Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Acta Anaesthesiol Scand ; 58(7): 826-34, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24773498

RESUMEN

BACKGROUND: Aortic stenosis is the most common valvular disease in developed countries, but it carries an increased mortality during non-cardiac surgery underscoring the importance of adequate hemodynamic management. Further, haemodynamic management of patients immediately after surgery for aortic stenosis can be challenging. Prediction of fluid responsiveness using dynamic variables has not been sufficiently studied in patients for aortic stenosis surgery. METHODS: Observational study evaluating fluid responsiveness on 32 (31 analysed) patients scheduled for aortic valve replacement due to aortic stenosis on mechanical ventilation before and after valve replacement. Increase in stroke volume (oesophagus Doppler) ≥ 15% to a fluid challenge defined fluid responders. RESULTS: Before surgery (31 fluid loads performed in 31 patients), areas under receiver operating characteristics curves (95% confidence intervals) were stroke volume variation (from arterial pulse contour analysis) 0.77 (0.58-0.90), pulse pressure variation 0.75 (0.54-0.90) and Pleth variability index 0.51 (0.31-0.69). After aortic valve replacement (31 fluid loads performed in 23 patients) the values were stroke volume variation 0.90 (0.74-0.98), pulse pressure variation 0.95 (0.80-1.0) and Pleth variability index 0.72 (0.52-0.87). CONCLUSIONS: The arterial pressure-based variables had moderate predictive values before valve replacement, but it predicted fluid responsiveness well postoperatively. Pleth variability index did not predict fluid responsiveness preoperatively, and it had a moderate predictive value postoperatively. These results indicate that arterial pressure-based dynamic variables have limited potential to guide fluid therapy in patients with aortic stenosis. Their ability to guide fluid therapy after aortic valve replacement seems better.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Fluidoterapia , Sustitutos del Plasma/farmacología , Volumen Sistólico/efectos de los fármacos , Anciano , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Área Bajo la Curva , Puente de Arteria Coronaria , Ecocardiografía Transesofágica , Espiración/efectos de los fármacos , Femenino , Hemodinámica/efectos de los fármacos , Humanos , Derivados de Hidroxietil Almidón/administración & dosificación , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/etiología , Hipertrofia Ventricular Izquierda/fisiopatología , Inhalación/efectos de los fármacos , Complicaciones Intraoperatorias/etiología , Complicaciones Intraoperatorias/prevención & control , Soluciones Isotónicas/administración & dosificación , Soluciones Isotónicas/farmacología , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Plasma , Sustitutos del Plasma/administración & dosificación , Curva ROC , Respiración Artificial , Volumen de Ventilación Pulmonar/efectos de los fármacos , Resultado del Tratamiento
2.
Acta Anaesthesiol Scand ; 56(6): 777-86, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22288953

RESUMEN

BACKGROUND: Few data exist on dynamic variables predicting fluid responsiveness during laparoscopic surgery. The aim of this study was to explore the effects of laparoscopy on four dynamic variables: respiratory variations in pulse pressure (ΔPP), stroke volume variation by Vigileo/FloTrac (SVV (Vigileo) ), pleth variability index (PVI) and respiratory variations in pulse oximetry plethysmography waveform amplitude (ΔPOP), and their relation to fluid challenges during laparoscopic surgery. METHODS: ΔPP, SVV (Vigileo) , PVI and ΔPOP were studied in 20 adult patients before and during pneumoperitoneum (10-12 mmHg). During ongoing laparoscopic surgery, relations between the dynamic variables and changes in stroke volume oesophageal Doppler, (SV(OD) ) after fluid challenges (250 ml colloid) were evaluated. RESULTS: Pneumoperitoneum changed the dynamic variables as follows {mean [95% confidence interval (CI)]}: ΔPP 0.5 (-1.3, 2.3)%, P = 0.53; SVV (Vigileo) 0.6 (-1.3, 2.5)%, P = 0.52; PVI 2.9 (0.4, 5.3)%, P = 0.025. For ΔPOP, median difference (95% CI) was 2.5 (-0.15, 6.7)%, P = 0.058. During laparoscopic surgery, areas under receiver operating characteristics curves (95% CI) were ΔPP 0.53 (0.31-0.75), SVV (Vigileo) 0.74 (0.51-0.90), PVI 0.61 (0.38-0.81), ΔPOP 0.63 (0.40-0.82). Correlation coefficients (P-values) between changes in dynamic variables and changes in SV(OD) were ΔPP r = -0.65, P = 0.009; SVV (Vigileo) r = -0.73, P = 0.002; PVI r = -0.22, P = 0.44; ΔPOP r = -0.32, P = 0.24. CONCLUSION: ΔPP and SVV (Vigileo) did not change as pneumoperitoneum was established, whereas PVI increased and ΔPOP tended to increase. All four dynamic variables predicted fluid responsiveness relatively poor during ongoing laparoscopic surgery. ΔPP and SVV (Vigileo) tracked changes in stroke volume induced by fluid challenges during ongoing laparascopic surgery, whereas ΔPOP and PVI did not.


Asunto(s)
Fluidoterapia/métodos , Laparoscopía/métodos , Neumoperitoneo Artificial/métodos , Adulto , Anestesia/métodos , Área Bajo la Curva , Presión Sanguínea/fisiología , Presión Venosa Central/fisiología , Femenino , Inclinación de Cabeza , Humanos , Masculino , Persona de Mediana Edad , Oximetría , Pletismografía , Curva ROC , Mecánica Respiratoria/fisiología , Tamaño de la Muestra , Procesamiento de Señales Asistido por Computador , Volumen Sistólico/fisiología
3.
Acta Anaesthesiol Scand ; 55(10): 1221-30, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22092127

RESUMEN

BACKGROUND: Respiratory variations in pulse pressure (ΔPP) predict fluid responsiveness during mechanical ventilation. Variations in pulse oximetry plethysmography amplitude (ΔPOP) are proposed as a non-invasive alternative. Large variations in ΔPOP and poor agreement between ΔPP and ΔPOP are found in intensive care unit patients. General anaesthesia is suggested to reduce variability of ΔPOP and improve agreement between the variables. We evaluated the variability of the agreement between and the diagnostic values of ΔPP and ΔPOP during ongoing open abdominal surgery. The variability of diagnostic methods in specific clinical conditions is important, as this reflects the stability over time during which clinical decisions are made. METHODS: Observational study during open abdominal surgery in general anaesthesia. ΔPP and ΔPOP were calculated semi-automatically from recording periods of approximately 5 min both before and after fluid challenges. Fluid responsiveness was evaluated by changes in stroke volume (oesophageal Doppler) after 250 ml colloid. RESULTS: Thirty-four fluid challenges were performed in 25 patients. Variance both within registration periods and between patients were significantly larger for ΔPOP than for ΔPP (54.1% vs. 22.1% and 69.6% vs. 22.6%, respectively, both P < 0.001). Limits of agreement with a regression-based correction were ± 13.9%. Areas under receiver operating characteristics curves for fluid responsiveness were 0.67 for ΔPP and 0.72 for ΔPOP. CONCLUSIONS: Analysis of raw signals during open abdominal surgery documents that the variance of ΔPOP is larger than of ΔPP, with wide limits of agreement between ΔPP and ΔPOP. The diagnostic values of ΔPP and ΔPOP are relatively poor.


Asunto(s)
Abdomen/cirugía , Presión Sanguínea/fisiología , Fotopletismografía/métodos , Anestesia General , Área Bajo la Curva , Presión Venosa Central/fisiología , Femenino , Fluidoterapia , Frecuencia Cardíaca/fisiología , Humanos , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Oximetría , Medicación Preanestésica , Curva ROC , Procesamiento de Señales Asistido por Computador , Volumen Sistólico/fisiología
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda