Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur Radiol ; 27(5): 1858-1866, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27553936

RESUMEN

OBJECTIVES: To measure benign and malignant prostate tissue stiffness using shear-wave elastography (SWE). METHODS: Thirty consecutive patients underwent transrectal SWE in the axial and sagittal planes before prostatectomy. After reviewing prostatectomy specimens, two radiologists measured stiffness in regions corresponding to cancers, lateral and median benign peripheral zone (PZ) and benign transition zone (TZ). RESULTS: Cancers were stiffer than benign PZ and TZ. All tissue classes were stiffer on sagittal than on axial imaging, in TZ than in PZ, and in median PZ than in lateral PZ. At multivariate analysis, the nature of tissue (benign or malignant; P < 0.00001), the imaging plane (axial or sagittal; P < 0.00001) and the location within the prostate (TZ, median PZ or lateral PZ; P = 0.0065) significantly and independently influenced tissue stiffness. On axial images, the thresholds maximising the Youden index in TZ, lateral PZ and median PZ were respectively 62 kPa, 33 kPa and 49 kPa. On sagittal images, the thresholds were 76 kPa, 50 kPa and 72 kPa, respectively. CONCLUSIONS: SWE can distinguish prostate malignant and benign tissues. Tissue stiffness is influenced by the imaging plane and the location within the gland. KEY POINTS: • Prostate cancers were stiffer than the benign peripheral zone • All tissue classes were stiffer on sagittal than on axial imaging • All tissue classes were stiffer in the transition zone than in the peripheral zone • All tissue classes were stiffer in the median than in the lateral peripheral zone • Taking into account imaging plane and zonal anatomy can improve cancer detection.


Asunto(s)
Próstata/diagnóstico por imagen , Hiperplasia Prostática/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Anciano , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Prospectivos , Próstata/cirugía , Antígeno Prostático Específico/sangre , Prostatectomía , Hiperplasia Prostática/sangre , Hiperplasia Prostática/cirugía , Neoplasias de la Próstata/sangre , Neoplasias de la Próstata/cirugía
2.
Radiology ; 280(1): 117-27, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26859255

RESUMEN

Purpose To assess the intermanufacturer variability of quantitative models in discriminating cancers with a Gleason score of at least 7 among peripheral zone (PZ) lesions seen at 3-T multiparametric magnetic resonance (MR) imaging. Materials and Methods An institutional review board-approved prospective database of 257 patients who gave written consent and underwent T2-weighted, diffusion-weighted, and dynamic contrast material-enhanced imaging before prostatectomy was retrospectively reviewed. It contained outlined lesions found to be suspicious for malignancy by two independent radiologists and classified as malignant or benign after correlation with prostatectomy whole-mount specimens. One hundred six patients who underwent imaging with 3-T MR systems from two manufacturers were selected (data set A, n = 72; data set B, n = 34). Eleven parameters were calculated in PZ lesions: normalized T2-weighted signal intensity, skewness and kurtosis of T2-weighted signal intensity, T2 value, wash-in rate, washout rate, time to peak (TTP), mean apparent diffusion coefficient (ADC), 10th percentile of the ADC, and skewness and kurtosis of the histogram of the ADC values. Parameters were selected on the basis of their specificity for a sensitivity of 0.95 in diagnosing cancers with a Gleason score of at least 7, and the area under the receiver operating characteristic curve (AUC) for the models was calculated. Results The model of the 10th percentile of the ADC with TTP yielded the highest AUC in both data sets. In data set A, the AUC was 0.90 (95% confidence interval [CI]: 0.85, 0.95) or 0.89 (95% CI: 0.82, 0.94) when it was trained in data set A or B, respectively. In data set B, the AUC was 0.84 (95% CI: 0.74, 0.94) or 0.86 (95% CI: 0.76, 0.95) when it was trained in data set A or B, respectively. No third variable added significantly independent information in any data set. Conclusion The model of the 10th percentile of the ADC with TTP yielded accurate results in discriminating cancers with a Gleason score of at least 7 among PZ lesions at 3 T in data from two manufacturers. (©) RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Medios de Contraste , Estudios de Evaluación como Asunto , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Estudios Prospectivos , Próstata/diagnóstico por imagen , Próstata/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Radiology ; 275(1): 144-54, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25423145

RESUMEN

PURPOSE: To assess the factors influencing multiparametric (MP) magnetic resonance (MR) imaging accuracy in estimating prostate cancer histologic volume (Vh). MATERIALS AND METHODS: A prospective database of 202 patients who underwent MP MR imaging before radical prostatectomy was retrospectively used. Institutional review board approval and informed consent were obtained. Two independent radiologists delineated areas suspicious for cancer on images (T2-weighted, diffusion-weighted, dynamic contrast material-enhanced [DCE] pulse sequences) and scored their degree of suspicion of malignancy by using a five-level Likert score. One pathologist delineated cancers on whole-mount prostatectomy sections and calculated their volume by using digitized planimetry. Volumes of MR true-positive lesions were measured on T2-weighted images (VT2), on ADC maps (VADC), and on DCE images [VDCE]). VT2, VADC, VDCE and the greatest volume determined on images from any of the individual MR pulse sequences (Vmax) were compared with Vh (Bland-Altman analysis). Factors influencing MP MR imaging accuracy, or A, calculated as A = Vmax/Vh, were evaluated using generalized linear mixed models. RESULTS: For both readers, Vh was significantly underestimated with VT2 (P < .0001, both), VADC (P < .0001, both), and VDCE (P = .02 and P = .003, readers 1 and 2, respectively), but not with Vmax (P = .13 and P = .21, readers 1 and 2, respectively). Mean, 25th percentile, and 75th percentile, respectively, for Vmax accuracy were 0.92, 0.54, and 1.85 for reader 1 and 0.95, 0.57, and 1.77 for reader 2. At generalized linear mixed (multivariate) analysis, tumor Likert score (P < .0001), Gleason score (P = .009), and Vh (P < .0001) significantly influenced Vmax accuracy (both readers). This accuracy was good in tumors with a Gleason score of 7 or higher or a Likert score of 5, with a tendency toward underestimation of Vh; accuracy was poor in small (<0.5 cc) or low-grade (Gleason score ≤6) tumors, with a tendency toward overestimation of Vh. CONCLUSION: Vh can be estimated by using Vmax in aggressive tumors or in tumors with high Likert scores.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/patología , Anciano , Biomarcadores de Tumor/sangre , Errores Diagnósticos/estadística & datos numéricos , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Antígeno Prostático Específico/sangre , Prostatectomía , Neoplasias de la Próstata/cirugía , Carga Tumoral
4.
Diagn Interv Imaging ; 104(10): 465-476, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37345961

RESUMEN

PURPOSE: The purpose of this study was to develop and test across various scanners a zone-specific region-of-interest (ROI)-based computer-aided diagnosis system (CAD) aimed at characterizing, on MRI, International Society of Urological Pathology (ISUP) grade≥2 prostate cancers. MATERIALS AND METHODS: ROI-based quantitative models were selected in multi-vendor training (265 pre-prostatectomy MRIs) and pre-test (112 pre-biopsy MRIs) datasets. The best peripheral and transition zone models were combined and retrospectively assessed in internal (158 pre-biopsy MRIs) and external (104 pre-biopsy MRIs) test datasets. Two radiologists (R1/R2) retrospectively delineated the lesions targeted at biopsy in test datasets. The CAD area under the receiver operating characteristic curve (AUC) for characterizing ISUP≥2 cancers was compared to that of the Prostate Imaging-Reporting and Data System version2 (PI-RADSv2) score prospectively assigned to targeted lesions. RESULTS: The best models used the 25th apparent diffusion coefficient (ADC) percentile in transition zone and the 2nd ADC percentile and normalized wash-in rate in peripheral zone. The PI-RADSv2 AUCs were 82% (95% confidence interval [CI]: 74-87) and 86% (95% CI: 81-91) in the internal and external test datasets respectively. They were not different from the CAD AUCs obtained with R1 and R2 delineations, in the internal (82% [95% CI: 76-89], P = 0.95 and 85% [95% CI: 78-91], P = 0.55) and external (82% [95% CI: 74-91], P = 0.41 and 86% [95% CI:78-95], P = 0.98) test datasets. The CAD yielded sensitivities of 86-89% and 90-91%, and specificities of 64-65% and 69-75% in the internal and external test datasets respectively. CONCLUSION: The CAD performance for characterizing ISUP grade≥2 prostate cancers on MRI is not different from that of PI-RADSv2 score across two test datasets.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Masculino , Humanos , Próstata/patología , Neoplasias de la Próstata/patología , Estudios Retrospectivos , Imagen por Resonancia Magnética , Imagen de Difusión por Resonancia Magnética , Computadores
5.
Diagn Interv Imaging ; 103(11): 545-554, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35773099

RESUMEN

PURPOSE: The purpose of this study was to quantify the influence of factors of variability on apparent diffusion coefficient (ADC) estimation in the normal prostate peripheral zone (PZ). MATERIALS AND METHODS: Fifty healthy volunteers underwent in 2017 (n = 17) or 2020 (n = 33) two-point (0, 800 s/mm²) prostate diffusion-weighted imaging in the morning on 1.5 T scanners A and B from different manufacturers. Additional five-point (50, 150, 300, 500, 800 s/mm²) acquisitions were performed on scanner B in the morning and evening. ADC was measured in PZ at midgland using ADC maps reconstructed with various b-value combinations. ADC distributions from 2017 and 2020 were compared using Wilcoxon rank sum test. ADC obtained in the same volunteers were compared using Bland Altman methodology. The 95% confidence interval upper limit of the repeatability/reproducibility coefficient defined the lowest detectable ADC difference. RESULTS: Forty-nine participants with a mean age of 24.6 ± 3.8 [SD] years (range: 21-37 years) were finally included. ADC distributions from 2017 and 2020 were not significantly different and were combined. Despite high individual variability, there was no significant bias (10 × 10-6 mm²/s, P = 0.58) between ADC measurements made on both scanners. On scanner B, differences in lowest b-values chosen within the 0-500 s/mm² range for two-point ADC computation induced significant biases (56-109 × 10-6 mm²/s, P < 0.0001). ADC was significantly lower in the morning (bias: 33 × 10-6 mm²/s, P = 0.006). The number of b-values had little influence on ADC values. The lowest detectable ADC difference varied from 85 × 10-6 to 311 × 10-6 mm²/s across scanners, b-value combinations and periods of the day. CONCLUSIONS: The MRI scanner, the lowest b-value used and the period of the day induce substantial variability in ADC computation.


Asunto(s)
Próstata , Neoplasias de la Próstata , Masculino , Humanos , Adulto Joven , Adulto , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Voluntarios Sanos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda