Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Exp Eye Res ; 202: 108347, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33275919

RESUMEN

Ectatic corneal disease (ECD) comprises a group of disorders characterized by progressive thinning and subsequent bulging of the corneal structure. Different phenotypes have been recognized, including keratoglobus, pellucid marginal degeneration (PMD), and keratoconus (KC). Keratoconus has been widely investigated throughout the years, but the advent of laser refractive surgery boosted an immediate need for more knowledge and research about ectatic diseases. This article discusses nomenclature of ectatic disease, etiology and pathogenesis, along with treatment options, with special focus ok KC and forme fruste keratoconus.


Asunto(s)
Córnea/patología , Enfermedades de la Córnea/patología , Córnea/fisiopatología , Enfermedades de la Córnea/fisiopatología , Topografía de la Córnea , Elasticidad , Humanos
2.
J Cataract Refract Surg ; 49(2): 190-194, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36201664

RESUMEN

PURPOSE: To test the ability of the corneal epithelial pattern standard deviation (PSD) to distinguish between normal and cases with corneal ectatic condition. SETTING: Instituto de Olhos Renato Ambrósio, Rio de Janeiro, Brazil. DESIGN: Cross-sectional retrospective study. METHODS: Patients were stratified into 4 groups based on clinical data and corneal tomography. Groups 1 and 2 comprised 1 eye randomly selected from 105 patients with normal corneas (N) and 86 patients with bilateral keratoconus (KC). Groups 3 and 4, respectively, comprised 11 ectatic eyes with no surgical treatment for KC (very asymmetric ectasia [VAE]-E) from patients whose fellow eyes (61) presented with normal topographic patterns (VAE-NT). Corneas were scanned using an OCT system (RT Vue) and Scheimpflug corneal tomography (Pentacam) and also had biomechanical assessment through the Corvis ST. Corneal epithelial thickness maps were analyzed, and the PSD value was calculated. The area under the receiver operating characteristic curve analysis was used to evaluate the diagnostic accuracy of the indices. RESULTS: A total of 105 normal eyes, 86 keratoconic eyes, and 11 ectatic eyes whose fellow eyes (61) presented normal topographic patterns were evaluated. Epithelial PSD was significantly different across the 4 groups ( P < .0001). The pairwise comparison revealed that the normal group presented significantly lower values than both ectasia groups (KC and VAE-E, P < .0001) and the VAE-NT group ( P = .0008). There was no statistical significant difference between KC and VAE-E ( P = .4284), while they were significantly higher than the VAE-NT group ( P < .0001 and P = .0004). CONCLUSIONS: Epithelial PSD can be used to detect abnormal epithelial thickness patterns. Corneal epithelial thickness changes could be detected accurately in patients with KC, even in the form fruste of the disease.


Asunto(s)
Queratocono , Humanos , Estudios Retrospectivos , Queratocono/diagnóstico , Topografía de la Córnea/métodos , Tomografía de Coherencia Óptica , Paquimetría Corneal , Dilatación Patológica/diagnóstico , Estudios Transversales , Brasil , Córnea , Curva ROC
3.
Heliyon ; 8(11): e11699, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36468117

RESUMEN

Purpose: To investigate the relationship between Ortho-K contact lens design parameters and refractive power change of the eye through a parametric mathematical representation. Methods: The current study utilises fully anonymized records of 249 eyes, 132 right eyes, and 117 left eyes from subjects aged 14.1 ± 4.0 years on average (range 9-38 years) which were selected for secondary analysis processing. The data were split into 3 groups (G1 up to 35 days wear, from 10 to 35 days, G2 up to 99 days wear, more than 35-99 days & G3 more than 100 days wear) according to the length of time, in days, that the lenses were worn. Corneal shape was measured before and after contact lens wear using the Medmont E300 topographer, from which height and distance files were read by a custom-built MATLAB code to construct the corneal anterior surface independently. Changes in refractive power pre and post-Ortho-K wear were determined using constructed tangential refractive power maps from which both centrally flattened and annular steepened zones were automatically bounded, hence used to determine the refractive power change. Results: On average, flat Sim-K and steep Sim-K were reduced after Ortho-K lens wear by 1.6 ± 1.3 D and 1.3 ± 1.4 D respectively. The radius of the base curve was correlated with the mean central flattened zone power change strongly in G1 (R = 0.7, p < 0.001) and moderately in G2 (R = 0.4) and G3 (R = 0.4, p < 0.001). Hence, a strong correlation with the base curve was recorded in group G1 and moderate in G2 and G3. The reverse curve was very strongly correlated to the mean central flattened zone power change in G1 (R = 0.8, p < 0.001) and strongly correlated with G2 (R = 0.6, p < 0.001) and G3 (R = 0.7, p < 0.001). The reverse curve was also strongly correlated with the mean annular steepened zone power change among all groups G1, G2, and G3 (R = 0.7, R = 0.6 and R = 0.6) respectively (p < 0.001). Conclusions: Although the central corneal refractive power change was strongly correlated to the Ortho-K lens base curve, it characterized only 50% of the target power change. However, the annular steepened zone refractive power change appears to be a clearer predictor of target power change, as there appears to be a one-to-one inverse relationship with the target refractive power correction. Differences between these results and the literature may be a result of the topography software smoothing effect.

4.
Artículo en Inglés | MEDLINE | ID: mdl-32209975

RESUMEN

PURPOSE: To review the role of corneal biomechanics for the clinical evaluation of patients with ectatic corneal diseases. METHODS: A total of 1295 eyes were included for analysis in this study. The normal healthy group (group N) included one eye randomly selected from 736 patients with healthy corneas, the keratoconus group (group KC) included one eye randomly selected from 321 patients with keratoconus. The 113 nonoperated ectatic eyes from 125 patients with very asymmetric ectasia (group VAE-E), whose fellow eyes presented relatively normal topography (group VAE-NT), were also included. The parameters from corneal tomography and biomechanics were obtained using the Pentacam HR and Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). The accuracies of the tested variables for distinguishing all cases (KC, VAE-E, and VAE-NT), for detecting clinical ectasia (KC + VAE-E) and for identifying abnormalities among the VAE-NT, were investigated. A comparison was performed considering the areas under the receiver operating characteristic curve (AUC; DeLong's method). RESULTS: Considering all cases (KC, VAE-E, and VAE-NT), the AUC of the tomographic-biomechanical parameter (TBI) was 0.992, which was statistically higher than all individual parameters (DeLong's; p < 0.05): PRFI- Pentacam Random Forest Index (0.982), BAD-D- Belin -Ambrosio D value (0.959), CBI -corneal biomechanical index (0.91), and IS Abs- Inferior-superior value (0.91). The AUC of the TBI for detecting clinical ectasia (KC + VAE-E) was 0.999, and this was again statistically higher than all parameters (DeLong's; p < 0.05): PRFI (0.996), BAD-D (0.995), CBI (0.949), and IS Abs (0.977). Considering the VAE-NT group, the AUC of the TBI was 0.966, which was also statistically higher than all parameters (DeLong's; p < 0.05): PRFI (0.934), BAD- D (0.834), CBI (0.774), and IS Abs (0.677). CONCLUSIONS: Corneal biomechanical data enhances the evaluation of patients with corneal ectasia and meaningfully adds to the multimodal diagnostic armamentarium. The integration of biomechanical data and corneal tomography with artificial intelligence data augments the sensitivity and specificity for screening and enhancing early diagnosis. Besides, corneal biomechanics may be relevant for determining the prognosis and staging the disease.


Asunto(s)
Inteligencia Artificial , Córnea , Paquimetría Corneal , Topografía de la Córnea , Córnea/diagnóstico por imagen , Dilatación Patológica , Alemania , Humanos , Curva ROC , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda