Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Cardiol Young ; 33(11): 2390-2392, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37203793

RESUMEN

Ventriculoarterial connection is one of the important points of the segmental approach to congenital cardiac malformations. Double outlet of both ventricles is a rare form where both great arterial roots override the interventricular septum. In this article, we aimed to draw attention to this very rare form of ventriculoarterial connection by presenting an infant case diagnosed using echocardiography, CT angiography, and 3-dimensional modelling.


Asunto(s)
Cardiopatías Congénitas , Tabique Interventricular , Lactante , Humanos , Cardiopatías Congénitas/diagnóstico , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/anomalías , Ecocardiografía/métodos , Arterias
2.
Cureus ; 15(10): e46504, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37808606

RESUMEN

INTRODUCTION: With the development of transcatheter interventional techniques and the introduction of next-generation duct occluder devices, transcatheter closure has become the first treatment option for patent ductus arteriosus (PDA) in pediatric patients. In this study, we compared the effectiveness and safety of different devices for transcatheter PDA closure in pediatric patients, focusing on long-term outcomes. METHODS: A total of 235 patients aged 0-18 years who underwent transcatheter PDA closure at a tertiary care center between January 2005 and February 2020 were included. The medical records of the cases were retrospectively evaluated. RESULTS: The median age of the patients was 2.3 years (range: 3.5 months to 17 years), with a mean weight of 12.8 kg (range: 5.7-43.2 kg). The mean PDA diameter at its narrowest point was 2.9 mm (range: 2.2-5.1 mm). Ductal anatomy was as follows: Type A in 98 (41.7%) patients, Type E in 36 (15.6%) patients, Type C in 32 (13.5%) patients, Type F in 27 (11.4%) patients, Type D in 23 (9.7%) patients, and Type B in 19 (8.1%) patients. Arterial access was used in 138 (57.1%) patients, venous + arterial access in 58 (24.6%) patients, and venous access only in 39 (16.5%) patients. Closure was performed with Amplatzer Duct Occluder (ADO; AGA Medical Corp., Golden Valley, MN, USA) II in 151 (64.2%) cases, ADO I in 43 (18.2%) cases, and coils in 41 (17.4%) cases. The mean fluoroscopy time and mean procedural time were 10.3 ± 4.2 minutes and 41 ± 7.2 minutes, respectively. The mean radiation dose was 1364 ± 497 cGy/min. The early closure rate after the procedure was 92%, while residual shunting on the first day post-procedure was observed in 1.8% of cases, decreasing to 0.1% at the one-month follow-up. The overall procedural success rate for all cases was 96.0%. The mean follow-up duration was 9.7 years (range: 2.9-13.8 years). CONCLUSION: For percutaneous PDA closure, ADO I devices are preferred for larger defects, whereas ADO II devices are prioritized for small- to medium-sized defects instead of coils.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda