Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
BMC Musculoskelet Disord ; 18(1): 155, 2017 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-28407736

RESUMEN

BACKGROUND: Enchondroma, a subtype of chondroma, originates from the medullary cavity of the bone and produces an expansile growth pattern. Enchondroma located in the spine is rare and a few cases of large thoracic enchondroma have been reported. The authors document a rare case of large enchondroma in the thoracic spine of a 49-year-old woman, and discuss its clinical, radiological and histopathological characteristics. CASE PRESENTATION: The patient presented with rapidly progressive and severe pain on her upper back. Magnetic resonance imaging revealed an expansile lesion at the posterior elements of T3 that was hypointense on T1-weighted images and mixed iso- to hyperintense on T2-weighted images. Administration of gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) resulted in heterogeneous enhancement. During surgery, a large tumor of 4.2cm × 4.7cm × 2.1cm was resected along with the lamina and spinous process. Histological examination revealed that the tumor consisted of mature hyaline cartilage with typical chondrocytes, indicating that it was an enchondroma. CONCLUSIONS: Despite its benign-growing nature, enchondroma should be examined closely for signs of enchondromatosis and enchondrosarcoma. Complete surgical resection is the treatment of choice for immediate relief of symptoms and avoidance of recurrence.


Asunto(s)
Dolor de Espalda/cirugía , Condroma/diagnóstico , Recurrencia Local de Neoplasia/prevención & control , Neoplasias de la Columna Vertebral/diagnóstico , Vértebras Torácicas/patología , Dolor de Espalda/etiología , Condroma/complicaciones , Condroma/patología , Condroma/cirugía , Medios de Contraste , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Cartílago Hialino/patología , Imagen por Resonancia Magnética , Persona de Mediana Edad , Procedimientos Ortopédicos , Osteólisis/diagnóstico por imagen , Osteólisis/etiología , Radiografía Torácica , Neoplasias de la Columna Vertebral/complicaciones , Neoplasias de la Columna Vertebral/patología , Neoplasias de la Columna Vertebral/cirugía , Vértebras Torácicas/diagnóstico por imagen , Tomografía Computarizada por Rayos X
2.
Int J Surg ; 42: 83-89, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28456707

RESUMEN

BACKGROUND: Spinal endoscopy has been widely applied in lumbar discectomy and decompression. However, endoscopic lumbar interbody fusion still remains a technical challenge due to the limited space within the working trocar for cage implantation. The purpose of this study was to investigate the feasibility and effectiveness of using a narrow-surface fusion cage in full endoscopic minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for the treatment of lumbar degenerative disease. MATERIALS AND METHODS: From Jun 2013 to Dec 2014, a total of 42 patients (23 males, 19 females) underwent full endoscopic MIS-TLIF at our hospital was recruited. An 8-mm-wide narrow-surface fusion cage was selected for all cases. Perioperative parameters and complications were recorded. Comparisons on visual analog scale (VAS) and oswestry disability index (ODI) scores before and after surgery were performed. At the last follow-up, Nakai grading system was applied to assess patients' satisfaction; meanwhile, interbody fusion was evaluated by computed tomography. RESULTS: Mean operation time was 233.1 ± 69.5 min, and mean blood loss during surgery was 221.8 ± 98.5 ml. Two patients (4.8%) developed neurological complications. Postoperative follow-up ranged from 24 to 36 months (mean 27.6 ± 3.8 months). VAS and ODI scores were significantly improved 3 months after surgery and at the final follow-up, respectively (P < 0.05). Outcome of surgery was graded as excellent for 32 patients, good for 8 patients, and acceptable for 2 patients, corresponding to a success rate ("good" and "excellent") of 95.2%. Thirty-nine of the 42 patients demonstrated solid interbody fusion at the last follow-up, indicating a fusion rate of 92.9%. CONCLUSION: Application of a narrow-surface fusion cage in full endoscopic MIS-TLIF for the treatment of lumbar degenerative disease is feasible and effective. The clinical outcome and fusion success of this procedure were acceptable and promising.


Asunto(s)
Degeneración del Disco Intervertebral/cirugía , Vértebras Lumbares/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Fusión Vertebral/métodos , Adulto , Anciano , Descompresión Quirúrgica , Endoscopía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Tomografía Computarizada por Rayos X
3.
Postgrad Med ; 129(7): 762-767, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28627954

RESUMEN

OBJECTIVES: Degenerative changes of endplates in older patients and tilting of vertebral body in lumbosacral lordosis could make an accurate identification of endplates for the Cobb measurement difficult. Pedicles have been proposed as alternative landmarks because they are usually better visualized, and offer similar clinical validity to the endplates. The objective of this study was to investigate the reliability of the pedicle method of Cobb measurement in degenerative lumbar scoliosis and compare it with the traditional endplate method. METHODS: Two hundred and eighty-four radiographs of degenerative lumbar scoliosis were evaluated. The radiographs were classified into groups based on the patient's age (< 60 years, 60 to 80 years, and > 80 years), level of lower end vertebra (LEV) (LEV at L5, and LEV at or above L4), and curve severity (< 20°, 20° to 40°, and > 40°). Three observers independently measured the radiographs using the endplate and pedicle methods twice with an interval of 1 week. The intra- and interobserver reliabilities were calculated using intraclass correlation coefficients (ICC). RESULTS: The intra- and interobserver ICC values were better for all observers in the > 80 years age group using the pedicle method. The intraobserver ICC values of pedicle method were also better in the LEV at L5 group, and the interobserver ICC values showed a slightly better consistency with the pedicle method. For patients with > 40° curves, the intraobserver ICC values for all observers as well as interobserver ICC values were better using the endplate method. CONCLUSION: The reliabilities of the endplate and pedicle methods for degenerative lumbar scoliosis were both excellent. The pedicle method might be better in older patients (> 80 years) and those with LEV at L5; while the endplate method could have some strength in severe cases (> 40°).


Asunto(s)
Lordosis/diagnóstico por imagen , Placa Motora/diagnóstico por imagen , Escoliosis/diagnóstico por imagen , Vértebras Torácicas/diagnóstico por imagen , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
4.
Int J Clin Exp Med ; 7(11): 3964-73, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25550904

RESUMEN

The aim of this study is to evaluate the therapeutic efficacy of patients with lumbar degeneration and instability treated with percutaneous pedicle screw fixation and minimally invasive lumbar interbody fusion. Twenty-one patients were selected in our hospital from November, 2012 to March, 2013. The patients with an average age 55.62 years, including 8 vertebral spondylolisthesis, 4 lumbar intervertebral disc herniation, and 9 lumbar spinal canal stenosis cases. All the patients were managed to take the lumbar MRI and radiographs. The comparison of preoperative and postoperative (3 days, 2 weeks, 3 months) VAS and ODI score were analyzed. The results indicated that VAS scores were 7.14 ± 0.79 before operation, and 5.19 ± 0.81 in 3 days after operation, 4 ± 0.84 after 2 weeks, and 2.67 ± 0.66 after 3 months. The pain was relieved, and the postoperative VAS score was lower than that before treatment (P < 0.05). ODI score was 55.8 ± 11.4 before operation, 47.38 ± 9.38 after 3 days, 41.38 ± 8.09 after 2 weeks, 35.76 ± 4.50 after 3 months. ODI score was obviously decreased (P < 0.05). In conclusion, percutaneous pedicle screw fixation combined with minimally invasive interbody fusion is a safe, effective, feasible minimally invasive spine operation, with worthy for spreading.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda