Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
2.
Clin Orthop Relat Res ; 473(3): 831-8, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24664193

RESUMEN

BACKGROUND: The treatment of choice for distal femur malignancies in skeletally immature patients remains controversial. An expandable endoprosthesis device (Repiphysis Limb Salvage System; Wright Medical Technology, Arlington, TN, USA) allows for limb preservation and noninvasive lengthening but has been associated with significant complications; however, the extent and implications of bone loss associated with this implant have not been reported. QUESTIONS/PURPOSES: Our goals were to report (1) the 2-year minimum clinical outcomes after placement of the Repiphysis expandable prosthesis for pediatric distal femur malignancies; (2) the complications associated with this prosthesis; (3) the failure rate of this prosthesis; and (4) the revision alternatives available for salvage procedures. METHODS: Between 2002 and 2010, one surgeon (SG) treated all skeletally immature patients (mean age, 10.1 years; range, 4.7-13.6 years) with distal femoral osteosarcoma using a Repiphysis expandable prosthesis. Of the 12 patients who met these criteria, two were excluded for death from disease before 2 years, and mean followup for the remaining 10 was 72 months (range, 26-119 months). Medical records were retrospectively reviewed for complications and clinical outcomes, as assessed by the Musculoskeletal Tumor Society (MSTS) scoring system. Radiographs at final followup were reviewed for bone loss and analyzed by the two senior authors (SG, WWV) to determine reconstruction options available for future revisions. RESULTS: MSTS scores averaged 67%, and we observed 37 implant-related complications requiring a total of 15 reoperations. Six patients underwent implant revisions with aseptic loosening being the predominant mode of failure; ultimately, four of these were converted to adult modular oncology prostheses, and two underwent total femoral replacements. Bone loss in this series was severe in terms of femoral length, cortical thinning, and metadiaphyseal compromise, and most patients will not have sufficient bone stock to permit future revision using standard stem fixation. CONCLUSIONS: The bone loss around the stem of this prosthesis limits subsequent revision options, often resulting in a total femoral prosthesis. Although the decision to use the Repiphysis device must be made on an individual basis, surgeons should recognize the potential for significant bone compromise limiting revision options and consider other options. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Asunto(s)
Neoplasias Femorales/cirugía , Recuperación del Miembro/efectos adversos , Osteosarcoma/cirugía , Prótesis e Implantes/efectos adversos , Implantación de Prótesis/efectos adversos , Adolescente , Niño , Preescolar , Femenino , Neoplasias Femorales/diagnóstico por imagen , Humanos , Recuperación del Miembro/métodos , Masculino , Osteosarcoma/diagnóstico por imagen , Diseño de Prótesis , Radiografía , Reoperación , Estudios Retrospectivos
3.
Am J Physiol Lung Cell Mol Physiol ; 300(4): L605-14, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21296894

RESUMEN

Allergens are diverse proteins from mammals, birds, arthropods, plants, and fungi. Allergens associated with asthma (asthmagens) share a common protease activity that may directly impact respiratory epithelial biology and lead to symptoms of asthma. Alternaria alternata is a strong asthmagen in semiarid regions. We examined the impact of proteases from A. alternata on lung inflammation in vivo and on cleaving protease-activated receptor-2 (PAR(2)) in vitro. A. alternata filtrate applied to the airway in nonsensitized Balb/c mice induced a protease-dependent lung inflammation. Moreover, A. alternata filtrate applied to human bronchial epithelial cells (16HBE14o-) induced changes in intracellular Ca(2+) concentration ([Ca(2+)](i)), consistent with PAR(2) activation. These effects were blocked by heat inactivation or by serine protease inhibition of A. alternata filtrates, and mimicked by PAR(2) specific ligands SLIGRL-NH(2) or 2-furoyl-LIGRLO-NH(2), but not the PAR(1)-specific ligand TFLLR-NH(2). Desensitization of PAR(2) in 16HBE14o- cells with 2-furoyl-LIGRLO-NH(2) or trypsin prevented A. alternata-induced [Ca(2+)](i) changes while desensitization of PAR(1), PAR(3), and PAR(4) with thrombin had no effect on A. alternata-induced Ca(2+) responses. Furthermore, the Ca(2+) response to A. alternata filtrates was dependent on PAR(2) expression in stably transfected HeLa cell models. These data demonstrate that A. alternata proteases act through PAR(2) to induce rapid increases in human airway epithelial [Ca(2+)](i) in vitro and cell recruitment in vivo. These responses are likely critical early steps in the development of allergic asthma.


Asunto(s)
Alternaria/enzimología , Células Epiteliales/microbiología , Células Epiteliales/patología , Neumonía/inmunología , Neumonía/microbiología , Receptor PAR-2/metabolismo , Serina Proteasas/inmunología , Animales , Calcio/metabolismo , Señalización del Calcio/efectos de los fármacos , Movimiento Celular/efectos de los fármacos , Desensibilización Inmunológica , Células Epiteliales/efectos de los fármacos , Regulación de la Expresión Génica/efectos de los fármacos , Células HeLa , Humanos , Espacio Intracelular/efectos de los fármacos , Espacio Intracelular/metabolismo , Pulmón/patología , Linfocitos/efectos de los fármacos , Linfocitos/inmunología , Ratones , Ratones Endogámicos BALB C , Neumonía/patología , Receptor PAR-2/agonistas , Receptor PAR-2/genética , Trombina/farmacología
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda