=0.86, p< 10(-9)), even when physiological instability perturbed the vascular response. A partial volume effect was evident in the smaller magnitude of the optical CBF response compared to the MRI values (averaged over the cortical area), primarily due to the inclusion of white matter in the optically sampled volume. The 8.2 and 11.7 mm mid-separation channels of the multi-distance optical probe had the lowest partial volume impact, reflecting ~75 % of the MR signal change. Using a multiplicative correction factor, the ASL CBF could be predicted with no more than 10% relative error, affording an opportunity for real-time relative cerebral metabolism monitoring in conjunction with MR measurement of cerebral blood volume using super paramagnetic contrast agents.

13.
Neurocrit Care ; 11(2): 288-95, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19649749

RESUMEN

INTRODUCTION: Near-infrared spectroscopy (NIRS) is a non-invasive, real-time bedside modality sensitive to changes in cerebral perfusion and oxygenation and is highly sensitive to physiological oscillations at different frequencies. However, the clinical feasibility of NIRS remains limited, partly due to concerns regarding NIRS signal quantification, which relies on mostly arbitrary assumptions on hemoglobin concentrations and tissue layers. In this pilot study comparing stroke patients to healthy controls, we explored the utility of the interhemispheric correlation coefficient (IHCC) during physiological oscillations in detecting asymmetry in hemispheric microvascular hemodynamics. METHODS: Using bi-hemispheric continuous-wave NIRS, 12 patients with hemispheric strokes and 9 controls were measured prospectively. NIRS signal was band-pass filtered to isolate cardiac (0.7-3 Hz) and respiratory (0.15-0.7 Hz) oscillations. IHCCs were calculated in both oscillation frequency bands. Using Fisher's Z-transform for non-Gaussian distributions, the IHCC during cardiac and respiratory oscillations were compared between both groups. RESULTS: Nine patients and nine controls had data of sufficient quality to be included in the analysis. The IHCCs during cardiac and respiratory oscillations were significantly different between patients versus controls (cardiac 0.79 +/- 0.18 vs. 0.94 +/- 0.07, P = 0.025; respiratory 0.24 +/- 0.28 vs. 0.59 +/- 0.3; P = 0.016). CONCLUSIONS: Computing the IHCC during physiological cardiac and respiratory oscillations may be a new NIRS analysis technique to quantify asymmetric microvascular hemodynamics in stroke patients in the neurocritical care unit. It allows each subject to serve as their own control obviating the need for arbitrary assumptions on absolute hemoglobin concentration. Future clinical applications may include rapid identification of patients with ischemic brain injury in the pre-hospital setting. This promising new analysis technique warrants further validation.


Asunto(s)
Accidente Cerebrovascular/fisiopatología , Anciano , Anciano de 80 o más Años , Encéfalo/fisiología , Encéfalo/fisiopatología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Oscilometría , Proyectos Piloto , Respiración , Espectroscopía Infrarroja Corta/instrumentación , Espectroscopía Infrarroja Corta/métodos
14.
Neuroimage ; 29(2): 368-82, 2006 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-16303317

RESUMEN

In this study, we have preformed simultaneous near-infrared spectroscopy (NIRS) along with BOLD (blood oxygen level dependent) and ASL (arterial spin labeling)-based fMRI during an event-related motor activity in human subjects in order to compare the temporal dynamics of the hemodynamic responses recorded in each method. These measurements have allowed us to examine the validity of the biophysical models underlying each modality and, as a result, gain greater insight into the hemodynamic responses to neuronal activation. Although prior studies have examined the relationships between these two methodologies through similar experiments, they have produced conflicting results in the literature for a variety of reasons. Here, by employing a short-duration, event-related motor task, we have been able to emphasize the subtle temporal differences between the hemodynamic parameters with a high contrast-to-noise ratio. As a result of this improved experimental design, we are able to report that the fMRI measured BOLD response is more correlated with the NIRS measure of deoxy-hemoglobin (R = 0.98; P < 10(-20)) than with oxy-hemoglobin (R = 0.71), or total hemoglobin (R = 0.53). This result was predicted from the theoretical grounds of the BOLD response and is in agreement with several previous works [Toronov, V.A.W., Choi, J.H., Wolf, M., Michalos, A., Gratton, E., Hueber, D., 2001. "Investigation of human brain hemodynamics by simultaneous near-infrared spectroscopy and functional magnetic resonance imaging." Med. Phys. 28 (4) 521-527.; MacIntosh, B.J., Klassen, L.M., Menon, R.S., 2003. "Transient hemodynamics during a breath hold challenge in a two part functional imaging study with simultaneous near-infrared spectroscopy in adult humans". NeuroImage 20 1246-1252.; Toronov, V.A.W., Walker, S., Gupta, R., Choi, J.H., Gratton, E., Hueber, D., Webb, A., 2003. "The roles of changes in deoxyhemoglobin concentration and regional cerebral blood volume in the fMRI BOLD signal" Neuroimage 19 (4) 1521-1531]. These data have also allowed us to examine more detailed measurement models of the fMRI signal and comment on the roles of the oxygen saturation and blood volume contributions to the BOLD response. In addition, we found high correlation between the NIRS measured total hemoglobin and ASL measured cerebral blood flow (R = 0.91; P < 10(-10)) and oxy-hemoglobin with flow (R = 0.83; P < 10(-05)) as predicted by the biophysical models. Finally, we note a significant amount of cross-modality, correlated, inter-subject variability in amplitude change and time-to-peak of the hemodynamic response. The observed co-variance in these parameters between subjects is in agreement with hemodynamic models and provides further support that fMRI and NIRS have similar vascular sensitivity.


Asunto(s)
Arterias Cerebrales/fisiología , Circulación Cerebrovascular/fisiología , Espectroscopía de Resonancia por Spin del Electrón , Imagen por Resonancia Magnética , Movimiento/fisiología , Oxígeno/sangre , Espectroscopía Infrarroja Corta , Adulto , Biomarcadores , Química Encefálica/fisiología , Arterias Cerebrales/anatomía & histología , Femenino , Dedos/fisiología , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Vitamina E/metabolismo , Vitaminas/metabolismo
15.
Neuroimage ; 25(3): 701-7, 2005 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-15808971

RESUMEN

Increased neural activity in brain tissue is accompanied by an array of supporting physiological processes, including increases in blood flow and the rates at which glucose and oxygen are consumed. These responses lead to secondary effects such as alterations in blood oxygenation and blood volume, and are ultimately the primary determinants of the amplitude and temporal signature of the blood oxygenation level-dependent (BOLD) signal used prevalently to map brain function. We have performed experiments using a combination of optical and MRI-based imaging methods to develop a more comprehensive picture of the physiological events accompanying activation of primary motor cortex during a finger apposition task. Temporal profiles for changes in tissue hemoglobin concentrations were qualitatively similar to those observed for MRI-based flow and oxygenation signals. Quantitative analysis of these signals revealed peak changes of +16 +/- 2% for HbO, -13 +/- 2% for HbR, +8 +/- 3% for total Hb, +83 +/- 9% for cerebral blood flow, and +1.4 +/- 0.1% for the BOLD MRI signal. A mass balance model was used to estimate the change in rate of oxidative metabolism implied by the optical and flow measurements, leading to a computed value of +47 +/- 5%. It should be noted that the optical and MRI observations may in general reflect changes over different volumes of tissue. The ratio of fractional changes in oxidative metabolism to fractional change in blood flow was found to be 0.56 +/- 0.08, in general agreement with previous studies of flow-metabolism coupling.


Asunto(s)
Nivel de Alerta/fisiología , Atención/fisiología , Volumen Sanguíneo/fisiología , Encéfalo/irrigación sanguínea , Procesamiento de Imagen Asistido por Computador/instrumentación , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Corteza Motora/fisiología , Oxígeno/sangre , Tomografía Óptica/instrumentación , Mapeo Encefálico , Dominancia Cerebral/fisiología , Metabolismo Energético/fisiología , Diseño de Equipo , Humanos , Aumento de la Imagen , Actividad Motora/fisiología , Consumo de Oxígeno/fisiología , Tiempo de Reacción/fisiología , Sensibilidad y Especificidad , Pulgar/inervación
16.
Appl Opt ; 36(1): 156-63, 1997 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-18250657

RESUMEN

The Green's function for the diffusion equation is widely used to describe photon transport in turbid media. We have performed aseries of spectroscopy experiments on a number of uniform turbid media with different optical properties (absorption coefficient in the range 0.03-0.14 cm(-1), reduced scattering coefficient in the range 5-22 cm(-1)). Our experiments have been conducted in the frequency domain, where the measured parameters are the dc intensity (I(dc)), ac amplitude (I(ac)), and phase (?) of the light intensity wave. In an infinite medium, the Green's function predicts a linear dependence of ln(rI(dc)) and ? on the source-detector separation r. Our measurements show that the intercepts of these straight lines predicted by the Green's function do not agree with the experimental results. To reproduce the experimental results, we have introduced an effective photon source whose spatial extent and source strength depend on the optical properties of the medium. This effective source term has no effect on the slopes of the straight lines predicted by the Green'sfunction at large values of r.

17.
Opt Lett ; 24(12): 829-31, 1999 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-18073868

RESUMEN

We present a frequency-domain optical method for real-time noninvasive measurement of absolute tissue and arterial saturation. This method is based on quantitative measurement of the tissue absorption spectrum (for tissue saturation) and of the amplitude of the arterial-pulsation-induced absorption oscillations (for arterial saturation) at eight wavelengths in the range 633-841 nm. We report results obtained from readings taken from the forehead of a healthy volunteer, showing baseline saturation values of 74.7+/-0.2% (tissue) and 96.9+/-0.5% (arterial). These values dropped to minimum values of 71.6+/-0.2% and 90.0+/-0.2% , respectively, after 1 min of reduced inspired oxygen concentration [10% (by volume) O(2) from a baseline value of 21% O(2) ].

18.
Philos Trans R Soc Lond B Biol Sci ; 352(1354): 727-35, 1997 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-9232861

RESUMEN

Non-invasive techniques for the study of human brain function based on changes of the haemoglobin content or on changes of haemoglobin saturation have recently been proposed. Among the new methods, near-infrared transmission measurements may have significant advantages and complement well-established methods such as functional magnetic resonance imaging and positron emission tomography. Near-infrared measurements can be very fast, comparable in speed to electrophysiological measurements, bur are better localized. We will present the demonstration of measurements of millisecond signals due to brain activity in humans following stimulation of the visual cortex. However, major unresolved questions remain about the origin of the signals observed. Optical measurements on exposed cortex in animals show that both the absorption and the scattering coefficient are affected by neural activity. Model calculations show that the signals we detected may originate from rapid changes of the scattering coefficient in a region about 1 to 2 cm below the scalp. We discuss our measurement protocol, which is based on a frequency-domain instrument, and the algorithm to separate the absorption from the scattering contribution in the overall response. Our method produces excellent separation between scattering and absorption in relatively homogeneous masses such as large muscles. The extrapolation of our measurement protocol to a complex structure such as the human head is critically evaluated.


Asunto(s)
Encéfalo/metabolismo , Hemoglobinas/metabolismo , Músculos/metabolismo , Neuronas/metabolismo , Fantasmas de Imagen , Animales , Encéfalo/irrigación sanguínea , Hemoglobinas/análisis , Humanos , Modelos Teóricos , Músculos/irrigación sanguínea , Oxihemoglobinas/análisis , Oxihemoglobinas/metabolismo , Cráneo , Espectrofotometría Infrarroja/instrumentación , Espectrofotometría Infrarroja/métodos
19.
Opt Lett ; 19(24): 2062-4, 1994 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-19855740

RESUMEN

Tissue glucose levels affect the refractive index of the extracellular fluid. The difference in refractive index between the extracellular fluid and the cellular components plays a role in determining the reduced scattering coefficient (micro(s)') of tissue. Hence a physical correlation may exist between the reduced scattering coefficient and glucose concentration. We have designed and constructed a frequency-domain near-infrared tissue spectrometer capable of measuring the reduced scattering coefficient of tissue with enough precision to detect changes in glucose levels in the physiological and pathological range.

20.
Opt Lett ; 29(13): 1506-8, 2004 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-15259728

RESUMEN

We compare two geometries of sources and detectors for optimizing the diffuse optical imaging resolution of brain activation in humans. Because of limitations in the instruments' dynamic range, most diffuse optical brain activation images have used only nonoverlapping measurements. We demonstrate theoretically and with a human experiment that a simple geometry of sources and detectors can provide overlapping measurements within the limitation of instrumentation dynamic range and produce an image resolution and localization accuracy that is twofold better.


Asunto(s)
Encéfalo/fisiología , Circulación Cerebrovascular , Aumento de la Imagen/métodos , Tomografía Óptica , Adulto , Circulación Cerebrovascular/fisiología , Simulación por Computador , Hemodinámica , Humanos , Modelos Teóricos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda