Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
Knee Surg Sports Traumatol Arthrosc ; 32(3): 693-703, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38415963

RESUMEN

PURPOSE: Assessing the risk of tibial baseplate loosening in patients after unrestricted kinematically aligned (unKA) total knee arthroplasty (TKA) using a medially conforming insert is important because baseplates generally are aligned in varus which has been linked to an increased incidence of aseptic loosening following mechanically aligned TKA. Two limits that indicate long-term stability in patients are a change in maximum total point motion between 1 and 2 years (ΔMTPM) < 0.2 mm and anterior tilt at 2 years < 0.8°. The purposes were to determine: (1) the number of patients with ΔMTPM > 0.2 mm, (2) the number of patients with anterior tilt > 0.8° and (3) whether increased varus baseplate and limb alignment were associated with increased migration. METHODS: Thirty-five patients underwent cemented, caliper-verified, unKA TKA using a medially conforming tibial insert with posterior cruciate ligament (PCL) retention. Biplanar radiographs acquired on the day of surgery and at 1.5, 3, 6, 12 and 24 months were processed with model-based radiostereometric analysis (RSA) software to determine migration and the number of patients with migration above the two stability limits. Medial proximal tibial angle (MPTA), hip-knee-ankle angle (HKAA) and posterior slope angle (PSA) were analyzed for an association with migration in six degrees of freedom and in MTPM. RESULTS: Thirty-two of 35 patients were available for analysis at 2 years. One patient exhibited ΔMTPM > 0.2 mm. The same patient exhibited anterior tilt > 0.8°. Varus rotation (p = 0.048, r ≤ 0.34) and medial translation (p = 0.0273, r ≤ 0.29) increased with increased varus baseplate alignment. CONCLUSION: The results indicate low risk of long-term baseplate loosening in patients. Although varus rotation and medial translation increased with increased varus baseplate alignment, the magnitudes of the migrations were minimal and did not increase ΔMTPM and anterior tilt. LEVEL OF EVIDENCE: Level II, therapeutic prospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Análisis Radioestereométrico , Prótesis de la Rodilla/efectos adversos , Fenómenos Biomecánicos , Estudios Prospectivos , Articulación de la Rodilla/cirugía , Tibia/cirugía , Osteoartritis de la Rodilla/cirugía
2.
J Arthroplasty ; 39(3): 695-700, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37659680

RESUMEN

BACKGROUND: The preceding study reported a 10-year follow-up of 222 kinematically aligned total knee arthroplasties (TKA) performed in 217 patients in 2007. As 35% of tibial components and 8% of limbs were in >3° varus, the present study assessed whether this adversely affected reoperation, implant survival, and function at 16 years. METHODS: We retrospectively reviewed a single surgeon's private practice database to determine the patients who underwent reoperation as well as Forgotten Joint Score and Oxford Knee Score. RESULTS: There were 7 patients who had a major reoperation (revision of a loose tibial component [n = 2], and revision of well-fixed component due to stiffness [n = 1], patella instability [n = 1], pain [n = 1], and infection [n = 2]). There were 5 who had a minor reoperation that retained the components, and 91 patients (94 TKAs) died. Implant survivorship was 93% using reoperation for any reason as the endpoint. The median (interquartile range) Forgotten Joint and Oxford Knee scores were 88 (57 to 100) and 45 (39 to 48) points, respectively. CONCLUSION: The kinematically aligned TKA had a 7% reoperation rate at 16 years follow-up, comparable to or lower than reports of mechanically aligned TKA, which supports the concept of the unrestricted version of kinematic alignment in which the patient's prearthritic alignment is fully restored regardless of deformity.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Reoperación , Articulación de la Rodilla/cirugía , Estudios Retrospectivos , Estudios de Seguimiento , Fenómenos Biomecánicos , Osteoartritis de la Rodilla/cirugía
3.
Instr Course Lect ; 72: 241-259, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36534860

RESUMEN

Peer-reviewed studies published up to May 2022 are used to provide a comprehensive understanding of unrestricted kinematically aligned total knee arthroplasty. The intent is to cultivate the curiosity of those interested in this method of personalized alignment. The rationale of unrestricted kinematic alignment is to set the femoral and tibial components coincident with the patient's prearthritic joint lines, restore the femoral and tibial phenotypes, and coalign the three kinematic axes of the components with those of the knee. The surgical technique, learning curve, and accuracy of performing kinematically aligned total knee arthroplasty with a caliper and company manufactured manual instrumentation should be explored and compared with robotic instrumentation. Kinematic alignment restores the native knee's medial and lateral tibial compartment forces, which mechanically aligned total knee arthroplasty cannot do even after ligament release. In addition, insert conformity plays a role in restoring native tibiofemoral kinematics. A literature review of clinical outcomes, long-term durability, and the risk of varus tibial component failure and patellofemoral instability shows unrestricted kinematic alignment has comparable if not superior results when compared with mechanical alignment.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Rango del Movimiento Articular , Articulación de la Rodilla/cirugía , Fémur/cirugía , Tibia/cirugía , Osteoartritis de la Rodilla/cirugía , Fenómenos Biomecánicos
4.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 852-860, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34921630

RESUMEN

PURPOSE: Excision of the posterior cruciate ligament (PCL) is recommended when implanting a medial pivot (MP) total knee arthroplasty (TKA) to reduce the risk of limiting flexion by over-tensioning the flexion space. The present study determined whether PCL retention (1) limits internal tibial rotation and (2) causes anterior lift-off of the insert in 90° flexion after implantation of an MP design with unrestricted caliper verified kinematic alignment (KA). METHODS: Four surgeons implanted an MP TKA design with medial ball-in-socket and lateral flat tibial insert in ten fresh-frozen cadaveric knees. Before and after PCL excision, trial inserts with medial goniometric markings measured the angular I-E tibial orientation relative to the trial femoral component's medial condyle in extension and at 90° flexion, and the surgeon recorded the occurrence of anterior lift-off of the insert at 90° flexion. RESULTS: PCL retention resulted in greater internal tibial rotation than PCL excision, with mean values of 15° vs 7° degrees from maximum extension to 90° flexion, respectively (p < 0.0007). At 90° flexion, no TKAs with PCL retention and one TKA with PCL excision had anterior lift-off of the insert (N.S.). CONCLUSIONS: This preliminary study of ten cadaveric knees showed that PCL retention restored more passive internal tibial rotation than PCL excision with a negligible risk of anterior lift-off. However, in vivo analysis from multiple authors with a larger sample size is required to recommend PCL retention with an MP TKA design implanted with unrestricted caliper verified KA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Ligamento Cruzado Posterior , Humanos , Ligamento Cruzado Posterior/cirugía , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Tibia/cirugía , Rango del Movimiento Articular , Cadáver
5.
Knee Surg Sports Traumatol Arthrosc ; 31(8): 3051-3060, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35641683

RESUMEN

PURPOSE: Because different targets are used for internal-external rotation, an asymmetric baseplate designed for mechanical alignment may lead to under-coverage and concomitant posterior rim loading in the lateral compartment following unrestricted kinematic alignment (KA) TKA. Recognizing that such loading can lead to premature wear and/or subsidence, our aim was to determine the cause(s) so that occurrence could be remedied. Our hypothesis was that baseplate design features such as asymmetric shape when aligned in KA would consistently contribute to posterior rim loading in the lateral compartment. METHODS: Based on analysis of fluoroscopic images of 50 patients performing dynamic, weight bearing deep knee bend and step up and of postoperative CT images, five possible causes were investigated. Causes included internal rotation of the baseplate when positioned in KA; posterior position of the lateral femoral condyle at extension; internal tibial rotation with flexion; internal rotational deviation of the baseplate from the KA rotation target; and posterior slope. RESULTS: The incidence of posterior rim loading was 18% (9 of 50 patients). When positioned in KA, the asymmetric baseplate left 15% versus 10% of the AP depth of the lateral compartment uncovered posteriorly for posterior rim loading and non-posterior rim loading groups, respectively (p = 0.009). The lateral femoral condyle at extension was more posterior by 4 mm for the posterior rim loading group (p = 0.003). CONCLUSIONS: Posterior rim loading in the lateral compartment was caused in part by the asymmetric design of the tibial baseplate designed for mechanical alignment which was internally rotated when positioned in KA thus under-covering a substantial percentage of the posterior lateral tibia. This highlights the need for new, asymmetric baseplates designed to maximize coverage when used in KA. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Fémur/cirugía , Tibia/diagnóstico por imagen , Tibia/cirugía , Rango del Movimiento Articular
6.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3627-3636, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34350484

RESUMEN

PURPOSE: Tibial insert conformity in total knee arthroplasty (TKA) is of interest due to the potential effect on tibiofemoral kinematics. This study determined differences in anterior-posterior movements of the femoral condyles, pivot locations, and internal tibial rotation in different arcs of flexion for two implants with different insert conformities in kinematically aligned TKA. METHODS: Twenty-five patients treated with a medial and lateral low-conforming, posterior cruciate ligament (PCL) retaining (LC CR) implant followed by a medial ball-in-socket and flat, lateral PCL sacrificing (B-in-S CS) implant in the contralateral knee underwent single-plane fluoroscopy during a deep knee bend. Analysis following 3D-to-2D image registration determined tibiofemoral kinematics and patients completed validated outcome scores for both knees. RESULTS: The mean follow-up of 1.6 ± 0.4 years for the knee with the B-in-S CS implant was shorter than the 2.7 ± 1.2 years for the LC CR implant. From 0º to 30º of flexion, a medial pivot occurred with the tibia rotating internally approximately 5º with both implants. From 30º to 90º, the pivot remained medial and internal rotation increased to 10º with the B-in-S CS implant. In contrast, neither femoral condyle moved more than 1 mm with the LC CR implant from 30º to 60º, but from 60º to 90º degrees, a lateral pivot occurred and internal rotation increased. Internal rotation of the tibia on the femur from 0° to maximum flexion occurred about a medial pivot similar to the native knee for the B-in-S CS implant and was 4.5° greater than that of the LC CR implant (10.4° vs 5.9°). There was no difference in the median patient-reported outcome scores between implant designs. CONCLUSIONS: Tibial insert conformity is a primary determinant of a medial or lateral pivot during a deep knee bend. One explanation for the transition from a medial to lateral pivot between 30º and 60º with the LC CR implant is the chock-block effect of the insert's posterolateral upslope which impedes posterior movement of the lateral femoral condyle. Because there is no posterolateral upslope in the insert of the B-in-S CS implant, the tibia pivots medially throughout flexion similar to the native knee. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Rodilla , Rodilla/cirugía , Ejercicio Físico , Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Fémur , Rango del Movimiento Articular , Tibia , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años
7.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1433-1442, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36201009

RESUMEN

PURPOSE: Varus alignment of the tibial baseplate and limb > 3° might adversely affect baseplate fixation after total knee arthroplasty (TKA), especially for unrestricted kinematically aligned (KA) TKA which aligns a majority of baseplates in varus. The purposes of this study were to determine whether baseplate migration at 1 year (1) was significantly less than a stability limit of 0.5 mm, (2) increased over time, and (3) was related to varus alignment of the baseplate and limb after unrestricted KA TKA. METHODS: Thirty-five patients underwent unrestricted KA TKA using a fixed-bearing, cemented, medial conforming tibial insert with posterior cruciate ligament retention. Using model-based radiostereometric analysis, maximum total point motion (MTPM) (i.e., largest displacement on the baseplate) was computed at 6 weeks, 3 months, 6 months, and 1 year postoperatively relative to the day of surgery. Baseplate and limb alignment were measured postoperatively on long-leg CT scanograms. RESULTS: At 1 year, mean MTPM of 0.35 mm was significantly less than the 0.5 mm stability limit (p = 0.0002). Mean MTPM did not increase from 6 weeks to 1 year (p = 0.3047). Notably, 89% (31/35) of tibial baseplates and 46% (16/35) of limbs were > 3° varus. Baseplate and limb alignment had no relationship to MTPM at 1 year (|r|≤ 0.173, p ≥ 0.3276). CONCLUSION: Low and non-progressive tibial baseplate migration 1 year after unrestricted KA TKA with a medial conforming design should allay any concern that unrestricted KA TKA increases risk of baseplate loosening due to varus alignment of the baseplate and limb. LEVEL OF EVIDENCE: Level II, therapeutic prospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Estudios Prospectivos , Tibia/cirugía , Fenómenos Biomecánicos , Osteoartritis de la Rodilla/cirugía
8.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5438-5445, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37792084

RESUMEN

PURPOSE: The primary aim was to analyze unrestricted kinematic alignment (unKA) total knee arthroplasty (TKA) and determine the frequency of medial deviation of the prosthetic trochlear angle (PTA) of the femoral component relative to the quadriceps vector (QV) that terminates at the anterior inferior iliac spine (AIIS), and whether patients with medial deviation had a worse Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) relative to those with lateral deviation. The secondary aim was to determine the frequency of medial deviation for mechanical alignment (MA) TKA simulations. METHODS: From a database of a single surgeon, the study extracted de-identified data on 147 patients with a CT scanogram showing the pelvis and AIIS, a limb with an unKA TKA, and a native (i.e., healthy) opposite limb. On the scanogram, an examiner, blinded to the PROMs, measured the PTA-QV angle on the unKA TKA and on the opposite limb simulated MA TKA by drawing the PTA at 6° valgus relative to the femoral mechanical axis and measuring the PTA-QV angle. RESULTS: Medial deviation of the PTA occurred in 86% of patients with unKA TKA, and the 126 with medial deviation had a 17/1 point worse median FJS/OKS than the 21 with lateral deviation at a mean follow-up of 47 ± 8 months, respectively (p < 0.0001, p = 0.0053). In addition, 21%, 17%, and 8% of MA TKA had medial deviation after radiographic simulation using reported surgical errors for manual, patient-specific, and robotic instrumentation, respectively. CONCLUSION: In most patients with unKA TKA and a smaller proportion with MA TKA, a PTA of 6° valgus was medial to the QV, which, by excluding the patient's Q-angle, might alter patellofemoral kinematics like an incorrectly oriented trochleoplasty. The 17-point worse FJS in the patients with an unKA TKA and medial deviation of the PTA suggests the surgical target should be to orient the PTA lateral to the QV. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Fémur/cirugía , Tomografía Computarizada por Rayos X , Músculo Cuádriceps/diagnóstico por imagen , Músculo Cuádriceps/cirugía , Fenómenos Biomecánicos , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía
9.
J Arthroplasty ; 38(12): 2612-2617, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37321516

RESUMEN

BACKGROUND: There are no reports as to whether the condition of the anterior cruciate ligament (ACL) adversely affects the 2 to 3 year function and reoperation risk of a kinematically aligned (KA) total knee arthroplasty (TKA) performed with posterior cruciate ligament (PCL) retention and an intermediate medial conforming (MC) insert. METHODS: A single surgeon's prospective database query identified 418 consecutive primary TKAs performed between January 2019 and December 2019. The surgeon recorded the ACL condition in the operative note. Patients filled out the Forgotten Joint Score (FJS), Oxford knee score (OKS), and Knee Injury and Osteoarthritis Outcome Scores for Joint Replacement at the final follow-up. There were 299 patients with an intact ACL, 99 with a torn ACL, and 20 with a reconstructed ACL. The mean follow-up was 31 months (range, 20 to 45). RESULTS: The median FJS, OKS, and Knee Injury and Osteoarthritis Outcome Score (KOOS) of the reconstructed/torn/intact KA TKAs were 90/79/67, 47/44/43, and 92/88/80 points, respectively. The median OKS and KOOS of the reconstructed ACL cohort were 4 and 11 points higher than in the intact ACL cohort (P = .003, .04). One patient who had a reconstructed ACL underwent manipulation under anesthesia (MUA) for stiffness. The 5 reoperations in the intact ACL cohort were for instability (n = 2), revision after failed MUA for stiffness (n = 2), and infection (n = 1). CONCLUSION: These results suggest that patients who have a torn and reconstructed ACL can expect high function and a low risk of reoperation comparable to patients who have an intact ACL when treated with unrestricted, caliper-verified KA, PCL retention, and an intermediate MC insert.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Artroplastia de Reemplazo de Rodilla , Traumatismos de la Rodilla , Osteoartritis de la Rodilla , Osteoartritis , Humanos , Ligamento Cruzado Anterior/cirugía , Artroplastia de Reemplazo de Rodilla/efectos adversos , Articulación de la Rodilla/cirugía , Reoperación/efectos adversos , Incidencia , Lesiones del Ligamento Cruzado Anterior/complicaciones , Reconstrucción del Ligamento Cruzado Anterior/efectos adversos , Traumatismos de la Rodilla/cirugía , Osteoartritis/cirugía , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/etiología
10.
Int Orthop ; 47(7): 1737-1746, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37195465

RESUMEN

PURPOSE: For a new tibial insert design with ball-in-socket (B-in-S) medial conformity (MC), posterior cruciate ligament (PCL) retention, and flat lateral articular surface (B-in-S MC + PCL), this study determined whether internal tibial rotation and knee flexion were limited and clinical outcome scores were lower during weight-bearing activities relative to an insert with intermediate (I) (i.e., less than ball-in-socket) medial conformity (I MC + PCL). METHODS: Twenty-five patients were treated with bilateral unrestricted, caliper-verified kinematic alignment (KA) total knee arthroplasty (TKA) with an I MC + PCL insert and B-in-S MC + PCL insert in opposite knees. Each patient performed weight-bearing deep knee bend, step up, and chair rise under single-plane fluoroscopy. Analysis following 3D model-to-2D image registration determined internal tibial rotation. For each TKA, knee flexion was measured and patients completed clinical outcome scoring questionnaires. RESULTS: Internal tibial rotation did not differ between conformities during chair rise and step up (p = 0.3419 and 0.1030, respectively). During deep knee bend, internal tibial rotation between 90° and maximum flexion was 3° greater in the B-in-S MC + PCL group (18° vs 15°) (p = 0.0290). Mean knee flexion (p = 0.3115) and median Forgotten Joint Score (FJS), Oxford Knee Score (OKS), and Western Ontario and McMasters Universities Arthritis Index (WOMAC) scores (p = 0.2100, 0.2154, and 0.4542, respectively) did not differ between conformities. CONCLUSION: An insert with ball-in-socket medial conformity, which maximizes anteroposterior (AP) stability, did not limit internal tibial rotation and knee flexion and did not lower patient-reported outcomes when implanted with unrestricted caliper-verified KA and PCL retention. The high AP stability provided by the medial ball-in-socket might interest those surgeons exploring the treatment of the active patient with a desire to return to high-level and athletic activities.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Ligamento Cruzado Posterior , Humanos , Ligamento Cruzado Posterior/cirugía , Artroplastia de Reemplazo de Rodilla/métodos , Rotación , Articulación de la Rodilla/cirugía , Tibia/cirugía , Rango del Movimiento Articular , Fenómenos Biomecánicos
11.
Knee Surg Sports Traumatol Arthrosc ; 30(9): 2966-2974, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35366075

RESUMEN

PURPOSE: Surgeons performing total knee arthroplasty (TKA) are interested in the accuracy and time it takes to make the four femoral resections that determine the setting of the femoral component. A method for quantifying the error of each resection is the thickness, measured by a caliper, minus the femoral target. The present study tested the hypothesis that the mean deviation of the resection from the femoral target, the percentage of resections with a deviation of ± 0.5, 1.0, 1.5, and 2.0 mm, and the time to complete the femoral cuts were not different between experienced (E) and less-experienced (LE) surgeons performing unrestricted caliper verified kinematically aligned (KA) TKA with manual instruments. METHODS: This study analyzed intraoperative verification worksheets from 203 patients treated by ten E surgeons and 58 patients treated by four LE surgeons. The worksheet recorded (1) the thickness of the femoral target for the distal medial (DM), distal lateral (DL), posterior medial (PM), and posterior lateral (PL) resections and the caliper thickness of the resections with a resolution of 0.5 mm, and (2) the time to complete them. The most accurate resection has a mean difference ± standard deviation of 0 ± 0.0 mm. RESULTS: The accuracy of the 1044 initial resections (261 patients) was significantly closer to the femoral target for E vs. the LE surgeons: 0.0 ± 0.4 vs. - 0.3 ± 0.5 for the DM, 0.0 ± 0.5 vs. - 0.4 ± 0.6 for the DL, - 0.1 ± 0.5 vs. - 0.2 ± 0.5 PM, and - 0.1 ± 0.5 vs. - 0.4 ± 0.6 for the PL resections (p ≤ 0.0248). E surgeons completed the femoral resections in 12 min; 5 min faster than LE surgeons (p < 0.0001). CONCLUSIONS: Because the mean difference in femoral resections with manual instruments for E vs. LE surgeons was < 0.5 mm which is within the caliper's resolution, differences in accuracy were not clinically relevant. Surgeons exploring other alignment options and robotic, navigation, and patient-specific instrumentation might find these values helpful when deciding to change. LEVEL OF EVIDENCE: III; case-control study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Cirujanos , Fenómenos Biomecánicos , Estudios de Casos y Controles , Fémur , Humanos , Articulación de la Rodilla
12.
Knee Surg Sports Traumatol Arthrosc ; 30(3): 948-957, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33582829

RESUMEN

PURPOSE: The present study determined the postoperative phenotypes after unrestricted calipered kinematically aligned (KA) total knee arthroplasty (TKA), whether any phenotypes were associated with reoperation, implant revision, and lower outcome scores at 4 years, and whether the proportion of TKAs within each phenotype was comparable to those of the nonarthritic contralateral limb. METHODS: From 1117 consecutive primary TKAs treated by one surgeon with unrestricted calipered KA, an observer identified all patients (N = 198) that otherwise had normal paired femora and tibiae on a long-leg CT scanogram. In both legs, the distal femur-mechanical axis angle (FMA), proximal tibia-mechanical axis angle (TMA), and the hip-knee-ankle angle (HKA) were measured. Each alignment angle was assigned to one of Hirschmann's five FMA, five TMA, and seven HKA phenotype categories. RESULTS: Three TKAs (1.5%) underwent reoperation for anterior knee pain or patellofemoral instability in the subgroup of patients with the more valgus phenotypes. There were no implant revisions for component loosening, wear, or tibiofemoral instability. The median Forgotten Joint Score (FJS) was similar between phenotypes. The median Oxford Knee Score (OKS) was similar between the TMA and HKA phenotypes and greatest in the most varus FMA phenotype. The phenotype proportions after calipered KA TKA were comparable to the contralateral leg. CONCLUSION: Unrestricted calipered KA's restoration of the wide range of phenotypes did not result in implant revision or poor FJS and OKS scores at a mean follow-up of 4 years. The few reoperated patients had a more valgus setting of the prosthetic trochlea than recommended for mechanical alignment. Designing a femoral component specifically for KA that restores patellofemoral kinematics with all phenotypes, especially the more valgus ones, is a strategy for reducing reoperation risk. LEVEL OF EVIDENCE: Therapeutic, Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Fenotipo , Reoperación , Estudios Retrospectivos
13.
Knee Surg Sports Traumatol Arthrosc ; 29(2): 437-445, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32239272

RESUMEN

PURPOSE: Surgeons performing total knee arthroplasty (TKA) on the osteoarthritic valgus deformity often use a posterior stabilized (PS) and semi-constrained implants to substitute for the release of a contracted posterior cruciate ligament (PCL) instead of a cruciate retaining (CR) implant. Calipered kinematic alignment (KA) strives to retain the PCL and use a CR implant. The aim of this study of the windswept deformity was to determine whether the level of implant constraint, outcome scores, and alignment after bilateral calipered KA TKA are different between a pair of knees with a varus and valgus deformity in the same patient. METHODS: A review of a prospectively collected database identified all patients with a windswept deformity treated with bilateral TKA (n = 19) out of 2430 consecutive primary TKAs performed between 2014 and 2019. Operative reports determined the level of implant constraint. Patient response to the Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) assessed outcomes at a mean follow-up of 2.3 years. Postoperative alignment was measured on an A-P computer tomographic scanogram of the limb. RESULTS: CR implants were used in 15 of 19 (79%) valgus deformities and 17 of 19 (89%) of varus deformities (n.s.). No knees required a semi-constrained implant. There was no difference in the median postoperative FJS and OKS (n.s.), and a 1° or less difference in the mean postoperative distal lateral femoral angle (p = 0.005) and proximal medial tibial angle (n.s.) between the paired varus and valgus knee deformity. CONCLUSION: Based on this small series, surgeons that use calipered KA TKA can expect to use CR implants in most patients with windswept deformity and achieve comparable outcome scores and alignment between the paired varus and valgus deformity. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Rodilla/anomalías , Osteoartritis de la Rodilla/cirugía , Anciano , Fenómenos Biomecánicos , Fijadores Externos , Femenino , Fémur/fisiopatología , Humanos , Rodilla/fisiopatología , Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Rango del Movimiento Articular , Estudios Retrospectivos , Tibia/fisiopatología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
14.
Arch Orthop Trauma Surg ; 141(12): 2287-2294, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34264381

RESUMEN

INTRODUCTION: In total knee arthroplasty (TKA), the level of conformity, a medial stabilized (MS) implant, needs to restore native (i.e., healthy) knee kinematics without over-tensioning the flexion space when the surgeon chooses to retain the posterior cruciate ligament (PCL) is unknown. Whether an insert with a medial ball-in-socket conformity and lateral flat surface like the native knee or a less than spherical medial conformity restores higher and closer to native internal tibial rotation without anterior lift-off, an over-tension indicator, when implanted with calipered kinematic alignment (KA), is unknown. METHODS AND MATERIALS: Two surgeons treated 21 patients with calipered KA and a PCL retaining MS implant. Validated verification checks that restore native tibial compartment forces in passive flexion without release of healthy ligaments were used to select the optimal insert thickness. A goniometer etched onto trial inserts with the ball-in-socket and the less than spherical medial conformity measured the tibial rotation relative to the femoral component at extension and 90° and 120° flexion. The surgeon recorded the incidence of anterior lift-off of the insert. RESULTS: The insert with the medial ball-in-socket and lateral flat surface restored more internal tibial rotation than the one with less than spherical medial conformity, with mean values of 19° vs. 17° from extension to 90° flexion (p < 0.01), and 23° vs. 20°-120° flexion (p < 0.002), respectively. There was no anterior lift-off of the insert at 90° and 120° flexion. CONCLUSION: An MS insert with a medial ball-in-socket and lateral flat surface that matches the native knee's spherical conformity restores native tibial internal rotation when implanted with calipered KA and PCL retention without over-tensioning the flexion space.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/cirugía , Rango del Movimiento Articular , Tibia/cirugía
15.
Knee Surg Sports Traumatol Arthrosc ; 28(10): 3118-3127, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31768572

RESUMEN

PURPOSE: Kinematically aligned total knee arthroplasty (KA TKA) strives to restore the native distal and posterior joint lines of the femur. Because the joint lines of a virtually planned femoral component on the native femur can serve as surrogates of those of the native femur, the present study determined position and orientation deviations of the femoral joint lines following calipered KA TKA from virtually planned joint lines and whether these alignment deviations affect clinical outcomes. Our hypotheses were that the alignment deviations for most knees would be less than 2 mm and/or 2° and that larger alignment deviations would not be associated with lower clinical outcome scores. METHODS: A review of lower extremity CT scanograms and CT scans of the knee identified 36 patients treated with calipered KA TKA in one limb and no other skeletal deformities in either limb. 3D models of the operated femur with the implanted femoral component and the native femur were created. The articular surfaces of a 3D model of the implanted femoral component in the TKA knee were shape-matched to the condyles of the native femur to create a virtual plan. The shape-matched femoral component served as a reference from which to determine alignment deviations of the femoral component implanted in the ipsilateral femur. The Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) were obtained at an average of 20 months. RESULTS: For proximal-distal and anterior-posterior positions and varus-valgus and internal-external orientations of the femoral component, the root mean square deviations from the planned joint lines ranged from 1.4 to 1.5 (mm or degrees). The mean differences ranged from - 0.1 to 0.2 (mm or degrees) indicating an absence of systematic alignment deviations. The proportion of knees with joint lines within ± 2 mm and ± 2° of the joint lines of virtually planned knees ranged from 83 to 92%. For the FJS and OKS, the median values were 79 (out of 100) and 45 (out of 48), respectively, and there were no significant correlations between deviations in the positions and orientations and either the FJS or the OKS. CONCLUSION: Alignment deviations were bounded by 2 mm and 2° for most knees, which previous biomechanical studies have shown reduce the risks of stiffness, loss of extension, loss of flexion, and tibial compartment forces higher than those of the native knee. Moreover, because median FJS and OKS were relatively high, and because larger alignment deviations did not correlate with lower outcome scores, deviations did not affect clinical outcomes. These results validate calipered KA TKA as a surgical technique which closely restores the distal and posterior femoral joint lines to those planned and achieves concomitant high patient-reported outcome scores. Thus, surgeons can use the calipered KA TKA technique with confidence that the surgical alignment goal will be satisfied with sufficient accuracy that high patient-reported outcomes are achieved. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Fémur/cirugía , Articulación de la Rodilla/cirugía , Anciano , Fenómenos Biomecánicos , Femenino , Fémur/diagnóstico por imagen , Humanos , Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Rango del Movimiento Articular , Estudios Retrospectivos , Tibia/cirugía , Tomografía Computarizada por Rayos X
16.
Knee Surg Sports Traumatol Arthrosc ; 28(9): 2893-2904, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31410525

RESUMEN

PURPOSE: Kinematically aligned (KA) TKA strives to restore native limb and knee alignments without ligament release with the premise that knee function likewise will be closely restored to native to the extent enabled by the components used. This study determined differences in anterior-posterior (AP) tibial contact locations of a KA TKA performed with asymmetric, fixed bearing, posterior cruciate-retaining (PCR) components from those of the native contralateral knee and also determined the incidence of posterior rim contact of the tibial insert during a deep knee bend and a step-up. METHODS: Both knees were imaged using single-plane fluoroscopy for 25 patients with a calipered KA TKA and a native knee in the contralateral limb. AP tibial contact locations in each compartment were determined following 3D model-to-2D image registration. Differences in mean AP tibial contact locations in each compartment between the KA TKA knees and the native contralateral knees were analysed. Contact locations either on or beyond the most posterior point of the tibial insert determined the occurrence of posterior rim contact. RESULTS: Mean AP tibial contact locations for both native and KA TKA knees remained relatively centred in the medial compartment but moved posterior in the lateral compartment during flexion. In both the medial and lateral compartments, differences in mean AP tibial contact locations between the KA TKA knees and the native contralateral knees were more posterior and greatest at 0° flexion for both activities (4 mm, p = 0.0009 and 7 mm, p < 0.0001 for deep knee bend and 6 mm, p < 0.0001 and 8 mm, p < 0.0001 for step-up in the medial and lateral compartments, respectively). The incidence of posterior rim contact of the tibial insert was 16% (4 of 25 patients) but the lowest Oxford Knee Score was 43 for these patients. The median Oxford Knee Score for all patients was 46 (out of 48). CONCLUSIONS: Calipered KA TKA with asymmetric, fixed bearing, PCR components resulted in mean AP tibial contact locations which were relatively centred in the compartments and differed at most from those of the native contralateral knee by approximately 15% of the AP dimension of a mid-sized tibial baseplate. Although posterior rim contact occurred in some patients, all such patients had high patient-reported outcome scores. LEVEL OF EVIDENCE: Therapeutic, Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Inestabilidad de la Articulación/prevención & control , Articulación de la Rodilla/fisiología , Prótesis de la Rodilla , Rango del Movimiento Articular , Tibia/fisiología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente
17.
Clin Orthop Relat Res ; 477(5): 1200-1207, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30531423

RESUMEN

BACKGROUND: Four mechanical alignment force targets are used to predict early patient-reported outcomes and/or to indicate a balanced TKA. For surgeons who use kinematic alignment, there are no reported force targets. To date the usefulness of these mechanical alignment force targets with kinematic alignment has not been reported nor has a specific force target for kinematic alignment been identified. QUESTIONS/PURPOSES: (1) Does hitting one of four mechanical alignment force targets proposed by Gustke, Jacobs, Meere, and Menghini determine whether a patient with a kinematically aligned TKA had better patient-reported Oxford Knee and WOMAC scores at 6 months? (2) Can a new force target be identified for kinematic alignment that determines whether the patient had a good/excellent Oxford Knee Score of ≥ 34 points (48 best, 0 worst)? METHODS: Between July 2017 and November 2017, we performed 148 consecutive primary TKAs of which all were treated with kinematic alignment using 10 caliper measurements and verification checks. A total of 68 of the 148 (46%) TKAs performed during the study period had intraoperative measurements of medial and lateral tibial compartment forces during passive motion with an instrumented tibial insert and were evaluated in this retrospective study. Because the surgeon and surgical team were blinded from the display showing the compartment forces, there was no attempt to hit a mechanical alignment force target when balancing the knee. The Oxford Knee Score and WOMAC score measured patient-reported outcomes at 6 months postoperatively. For each mechanical alignment force target, a Wilcoxon rank-sum test determined whether patients who hit the target had better outcome scores than those who missed. An area under the curve (AUC) analysis tried to identify a new force target for kinematic alignment at full extension and 10°, 30°, 45°, 60°, 75°, and 90° of flexion that predicted whether patients had a good/excellent Oxford Knee Score, defined as a score of ≥ 34 points. RESULTS: Patients who hit or missed each of the four mechanical alignment force targets did not have higher or lower Oxford Knee Scores and WOMAC scores at 6 months. Using the Gustke force target as a representative example, the Oxford Knee Score of 41 ± 6 and WOMAC score of 13 ± 11 for the 31 patients who hit the target were not different from the Oxford Knee Score of 39 ± 8 (p = 0.436) and WOMAC score of 17 ± 17 (p = 0.463) for the 37 patients who missed the target. The low observed AUCs (from 0.56 to 0.58) at each of these flexion angles failed to identify a new kinematic alignment force target associated with a good/excellent (≥ 34) Oxford Knee Score. CONCLUSIONS: Tibial compartment forces comparable to those reported for the native knee and insufficient sensitivity of the Oxford Knee and WOMAC scores might explain why mechanical alignment force targets were not useful and a force target was not identified for kinematic alignment. Intraoperative sensors may allow surgeons to measure forces very precisely in the operating room, but that level of precision is not called for to achieve a good/excellent result after calipered kinematically aligned TKA, and so its use may simply add expense and time but does not improve the results from the patient's viewpoint. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Resultado del Tratamiento
19.
J Biomech Eng ; 2018 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-30029259

RESUMEN

BACKGROUND: The OrthoSensor VERASENSE knee system is a commercially available instrumented tibial insert that provides real-time intraoperative measurements of tibial contact force and contact location to guide surgeons toward improving outcomes in total knee arthroplasty (TKA). However, the device has been used contrary to the manufacturer's recommendations in several studies and lacks published accuracy data. Therefore, the primary objectives of this study were to evaluate the device's error in tibial contact force when used according to and contrary to the manufacturer's recommendations, and also to evaluate the device's error in anterior-posterior (A-P) and medial-lateral (M-L) contact locations. METHODS: The error in tibial contact force in single compartment distributed loading was evaluated by applying known forces in ranges within and exceeding that recommended by the manufacturer, with rezeroing as recommended by the manufacturer, and without rezeroing. The error in tibial contact location in single compartment concentrated loading was evaluated by applying known forces at known locations on the articular surface. RESULTS: Exceeding the maximum allowable load and not rezeroing did not adversely affect the bias (i.e. average error) (p > 0.05). The maximum absolute bias without rezeroing was 2.9 lbf. Rezeroing more than doubled the bias. The maximum root mean squared error in tibial contact location was 1.5 mm in the A-P direction. CONCLUSION: The device measures tibial contact force with comparable error well above the maximum allowable load and without rezeroing, contrary to the manufacturer's instructions.

20.
Knee Surg Sports Traumatol Arthrosc ; 26(6): 1589-1601, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28884312

RESUMEN

PURPOSE: Following total knee arthroplasty (TKA), high tibial forces, large differences in tibial forces between the medial and lateral compartments, and anterior translation of the contact locations of the femoral component on the tibial component during passive flexion indicate abnormal knee function. Because the goal of kinematically aligned TKA is to restore native knee function without soft tissue release, the objectives were to determine how well kinematically aligned TKA limits high tibial forces, differences in tibial forces between compartments, and anterior translation of the contact locations of the femoral component on the tibial component during passive flexion. METHODS: Using cruciate retaining components, kinematically aligned TKA was performed on thirteen human cadaveric knee specimens with use of manual instruments without soft tissue release. The tibial forces and tibial contact locations were measured in both the medial and lateral compartments from 0° to 120° of passive flexion using a custom tibial force sensor. RESULTS: The average total tibial force (i.e. sum of medial + lateral) ranged from 5 to 116 N. The only significant average differences in tibial force between compartments occurred at 0° of flexion (29 N, p = 0.0008). The contact locations in both compartments translated posteriorly in all thirteen kinematically aligned TKAs by an average of 14 mm (p < 0.0001) and 18 mm (p < 0.0001) in the medial and lateral compartments, respectively, from 0° to 120° of flexion. CONCLUSIONS: After kinematically aligned TKA, average total tibial forces due to the soft tissue restraints were limited to 116 N, average differences in tibial forces between compartments were limited to 29 N, and a net posterior translation of the tibial contact locations was observed in all kinematically aligned TKAs during passive flexion from 0° to 120°, which are similar to what has been measured previously in native knees. While confirmation in vivo is warranted, these findings give surgeons who perform kinematically aligned TKA confidence that the alignment method and surgical technique limit high tibial forces, differences in tibial forces between compartments, and anterior translation of the tibial contact locations during passive flexion.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/fisiopatología , Tibia/fisiopatología , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fenómenos Biomecánicos , Desviación Ósea/etiología , Desviación Ósea/fisiopatología , Desviación Ósea/prevención & control , Cadáver , Humanos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Persona de Mediana Edad , Rango del Movimiento Articular , Tibia/cirugía
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda