Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
Neuroradiology ; 66(6): 907-917, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38607437

RESUMEN

PURPOSE: This study aimed to compare the radiological tumor (T)-category using multiparametric MRI with the pathological T category in patients with oral tongue squamous cell carcinoma (OTSCC) and to examine which is a better predictor of prognosis. METHODS: This retrospective study included 110 consecutive patients with surgically resected primary OTSCC who underwent preoperative contrast-enhanced MRI. T categories determined by maximum diameter and depth of invasion were retrospectively assessed based on the pathological specimen and multiparametric MRI. The MRI assessment included the axial and coronal T1-weighted image (T1WI), axial T2-weighted image (T2WI), coronal fat-suppressed T2WI, and axial and coronal fat-suppressed contrast-enhanced T1WI (CET1WI). Axial and coronal CET1WI measurements were divided into two groups: measurements excluding peritumoral enhancement (MEP) and measurements including peritumoral enhancement. The prognostic values for recurrence and disease-specific survival after radiological and pathological T categorization of cases into T1/T2 and T3/T4 groups were compared. RESULTS: The T category of MEP on coronal CET1WI was the most relevant prognostic factor for recurrence [hazard ratio (HR) = 3.30, p = 0.001] and the HR was higher than the HR for pathological assessment (HR = 2.26, p = 0.026). The T category determined by MEP on coronal CET1WI was also the most relevant prognostic factor for disease-specific survival (HR = 3.12, p = 0.03), and the HR was higher than the HR for pathological assessment (HR = 2.02, p = 0.20). CONCLUSION: The T category determined by MEP on the coronal CET1WI was the best prognostic factor among all radiological and pathological T category measurements.


Asunto(s)
Carcinoma de Células Escamosas , Medios de Contraste , Imagen por Resonancia Magnética , Neoplasias de la Lengua , Humanos , Neoplasias de la Lengua/diagnóstico por imagen , Neoplasias de la Lengua/patología , Masculino , Femenino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Anciano , Imagen por Resonancia Magnética/métodos , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Adulto , Estadificación de Neoplasias , Anciano de 80 o más Años , Recurrencia Local de Neoplasia/diagnóstico por imagen , Tasa de Supervivencia , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Invasividad Neoplásica
2.
Radiol Med ; 129(5): 677-686, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38512626

RESUMEN

PURPOSE: To compare the diagnostic performance of 40 keV and 70 keV virtual monoenergetic images (VMIs) generated from dual-energy CT in the detection of pancreatic cancer. METHODS: This retrospective study included patients who underwent pancreatic protocol dual-energy CT from January 2019 to August 2022. Four radiologists (1-11 years of experience), who were blinded to the final diagnosis, independently and randomly interpreted 40 keV and 70 keV VMIs and graded the presence or absence of pancreatic cancer. For each image set (40 keV and 70 keV VMIs), the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated. The diagnostic performance of each image set was compared using generalized estimating equations. RESULTS: Overall, 137 patients (median age, 71 years; interquartile range, 63-78 years; 77 men) were included. Among them, 62 patients (45%) had pathologically proven pancreatic cancer. The 40 keV VMIs had higher specificity (75% vs. 67%; P < .001), PPV (76% vs. 71%; P < .001), and accuracy (85% vs. 81%; P = .001) than the 70 keV VMIs. On the contrary, 40 keV VMIs had lower sensitivity (96% vs. 98%; P = .02) and NPV (96% vs. 98%; P = .004) than 70 keV VMIs. However, the diagnostic confidence in patients with (P < .001) and without (P = .001) pancreatic cancer was improved in 40 keV VMIs than in 70 keV VMIs. CONCLUSIONS: The 40 keV VMIs showed better diagnostic performance in diagnosing pancreatic cancer than the 70 keV VMIs, along with higher reader confidence.


Asunto(s)
Neoplasias Pancreáticas , Imagen Radiográfica por Emisión de Doble Fotón , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Tomografía Computarizada por Rayos X/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Valor Predictivo de las Pruebas
3.
Eur Radiol ; 33(5): 3165-3171, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36814031

RESUMEN

OBJECTIVES: To evaluate the feasibility and image quality of intranodal dynamic contrast-enhanced CT lymphangiography (DCCTL) and dynamic contrast-enhanced MR lymphangiography (DCMRL) in microminipigs. METHODS: Our institution's committee for animal research and welfare provided approval. Three microminipigs underwent DCCTL and DCMRL after inguinal lymph node injection of 0.1 mL/kg contrast media. Mean CT values on DCCTL and signal intensity (SI) on DCMRL were measured at the venous angle and thoracic duct (TD). The contrast enhancement index (CEI; increase in CT values pre- to post-contrast) and signal intensity ratio (SIR; SI of lymph divided by SI of muscle) were evaluated. The morphologic legibility, visibility, and continuity of lymphatics were qualitatively evaluated using a 4-point scale. Two microminipigs underwent DCCTL and DCMRL after lymphatic disruption and the detectability of lymphatic leakage was evaluated. RESULTS: The CEI peaked at 5-10 min in all microminipigs. The SIR peaked at 2-4 min in two microminipigs and at 4-10 min in one microminipig. The peak CEI and SIR values were 235.6 HU and 4.8 for venous angle, 239.4 HU and 2.1 for upper TD, and 387.3 HU and 2.1 for middle TD. The visibility and continuity of upper-middle TD scores were 4.0 and 3.3-3.7 for DCCTL, and 4.0 and 4.0 for DCMRL. In the injured lymphatic model, both DCCTL and DCMRL demonstrated lymphatic leakage. CONCLUSIONS: DCCTL and DCMRL in a microminipig model enabled excellent visualization of central lymphatic ducts and lymphatic leakage, indicating the research and clinical potential of both modalities. KEY POINTS: • Intranodal dynamic contrast-enhanced computed tomography lymphangiography showed a contrast enhancement peak at 5-10 min in all microminipigs. • Intranodal dynamic contrast-enhanced magnetic resonance lymphangiography showed a contrast enhancement peak at 2-4 min in two microminipigs and at 4-10 min in one microminipig. • Both intranodal dynamic contrast-enhanced computed tomography lymphangiography and dynamic contrast-enhanced magnetic resonance lymphangiography demonstrated the central lymphatic ducts and lymphatic leakage.


Asunto(s)
Vasos Linfáticos , Linfografía , Animales , Linfografía/métodos , Medios de Contraste/farmacología , Sistema Linfático/diagnóstico por imagen , Vasos Linfáticos/patología , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X
4.
Eur Radiol ; 33(5): 3617-3626, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36897348

RESUMEN

OBJECTIVES: To investigate the diagnostic performance and interobserver variability in the determination of arterial invasion in pancreatic ductal adenocarcinoma (PDAC) and determine the best CT imaging criterion. METHODS: We retrospectively evaluated 128 patients with PDAC (73 men and 55 women) who underwent preoperative contrast-enhanced CT. Five board-certified radiologists (expert) and four fellows (non-expert]) independently assessed the arterial invasion (celiac, superior mesenteric, splenic, and common hepatic arteries) using a 6-point score: 1, no tumor contact; 2, hazy attenuation ≤ 180°; 3, hazy attenuation > 180°; 4, solid soft tissue contact ≤ 180°; 5, solid soft tissue contact > 180°; and 6, contour irregularity. ROC analysis was performed to evaluate the diagnostic performance and determine the best diagnostic criterion for arterial invasion, with pathological or surgical findings as references. Interobserver variability was assessed using Fleiss's ĸ statistics. RESULTS: Among the 128 patients, 35.2% (n = 45/128) received neoadjuvant treatment (NTx). Solid soft tissue contact ≤ 180° was the best diagnostic criterion for arterial invasion as defined by the Youden Index both in patients who did and did not receive NTx (sensitivity, 100% vs. 100%; specificity, 90% vs. 93%; and AUC, 0.96 vs. 0.98, respectively). Interobserver variability among the non-expert was not inferior to that among the expert (ĸ = 0.61 vs 0.61; p = .39 and ĸ = 0.59 vs 0.51; p < .001 in patients treated with and without NTx, respectively). CONCLUSIONS: Solid soft tissue contact ≤ 180° was the best diagnostic criterion for the determination of arterial invasion in PDAC. Considerable interobserver variability was seen among the radiologists. KEY POINTS: • Solid soft tissue contact ≤ 180° was the best diagnostic criterion for the determination of arterial invasion in pancreatic ductal adenocarcinoma. • Interobserver agreement among non-expert radiologists was almost comparable to that among expert radiologists.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Masculino , Humanos , Femenino , Estudios Retrospectivos , Neoplasias Pancreáticas/patología , Carcinoma Ductal Pancreático/patología , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pancreáticas
5.
J Comput Assist Tomogr ; 47(3): 507-513, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37185018

RESUMEN

PURPOSE: This study aimed to assess the utility of pretreatment magnetic resonance imaging (MRI) in predicting the clinical outcomes of patients with parotid gland cancer. METHODS: A total of 43 patients with histopathologically confirmed primary parotid gland cancer, who underwent pretreatment MRI, were enrolled in this study. All images were retrospectively reviewed, and MRI features were evaluated as possible prognostic factors influencing the progression-free survival (PFS) using the Kaplan-Meier method and Cox proportional hazards regression model. Cox regression analysis was used to estimate the hazard ratios (HRs) with 95% confidence interval (95% CI) values. RESULTS: Kaplan-Meier survival analysis showed that old age (>73 years, P < 0.01), large maximum tumor diameter (>33 mm, P < 0.01), low apparent diffusion coefficient value (≤1.29 ×10 -3 mm 2 /s, P < 0.01), ill-defined margin ( P < 0.01), skin invasion ( P < 0.01), regional nodal metastasis ( P < 0.01), heterogeneous enhancement ( P < 0.05), and high signal intensity ratio on gadolinium-enhanced fat-suppressed T1-weighted images (>2.017, P < 0.05) were significant predictors of worse PFS. Cox proportional hazards regression analysis revealed that regional nodal metastasis (HR, 32.02; 95% CI, 6.42-159.84; P < 0.01) and maximum tumor diameter (HR, 1.04; 95% CI, 1.01-1.08; P < 0.05) were independent predictors of PFS. CONCLUSION: Pretreatment MRI parameters could be prognostic factors of patients with parotid gland cancer. In particular, the maximum tumor diameter and regional nodal metastasis, which were closely associated with T and N classifications, were important prognostic factors in predicting the PFS.


Asunto(s)
Glándula Parótida , Neoplasias de la Parótida , Humanos , Anciano , Pronóstico , Estudios Retrospectivos , Glándula Parótida/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de la Parótida/diagnóstico por imagen , Modelos de Riesgos Proporcionales
6.
Artículo en Inglés | MEDLINE | ID: mdl-38083833

RESUMEN

OBJECTIVE: This study aimed to assess the usefulness of magnetic resonance imaging (MRI) findings for differentiating low-grade and high-grade malignant peripheral nerve sheath tumors (MPNSTs). METHODS: This study included 31 patients (onset age range, 19-83 years; mean onset age, 57 years; 9 men and 22 women) with 36 histopathologically proven MPNSTs (7 low-grade MPNSTs and 29 high-grade MPNSTs) who underwent preoperative MRI between December 2007 and October 2022. Quantitative and qualitative MRI findings were retrospectively evaluated and compared between the 2 subtypes. RESULTS: The maximum tumor diameter (106.1 ± 64.0 vs 54.9 ± 19.8 mm, P = 0.032) and tumor-to-muscle signal intensity ratio (SIR) of fat-suppressed gadolinium-enhanced T1-weighted images (2.69 ± 1.40 vs 1.62 ± 0.40, P = 0.005) were significantly higher in high-grade MPNSTs than in low-grade MPNSTs. The receiver operating characteristic analysis revealed that the tumor-to-muscle SIR of fat-suppressed gadolinium-enhanced T1-weighted images exhibited the highest area under the curve value (0.88), followed by the maximum tumor diameter (0.76). The sensitivity and specificity of the tumor-to-muscle SIR of fat-suppressed gadolinium-enhanced T1-weighted images for diagnosing high-grade MPNST at an optimal SIR threshold of greater than 1.73 were 90% and 83%, respectively. However, other MRI findings showed no significant differences between the 2 subtypes (P = 0.16-1.00). CONCLUSIONS: Although the MRI findings of low-grade and high-grade MPNST overlapped considerably, the maximum tumor diameter and degree of contrast enhancement can be used to differentiate low-grade MPNST from high-grade MPNST.

7.
NMR Biomed ; 35(10): e4783, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35661282

RESUMEN

Reoxygenation has a significant impact on the tumor response to radiotherapy. With developments in radiotherapy technology, the relevance of the reoxygenation phenomenon in treatment efficacy has been a topic of interest. Evaluating the reoxygenation in the tumor microenvironment throughout the course of radiation therapy is important in developing effective treatment strategies. In the current study, we used electron paramagnetic resonance imaging (EPRI) to directly map and quantify the partial oxygen pressure (pO2 ) in tumor tissues. Human colorectal cancer cell lines, HT29 and HCT116, were used to induce tumor growth in female athymic nude mice. Tumors were irradiated with 3, 10, or 20 Gy using an x-ray irradiator. Prior to each EPRI scan, magnetic resonance imaging (MRI) was performed to obtain T2-weighted anatomical images for reference. The differences in the mean pO2 were determined through two-tailed Student's t-test and one-way analysis of variance. The median pO2 60 min after irradiation was found to be lower in HCT116 than in HT29 (9.1 ± 1.5 vs. 14.0 ± 1.0 mmHg, p = 0.045). There was a tendency for delayed and incomplete recovery of pO2 in the HT29 tumor when a higher dose of irradiation (10 and 20 Gy) was applied. Moreover, there was a dose-dependent increase in the hypoxic areas (pO2  < 10 mmHg) 2 and 24 h after irradiation in all groups. In addition, an area that showed pO2 fluctuation between hypoxia and normoxia (pO2  > 10 mmHg) was also identified surrounding the region with stable hypoxia, and it slightly enlarged after recovery from acute hypoxia. In conclusion, we demonstrated the reoxygenation phenomenon in an in vivo xenograft model study using EPRI. These findings may lead to new knowledge regarding the reoxygenation process and possibilities of a new radiation therapy concept, namely, reoxygenation-based radiation therapy.


Asunto(s)
Hipoxia , Neoplasias , Animales , Hipoxia de la Célula , Espectroscopía de Resonancia por Spin del Electrón/métodos , Femenino , Humanos , Ratones , Ratones Desnudos , Oxígeno/metabolismo , Microambiente Tumoral
8.
Eur Radiol ; 32(6): 4128-4136, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35061079

RESUMEN

OBJECTIVE: To assess the magnetic resonance imaging (MRI) findings of endometrial cancers and to reveal the differences between endometrioid carcinoma (EC), serous carcinoma (SC), and clear cell carcinoma (CCC). METHODS: In this study, 274 consecutive patients with histopathologically confirmed endometrial cancer (231 ECs, 25 SCs, and 18 CCCs) who underwent MRI before hysterectomy were enrolled. MRI images were retrospectively reviewed and compared between the three pathologies. RESULTS: The maximum diameters (55.6 ± 34.7 vs. 39.3 ± 21.6 vs. 39.4 ± 26.8 mm) (p < 0.05) and apparent diffusion coefficient (ADC) values (1.11 ± 0.21 vs. 0.84 ± 0.17 vs. 0.86 ± 0.16 × 10-3 mm2/s) (p < 0.01) were significantly greater in CCCs than in ECs and SCs, respectively. Infiltrative growth pattern (33% vs. 6%) (p < 0.01) was more frequent in CCCs than in ECs. Peritoneal dissemination (16% vs. 0%) (p < 0.01) and heterogeneous signal on diffusion-weighted (61% vs. 32%) (p < 0.05) images were more frequent in SCs than in ECs, respectively. Abnormal ascites (12% vs. 11% vs. 0%) and heterogeneous signal on T1-weighted (28% vs. 50% vs. 9%), T2-weighted (64% vs. 72% vs. 36%), and fat-suppressed gadolinium-enhanced T1-weighted (80% vs. 90% vs. 46%) images were more frequent in SCs and CCCs than in ECs, respectively (p < 0.05). CONCLUSIONS: SCs frequently exhibited a heterogeneous signal with peritoneal dissemination and abnormal ascites. Alternatively, CCCs tended to have a larger tumor size and higher ADC values with an infiltrative growth pattern, heterogeneous signal, and abnormal ascites. KEY POINTS: • SCs tend to have a heterogeneous signal intensity with peritoneal dissemination and abnormal ascites compared to ECs. • CCCs tend to have a heterogeneous signal intensity with an infiltrative growth pattern and abnormal ascites compared to ECs. • CCCs have a larger tumor size and higher ADC values compared to ECs and SCs.


Asunto(s)
Adenocarcinoma de Células Claras , Carcinoma Endometrioide , Neoplasias Endometriales , Neoplasias Ováricas , Adenocarcinoma de Células Claras/diagnóstico por imagen , Adenocarcinoma de Células Claras/patología , Ascitis , Carcinoma Endometrioide/diagnóstico por imagen , Carcinoma Endometrioide/patología , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias Endometriales/diagnóstico por imagen , Neoplasias Endometriales/patología , Femenino , Humanos , Imagen por Resonancia Magnética , Neoplasias Ováricas/patología , Estudios Retrospectivos
9.
Eur Radiol ; 32(1): 384-394, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34131785

RESUMEN

OBJECTIVES: To evaluate the image quality and iodine concentration (IC) measurements in pancreatic protocol dual-energy computed tomography (DECT) reconstructed using deep learning image reconstruction (DLIR) and compare them with those of images reconstructed using hybrid iterative reconstruction (IR). METHODS: The local institutional review board approved this prospective study. Written informed consent was obtained from all participants. Thirty consecutive participants with pancreatic cancer (PC) underwent pancreatic protocol DECT for initial evaluation. DECT data were reconstructed at 70 keV using 40% adaptive statistical iterative reconstruction-Veo (hybrid-IR) and DLIR at medium and high levels (DLIR-M and DLIR-H, respectively). The diagnostic acceptability and conspicuity of PC were qualitatively assessed using a 5-point scale. IC values of the abdominal aorta, pancreas, PC, liver, and portal vein; standard deviation (SD); and coefficient of variation (CV) were calculated. Qualitative and quantitative parameters were compared between the hybrid-IR, DLIR-M, and DLIR-H groups. RESULTS: The diagnostic acceptability and conspicuity of PC were significantly better in the DLIR-M group compared with those in the other groups (p < .001-.001). The IC values of the anatomical structures were almost comparable between the three groups (p = .001-.9). The SD of IC values was significantly lower in the DLIR-H group (p < .001) and resulted in the lowest CV (p < .001-.002) compared with those in the hybrid-IR and DLIR-M groups. CONCLUSIONS: DLIR could significantly improve image quality and reduce the variability of IC values than could hybrid-IR. KEY POINTS: Image quality and conspicuity of pancreatic cancer were the best in DLIR-M. DLIR significantly reduced background noise and improved SNR and CNR. The variability of iodine concentration was reduced in DLIR.


Asunto(s)
Aprendizaje Profundo , Yodo , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador , Páncreas/diagnóstico por imagen , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X
10.
BMC Med Imaging ; 22(1): 23, 2022 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-35135492

RESUMEN

BACKGROUND: To evaluate the utility of histogram analysis (HA) of apparent diffusion coefficient (ADC) values to predict the overall survival (OS) in patients with pancreatic ductal adenocarcinoma (PDAC) and to correlate with pathologically evaluated massive intratumoral necrosis (MITN). MATERIALS AND METHODS: Thirty-nine patients were included in this retrospective study with surgically resected PDAC who underwent preoperative magnetic resonance imaging. Twelve patients received neoadjuvant chemotherapy. HA on the ADC maps were performed to obtain the tumor HA parameters. Using Cox proportional regression analysis adjusted for age, time-dependent receiver-operating-characteristic (ROC) curve analysis, and Kaplan-Meier estimation, we evaluated the association between HA parameters and OS. The association between prognostic factors and pathologically confirmed MITN was assessed by logistic regression analysis. RESULTS: The median OS was 19.9 months. The kurtosis (P < 0.001), entropy (P = 0.013), and energy (P = 0.04) were significantly associated with OS. The kurtosis had the highest area under the ROC curve (AUC) for predicting 3-year survival (AUC 0.824) among these three parameters. Between the kurtosis and MITN, the logistic regression model revealed a positive correlation (P = 0.045). Lower survival rates occurred in patients with high kurtosis (cutoff value > 2.45) than those with low kurtosis (≤ 2.45) (P < 0.001: 1-year survival rate, 75.2% versus 100%: 3-year survival rate, 14.7% versus 100%). CONCLUSIONS: HA derived kurtosis obtained from tumor ADC maps might be a potential imaging biomarker for predicting the presence of MITN and OS in patients with PDAC.


Asunto(s)
Carcinoma Ductal Pancreático/mortalidad , Carcinoma Ductal Pancreático/patología , Neoplasias Pancreáticas/mortalidad , Neoplasias Pancreáticas/patología , Anciano , Anciano de 80 o más Años , Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/terapia , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Necrosis , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/terapia , Modelos de Riesgos Proporcionales , Análisis de Regresión , Estudios Retrospectivos , Tasa de Supervivencia , Neoplasias Pancreáticas
11.
Radiol Med ; 127(12): 1383-1389, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36350422

RESUMEN

OBJECTIVE: This study aimed to assess the efficacy of using MRI findings for differentiating musculoskeletal dedifferentiated liposarcoma (DDLP) from atypical lipomatous tumor (ALT). MATERIALS AND METHODS: This study included 22 patients with histopathologically proven DDLP and 35 with ALT in the musculoskeletal areas. All DDLPs were immunohistochemically positive for MDM2. MRI findings for both pathologies were retrospectively reviewed and compared. RESULTS: The maximum lesion diameter was significantly lower in DDLPs than in ALTs (p < 0.01). Ill-defined margin, peritumoral edema, and tail sign were more frequently observed in DDLPs than in ALTs (p < 0.01, respectively). The fatty component was less frequently observed in DDLPs than in ALTs (27 vs. 100%; p < 0.01), whereas the non-fatty component was more frequently observed in DDLPs than in ALTs (100 vs. 11%; p < 0.01). The occupation rate by non-fatty components was significantly higher in DDLPs than in ALTs (p < 0.01). No significant differences were observed in imaging findings associated with fatty component; however, necrosis within the non-fatty component on the contrast-enhanced image was more frequently observed in DDLPs than in ALTs (72 vs. 0%, p < 0.05). CONCLUSION: DDLPs always had a non-fatty component, whereas ALTs always had fatty component. Ill-defined margin, peritumoral edema, tail sign, and necrosis within non-fatty components were useful MRI features for differentiating musculoskeletal DDLP from ALT.


Asunto(s)
Liposarcoma , Humanos , Estudios Retrospectivos , Liposarcoma/diagnóstico por imagen , Liposarcoma/patología , Imagen por Resonancia Magnética/métodos , Necrosis
12.
Anal Chem ; 93(42): 14138-14145, 2021 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-34649431

RESUMEN

Free radicals, such as metabolic intermediates, reactive oxygen species, and metal enzymes, are key substances in organisms, although they can also cause various oxidative diseases. Thus, in vivo free radical imaging should be considered as the ultimate form of metabolic imaging. Unfortunately, electron spin resonance (ESR) imaging has inherent disadvantages, such as free radicals with large linewidths generating blurred images and the presence of two or more free radicals resulting in a complicated imaging procedure. Dynamic nuclear polarization-magnetic resonance imaging (DNP-MRI) is a noninvasive imaging method to visualize in vivo free radicals, theoretically, with the same resolution as the MRI anatomical resolution, and fixed low-field DNP-MRI provides unique information on oxidative diseases and cancer. However, the large gyromagnetic ratio of the electron spin, which is 660-fold greater than that of a proton, requires field cycling, wherein the external magnetic field should be varied during DNP-MRI observations. This causes difficulties in developing a DNP-MRI system for clinical purposes. We developed a novel field-cycling DNP-MRI system for a preclinical study. In the said system, the magnetic field is switched by rotationally moving two magnets, with a magnetic flux density of 0.3 T for MRI and 5 mT for ESR. The image quality was examined using various pulse sequences and ESR irradiation using nitroxyl radical as the phantom, and the optimum conditions were established. Using the system, we performed a preclinical study involving free radical imaging by placing the free radicals under the palm of a human hand.


Asunto(s)
Imagen por Resonancia Magnética , Espectroscopía de Resonancia por Spin del Electrón , Radicales Libres , Humanos , Oxidación-Reducción , Fantasmas de Imagen
13.
Radiology ; 300(3): 615-623, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34128721

RESUMEN

Background The bolus-tracking technique from single-energy CT has been applied to dual-energy CT (DECT) without optimization or validation. Further optimization is imperative because of a paucity of literature and differences in the attenuation profile of virtual monoenergetic images (VMIs). Purpose To determine the optimal trigger threshold with bolus-tracking technique for DECT angiography (DECTA) in a phantom study and assess the feasibility of an optimized threshold for bolus-tracking technique in DECTA at 40 keV with a 50% reduced iodine dose in human participants. Materials and Methods A phantom study with rapid kilovoltage-switching DECT was performed to determine the optimal threshold for each kiloelectron-volt VMI. In a prospective study, consecutive participants who underwent whole-body CT angiography (CTA) from August 2018 to July 2019 were randomized into three groups: single-energy CTA (SECTA) with standard iodine dose (600 mg of iodine per kilogram), DECTA with 50% reduced iodine dose (300 mg of iodine per kilogram) by using a conventional threshold, and DECTA with 300 mg of iodine per kilogram by using an optimized threshold. A trigger threshold of 100 HU at 120 kVp was used as a reference for comparison. Injected iodine doses and aortic CT numbers were compared among the three groups using Kruskal-Wallis test. Results Ninety-six participants (mean age ± standard deviation, 72 years ± 9; 80 men) were evaluated (32 participants in each group). The optimized threshold for VMIs at 40 keV was 30 HU. The median iodine dose was lower in the optimized DECTA group (13 g) compared with conventional DECTA (19 g) and SECTA (26 g) groups (P < .017 for each comparison). The median aortic CT numbers were higher in the order corresponding to conventional DECTA (655-769 HU), optimized DECTA (543-610 HU), and SECTA (343-359 HU) groups (P < .001). Conclusion The optimized trigger threshold of 30 HU for bolus-tracking technique during dual-energy CT angiography at 40 keV achieved lower iodine load while maintaining aortic enhancement. ©RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Malayeri in this issue.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/administración & dosificación , Yopamidol/administración & dosificación , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Anciano , Femenino , Humanos , Masculino , Fantasmas de Imagen , Estudios Prospectivos
14.
J Appl Clin Med Phys ; 22(9): 271-279, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34375008

RESUMEN

PURPOSE: We evaluated the effect of changing the scan mode of the Elekta X-ray volume imaging cone beam computed tomography (CBCT) on the accuracy of dose calculation, which may be affected by computed tomography (CT) value errors in three dimensions. METHODS: We used the electron density phantom and measured the CT values in three dimensions. CT values were compared with planning computed tomography (pCT) values for various materials. The evaluated scan modes were for head and neck (S-scan), chest (M-scan), and pelvis (L-scan) with various collimators and filter systems. To evaluate the effects of the CT value error of the CBCT on dose error, Monte Carlo calculations of dosimetry were performed using pCT and CBCT images. RESULTS: The L-scan had a CT value error of approximately 800 HU at the isocenter compared with the pCT. Furthermore, inhomogeneity in the longitudinal CT value profile was observed in the bone material. The dose error for ±100 HU difference in CT values for the S-scan and M-scan was within ±2%. The center of the L-scan had a CT error of approximately 800 HU and a dose error of approximately 6%. The dose error of the L-scan occurred in the beam path in the case of both single field and two parallel opposed fields, and the maximum error occurred at the center of the phantom in the case of both the 4-field box and single-arc techniques. CONCLUSIONS: We demonstrated the three-dimensional CT value characteristics of the CBCT by evaluating the CT value error obtained under various imaging conditions. It was found that the L-scan is considerably affected by not having a unique bowtie filter, and the S-scan without the bowtie filter causes CT value errors in the longitudinal direction. Moreover, the CBCT dose errors for the 4-field box and single-arc irradiation techniques converge to the isocenter.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Rayos X
15.
Anal Chem ; 92(21): 14408-14414, 2020 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-33064938

RESUMEN

Reactive oxygen species (ROS) play an important role in cell metabolism, but they can cause oxidative damage to biomolecules. Among ROS, the hydroxyl radical (·OH) is one of the most reactive molecules in biological systems because of its high reaction rate constant. Therefore, imaging of ·OH could be useful for evaluation of the redox mechanism and diagnosis of oxidative diseases. In vivo dynamic nuclear polarization-magnetic resonance imaging (DNP-MRI) is a noninvasive imaging method to obtain spatiotemporal information about free radicals with MRI anatomical resolution. In this study, we investigated the visualization of hydroxyl radicals generated from the Fenton reaction by combining DNP-MRI with a spin-trapping agent (DMPO: 5,5-dimethyl-1-pyrroline N-oxide) for ·OH. Additionally, we demonstrated the radical-scavenging effect using four thiol-related reagents by DNP-MRI. We demonstrated that DNP enhancement could be induced by the DMPO-OH radical using the DNP-MRI/spin-trapping method and visualized ·OH generation for the first time. Maximum DNP enhancement was observed at an electron paramagnetic resonance irradiation frequency of 474.5 MHz. Furthermore, the radical-scavenging effect was simultaneously evaluated by the decrease in the DNP image value of DMPO-OH. An advantage of our methods is that they simultaneously investigate compound activity and the radical-scavenging effect.


Asunto(s)
Radical Hidroxilo/química , Radical Hidroxilo/metabolismo , Imagen por Resonancia Magnética , Detección de Spin , Óxidos N-Cíclicos/química , Peróxido de Hidrógeno/química , Hierro/química , Factores de Tiempo
16.
Eur Radiol ; 30(11): 5913-5922, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32591882

RESUMEN

OBJECTIVES: To evaluate the optimal imaging protocol and the feasibility of intranodal dynamic contrast-enhanced computed tomography lymphangiography (DCCTL) in microminipigs. METHODS: The Committee for Animal Research and Welfare provided university approval. Five female microminipigs underwent DCCTL after inguinal lymph node injection of 0.1 mL/kg of iodine contrast media at a rate of 0.3 mL/min with three different iodine concentrations: group 1, 75 mgI/mL; group 2, 150 mgI/mL; and group 3, 300 mgI/mL. The CT values of the venous angle, thoracic duct (TD), cisterna chyli, iliac lymphatic duct, and iliac lymph node were measured; increases in CT values pre- to post-contrast were assessed as the contrast-enhanced index (CEI). Multi-detector row CT (MDCT) and volume rendering images showing the highest CEI were qualitatively evaluated. RESULTS: The CEI of all lymphatics peaked at 5-10 min. The mean CEI of TD at 10 min of group 2 (193.0 HU) and group 3 (201.5 HU) were significantly higher than that of group 1 (70.7 HU) (p = 0.024). The continuity and overall diagnostic acceptability of all lymphatic system components were better in group 3 (3.6 and 3.0, respectively) than group 1 (2.6 and 1.6) and group 2 (3.0 and 2.6) (p = 0.249 and 0.204). CONCLUSIONS: The optimal imaging protocol for intranodal DCCTL could be dual-phase imaging at 5 and 10 min after the injection of 300 mgI/mL iodinated contrast media. DCCTL provided good images of lymphatics and is potentially feasible in clinical settings. KEY POINTS: • Dynamic contrast-enhanced computed tomography lymphangiography with intranodal injection of water-soluble iodine contrast media showed the highest enhancement of all lymphatics at scan delays of 5 and 10 min. • The optimal iodine concentration for intranodal dynamic contrast-enhanced computed tomography lymphangiography might be 300 mgI/mL. • Intranodal dynamic contrast-enhanced computed tomography lymphangiography provided good images of all the lymphatic system components and is potentially feasible in clinical settings.


Asunto(s)
Medios de Contraste/farmacología , Ganglios Linfáticos/diagnóstico por imagen , Sistema Linfático/diagnóstico por imagen , Linfografía/métodos , Tomografía Computarizada Espiral/métodos , Animales , Estudios de Factibilidad , Femenino , Inyecciones , Modelos Animales , Porcinos , Porcinos Enanos
17.
Neuroradiology ; 62(10): 1207-1217, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32562036

RESUMEN

PURPOSE: On T2-weighted images, most solid lesions exhibit nonspecific intermediate signal intensity, whereas most cystic lesions exhibit marked hyperintensity. In contrast, on T2-weighted images, a relatively small number of lesions exhibit hypointensity. This review aimed to differentiate, according to the histopathologic findings, head and neck lesions showing hypointensity on T2-weighted images. METHODS: In this review article, hypointense head and neck lesions on T2-weighted images are classified into the following nine categories: calcified or osseous lesions, granulomatous lesions, fibrous lesions, mucous- or proteincontaining lesions, hemosiderin-containing lesions, melanin-containing lesions, thyroglobulin-containing lesions, rapid blood flow, and air-filled spaces. CONCLUSION: Knowledge regarding hypointense head and neck lesions on T2-weighted images allows radiologists to make accurate differential diagnoses. Key points • Hypointense head and neck lesions on T2-weighted images include calcified or osseous lesions, granulomatous lesions, fibrous lesions, mucous- or protein-containing lesions, hemosiderin-containing lesions, melanin-containing lesions, thyroglobulin-containing lesions, rapid blood flow, and air-filled spaces. • Radiologists should recognize the hypointense head and neck lesions on T2-weighted images for the final correct diagnosis, resulting in appropriate patient management.


Asunto(s)
Cabeza/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Cuello/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Medios de Contraste , Quistes/diagnóstico por imagen , Quistes/patología , Diagnóstico Diferencial , Cabeza/irrigación sanguínea , Cabeza/patología , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/patología , Humanos , Cuello/irrigación sanguínea , Cuello/patología
18.
Biol Pharm Bull ; 43(9): 1413-1420, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32879216

RESUMEN

The gut-liver axis may be involved in non-alcoholic steatohepatitis (NASH) progression. Pathogen-associated molecular patterns leak through the intestinal barrier to the liver via the portal vein to contribute to NASH development. Active vitamin D3 (1,25(OH)2D3) is a potential therapeutic agent to enhance the intestinal barrier. Active vitamin D3 also suppresses inflammation and fibrosis in the liver. However, the adverse effects of active vitamin D3 such as hypercalcemia limit its clinical use. We created a nano-structured lipid carrier (NLC) containing active vitamin D3 to deliver active vitamin D3 to the intestine and liver to elicit NASH treatment. We found a suppressive effect of the NLC on the lipopolysaccharide-induced increase in permeability of an epithelial layer in vitro. Using mice in which NASH was induced by a methionine and choline-deficient diet, we discovered that oral application of the NLC ameliorated the permeability increase in the intestinal barrier and attenuated steatosis, inflammation and fibrosis in liver at a safe dose of active vitamin D3 at which the free form of active vitamin D3 did not show a therapeutic effect. These data suggest that the NLC is a novel therapeutic agent for NASH.


Asunto(s)
Calcitriol/administración & dosificación , Portadores de Fármacos/química , Hepatitis/tratamiento farmacológico , Mucosa Intestinal/efectos de los fármacos , Enfermedad del Hígado Graso no Alcohólico/tratamiento farmacológico , Administración Oral , Animales , Células CACO-2 , Calcitriol/efectos adversos , Técnicas de Cultivo de Célula , Técnicas de Cocultivo , Modelos Animales de Enfermedad , Microbioma Gastrointestinal/inmunología , Hepatitis/inmunología , Hepatitis/patología , Humanos , Hipercalcemia/inducido químicamente , Hipercalcemia/prevención & control , Mucosa Intestinal/inmunología , Mucosa Intestinal/microbiología , Mucosa Intestinal/patología , Lípidos/química , Lipopolisacáridos/administración & dosificación , Lipopolisacáridos/toxicidad , Hígado/inmunología , Hígado/patología , Masculino , Metionina/administración & dosificación , Metionina/toxicidad , Ratones , Nanopartículas/química , Enfermedad del Hígado Graso no Alcohólico/inducido químicamente , Enfermedad del Hígado Graso no Alcohólico/inmunología , Enfermedad del Hígado Graso no Alcohólico/patología , Moléculas de Patrón Molecular Asociado a Patógenos/inmunología , Moléculas de Patrón Molecular Asociado a Patógenos/metabolismo , Permeabilidad , Células RAW 264.7
19.
Kidney Int ; 96(3): 787-792, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31345583

RESUMEN

Renal hypoxia may play an important role in the progression of diabetic nephropathy. However, tools that noninvasively and quantitatively measure oxygen tension in the kidney are lacking. Here, we evaluated the feasibility of a noninvasive and quantitative imaging technique using dynamic nuclear polarization magnetic resonance imaging (DNP-MRI) in combination with the oxygen-sensitive paramagnetic agent OX63 for measuring oxygen tension in the kidney. Our results demonstrate that the DNP-MRI technique can yield quantitative maps of oxygen tension in the mouse renal cortex. Using this procedure, we also showed that oxygen tension was less elevated in the renal cortex of both streptozotocin-induced type 1 diabetic mice and db/db mice, a model of type 2 diabetes, than in the renal cortex of age-matched control mice of each respective model. Oxygen tension in streptozotocin-exposed mice was significantly improved by insulin treatment. Thus, the noninvasive and quantitative DNP-MRI technique appears to be useful for studying the pathophysiological role of hypoxia.


Asunto(s)
Diabetes Mellitus Experimental/complicaciones , Diabetes Mellitus Tipo 1/complicaciones , Nefropatías Diabéticas/diagnóstico , Corteza Renal/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Animales , Hipoxia de la Célula , Diabetes Mellitus Experimental/inducido químicamente , Diabetes Mellitus Tipo 1/inducido químicamente , Nefropatías Diabéticas/patología , Modelos Animales de Enfermedad , Humanos , Indenos/administración & dosificación , Corteza Renal/patología , Ratones , Oxígeno/análisis , Estreptozocina/toxicidad , Compuestos de Tritilo/administración & dosificación
20.
Biochem Biophys Res Commun ; 496(1): 140-146, 2018 01 29.
Artículo en Inglés | MEDLINE | ID: mdl-29307833

RESUMEN

Clinical application of the major anticancer drug, cisplatin, is limited by severe side effects, especially acute kidney injury (AKI) caused by nephrotoxicity. The detailed metabolic mechanism is still largely unknown. Here, we used an integrated technique combining mass spectrometry imaging (MSI) and liquid chromatography-mass spectrometry (LC-MS) to visualize the diverse spatiotemporal metabolic dynamics in the mouse kidney after cisplatin dosing. Biological responses to cisplatin was more sensitively detected within 24 h as a metabolic alteration, which is much earlier than possible with the conventional clinical chemistry method of blood urea nitrogen (BUN) measurement. Region-specific changes (e.g., medulla and cortex) in metabolites related to DNA damage and energy generation were observed over the 72-h exposure period. Therefore, this metabolomics approach may become a novel strategy for elucidating early renal responses to cisplatin, prior to the detection of kidney damage evaluated by conventional method.


Asunto(s)
Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/metabolismo , Cisplatino/efectos adversos , Riñón/efectos de los fármacos , Riñón/metabolismo , Metaboloma , Análisis Espacio-Temporal , Animales , Cromatografía Liquida/métodos , Cisplatino/administración & dosificación , Relación Dosis-Respuesta a Droga , Masculino , Espectrometría de Masas/métodos , Tasa de Depuración Metabólica , Ratones , Ratones Endogámicos C57BL , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribución Tisular
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda