Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Dermatol Ther ; 34(1): e14734, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33389778

RESUMEN

We present hybrid reconstruction of distal lateral "through-and-through" nasal defects (skin, cartilage, and mucosa) due to resection of tumor and/or infection. Retrospective descriptive study. The study was performed in multicenter clinics between July 2011 and September 2016. 13 patients with full thickness distal nasal defects secondary to tumor and/or infection were included. Defects included dorsal and/or caudal septum, upper lateral cartilage, or inner/outer nasal valve. Caudal-based turn-in flaps were planned and used to repair inner lining of nasal cavity. Conchal and septal cartilages were used as cartilage grafts. Skin defects were reconstructed with lateral nasal artery perforator flaps. All flaps healed uneventfully, without flap loss. Nasal passage collapse, adhesion, or difficulty in breathing were not seen. No hematoma, infection, and deformity at cartilage graft donor areas was observed. During nasal reconstruction, it is mandatory to consider 3D complex and functional structure of nose. The repair of skin defects may not be enough for functional restoration. We believe that single step reconstruction of full thickness nasal defects through hybrid reconstruction may lead to anticipated successful results.


Asunto(s)
Neoplasias Nasales , Colgajo Perforante , Rinoplastia , Humanos , Nariz/cirugía , Neoplasias Nasales/cirugía , Estudios Retrospectivos
2.
Surg Innov ; 25(2): 110-114, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29327648

RESUMEN

INTRODUCTION: Preoperative planning is an essential prerequisite for the success of plastic surgery. In procedures such as breast reduction, freehand drawings may be associated with a number of challenges during the determination of axes vertical and parallel to the surgical site. Furthermore, many procedures involve subjective maneuvers, such as attempts aimed at positioning both nipples on the same line and transferring nipple-areola complexes in a well-matched manner. Our newly designed instrument, that is, the goniometer (TG), aims to ensure metric measurements appropriate for the axes, and it may also be used in circumstances that require angle measurements. Moreover, it incorporates a canal system to facilitate surgical designing of the area, to which the nipple-areola complex will be transferred. METHOD: From April 2013 to September 2015, TG device was used in superior pedicle breast reduction operation of 96 patients and 50 of them were randomly selected for the purpose of study analyses. An additional randomly selected 50 patients, in whom surgical planning was based on conventional techniques were served as controls. At postoperative 1 year, symmetry analysis was carried out on patient photographs. RESULTS: No partial or total necrosis occurred at the nipple-areola complex, and symmetrical volume and shape could be achieved in all cases. TG device exhibited superiority in all criteria used for postoperative symmetry analyses (P < .05). CONCLUSION: We believe that this device may effectively accelerate the planning process in various types of plastic and aesthetic operations and may help ensure symmetry, especially in reduction mammoplasty and mastopexy.


Asunto(s)
Mama/cirugía , Procesamiento de Imagen Asistido por Computador/instrumentación , Mamoplastia/instrumentación , Mamoplastia/métodos , Adulto , Diseño de Equipo , Femenino , Humanos , Persona de Mediana Edad , Fotograbar , Teléfono Inteligente
3.
J Surg Res ; 209: 70-78, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28032573

RESUMEN

BACKGROUND: To describe a new design for an extended lateral thoracic artery (LTA) perforator flap and investigate its anatomical, dynamic, and potential territories. MATERIALS AND METHODS: To assess vascular territories, rats were randomized according to LTA perforator flap type into the surgical groups A, hemidorsal island flap; B, entire dorsal island flap; and C, reduced-size dorsal island flap. RESULTS: On postsurgical day 7, the surviving flap areas were 95%, 92%, and 89% in groups A, B, and C, respectively. Necrosis most commonly occurred in the contralateral LTA territories in groups B and C. The immunoreactivities of intercellular adhesion molecule 1 and vascular endothelial growth factor receptor 2 in dynamic territories, as choke vessel markers, were increased. CONCLUSIONS: We clarified the LTA perforator flap nomenclature and defined its pedicle course and anastomosing patterns; furthermore, we demonstrated that the LTA perforator did not anastomose with its counterpart because of its unidirectional, oblique, and craniocaudal course. The LTA perforator flap was found to be a good model comprising multiple vascular territories and exhibiting continuous necrosis.


Asunto(s)
Colgajo Perforante/irrigación sanguínea , Arterias Torácicas , Angiografía , Animales , Inmunohistoquímica , Masculino , Distribución Aleatoria , Ratas Sprague-Dawley
4.
J Surg Res ; 206(1): 126-132, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27916351

RESUMEN

BACKGROUND: Chimeric osteomyocutaneous flaps harvested from the subscapular artery system have been used in clinical practice. We describe the use of a novel circumflex scapular artery myocutaneous and/or vascularized scapular chimeric flap in a rat model and demonstrate optimal skin flap dimensions. MATERIALS AND METHODS: An 8 × 4-cm-rectangular skin flap based on the circumflex scapular artery flap was harvested, and the mean percentage of the surviving flap area and the necrotic area were calculated to be 71% ± 17.9% and 29% ± 17.9%, respectively. Using flap dimensions determined in the first part of our study, a 4 × 3-cm quadrangular portion of skin was marked over the scapula, and the serratus anterior muscle and a portion of the scapular bone were included in our chimeric flap model. RESULTS: The mean percentages of the surviving flap and necrotic areas were 74% ± 6% and 25% ± 6%, respectively. Microangiographic and histologic studies revealed the vascularity of the skin island and identified the branches of the circumflex scapular artery that supplied the bone and muscle. CONCLUSIONS: The circumflex scapular artery myocutaneous and/or vascularized partial scapular chimeric flap may be considered a branch-based chimeric flap and can be an acceptable flap model due to its simplicity, reliability, and consistent vascularity. Furthermore, this flap may have potential applications in studying chimeric flap hemodynamics.


Asunto(s)
Colgajo Miocutáneo/irrigación sanguínea , Colgajo Miocutáneo/cirugía , Procedimientos de Cirugía Plástica/métodos , Escápula/irrigación sanguínea , Escápula/cirugía , Animales , Arterias/cirugía , Masculino , Microcirugia/métodos , Colgajo Miocutáneo/patología , Ratas , Ratas Sprague-Dawley , Escápula/patología
5.
Microsurgery ; 36(7): 598-603, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27735080

RESUMEN

INTRODUCTION: In this report we present two cases of gunshot injury related midfoot defects, reconstructed with a chimeric partial scapula and latissimus dorsi muscle flap and short perforator-based skin flap. The first case, a 14 years old male, had 10 × 8 cm medial plantar and 6 × 4 cm dorsal foot defects and the second case, a 55 years old female, had only 8 × 6 cm dorsal foot defect. In both cases the defects were associated with fractures, one with lateral cuneiform and cuboid with 90% bone loss and the other with navicular bone, respectively. After 6 months, the patients could walk well without support, and radiographs confirmed bony union. A chimeric partial scapula and latissimus dorsi muscle flap and short perforator-based skin flap may be used for the reconstruction of combined bony and soft tissue defects of the midfoot and to promote bone healing. © 2016 Wiley Periodicals, Inc. Microsurgery 36:598-603, 2016.


Asunto(s)
Traumatismos de los Pies/cirugía , Colgajos Tisulares Libres/trasplante , Procedimientos de Cirugía Plástica/métodos , Escápula/trasplante , Traumatismos de los Tejidos Blandos/cirugía , Músculos Superficiales de la Espalda/trasplante , Heridas por Arma de Fuego/cirugía , Adolescente , Femenino , Huesos del Pie/lesiones , Huesos del Pie/cirugía , Fracturas Óseas/cirugía , Humanos , Masculino , Persona de Mediana Edad
6.
Facial Plast Surg ; 32(4): 431-7, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27494588

RESUMEN

Local skin flaps are important tools for performing plastic surgery. Skin flaps are used for closure of defects after tumor excision or in tissue losses after trauma. However, problems associated with these flaps are commonly encountered, particularly in areas of marginal necrosis. Bosentan is a vasodilator that exerts its effect through endothelin receptor blockade, and has been shown to prevent ischemic tissue damage. However, no reports have addressed the effect of bosentan on skin flaps. The aim of the study was to investigate the effects of bosentan, which may be applied clinically to promote survival of ischemic skin flaps. A modified McFarlane flap was elevated in the dorsum of 20 Albino Wistar rats with a width-to-length ratio of 3 to 10 cm, respectively, with the caudal base. Perioperatively, 0.9% of physiologic NaCl and injectable distilled water of identical volume were injected into rats in Group 1 (n = 10), and 5 mg/kg bosentan was injected intraperitoneally into rats in Group 2 (n = 10). All of the rats were followed up for 7 days postoperatively. The surviving parts of the flaps were measured at the end of day 7. Acute and chronic inflammation, amount of granulation tissue, fibroblast maturation, amount of collagen, and amounts of reepithelialization and neovascularization present in the ischemic zones of the distal parts of the flaps were evaluated histopathologically, and results were compared statistically. The mean flap survivals were 61.1% in Group 1 and 91.1% in Group 2; the percentage of the surviving flap area in Group 2 was higher than that in Group 1 (p < 0.005). In both groups, there was significantly less acute inflammation in the ischemic zones in Group 2 than in Group 1 (p < 0.005). No significant difference was found in the amounts of chronic inflammation and granulation tissue between the two groups (p > 0.005). Fibroblast maturation, amount of collagen, and amounts of reepithelialization and neovascularization investigated in Group 2 were statistically significantly higher than those in Group 1 (p < 0.005). We believe that bosentan may be used prophylactically to increase survival in risky skin flaps because it decreases ischemic necrosis distal to skin flaps, thus exerting favorable effects on flap survival.


Asunto(s)
Antagonistas de los Receptores de Endotelina/farmacología , Isquemia/tratamiento farmacológico , Sulfonamidas/farmacología , Colgajos Quirúrgicos/irrigación sanguínea , Colgajos Quirúrgicos/patología , Animales , Bosentán , Antagonistas de los Receptores de Endotelina/uso terapéutico , Inflamación/patología , Isquemia/patología , Masculino , Neovascularización Fisiológica/efectos de los fármacos , Ratas , Ratas Wistar , Repitelización/efectos de los fármacos , Sulfonamidas/uso terapéutico
7.
Int Braz J Urol ; 42(1): 113-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27136476

RESUMEN

BACKGROUND: Circumcision is performed as a routine operation in many countries, more commonly for religious and cultural reasons than for indicated conditions, such as phimosis and balanitis. There are many techniques available, and recently electrocautery and both Nd:YAG and CO2 lasers, instead of blades, have been used for skin and mucosal incisions. However, the infection risk in circumcisions performed using a CO2 laser was 10% higher. There are also reports of sutureless procedures using cyanoacrylate, but these have higher risks of hematoma and hemorrhage. We combined a CO2 laser and cyanoacrylate to shorten the operation time and to decrease bleeding complications. MATERIALS AND METHODS: Circumcisions were performed under general anesthesia with CO2 laser and cyanoacrylate combination in 75 6-9-year-old boys between May 2013 and August 2014 only for religious reasons. As a control, we compared them retrospectively with 75 age-matched patients who were circumcised using the conventional guillotine method in our clinic. RESULTS: No hematomas, bleeding, or wound infections were observed. One wound dehiscence (1.33%) occurred during the early postoperative period and healed without any additional procedures. The median operating time was 7 (range 6-9) minutes. The conventional guillotine group comprised one hematoma (1.3%), two wound dehiscences (2.6%), and two hemorrhages (2.6%), and the median operating time was 22 (range 20-26) minutes. The difference in surgical time was significant (p<0.001), with no significant difference in the rate of complications between the two groups. CONCLUSION: The combined CO2 laser and cyanoacrylate procedure not only decreased the operating time markedly, but also eliminated the disadvantages associated with each individual procedure alone.


Asunto(s)
Circuncisión Masculina/métodos , Cianoacrilatos/uso terapéutico , Láseres de Gas/uso terapéutico , Adhesivos Tisulares/uso terapéutico , Niño , Circuncisión Masculina/efectos adversos , Terapia Combinada , Humanos , Masculino , Tempo Operativo , Complicaciones Posoperatorias , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Técnicas de Sutura , Resultado del Tratamiento
8.
Dermatol Surg ; 41(9): 1024-9, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26317808

RESUMEN

Skin grafts are a standard option for closing skin defects that cannot be closed primarily. A split -thickness skin graft entirely transfers the epidermis and a part of the dermal layer to the wound site. Using conventional techniques, the skin graft is fixed to the wound using sutures and kept closed for 3 to 7 days with a pressed bolster dressing. Continued care includes applying routine graft dressings after the bolster dressing has been removed. The use of fibrin glue and cyanoacrylate derivatives-which shortens the duration of surgery and improves graft fixation to the recipient bed-has become widespread. However, applying fibrin glue during skin graft surgery is limited because there are considerable disadvantages in terms of preparation and cost. Many studies have been conducted on the use of cyanoacrylate derivatives during skin grafting; however, few reports have investigated the effects of cyanoacrylate derivatives on skin graft survival and related histopathologic changes.In this study, the authors used n-butyl cyanoacrylate to prepare split-thickness skin grafts that were subsequently applied to Wistar albino rats, and the authors evaluated the results both histopathologically and macroscopically. The authors also statistically analyzed the effects of graft fixation according to surgical duration. The findings of authors suggest that n-butyl cyanoacrylate can be safely applied during split-thickness skin graft surgery because it significantly reduces surgical duration, demonstrates substantial advantages in terms of graft fixation and monitoring, and, most importantly, demonstrates no notable disadvantages in comparison with conventional methods.


Asunto(s)
Enbucrilato/farmacología , Trasplante de Piel/métodos , Cicatrización de Heridas/efectos de los fármacos , Animales , Masculino , Modelos Animales , Ratas , Ratas Wistar
9.
Aesthetic Plast Surg ; 39(4): 644-5, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26044394

RESUMEN

Skin tags (acrochordon) are skin colored or hyperpigmented, usually pedunculated benign skin lesions and often occur on the neck, axilla, and groin regions. It is difficult choice to excise these multiple, widespread, and pedinculated lesions with or without local anesthesia. One option is to infiltrate local anesthesia to every single skin tag, while cutting pedicle with single move is another option. However, both of these options are painful to some degree. We routinely use ethyl chloride spray anesthesia for skin tag excision with micro-scissor and micro-forceps. We received positive feedback from patients, who underwent skin tag excision before with conventional techniques. They declare that ethyl chloride procedure is more comfortable and painless.


Asunto(s)
Anestésicos Locales/uso terapéutico , Cloruro de Etilo/uso terapéutico , Enfermedades de la Piel/cirugía , Humanos , Factores de Tiempo
10.
Burns ; 49(2): 444-454, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35654705

RESUMEN

AIM: Burn injuries are one of the most devastating injuries. Saving the zone of stasis decreases burn size, morbidity, and mortality. Tarantula cubensis (TC) increases epithelization of wounds, and increases wound contraction. In this study, we investigated the effects of TC on the stasis zone. MATERIALS AND METHODS: 36 Wistar albino female rats were divided into 3 groups. Using brass comb burn model, at days 0 and 3, physiological serum solution in group 2, TC injection in group 3and no injection in group 1 was applied. Thermal and normal images were taken on day 10 and rats were sacrificed for histopathological examination. RESULTS: We found a statistically significant difference between the 1st and 3rd group, 2nd and 3rd group regarding viable wound areas (p < 0.05), temperature difference (body-stasis zone) and mean body temperature (p < 0.05). We found no statistically significant difference between groups regarding neovascularization, inflammatory density, and vital cutaneous appendages. We found a statistically significant difference in epithelial layer thickness between the1st and 3rd groups, 2nd and 3rd groups(p < 0.05). CONCLUSION: TC increases stasis zone viability macroscopically, increases epithelial layer thickness histopathologically, thus it promotes wound healing in burn wounds. This increase in stasis zone viability was also established with thermal imaging.


Asunto(s)
Quemaduras , Ratas , Animales , Quemaduras/patología , Ratas Wistar , Cicatrización de Heridas , Piel/patología , Neovascularización Patológica/patología , Modelos Animales de Enfermedad
16.
Aesthetic Plast Surg ; 33(5): 770-3, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19495857

RESUMEN

BACKGROUND: Nipple reconstruction is the last step in breast reconstruction. An entirely satisfying breast reconstruction can be achieved only with a symmetrically placed and ideally shaped nipple-areola complex. Several techniques and modifications have been described for nipple-areola reconstruction but long-term projection loss is still a problem in nipple reconstruction. METHODS: Between January 2005 and October 2008, 13 female patients underwent 19 nipple reconstructions in our department. Among these patients, seven underwent breast reconstruction with a DIEP flap following unilateral mastectomy, and six were diagnosed with gigantomasty and underwent bilateral breast reduction with a modification of free nipple grafting. Our method for nipple reconstruction relies on a vertically oriented bipedicled flap with horizontally oriented extensions from the mid-portion. RESULTS: Nineteen nipple reconstructions in 13 patients were evaluated and the mean follow-up period was 15 months. We did not see any necrosis or any significant projection loss in our cases. Patients' satisfaction was noted as high and the results were evaluated as pleasing. CONCLUSION: We present a new technique that uses a bipedicled flap, oriented vertically. A rich blood supply to the flap may be the principal cause for long-lasting nipple projection.


Asunto(s)
Mamoplastia/métodos , Pezones/cirugía , Trasplante de Piel/métodos , Colgajos Quirúrgicos , Adulto , Mama/fisiopatología , Mama/cirugía , Implantes de Mama , Estudios de Cohortes , Estética , Femenino , Estudios de Seguimiento , Rechazo de Injerto , Supervivencia de Injerto , Humanos , Persona de Mediana Edad , Satisfacción del Paciente , Procedimientos de Cirugía Plástica/métodos , Estudios Retrospectivos , Medición de Riesgo , Resultado del Tratamiento
17.
Burns ; 42(2): 243-5, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26777447

RESUMEN

The Z-plasty is used frequently in hand surgery to release post-burn scar contractures. Correct angles and equalization of each limb are the most important parts of the Z-plasty technique. A simple ruler is enough for equalization of limb but a goniometer is needed for accuracy and equalization of angles. Classically, angles of 30°, 45°, 60°, 75°, and 90° are used. These angles are important when elongating a contracture line or decreasing tension. Our method uses only trigonometry coefficients and a simple ruler, which is easily obtained and sterilized, enabling surgeons to perform all types of Z-plasty perfectly without measuring angles using a goniometer.


Asunto(s)
Artrometría Articular/métodos , Quemaduras/cirugía , Cicatriz/cirugía , Contractura/cirugía , Traumatismos de la Mano/cirugía , Procedimientos de Cirugía Plástica/métodos , Quemaduras/complicaciones , Cicatriz/etiología , Contractura/etiología , Traumatismos de la Mano/complicaciones , Humanos
18.
Br J Oral Maxillofac Surg ; 54(6): 664-8, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27090026

RESUMEN

The orbital floor is the thinnest part of the orbital wall, and in 20% of all maxillofacial injuries it is fractured. Autografts, allografts, and alloplastic materials are used in reconstruction, but there is no consensus about which material is the most appropriate. Nail is a semirigid material that is easy to reshape and is not antigenic. Alloplastic materials, which are used in reconstructions of the orbital floor, have various complications and are expensive. Autografts have donor-site problems, high rates of resorption, and take a long time to do. We created bilateral 10mm defects in the orbital floors in 18 New Zealand rabbits. We reconstructed the left orbital floors with double-ground human nail while the right orbital floors were left open as controls. The orbital floors were examined macroscopically and microscopically at 4, 8, and 12 weeks postoperatively, and there were no macroscopic signs of infection, inflammation, or extrusion. Forced duction tests showed that it was possible to induce movement of the eyeball for all 18 of the reconstructed sides throughout the observation period, and in 14 of the 18 rabbits on the control sides. Positive forced duction test shows us that orbital muscles are trapped in orbital floor defect and due to this movement of eyeball is restricted. Acute and chronic inflammation, fibrosis, vascularisation, and the presence of foreign body giant cells were evaluated microscopically. Acute inflammation and the presence of foreign body giant cells were recorded as mild, whereas fibrosis, chronic inflammation, and vascularisation were severe, as were epithelialisation on the maxillary sinus side of the nails, calcification, and progression of collagen. We found no signs of resorption of the nails.


Asunto(s)
Fracturas Orbitales/cirugía , Procedimientos de Cirugía Plástica , Trasplante Autólogo , Animales , Humanos , Traumatismos Maxilofaciales , Uñas/trasplante , Órbita , Conejos
19.
Ann Med Surg (Lond) ; 5: 49-51, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26862395

RESUMEN

INTRODUCTION: In parallel with technological improvements, humankind encounter with equipments/devices transforming chemical energy to electrical energy. Especially automobile batteries, watch and mobile phone batteries are the most encountered ones. In the literature, there are mainly facial burn cases due to mobile phone battery explosion. On the other hand very few examples of serious lower limb. injury is present. PRESENTATION OF CASE: 12-year-old female patient referred to emergency room with skin and soft tissue injuries on bilateral anteromedial thigh area as a result of battery explosion. The widest axis of skin defect was approximately 16 × 8 cm on the right side, and 17 × 4 cm on the left side. In addition, there were tattooing caused by chemical injury and multiple pin-point like lesions extending to dermal level on anterior region of thigh. Chemically dirty and necrotized dermal and subdermal tissues were debrided and foreign materials were removed from regions with multiple tattooing. Left thigh was closed primarily. In order to close the defect on right anterior thigh, skin flap from right medial thigh is advanced in Y-V fashion. DISCUSSION: Battery explosion causing lower extremity tissue defect is a type of injury that is rarely seen in the literature. Regardless of battery size and energy level, they should be considered as potential explosive material and protector masks, clothing should be worn during contact with this type of material.

20.
J Plast Surg Hand Surg ; 50(5): 291-7, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27109505

RESUMEN

BACKGROUND: The main purpose of this study was to assess the effects of ozone gas on the viability of flaps for reconstruction and to determine the optimum application method. The antioxidant, immunomodulatory, and reperfusion effects of ozone gas have been previously assessed, and successful results have been reported. However, only one study has investigated the effect of ozone gas on flap viability. In the present study, it was hypothesised that the antioxidant and reperfusion effects of ozone gas would enhance flap viability. METHODS: Forty female Wistar rats were randomly divided into four groups of 10 rats each. A cranial-based, 3 × 11 cm modified McFarlane flap including the panniculus carnosus was raised from the dorsum of a rat and re-sutured to its own bed using 3/0 sharp propylene. Group 1 (n = 10): no pharmacological agent was used after the operation. Group 2 (n = 10): vegetable (olive) oil group; vegetable-oil-impregnated gauze was used as a dressing for 7 days. Group 3 (n = 10): Vegetable (olive) oil with ozone peroxide group; vegetable oil with ozone peroxide-impregnated gauze was used as a dressing for 7 days. Group 4 (n = 10): Hemo-ozone therapy group; hemo-ozone therapy was applied rectally once every day for 7 days. All rats were sacrificed at the end of week 1 and assessed macroscopically and histopathologically. RESULTS: The proportion of substantive necrosis was less in group 4 than in the other three groups. Survival area ratios were better in groups 2 and 3 than in group 1; however, there was no significant difference between groups 2 and 3. No significant differences in the histopathological scores were observed among the groups. CONCLUSION: Ozone gas enhanced flap viability. No differences in flap viability were observed between the vegetable oil and vegetable oil with ozone peroxide groups. The greatest benefit ratios were found in the hemo-ozone therapy group.


Asunto(s)
Antioxidantes/farmacología , Vendajes , Supervivencia de Injerto/efectos de los fármacos , Ozono/farmacología , Colgajos Quirúrgicos , Animales , Femenino , Ratas Wistar
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda