Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Arch Orthop Trauma Surg ; 142(12): 3599-3603, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33993360

RESUMEN

INTRODUCTION: It was the goal of this study to determine if the Orthopaedic Trauma Association Open Fracture Classification (OTA-OFC) correlates with complication rates and to determine if it can be used as a predictive tool in the treatment of open tibial shaft fractures. MATERIALS AND METHODS: Retrospective review from two high-volume level 1 trauma centers of open tibial shaft fractures over a 5 year period. Variables of interest included OTA-OFC, type of wound closure, 90-day wound complication, unplanned re-operation, non-union, and amputation. RESULTS: 501 consecutive open tibial shaft fractures. 57.3% (n = 287) were closed primarily; local soft tissue advancement/rotational flap was used in 9.6% (n = 48); free soft tissue transfer used in 22.8% (n = 114); 8.6% (n = 43) required amputation. Of those followed for 90 days (n = 419), 45 (9.0%) had a wound complication, of which 40 (8%) required an unplanned reoperation. 40 (8.0%) patients went on to a documented non-union. All OTA-OFC classification groups significantly correlated with type of definitive closure (r = 0.18-0.81, p < 0.05) with OTA-OFC skin showing the strongest correlation (r = 0.81). OTA-OFC bone loss weakly correlated with wound complication (r = 0.12, p = 0.02) and no OTA-OFC classification correlated with the need for an unplanned secondary procedure. OTA-OFC skin, muscle and arterial all weakly correlated with non-union (r = 0.18-0.25, p < 0.05). OTA-OFC muscle was predictive of non-union (OR = OR = 2.2, 95% CI = 1.2-4.1) and amputation (OR 9.3, 95% CI = 3.7-23.7). OTA-OFC arterial was also predictive of amputation (OR 4.8, 95% CI = 2.5-9.3). CONCLUSIONS: The OTA-OFC correlates variably with the type of definitive closure, the development of a 90-day wound complication, and the occurrence of a non-union. Importantly, OTA-OFC muscle classification is predictive of non-union while both OTA-OFC muscle and arterial were predictive of amputation.


Asunto(s)
Fracturas Abiertas , Ortopedia , Fracturas de la Tibia , Humanos , Fracturas Abiertas/cirugía , Fracturas Abiertas/complicaciones , Estudios Retrospectivos , Tibia , Pronóstico , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/complicaciones , Resultado del Tratamiento , Curación de Fractura
2.
Arch Orthop Trauma Surg ; 140(1): 25-31, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31134373

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the effect of ankle plantarflexion and the axial location of measurement on quantitative syndesmosis assessment. METHODS: Twelve fresh-frozen cadaveric specimens were secured in three positions of ankle plantarflexion (0°, 15°, and 30°) using an ankle-spanning external fixator and underwent CT scans at each position. Syndesmotic measurements were obtained on axial images using three previously described methods (six measurements) at the level of the tibial plafond and 1 cm proximal to the plafond. Method 1 evaluated the distance between the most anterior and posterior aspects of the fibula and tibia. Method 2 measured medial-lateral diastasis of the anterior and posterior aspects of the fibula, and fibular anterior-posterior translation. Method 3 evaluated axial rotation of the fibula. All measurements were performed by two independent observers. Inter-rater reliability of each measurement was evaluated using intra-class coefficients. Repeated measures analysis of variance (RM-ANOVA) was performed to evaluate within-specimen differences in measurements obtained at varying ankle positions. RESULTS: The anterior incisura component of method 1 demonstrated poor-to-moderate inter-rater reliability across all ankle positions and at both measurement locations. Inter-rater reliability was highest for method 2, especially when measured 1 cm proximal to the plafond. Method 3 demonstrated moderate reliability 1 cm proximal to the plafond. After correcting for multiple comparisons, RM-ANOVA and pairwise analysis revealed that none of the measurements changed significantly with varying ankle position. CONCLUSION: The inter-rater reliability of the most common method of syndesmotic evaluation (method 1) was found to be lower than in previous studies. The most reliable syndesmotic evaluation can be made by measuring diastasis and anteroposterior translation 1 cm proximal to the plafond (method 2). Ankle position from 0° to 30° of plantarflexion did not change the measurements obtained. LEVEL OF EVIDENCE: IV.


Asunto(s)
Tobillo/diagnóstico por imagen , Postura/fisiología , Tomografía Computarizada por Rayos X , Peroné/diagnóstico por imagen , Humanos , Reproducibilidad de los Resultados , Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas
3.
J Foot Ankle Surg ; 58(4): 669-673, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30962109

RESUMEN

Recent literature has reported an uncategorized hyperplantarflexion variant ankle fracture characterized by a posteromedial fragment separate from the posterior or medial malleolar fragments. The current study sought to determine whether the outcomes for surgically treated hyperplantarflexion variant fractures are similar to the more common supination external rotation (SER) IV fractures. A prospective registry of operatively treated ankle fractures was queried to create 2 age- and gender-matched cohorts: hyperplantarflexion variant and SER IV fractures. Each cohort had 23 patients (18 females), and matched pairs were within 2 years of age at the date of surgery. Patient demographics, comorbidities, and Foot and Ankle Outcomes Scores at minimum 12 months after the index surgery were compared. The cohorts were similar with respect to body mass index, the length of the clinical follow-up, medical comorbidities, dislocation rate, and postoperative articular incongruity (p > .05). Patient-reported outcomes demonstrated no statistically or clinically significant differences within any domain and were as follows: symptoms (70.8 versus 77.8, p = .11), pain (80.7 versus 85.0, p = .33), activities of daily living (83.7 versus 89.2, p = .23), sports (67.4 versus 73.4, p = .33), and quality of life (57.3 versus 63.9, p = .24) for the hyperplantarflexion and SER IV groups, respectively. No significant differences were found in the rang`e of motion for dorsiflexion (17.7° versus 18.1°, p = .52) or for plantarflexion (48.6° versus 47.1°, p = .71). Patients treated surgically for hyperplantarflexion variant ankle fractures have similar 1-year clinical outcomes when compared with the more common SER IV fracture patterns, provided that the injury is correctly identified preoperatively and treated appropriately.


Asunto(s)
Fracturas de Tobillo/cirugía , Fractura-Luxación/cirugía , Fijación Interna de Fracturas , Adolescente , Adulto , Anciano , Fracturas de Tobillo/clasificación , Fracturas de Tobillo/diagnóstico por imagen , Estudios de Cohortes , Femenino , Fractura-Luxación/diagnóstico por imagen , Fijación Interna de Fracturas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Complicaciones Posoperatorias , Radiografía , Rotación , Supinación , Resultado del Tratamiento , Adulto Joven
4.
Arch Orthop Trauma Surg ; 138(12): 1653-1657, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30094560

RESUMEN

INTRODUCTION: Osteoporosis and decreased bone density are known to increase fracture incidence and severity. Although much is known regarding the effects of bone density on fracture risk and the treatment options for prevention of fragility fractures, whether bone quality alters clinical outcomes after fracture fixation is unknown. The purpose of this study was to determine whether bone quality correlates with clinical outcomes after fracture fixation. MATERIALS AND METHODS: A prospective database of all operatively treated ankle fractures by a single surgeon from 2003 to 2013 was used to identify patients. All patients included in the study had preoperative computed tomography (CT) imaging of the injured ankle and postoperative CT imaging of the contralateral ankle. Hounsfield unit (HU) measurement values were determined by placing an elliptical region of interest confined to the cancellous metaphyseal region of the distal tibia and fibula. The primary and secondary clinical outcomes included Foot and Ankle Outcome Scores (FAOS) and ankle range of motion (ROM). Included patients had at least 12 months of clinical outcome data. RESULTS: Sixty-four patients met the inclusion criteria. Comparison of HU values from the injured and contralateral side demonstrated almost perfect agreement (ICC(2,1) = 0.938), suggesting that HU values can be accurately measured in the setting of a fracture. Increased HU values of the injured distal tibia and fibula significantly correlated with improved outcomes in four of five FAOS domains, including pain, activities of daily living, sports, and quality of life (beta = 0.285-0.344; P ≤ 0.05 for all). Range of motion outcomes did not significantly correlate with HU values. CONCLUSIONS: Our results suggest that decreased bone quality, as measured using preoperative CT, significantly correlates with inferior short-term clinical outcomes. These results have significant implications for integrating bone quality into treatment algorithms for fracture patients.


Asunto(s)
Fracturas de Tobillo/cirugía , Articulación del Tobillo/fisiopatología , Densidad Ósea/fisiología , Fijación Interna de Fracturas/métodos , Osteoporosis/complicaciones , Absorciometría de Fotón/métodos , Actividades Cotidianas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/cirugía , Femenino , Peroné/diagnóstico por imagen , Fijación Interna de Fracturas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Rango del Movimiento Articular/fisiología , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento , Adulto Joven
5.
Arch Orthop Trauma Surg ; 137(6): 755-760, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28391428

RESUMEN

INTRODUCTION: The operative management of tibial plateau fractures in elderly patients has historically led to inconsistent results, and these clinical outcomes were thought to be associated with poor bone quality often in elderly patients. The goal of this study was to investigate the relationship between bone density and subjective clinical outcome scores after open reduction and internal fixation of tibial plateau fractures. MATERIALS AND METHODS: This is a retrospective cohort study from a single-surgeon conducted at an Academic, Level 1 Trauma Center. A preoperative computed tomography (CT) scan was obtained for all patients. Bone density of the distal femur was quantified with Hounsfield units (HU) as measured on axial CT scans. Inter-rater reliability of HU measurements was assessed using interclass correlation coefficients. Regression models controlling for age were used to identify relationships between bone density (HU) and the following variables: articular subsidence and 1-year subjective clinical outcomes scores [Knee Outcome Survey Activities of Daily Living Scale (KOS-ADLS), and Short-Form-36 (SF-36) physical and mental component scores (PCS, MCS)]. RESULTS: Sixty-one patients with a mean age of 59.3 years (range 27-85 years) and a minimum of 12 months of clinical follow-up were included in the study. The majority of the fractures (32 of 61) were classified as Schatzker II tibial plateau fractures, and there were 13 Schatzker V fractures, 11 Schatzker VI fractures, 2 Schatzker IV fractures and 1 Schatzker 1 fracture. HU measurements demonstrated an almost perfect inter-observer reliability (ICC = 0.97). Age was negatively correlated with HU measurements (r = -0.51, p < 0.001), and using a geriatric cut-off of 65 years of age, the geriatric group had a lower mean HU compared to the non-geriatric group (78.2 versus 114.8, p = 0.018). There was no significant relationship between bone quality, as assessed by distal femoral HU, and any subjective clinical outcome score. CONCLUSIONS: Inferior bone mineral density alone does not appear to affect clinical outcomes 1 year postoperatively when bone grafting is used to restore osseous voids. Poor bone quality should not be used as an indication for non-operative management of tibial plateau fractures.


Asunto(s)
Densidad Ósea , Fijación Interna de Fracturas/métodos , Curación de Fractura , Reducción Abierta/métodos , Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Actividades Cotidianas , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Reproducibilidad de los Resultados , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico , Factores de Tiempo , Tomografía Computarizada por Rayos X
6.
J Pediatr Orthop ; 36(1): e6-9, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25955169

RESUMEN

BACKGROUND: Low-dose biplanar radiography (EOS) is an appealing imaging modality for use in children given its low radiation and ease of use. The goal of this study was to determine the accuracy and reliability of EOS compared with CT scanogram for measurement of leg length and to assess interrater and intrarater reliability of measured interbead distances for EOS and CT scanogram after insertion of tantalum beads into lamb femurs. METHODS: Tantalum beads (0.8 mm) were inserted into the cortex on both the medial and lateral sides of 10 skeletally immature lamb femurs. CT scanogram and EOS imaging were obtained. Measurements of total length and distance between bead pairs were recorded on anteroposterior and lateral views by 2 orthopaedic surgeons on 2 separate occasions. Pearson correlations were performed for statistical comparisons. RESULTS: EOS measurements showed near-perfect correlation to those of CT scanogram (r>0.96, P<0.001). Intrarater reliability was excellent for all measurements with EOS (r>0.98, P<0.001) and CT scanogram (r>0.99, P<0.001) as was interrater reliability for EOS (r>0.98, P<0.001) and CT scanogram (r>0.99, P<0.001). CONCLUSIONS: EOS is comparable with CT scanogram in the assessment of limb length and the distance between 2 radiopaque markers. Reliability was excellent for all measurements. The combination of EOS imaging and tantalum bead implantation may be an effective way to evaluate physeal growth following procedures such as epiphysiodesis and physeal bar resection. LEVEL OF EVIDENCE: Level II­diagnostic


Asunto(s)
Alargamiento Óseo/métodos , Fémur/diagnóstico por imagen , Diferencia de Longitud de las Piernas/diagnóstico por imagen , Cirugía Asistida por Computador/métodos , Tantalio , Tomografía Computarizada por Rayos X/métodos , Animales , Modelos Animales de Enfermedad , Fémur/cirugía , Isótopos , Diferencia de Longitud de las Piernas/cirugía , Dosis de Radiación , Reproducibilidad de los Resultados , Ovinos
7.
Arch Orthop Trauma Surg ; 136(3): 339-44, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26660079

RESUMEN

INTRODUCTION: Hypovitaminosis D is common in patients undergoing orthopaedic trauma surgery. While previous studies have shown that vitamin D levels correlate with functional outcome after hip fracture surgery, the significance of vitamin D levels on outcomes after surgery in other orthopaedic trauma patients is unknown. The purpose of this study was to determine if vitamin D levels correlated with outcomes in ankle fracture patients. MATERIALS AND METHODS: We reviewed a prospective registry of patients who underwent operative treatment for ankle fractures from 2003 to 2012. Preoperative serum 25-hydroxyvitamin D (25[OH]D) levels were measured, and the primary and secondary outcomes included foot and ankle outcome scores (FAOS) and ankle range of motion. Data were also collected on patient comorbidities, articular malreductions, and wound complications. Included patients had at least 12 months of clinical outcome data. RESULTS: Ninety-eight patients operatively treated for ankle fractures met our inclusion criteria. Of these 98 patients, 36 (37%) were deficient in vitamin D (<20 ng/ml) and 31 (32%) had vitamin D insufficiency (<30 ng/ml, ≥20 mg/ml). Patients with vitamin D deficiency were similar with regard to age, gender, and comorbidities compared to patients with vitamin D levels ≥20. Univariate analysis revealed that patients with vitamin D deficiency had significantly worse FAOS with regard to symptoms (P = 0.017) and quality of life (P = 0.040) domains than patients with vitamin D levels ≥20. Multivariate regression analysis suggested that vitamin D deficiency was a factor in inferior FAOS with regard to symptoms, activities of daily living, and quality of life. CONCLUSIONS: In our group of patients with operative treated ankle fractures, preoperative vitamin D deficiency correlated with inferior clinical outcomes at a minimum of 1 year follow-up. Our study suggests that deficient vitamin D levels may result in worse outcomes in orthopaedic trauma patients recovering from fracture fixation.


Asunto(s)
Fracturas de Tobillo/cirugía , Fijación Interna de Fracturas/métodos , Curación de Fractura , Periodo Perioperatorio , Deficiencia de Vitamina D/sangre , Vitamina D/análogos & derivados , Actividades Cotidianas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Fracturas de Tobillo/epidemiología , Articulación del Tobillo/fisiopatología , Comorbilidad , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Calidad de Vida , Rango del Movimiento Articular/fisiología , Estudios Retrospectivos , Resultado del Tratamiento , Vitamina D/sangre , Deficiencia de Vitamina D/epidemiología , Adulto Joven
8.
J Shoulder Elbow Surg ; 24(6): 889-96, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25483905

RESUMEN

BACKGROUND: Osteosynthesis of proximal humeral fractures is challenging in geriatric patients. The purpose of this investigation was to compare postoperative clinical outcomes between cohorts of geriatric (aged ≥65 years) and non-geriatric proximal humeral fracture patients treated via locked plating with endosteal fibular strut allograft augmentation. METHODS: From March 2007 to January 2013, 71 adult patients with 2-, 3-, and 4-part proximal humeral fractures according to the Neer classification underwent osteosynthesis with locked plating and fibular allograft augmentation and had at least 12 months of clinical follow-up. All patients followed the same postoperative rehabilitation protocol. We compared the following between geriatric and non-geriatric patients: Disabilities of the Arm, Shoulder and Hand scores; University of California, Los Angeles shoulder ratings; Constant-Murley scores; and range of motion; as well as injury characteristics and radiographic outcomes. RESULTS: Geriatric patients comprised 48% of the study cohort (34 of 71 patients). The mean age of the geriatric and non-geriatric cohorts was 74 years and 53 years, respectively. Geriatric patients showed significantly reduced forward flexion (147° vs 159°, P = .04) when compared with non-geriatric patients. There were no significant differences in functional scores, radiographic outcomes, or complication rates between the 2 cohorts, although in 1 geriatric patient, osteonecrosis developed and screw penetration through the collapsed head was present 3 years after surgery. CONCLUSIONS: Osteosynthesis of proximal humeral fractures via locked plating with fibular strut allograft augmentation results in similar clinical outcomes between geriatric and non-geriatric patients. We believe that enhanced stability provided by this fixation construct allows early intensive postoperative therapy and results in excellent outcomes despite patient age.


Asunto(s)
Peroné/trasplante , Fijación Interna de Fracturas/métodos , Fracturas del Hombro/fisiopatología , Fracturas del Hombro/cirugía , Articulación del Hombro/fisiopatología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Aloinjertos , Placas Óseas , Tornillos Óseos/efectos adversos , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Rango del Movimiento Articular , Fracturas del Hombro/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen , Resultado del Tratamiento
9.
Arch Orthop Trauma Surg ; 135(11): 1491-6, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26264713

RESUMEN

INTRODUCTION: Tibial plateau fractures are common injuries often treated with open reduction and internal fixation. We have noted improved patient satisfaction following implant removal for these patients. The purpose of this study was to assess the effect of removal of surgical implants after union on patient reported outcomes. MATERIALS AND METHODS: All patients at our Level 1 Trauma Center undergoing open reduction an internal fixation by the senior surgeon are offered enrollment into a prospective registry and have clinical outcomes recorded at follow-up [Knee Outcomes Survey (KOS), Lower Extremity Functional Scale (LEFS), Short Form-36 Physical and Mental Component Summary (SF-36 PCS, SF-36 MCS), and Visual analog pain scale (VAS)]. Routinely, removal of surgical implants is offered after fracture union resulting in two cohorts: those who had undergone elective removal of surgical implants and those who had not. Outcome scores were compared before and after implant removal as well as between the two study populations at final follow-up. RESULTS: Seventy-five patients were identified as having 12 month outcome scores: 36 (48%) had retained implants; 39 (52%) had implants removed. KOS and LEFS outcomes improved significantly after implant removal (p < 0.05). Clinical outcomes (KOS, SF-36 PCS) were also significantly better in patients who had implants removed compared to those that did not at final follow-up (p < 0.05). There was no statistical difference seen in VAS pain scores. CONCLUSIONS: The results of this study indicate that patients who have elective removal of their surgical implants after open reduction and internal fixation of a tibial plateau fracture have improved clinical outcomes after removal and also demonstrate significantly better outcomes than those who have retained implants at final follow-up. Patients who are unhappy with their clinical result should be counseled that removal of the implant may improve function, but may not improve pain.


Asunto(s)
Remoción de Dispositivos , Fijación Interna de Fracturas/métodos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Fracturas de la Tibia/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
10.
J Foot Ankle Surg ; 54(4): 531-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25189335

RESUMEN

Stress ankle radiographs are routinely performed to determine deep deltoid ligament integrity in supination external rotation (SER) ankle fractures. However, variability is present in the published data regarding what medial clear space (MCS) value constitutes a positive result. The purposes of the present study were to evaluate the diagnostic accuracy of different MCS cutoff values and determine whether this clinical test could accurately discriminate between patients with and without a deep deltoid ligament disruption. MCS measurements were recorded for stress ankle injury radiographs in an SER ankle fracture cohort. Preoperative ankle magnetic resonance imaging studies, obtained for all patients, were then read independently by 2 musculoskeletal attending radiologists to determine deep deltoid ligament integrity. The MCS measurements were compared with the magnetic resonance imaging diagnosis using receiver operating characteristic analyses to determine the sensitivity, specificity, and optimal data-driven cutoff values. SER II-III patients demonstrated a mean stress MCS distance of 4.3 ± 0.98 mm compared with 5.8 ± 1.76 mm in the SER IV cohort (p < .001). An analysis of differing MCS positive cutoff thresholds revealed that a stress MCS of 5.0 mm maximized the combined sensitivity and specificity of the external rotation test: 65.8% sensitive and 76.5% specific. Using the receiver operating characteristic curve analysis of the MCS measurement, the calculated area under the curve was 0.77, indicating inadequate discriminative ability for diagnosing SER pattern fractures with or without a deep deltoid ligament tear. Judicious use of additional diagnostic testing in patients with a stress MCS result between 4.0 mm and 5.5 mm is warranted.


Asunto(s)
Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/patología , Ligamentos Articulares/lesiones , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Ligamentos Articulares/diagnóstico por imagen , Ligamentos Articulares/patología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Radiografía , Reproducibilidad de los Resultados , Rotación , Sensibilidad y Especificidad , Supinación , Adulto Joven
11.
Arch Orthop Trauma Surg ; 134(12): 1661-6, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25337963

RESUMEN

INTRODUCTION: Posterior malleolus and other articular ankle injuries are known to concomitantly occur with tibial shaft fractures, especially spiral fractures of the distal one-third diaphysis. Due to our heightened awareness of this combined injury, our department instituted a new preoperative ankle imaging protocol for all distal one-third spiral tibia shaft fractures. The purpose of this study was to evaluate the effectiveness of an imaging protocol involving radiographs, CT and magnetic resonance imaging (MRI) in a distal one-third spiral tibia fracture cohort. MATERIALS AND METHODS: All operatively treated patients with a spiral distal one-third tibial shaft fracture from February 2012 to March 2013 underwent a standardized ankle imaging protocol. Patients had preoperative orthogonal ankle radiographs as well as a CT scan of the tibia that included the ankle. All ankle imaging was scrutinized for evidence of an ankle injury. If no ankle fracture was identified, patients would then undergo an ankle MRI. RESULTS: Twenty-five patients met the inclusion and exclusion criteria for this study. Concomitant osseous ankle injuries were identified by radiograph and CT in 56 % (14/25) of cases. The remaining 44 % (11/25) of patients had no evidence of a combined injury by radiograph or CT and therefore underwent an MRI. Of the MRI cohort, 64 % (7/11) were found to have an occult ankle fracture. The overall incidence of a combined injury using our protocol was 84 % (21/25). Identification of an occult injury led to a change in management for all of these patients. CONCLUSIONS: Concomitant ipsilateral ankle and distal one-third spiral tibial shaft fractures are more common than previously reported. Utilizing a new imaging protocol, we found that the incidence of this combined injury was 84 %. Recognition of the ankle fracture component in this tibial shaft cohort can be important as it may alter the surgical plan and postoperative management.


Asunto(s)
Fracturas de Tobillo/complicaciones , Traumatismo Múltiple/diagnóstico , Traumatismo Múltiple/cirugía , Fracturas de la Tibia/complicaciones , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/cirugía , Articulación del Tobillo/diagnóstico por imagen , Protocolos Clínicos , Diagnóstico por Imagen , Femenino , Humanos , Ligamentos Articulares/lesiones , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Huesos Tarsianos/diagnóstico por imagen , Tibia/diagnóstico por imagen , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
12.
Injury ; 55(6): 111574, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38669892

RESUMEN

INTRODUCTION: Multiplanar mesh plating of patella fractures has become more popular in recent years. It was the goal of this study to compare the biomechanical stability of cannulated screw with anterior tension band to multiplanar mesh plating for fixation of transverse patella fractures in cadaver specimens. MATERIALS AND METHODS: Eight matched pairs of fresh frozen cadaveric knees were obtained and soft tissues dissected leaving the extensor mechanism, joint capsule, and retinaculum intact. Transverse fractures were created at the mid-portion of the patella. For each pair, one specimen was repaired using cannulated screws with anterior tension band, and the second was repaired using multiplanar mesh plating. Each specimen underwent cyclic extension loading with loads increasing by 1.1 kg after every 50 cycles. Interfragmentary displacement was measured at the end of each interval at both 5° and 45° of knee flexion angle, with fixation failure defined by >2 mm displacement. RESULTS: The specimens fixed with multiplanar mesh plating survived more cycles and higher loads than the specimens fixed with cannulated screws with anterior tension band (p = 0.011 comparing survival plots). After 150 cycles of extension loading, 3 of 8 of the specimens fixed with screws/tension band had failed, whereas none of the mesh plated specimens had failed. After 400 cycles, 7 of 8 of the screws/tension band had failed, whereas half of the mesh plated specimens had failed. CONCLUSIONS: While a more technically challenging and expensive technique, mesh plating for patella fractures appears to offer greater durability than traditional cannulated screw with tension banding.


Asunto(s)
Placas Óseas , Tornillos Óseos , Cadáver , Fijación Interna de Fracturas , Fracturas Óseas , Rótula , Humanos , Rótula/cirugía , Rótula/lesiones , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Fracturas Óseas/fisiopatología , Mallas Quirúrgicas , Masculino , Femenino , Anciano , Ensayo de Materiales , Persona de Mediana Edad , Rango del Movimiento Articular
13.
OTA Int ; 6(3): e275, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37342096

RESUMEN

Purpose: To evaluate the use of computed tomography (CT) imaging as a diagnostic tool for elbow arthrotomies using a standardized cadaveric arthrotomy model. Method: Nineteen intact fresh frozen cadaver elbows were CT scanned using 2 mm cuts with sagittal and coronal reformats in the plane of the joint and used as controls. An elbow arthrotomy at the posterocentral arthroscopic portal site was performed in all specimens using a 4.5 millimeter trocar. After arthrotomy, all elbows underwent a second CT scan followed by a standard saline load test (SLT). Images were randomized and reviewed by 2 blinded, independent reviewers. Bimodal scoring was performed for each specimen with regard to the presence of an arthrotomy indicated by presence of air in the joint. Regarding the SLT, saline exiting the arthrotomy wound was considered a positive test. Results: CT scans were found to have 100% sensitivity and 86% specificity for diagnosing elbow arthrotomies. Interrater reliability calculated with Cohen kappa statistic was near perfect at r = 0.89. The SLT had a sensitivity of 79% when 20 mL was injected. A total of 25 mL of saline was required to be injected for a sensitivity greater than 95%. Conclusion: This study demonstrates that CT scan is a reliable and less technically demanding method of diagnosis arthrotomies with high interrater reliability and high sensitivity and with results comparable with SLT. This technique may be useful in centers where trained providers are not readily available to perform SLT. Clinical study is required to validate our results. Level of Evidence: Level II.

14.
J Pediatr Orthop ; 32(3): 282-9, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22411335

RESUMEN

BACKGROUND: Persistent or recurrent hip dysplasia and/or loss of reduction can complicate the treatment of developmental dysplasia of the hip (DDH) in walking children. In this study, we identify predictors for secondary procedures after open reduction of the hip in walking children with DDH. METHODS: We performed a retrospective study of walking children with idiopathic DDH treated with open reduction of the hip and followed up for >5 years. Perioperative factors were analyzed to investigate predictors of reoperation. Factors associated with the need for secondary procedures were identified. Acetabular remodeling was analyzed with a graphical plot of serial (0, 6 and 12 mo, and yearly) mean acetabular index and SD. RESULTS: There were 49 open reductions of the hip in 42 patients (34 female, 8 male) at a mean age of 31.3 months (range, 15.3 to 92.6 mo), with a mean follow-up of 9.7 years (5 to 16.9 y). Twelve (24%) patients had open reduction only, 15 (31%) had concurrent pelvic osteotomy, 4 (8%) had femoral osteotomy, and 18 (37%) had both femoral and pelvic osteotomy. Four (8%) patients required repeat open reduction at a mean of 5.1 months (range, 4 to 7.5 mo) after index surgery. Twenty-four (49%) patients had at least 1 secondary surgery for dysplasia at a mean of 3.2 years after index surgery. Six of the 24 (25%) had 2 and 2/24 (8.3%) had 3 additional operations. Of the 27 patients who did not have concurrent femoral osteotomy at index surgery, 19/27 (73%) required a secondary procedure; this significantly predicted the need for reoperation (P<0.001). Only 5/22 patients with femoral osteotomy at index surgery required a secondary procedure. Maximum acetabular remodeling was observed in the first 4 years after primary reduction, and the mean acetabular index remodeled from 43.9 to 20.3 degrees during this period. CONCLUSIONS: Forty-nine percent of the patients in this cohort required secondary procedures to treat hip dysplasia. Open reduction without concurrent femoral osteotomy strongly predicted the need for a secondary procedure. Maximum acetabular remodeling was observed in the first 4 years after open reduction. LEVEL OF EVIDENCE: Retrospective case series, level IV.


Asunto(s)
Acetábulo/metabolismo , Luxación Congénita de la Cadera/cirugía , Procedimientos Ortopédicos/métodos , Osteotomía/métodos , Remodelación Ósea , Niño , Preescolar , Femenino , Fémur/cirugía , Estudios de Seguimiento , Luxación Congénita de la Cadera/fisiopatología , Humanos , Lactante , Masculino , Huesos Pélvicos/cirugía , Recurrencia , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Factores de Tiempo , Caminata
15.
J Orthop Trauma ; 36(3): e111-e115, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34387566

RESUMEN

OBJECTIVES: To evaluate the perceived utility and associated charges of the anteroposterior (AP) radiograph during rotational ankle fracture postoperative follow-up. DESIGN: Survey study with charge analysis using published data at 50 orthopaedic hospitals in the United States. SETTING: Not Applicable. PARTICIPANTS: Orthopaedic Trauma Association Members with an active email address who were invited and interested in answering a survey. RESULTS: Ninety-four percent of respondents stated that they did routinely obtain an AP radiograph during rotational ankle fracture follow-up. However, 57% thought that the AP view should be eliminated from standard follow-up and only 51% found this view useful after initial treatment. CHARGE ANALYSIS: The mean difference between a 2-view and 3-view ankle radiograph series was $102.00. Using this value and the assumption that each patient with a rotational ankle fracture gets 3 follow-up radiographs, there is the potential for a charge reduction of $306 per patient. Assuming over 134,000 rotational ankle fractures, a charge reduction of 41 million US dollars (USD) per year is possible if the AP image is routinely removed. Actual savings are likely to be less based on agreed on payer rates. Although less easy to quantify, there is also a potential reduction of radiation exposure, radiologists' interpretation time, and data storage. CONCLUSIONS: Routine AP radiographs should potentially be eliminated from routine postoperative ankle x-ray protocols based on this survey of experienced orthopaedic surgeons. If this specific radiograph is ordered on a case-by-case basis, then significant savings may occur.


Asunto(s)
Fracturas de Tobillo , Ortopedia , Tobillo , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/cirugía , Articulación del Tobillo , Humanos , Encuestas y Cuestionarios
16.
Injury ; 53(10): 3102-3108, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36030094

RESUMEN

INTRODUCTION: Little data exists regarding the effects of vaporized nicotine on healing. Our goal was to compare vaporized nicotine, combusted nicotine and control with respect to bone healing in a rat femur fracture model. MATERIALS AND METHODS: Forty-five male Sprague Dawley rats were divided into three equal cohorts. Rats were exposed to two cigarettes daily, an equivalent dose of vaporized nicotine, or control, six days a week. Exposures occurred for 4 weeks prior to iatrogenic femur fracture and intramedullary repair. Four additional weeks of exposure occurred prior to sacrifice. Radiographic, biomechanical and histologic analysis was conducted. RESULTS: No significant difference between the three groups was identified for total mineralized bone volume (p = 0.14), total volume of mature bone (p = 0.12) or immature bone (p = 0.15). Importantly, less total mineralized bone volume and immature bone volume was seen in the vaporized nicotine group compared to combusted tobacco, but results were not significant. Biomechanical testing revealed no significant difference in group torsional stiffness (p = 0.92) or maximum torque (p = 0.31) between the three groups. On histologic analysis, chi-square testing showed no significant difference in any category. CONCLUSIONS: This exploratory study compared combusted nicotine, vaporized nicotine and a control on rat femur fractures. While no statistically significant differences were identified, there were trends showing less total mineralized bone volume and immature bone volume in the vaporized nicotine group compared to the other groups. Additional study is warranted based on our findings.


Asunto(s)
Fumar Cigarrillos , Fracturas del Fémur , Animales , Fenómenos Biomecánicos , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/tratamiento farmacológico , Fracturas del Fémur/cirugía , Fémur/cirugía , Curación de Fractura , Masculino , Nicotina/farmacología , Ratas , Ratas Sprague-Dawley , Nicotiana
17.
J Pediatr Orthop ; 31(1): 11-6, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21150726

RESUMEN

BACKGROUND: The treatment of femoral shaft fractures in heavier children has been studied extensively, however, no study has directly compared elastic nail (TEN) and rigid locking nails (RLN) in this population. Our goal was to compare TEN with RLN in length-stable diaphyseal femur fractures in heavier children and adolescents (47 to 85 kg) using weight-matched cohorts. METHODS: We retrospectively reviewed records for length-stable diaphyseal femoral fractures treated with TEN or RLN over 8 years at our Level 1 Pediatric Trauma Center. Perioperative and follow-up data, including total charges for care, were recorded and radiographic images were reviewed. These data were used to create 2 cohorts having each patient in the TEN cohort matched to within 2 kg of the corresponding patient in the RLN cohort. RESULTS: Fifteen patients from each cohort could be weight matched (TEN, 60.8 kg vs. RLN, 60.4 kg). The RNL cohort was older (15.4 vs. 13.5 y; P = 0.005). Time in operating room and estimated blood loss were greater in the RLN cohort: 158 versus 220 minutes (P = 0.003) and 42 versus 182 ml (P = 0.003), respectively. All patients had a full range of motion at the latest follow-up. Complications were observed in 6 of 15 TEN and 10 of 15 RNL (P = 0.14). Implant-related problems were more common in RLN patients, but this was not statistically significant (3 of 15 vs. 9 of 15; P = 0.06). In the TEN cohort, malunion and leg length discrepancy (> 2 cm) each occurred in a single patient (20 degrees varus, 2.3 cm shortening, respectively) compared with 0 of 15 in RLN (P = 0.48). Treatment with TEN resulted in a total charge of $742 more than RLN (P = 0.75). CONCLUSIONS: In our weight-matched comparison, the use of TEN resulted in decreased time in operating room, estimated blood loss, and implant-related problems. Malunion and leg length discrepancy remain of concern when heavier patients are treated by TEN, but were not significantly increased relative to RNL in this study.


Asunto(s)
Peso Corporal , Clavos Ortopédicos , Fracturas del Fémur/cirugía , Fijación Intramedular de Fracturas/instrumentación , Adolescente , Pérdida de Sangre Quirúrgica , Estudios de Cohortes , Femenino , Fracturas del Fémur/diagnóstico por imagen , Estudios de Seguimiento , Fijación Intramedular de Fracturas/métodos , Fracturas Mal Unidas , Humanos , Diferencia de Longitud de las Piernas/etiología , Masculino , Complicaciones Posoperatorias/etiología , Radiografía , Rango del Movimiento Articular , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
18.
Injury ; 52(11): 3340-3343, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34509285

RESUMEN

OBJECTIVES: There is increasing interest regarding the risks and benefits of intrawound antibiotics applied directly to surgical wounds for the prevention of infection following orthopaedic trauma surgery. The purpose of this study was to investigate the economic justifiability of vancomycin and tobramycin powders for infection prophylaxis in orthopaedic trauma surgery. METHODS: The cost of vancomycin and tobramycin powders, infection rates and costs of treating surgical site infections were obtained from our institution's records and existing literature. A break-even analysis was then performed using vancomycin powder only, tobramycin powder only and combined vancomycin and tobramycin powders to determine the respective absolute risk reduction (ARR) in infection rate needed to make the prophylactic application of each therapy type break-even. RESULTS: At our institutional pricing of $20.64 and $75.80 for 1g vancomycin and 1.2g tobramycin, respectively, use of each individually would be economically justified if it reduced an average infection rate of 4.3% by an ARR of 0.02% and 0.07%, respectively. Used in combination for $90.66, the ARR was 0.09%. Varying cost of treating infection from $5,000-$200,000 while maintaining cost of antibiotic powder at $90.66 demonstrated a range in ARR from 1.93% to 0.05%, respectively. At the same cost of $90.66 but varying infection rate from 1% to 25% did not affect ARR, which was constant at 0.09%. CONCLUSIONS: Considering the cost of vancomycin and tobramycin powder at our institution, the application of these powders, whether independently or in combination, appear to be economically justifiable for infection prevention in orthopaedic trauma surgery.


Asunto(s)
Ortopedia , Vancomicina , Antibacterianos/uso terapéutico , Profilaxis Antibiótica , Humanos , Polvos , Infección de la Herida Quirúrgica/tratamiento farmacológico , Infección de la Herida Quirúrgica/prevención & control , Tobramicina
19.
J Orthop Trauma ; 35(6): e184-e188, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33079834

RESUMEN

OBJECTIVES: To correlate domains of the Orthopaedic Trauma Association Open Fracture Classification (OTA-OFC) in open upper extremity injuries with type of definitive soft-tissue closure, complication rates, and unanticipated return to the operating room for complication. DESIGN: Retrospective review of prospectively collected data. SETTING: Level I trauma center. PATIENTS: Two hundred thirty-four consecutive open upper extremity fractures. INTERVENTION: Operative management of open upper extremity fractures. MAIN OUTCOME MEASUREMENTS: Type of definitive closure, 90-day wound complication, and wound complication necessitating return to the operating room. RESULTS: Two hundred eighty injuries were identified, and 234 had sufficient data for analysis. Eighty-four percent (196/234) of open wounds were closed primarily, 7% (16/234) required a skin graft, and 4% (9/234) required rotational or free flap. Thirteen percent (22/166) of those followed for 90 days had a wound complication, and 50% of those with complication required a return to the OR. All OTA-OFC classifications statistically significantly correlated with type of closure (P < 0.001), with skin having a high correlation (r = 0.79), muscle (r = 0.49) and contamination (r = 0.47) moderate correlations, and arterial (r = 0.32) and bone loss (r = 0.33) low correlations. OTA-OFC muscle classification was predictive of 90-day wound complication (OR 0.31, 95% confidence interval 0.07-0.21). OTA-OFC domains correlated variably with return to the OR. CONCLUSION: OTA-OFC clinically correlates with definitive wound management and 90-day wound complication in open upper extremity fractures. OTA-OFC skin classification has a high correlation with the type of definitive wound closure. OTA-OFC muscle was the only domain that correlated with 90-day wound complication and was predictive of 90-day wound complication. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Traumatismos del Brazo , Fracturas Abiertas , Ortopedia , Fracturas Abiertas/cirugía , Humanos , Estudios Retrospectivos , Extremidad Superior/cirugía
20.
Am J Sports Med ; 49(9): 2522-2527, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34097540

RESUMEN

BACKGROUND: The use of cannabis is common among athletes and the US population at large. Cannabinoids are currently being evaluated as alternatives to opioid medications for chronic pain management. However, the effects of recreational and/or medical use of delta-9-tetrahydrocannabinol (THC) and cannabidiol (CBD) on musculoskeletal injury and healing remain largely unknown. HYPOTHESIS/PURPOSE: The purpose of this study was to evaluate the biomechanical effects of CBD and THC on tendon-to-tendon healing in a rat Achilles tendon repair model. The hypothesis was that rats administered CBD would demonstrate decreased tensile load to failure of surgically repaired Achilles tendons compared with the THC and control groups. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 33 Sprague Dawley rats underwent Achilles tendon surgical transection and repair and were randomized to receive subcutaneous injection of THC, CBD, or vehicle once daily starting on the day of surgery and for 5 total days. After sacrifice, biomechanical tensile load-displacement testing was performed to determine Achilles tendon load to failure and stiffness. Data were analyzed by 1-way analysis of variance. RESULTS: The THC group demonstrated the highest median load to failure, 18.7 N (95% CI, 15.3-19.2 N); the CBD group had the second highest at 16.9 N (95% CI, 15.1-19.8 N), and the control group had the lowest at 14.4 N (95% CI, 12.1-18.3 N). Stiffness was highest in the THC group at 4.1 N/mm (95% CI, 2.7-5.1 N/mm) compared with 3.6 N/mm (95% CI, 2.9-4.1 N/mm) for the CBD group and 3.6 N/mm (95% CI, 2.8-4.3 N/mm) for the control group. No statistically significant differences for strength and stiffness were observed between the groups. CONCLUSION: In this pilot study using an animal tendon-to-tendon repair model, neither THC nor CBD resulted in altered biomechanical characteristics compared to control. CLINICAL RELEVANCE: Cannabinoids do not appear to adversely affect Achilles tendon healing.


Asunto(s)
Tendón Calcáneo , Cannabidiol , Cannabis , Animales , Ratas , Tendón Calcáneo/cirugía , Cannabidiol/farmacología , Dronabinol/farmacología , Proyectos Piloto , Ratas Sprague-Dawley
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda