Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Eur Radiol ; 34(2): 1065-1076, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37580601

RESUMEN

OBJECTIVE: The purpose of this study was thus to compare capabilities for quantitative differentiation of non- and minimally invasive adenocarcinomas from other of pulmonary MRIs with ultra-short TE (UTE) obtained with single- and dual-echo techniques (UTE-MRISingle and UTE-MRIDual) and thin-section CT for stage IA lung cancer patients. METHODS: Ninety pathologically diagnosed stage IA lung cancer patients who underwent thin-section standard-dose CT, UTE-MRISingle, and UTE-MRIDual, surgical treatment and pathological examinations were included in this retrospective study. The largest dimension (Dlong), solid portion (solid Dlong), and consolidation/tumor (C/T) ratio of each nodule were assessed. Two-tailed Student's t-tests were performed to compare all indexes obtained with each method between non- and minimally invasive adenocarcinomas and other lung cancers. Receiver operating characteristic (ROC)-based positive tests were performed to determine all feasible threshold values for distinguishing non- or minimally invasive adenocarcinoma (MIA) from other lung cancers. Sensitivity, specificity, and accuracy were then compared by means of McNemar's test. RESULTS: Each index showed significant differences between the two groups (p < 0.0001). Specificities and accuracies of solid Dlong for UTE-MRIDual2nd echo and CTMediastinal were significantly higher than those of solid Dlong for UTE-MRISingle and UTE-MRIDual1st echo and all C/T ratios except CTMediastinal (p < 0.05). Moreover, the specificities and accuracies of solid Dlong and C/T ratio were significantly higher than those of Dlong for each method (p < 0.05). CONCLUSION: Pulmonary MRI with UTE is considered at least as valuable as thin-section CT for quantitative differentiation of non- and minimally invasive adenocarcinomas from other stage IA lung cancers. CLINICAL RELEVANCE STATEMENT: Pulmonary MRI with UTE's capability for quantitative differentiation of non- and minimally invasive adenocarcinomas from other lung cancers in stage IA lung cancer patients is equal or superior to that of thin-section CT. KEY POINTS: • Correlations were excellent for pathologically examined nodules with the largest dimensions (Dlong) and a solid component (solid Dlong) for all indexes (0.95 ≤ r ≤ 0.99, p < 0.0001). • Pathologically examined Dlong and solid Dlong obtained with all methods showed significant differences between non- and minimally invasive adenocarcinomas and other lung cancers (p < 0.0001). • Solid tumor components are most accurately measured by UTE-MRIDual2nd echo and CTMediastinal, whereas the ground-glass component is imaged by UTE-MRIDual1st echo and CTlung with high accuracy. UTE-MRIDual predicts tumor invasiveness with 100% sensitivity and 87.5% specificity at a C/T threshold of 0.5.


Asunto(s)
Adenocarcinoma , Enfermedades Pulmonares , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/patología , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Pulmón/patología , Adenocarcinoma/patología , Imagen por Resonancia Magnética/métodos
2.
J Magn Reson Imaging ; 58(1): 174-186, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36971493

RESUMEN

BACKGROUND: Amide proton transfer (APT) weighted chemical exchange saturation transfer CEST (APTw/CEST) magnetic resonance imaging (MRI) has been suggested as having the potential for assessing the therapeutic effect of brain tumors or rectal cancer. Moreover, diffusion-weighted imaging (DWI) and positron emission tomography fused with computed tomography by means of 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG-PET/CT) have been suggested as useful in same setting. PURPOSE: To compare the capability of APTw/CEST imaging, DWI, and FDG-PET/CT for predicting therapeutic effect of chemoradiotherapy (CRT) on stage III non-small cell lung cancer (NSCLC) patients. STUDY TYPE: Prospective. POPULATION: Eighty-four consecutive patients with Stage III NSCLC, 45 men (age range, 62-75 years; mean age, 71 years) and 39 women (age range, 57-75 years; mean age, 70 years). All patients were then divided into two groups (Response Evaluation Criteria in Solid Tumors [RECIST] responders, consisting of the complete response and partial response groups, and RECIST non-responders, consisting of the stable disease and progressive disease groups). FIELD STRENGTH/SEQUENCE: 3 T, echo planar imaging or fast advanced spin-echo (FASE) sequences for DWI and 2D half Fourier FASE sequences with magnetization transfer pulses for CEST imaging. ASSESSMENT: Magnetization transfer ratio asymmetry (MTRasym ) at 3.5 ppm, apparent diffusion coefficient (ADC), and maximum standard uptake value (SUVmax, ) on PET/CT were assessed by means of region of interest (ROI) measurements at primary tumor. STATISTICAL TESTS: Kaplan-Meier method followed by log-rank test and Cox proportional hazards regression analysis with multivariate analysis. A P value <0.05 was considered statistically significant. RESULTS: Progression-free survival (PFS) and overall survival (OS) had significant difference between two groups. MTRasym at 3.5 ppm (hazard ratio [HR] = 0.70) and SUVmax (HR = 1.41) were identified as significant predictors for PFS. Tumor staging (HR = 0.57) was also significant predictors for OS. DATA CONCLUSION: APTw/CEST imaging showed potential performance as DWI and FDG-PET/CT for predicting the therapeutic effect of CRT on stage III NSCLC patients. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/terapia , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/terapia , Neoplasias Pulmonares/patología , Fluorodesoxiglucosa F18 , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Quimioradioterapia , Radiofármacos
3.
J Magn Reson Imaging ; 57(1): 259-272, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35753082

RESUMEN

BACKGROUND: Computed diffusion-weighted imaging (cDWI) is a mathematical computation technique that generates DWIs for any b-value by using actual DWI (aDWI) data with at least two different b-values and may improve differentiation of metastatic from nonmetastatic lymph nodes. PURPOSE: To determine the appropriate b-value for cDWI to achieve a better diagnostic capability for lymph node staging (N-staging) in non-small cell lung cancer (NSCLC) patients compared to aDWI, short inversion time (TI) inversion recovery (STIR) imaging, or positron emission tomography with 2-[fluorine-18] fluoro-2-deoxy-d-glucose combined with computed tomography (FDG-PET/CT). STUDY TYPE: Prospective. SUBJECTS: A total of 245 (127 males and 118 females; mean age 72 years) consecutive histopathologically confirmed NSCLC patients. FIELD STRENGTH/SEQUENCE: A 3 T, half-Fourier single-shot turbo spin-echo sequence, electrocardiogram (ECG)-triggered STIR fast advanced spin-echo (FASE) sequence with black blood and STIR acquisition and DWI obtained by FASE with b-values of 0 and 1000 sec/mm2 . ASSESSMENT: From aDWIs with b-values of 0 and 1000 (aDWI1000 ) sec/mm2 , cDWI using 400 (cDWI400 ), 600 (cDWI600 ), 800 (cDWI800 ), and 2000 (cDWI2000 ) sec/mm2 were generated. Then, 114 metastatic and 114 nonmetastatic nodes (mediastinal and hilar lymph nodes) were selected and evaluated with a contrast ratio (CR) for each cDWI and aDWI, apparent diffusion coefficient (ADC), lymph node-to-muscle ratio (LMR) on STIR, and maximum standard uptake value (SUVmax ). STATISTICAL TESTS: Receiver operating characteristic curve (ROC) analysis, Youden index, and McNemar's test. RESULTS: Area under the curve (AUC) of CR600 was significantly larger than the CR400 , CR800 , CR2000 , aCR1000 , and SUVmax . Comparison of N-staging accuracy showed that CR600 was significantly higher than CR400 , CR2000 , ADC, aCR1000 , and SUVmax , although there were no significant differences with CR800 (P = 0.99) and LMR (P = 0.99). DATA CONCLUSION: cDWI with b-value at 600 sec/mm2 may have potential to improve N-staging accuracy as compared with aDWI, STIR, and PET/CT. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Masculino , Femenino , Humanos , Anciano , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Prospectivos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Tomografía de Emisión de Positrones/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Desoxiglucosa , Fluorodesoxiglucosa F18 , Radiofármacos , Estadificación de Neoplasias
4.
Eur Radiol ; 33(1): 368-379, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35841417

RESUMEN

OBJECTIVE: Ultra-high-resolution CT (UHR-CT), which can be applied normal resolution (NR), high-resolution (HR), and super-high-resolution (SHR) modes, has become available as in conjunction with multi-detector CT (MDCT). Moreover, deep learning reconstruction (DLR) method, as well as filtered back projection (FBP), hybrid-type iterative reconstruction (IR), and model-based IR methods, has been clinically used. The purpose of this study was to directly compare lung CT number and airway dimension evaluation capabilities of UHR-CT using different scan modes with those of MDCT with different reconstruction methods as investigated in a lung density and airway phantom design recommended by QIBA. MATERIALS AND METHODS: Lung CT number, inner diameter (ID), inner area (IA), and wall thickness (WT) were measured, and mean differences between measured CT number, ID, IA, WT, and standard reference were compared by means of Tukey's HSD test between all UHR-CT data and MDCT reconstructed with FBP as 1.0-mm section thickness. RESULTS: For each reconstruction method, mean differences in lung CT numbers and all airway parameters on 0.5-mm and 1-mm section thickness CTs obtained with SHR and HR modes showed significant differences with those obtained with the NR mode on UHR-CT and MDCT (p < 0.05). Moreover, the mean differences on all UHR-CTs obtained with SHR, HR, or NR modes were significantly different from those of 1.0-mm section thickness MDCTs reconstructed with FBP (p < 0.05). CONCLUSION: Scan modes and reconstruction methods used for UHR-CT were found to significantly affect lung CT number and airway dimension evaluations as did reconstruction methods used for MDCT. KEY POINTS: • Scan and reconstruction methods used for UHR-CT showed significantly higher CT numbers and smaller airway dimension evaluations as did those for MDCT in a QIBA phantom study (p < 0.05). • Mean differences in lung CT number for 0.25-mm, 0.5-mm, and 1.0-mm section thickness CT images obtained with SHR and HR modes were significantly larger than those for CT images at 1.0-mm section thickness obtained with MDCT and reconstructed with FBP (p < 0.05). • Mean differences in inner diameter (ID), inner area (IA), and wall thickness (WT) measured with SHR and HR modes on 0.5- and 1.0-mm section thickness CT images were significantly smaller than those obtained with NR mode on UHR-CT and MDCT (p < 0.05).


Asunto(s)
Aprendizaje Profundo , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Pulmón/diagnóstico por imagen , Tórax , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Algoritmos
5.
J Comput Assist Tomogr ; 47(3): 494-499, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37185016

RESUMEN

OBJECTIVE: Although amide proton transfer-weighted (APTw) imaging is reported by 2-dimensional (2D) spin-echo-based sequencing, 3-dimensional (3D) APTw imaging can be obtained by gradient-echo-based sequencing. The purpose of this study was to compare the efficacy of APTw imaging between 2D and 3D imaging in patients with various brain tumors. METHODS: A total of 49 patients who had undergone 53 examinations [5 low-grade gliomas (LGG), 16 high-grade gliomas (HGG), 6 malignant lymphomas, 4 metastases, and 22 meningiomas] underwent APTw imaging using 2D and 3D sequences. The magnetization transfer ratio asymmetry (MTR asym ) was assessed by means of region of interest measurements. Pearson correlation was performed to determine the relationship between MTR asym for the 2 methods, and Student's t test to compare MTR asym for LGG and HGG. The diagnostic accuracy to differentiate HGG from LGG of the 2 methods was compared by means of the McNemar test. RESULTS: Three-dimensional APTw imaging showed a significant correlation with 2D APTw imaging ( r = 0.79, P < 0.0001). The limits of agreement between the 2 methods were -0.021 ± 1.42%. The MTR asym of HGG (2D: 1.97 ± 0.96, 3D: 2.11 ± 0.95) was significantly higher than those of LGG (2D: 0.46 ± 0.89%, P < 0.01; 3D: 0.15 ± 1.09%, P < 0.001). The diagnostic performance of the 2 methods to differentiate HGG from LGG was not significantly different ( P = 1). CONCLUSIONS: The potential capability of 3D APTw imaging is equal to or greater than that of 2D APTw imaging and is considered at least as valuable in patients with brain tumors.


Asunto(s)
Neoplasias Encefálicas , Glioma , Neoplasias Meníngeas , Humanos , Protones , Imagen por Resonancia Magnética/métodos , Amidas , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Glioma/diagnóstico por imagen , Glioma/patología , Imagenología Tridimensional
6.
Radiology ; 303(2): 373-381, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35103536

RESUMEN

Background Deep learning reconstruction (DLR) may improve image quality. However, its impact on diffusion-weighted imaging (DWI) of the prostate has yet to be assessed. Purpose To determine whether DLR can improve image quality of diffusion-weighted MRI at b values ranging from 1000 sec/mm2 to 5000 sec/mm2 in patients with prostate cancer. Materials and Methods In this retrospective study, images of the prostate obtained at DWI with a b value of 0 sec/mm2, DWI with a b value of 1000 sec/mm2 (DWI1000), DWI with a b value of 3000 sec/mm2 (DWI3000), and DWI with a b value of 5000 sec/mm2 (DWI5000) from consecutive patients with biopsy-proven cancer from January to June 2020 were reconstructed with and without DLR. Image quality was assessed using signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) from region-of-interest analysis and qualitatively assessed using a five-point visual scoring system (1 [very poor] to 5 [excellent]) for each high-b-value DWI sequence with and without DLR. The SNR, CNR, and visual score for DWI with and without DLR were compared with the paired t test and the Wilcoxon signed rank test with Bonferroni correction, respectively. Apparent diffusion coefficients (ADCs) from DWI with and without DLR were also compared with the paired t test with Bonferroni correction. Results A total of 60 patients (mean age, 67 years; age range, 49-79 years) were analyzed. DWI with DLR showed significantly higher SNRs and CNRs than DWI without DLR (P < .001); for example, with DWI1000 the mean SNR was 38.7 ± 0.6 versus 17.8 ± 0.6, respectively (P < .001), and the mean CNR was 18.4 ± 5.6 versus 7.4 ± 5.6, respectively (P < .001). DWI with DLR also demonstrated higher qualitative image quality than DWI without DLR (mean score: 4.8 ± 0.4 vs 4.0 ± 0.7, respectively, with DWI1000 [P = .001], 3.8 ± 0.7 vs 3.0 ± 0.8 with DWI3000 [P = .002], and 3.1 ± 0.8 vs 2.0 ± 0.9 with DWI5000 [P < .001]). ADCs derived with and without DLR did not differ substantially (P > .99). Conclusion Deep learning reconstruction improves the image quality of diffusion-weighted MRI scans of prostate cancer with no impact on apparent diffusion coefficient quantitation with a 3.0-T MRI system. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Turkbey in this issue.


Asunto(s)
Aprendizaje Profundo , Neoplasias de la Próstata , Anciano , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Masculino , Persona de Mediana Edad , Próstata , Neoplasias de la Próstata/diagnóstico por imagen , Estudios Retrospectivos
7.
Radiology ; 302(3): 697-706, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34846203

RESUMEN

Background Pulmonary MRI with ultrashort echo time (UTE) has been compared with chest CT for nodule detection and classification. However, direct comparisons of these methods' capabilities for Lung CT Screening Reporting and Data System (Lung-RADS) evaluation remain lacking. Purpose To compare the capabilities of pulmonary MRI with UTE with those of standard- or low-dose thin-section CT for Lung-RADS classification. Materials and Methods In this prospective study, standard- and low-dose chest CT (270 mA and 60 mA, respectively) and MRI with UTE were used to examine consecutive participants enrolled between January 2017 and December 2020 who met American College of Radiology Appropriateness Criteria for lung cancer screening with low-dose CT. Probability of nodule presence was assessed for all methods with a five-point visual scoring system by two board-certified radiologists. All nodules were then evaluated in terms of their Lung-RADS classification using each method. To compare nodule detection capability of the three methods, consensus for performances was rated by using jackknife free-response receiver operating characteristic analysis, and sensitivity was compared by means of the McNemar test. In addition, weighted κ statistics were used to determine the agreement between Lung-RADS classification obtained with each method and the reference standard generated from standard-dose CT evaluated by two radiologists who were not included in the image analysis session. Results A total of 205 participants (mean age: 64 years ± 7 [standard deviation], 106 men) with 1073 nodules were enrolled. Figure of merit (FOM) (P < .001) had significant differences among three modalities (standard-dose CT: FOM = 0.91, low-dose CT: FOM = 0.89, pulmonary MRI with UTE: FOM = 0.94), with no evidence of false-positive findings in participants with all modalities (P > .05). Agreements for Lung-RADS classification between all modalities and the reference standard were almost perfect (standard-dose CT: κ = 0.82, P < .001; low-dose CT: κ = 0.82, P < .001; pulmonary MRI with UTE: κ = 0.82, P < .001). Conclusion In a lung cancer screening population, ultrashort echo time pulmonary MRI was comparable to standard- or low-dose CT for Lung CT Screening Reporting and Data System classification. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Wielpütz in this issue.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Detección Precoz del Cáncer , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
8.
Eur Radiol ; 32(10): 6658-6667, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35687136

RESUMEN

OBJECTIVE: To compare the utility of deep learning reconstruction (DLR) for improving acquisition time, image quality, and intraductal papillary mucinous neoplasm (IPMN) evaluation for 3D MRCP obtained with parallel imaging (PI), multiple k-space data acquisition for each repetition time (TR) technique (Fast 3D mode multiple: Fast 3Dm) and compressed sensing (CS) with PI. MATERIALS AND METHODS: A total of 32 IPMN patients who had undergone 3D MRCPs obtained with PI, Fast 3Dm, and CS with PI and reconstructed with and without DLR were retrospectively included in this study. Acquisition time, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) obtained with all protocols were compared using Tukey's HSD test. Results of endoscopic ultrasound, ERCP, surgery, or pathological examination were determined as standard reference, and distribution classifications were compared among all 3D MRCP protocols by McNemar's test. RESULTS: Acquisition times of Fast 3Dm and CS with PI with and without DLR were significantly shorter than those of PI with and without DLR (p < 0.05). Each MRCP sequence with DLR showed significantly higher SNRs and CNRs than those without DLR (p < 0.05). IPMN distribution accuracy of PI with and without DLR and Fast 3Dm with DLR was significantly higher than that of Fast 3Dm without DLR and CS with PI without DLR (p < 0.05). CONCLUSION: DLR is useful for improving image quality and IPMN evaluation capability on 3D MRCP obtained with PI, Fast 3Dm, or CS with PI. Moreover, Fast 3Dm and CS with PI may play as substitution to PI for MRCP in patients with IPMN. KEY POINTS: • Mean examination times of multiple k-space data acquisitions for each TR and compressed sensing with parallel imaging were significantly shorter than that of parallel imaging (p < 0.0001). • When comparing image quality of 3D MRCPs with and without deep learning reconstruction, deep learning reconstruction significantly improved signal-to-noise ratio and contrast-to-noise ratio (p < 0.05). • IPMN distribution accuracies of parallel imaging with and without deep learning reconstruction (with vs. without: 88.0% vs. 88.0%) and multiple k-space data acquisitions for each TR with deep learning reconstruction (86.0%) were significantly higher than those of others (p < 0.05).


Asunto(s)
Aprendizaje Profundo , Neoplasias Intraductales Pancreáticas , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Estudios Retrospectivos , Relación Señal-Ruido
9.
J Org Chem ; 87(3): 1641-1660, 2022 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-34082529

RESUMEN

We studied the Z/E preference of N-phenylthioacetamide (thioacetanilide) derivatives in various solvents by means of 1H NMR spectroscopy, as well as molecular dynamics (MD) and other computational analyses. Our experimental results indicate that the Z/E isomer preference of secondary (NH)thioamides of N-phenylthioacetamides shows substantial solvent dependency, whereas the corresponding amides do not show solvent dependency of the Z/E isomer ratios. Detailed study of the solvent effects based on molecular dynamics simulations revealed that there are two main modes of hydrogen (H)-bond formation between solvent and (NH)thioacetamide, which influence the Z/E isomer preference of (NH)thioamides. DFT calculations of NH-thioamide in the presence of one or two explicit solvent molecules in the continuum solvent model can effectively mimic the solvation by multiple solvent molecules surrounding the thioamide in MD simulations and shed light on the precise nature of the interactions between thioamide and solvent. Orbital interaction analysis showed that, counterintuitively, the Z/E preference of NH-thioacetamides is mainly determined by steric repulsion, while that of sterically congested N-methylthioacetamides is mainly determined by thioamide conjugation.


Asunto(s)
Simulación de Dinámica Molecular , Tioamidas , Enlace de Hidrógeno , Espectroscopía de Resonancia Magnética , Solventes/química , Tioamidas/química
10.
Acta Med Okayama ; 76(5): 511-517, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36352797

RESUMEN

Iterative reconstruction (IR) improves image quality compared with filtered back projection (FBP). This study investigated the usefulness of model-based IR (forward-projected model-based iterative reconstruction solution [FIRST]) in comparison with FBP and hybrid IR (adaptive iterative dose reduction three-dimensional processing [AIDR 3D]) in low-dose paranasal CT. Twenty-four patients with paranasal sinusitis who underwent standard-dose CT (120 kV) and low-dose CT (100 kV) scanning before and after medical treatment were enrolled. Standard-dose CT scans were reconstructed with FBP (FBP120), and low-dose CT scans with FBP (FBP100), AIDR 3D, and FIRST. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in three anatomical structures and effective doses were compared using Mann-Whitney U test. Two radiologists independently evaluated the visibility of 16 anatomical structures, overall image quality, and artifacts. Effective doses in lowdose CT were significantly reduced compared with those in standard-dose CT (0.24 vs 0.43 mSv, p<0.001). FIRST achieved significantly higher SNR (p<0.01, respectively) and CNR (p<0.001, respectively) of evaluated structures and significant improvement in overall image quality (p<0.001), artifacts (p<0.001), and visibility related to muscles (p<0.05) compared to FBP120, FBP100, and AIDR 3D. FIRST allowed radiation-dose reduction, while maintaining objective and subjective image quality in low-dose paranasal CT.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Relación Señal-Ruido , Artefactos , Algoritmos
11.
Medicina (Kaunas) ; 58(10)2022 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-36295553

RESUMEN

Background and objectives: Acute cholecystitis causes acute abdominal pain and may necessitate emergency surgery or intensive antibiotic therapy and percutaneous drainage, depending on the patient's condition. The symptoms of acute cholecystitis in older patients may be atypical and difficult to diagnose, causing delayed treatment. Clarifying the risk factors for delayed diagnosis among older patients could lead to early diagnosis and treatment of acute cholecystitis. This study aimed to explore the risk factors for delayed diagnosis of acute cholecystitis among rural older patients. Material and Methods: This retrospective cohort study included patients aged over 65 years diagnosed with acute cholecystitis at a rural community hospital. The primary outcome was the time from symptom onset to acute cholecystitis diagnosis. We reviewed the electronic medical records of patients with acute cholecystitis and investigated whether they were diagnosed and treated for the condition at the time of symptom onset. Results: The average ages of the control and exposure groups were 77.71 years (standard deviation [SD] = 14.62) and 80.13 years (SD = 13.95), respectively. Additionally, 41.7% and 64.1% of the participants in the control and exposure groups, respectively, were men. The logistic regression model revealed that the serum albumin level was significantly related to a time to diagnosis > 3 days (odds ratio = 0.51; 95% confidence interval, 0.28−0.94). Conclusion: Low serum albumin levels are related to delayed diagnosis of cholecystitis and male sex. The presence of abdominal pain and a high body mass index (BMI) may be related to early cholecystitis diagnosis. Clinicians should be concerned about the delay in cholecystitis diagnosis in older female patients with poor nutritional conditions, including low serum albumin levels, a low BMI, vague symptoms, and no abdominal pain.


Asunto(s)
Colecistitis Aguda , Colecistitis , Humanos , Masculino , Femenino , Anciano , Estudios Retrospectivos , Diagnóstico Tardío/efectos adversos , Colecistitis Aguda/diagnóstico , Colecistitis Aguda/etiología , Colecistitis Aguda/cirugía , Colecistitis/complicaciones , Colecistitis/cirugía , Factores de Riesgo , Antibacterianos , Albúmina Sérica , Dolor , Resultado del Tratamiento
12.
Radiographics ; 40(4): 1148-1162, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32442046

RESUMEN

Temporal bone trauma is frequently encountered in the emergency department. Technologic advances have enabled timely acquisition of thin-section images and multiplanar reconstructions such that temporal bone anatomy can be evaluated in great detail, with excellent delineation of fractures. The temporal bone is composed of a myriad of tiny structures, including many fissures and canals, that must be distinguished from true fractures. In addition, injury to important structures may result in serious complications such as hearing loss, dizziness, imbalance, perilymphatic fistula, cerebrospinal fluid leakage, facial nerve paralysis, and vascular injury. Structures that should be examined include the tympanic cavity and tegmen, the ossicular chain, the bony labyrinth, the facial canal, the internal carotid artery, the jugular foramen and venous sinuses, and the intracranial contents. Radiologists should be familiar with the anatomy of the temporal bone and be able to describe any pathologic findings and make suggestions to referring clinicians to guide management and determine the prognosis. The authors describe the typical CT and MRI appearances of temporal bone trauma, entities that mimic this injury and thus must be differentiated, and compulsory points for evaluating clinically relevant associated complications. Instruction is provided for acquiring the diagnostic skills necessary to report suggested injury status, complications, and likely sequelae to clinicians.©RSNA, 2020.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Fracturas Craneales/complicaciones , Fracturas Craneales/diagnóstico por imagen , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/lesiones , Tomografía Computarizada por Rayos X/métodos , Diagnóstico Diferencial , Humanos , Hueso Temporal/anatomía & histología
13.
J Org Chem ; 82(21): 11370-11382, 2017 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-28968504

RESUMEN

The conformational properties of N-acyl azoles (imidazole, pyrazole, and triazole) were examined. The N-2',4',6'-trichlorobenzoyl azoles were stable in methanol at room temperature, and no hydrolyzed products were observed over 7 days in the presence of 5% trifluoroacetic acid or 5% triethylamine in CDCl3. The high stability may be explained by the double-bond amide character caused by the steric hindrance due to the ortho-substituents in the benzoyl group. While specific E-amide preferences were observed in N-acyl pyrazoles/triazoles, the amides of the imidazoles gave a mixture of E and Z. One of the conceivable ideas to rationalize this conformational preference may be repulsive interaction between two sets of lone-pair electrons on the pyrazole 2-nitrogen (nN) and the carbonyl oxygen atoms (nO) in the Z-conformation of N-acyl pyrazoles/triazoles. However, analysis of orbital interactions suggested that in the case of the E-conformation of N-acyl pyrazoles, such electron repulsion is small because of distance. The interbond energy calculations suggested that the Z-conformer is involved in strong vicinal σ-σ repulsion along the amide linkage between the σN1N2 and σC1C2 orbitals in the anti-periplanar arrangement and between the σN1C5 and σC1C2 orbitals in the syn-periplanar arrangement, which lead to the overwhelming E-preference in N-acyl pyrazoles/triazoles. In the case of N-acyl imidazoles, similar vicinal σ-σ repulsions were counterbalanced, leading to a weak preference for the E-conformer over the Z-conformer. The chemically stable and E-preferring N-acyl azoles may be utilized as scaffolds in future drug design.

14.
Org Biomol Chem ; 15(6): 1381-1392, 2017 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-28101542

RESUMEN

Neighboring group participation is defined as the action of a substituent to stabilize a transition state or an intermediate by forming a bond or a partial bond with the reaction center. In addition to the primary interaction with the nearest neighboring group, secondary interactions involving another neighboring group(s) could also occur in principle. Here, we revisit this issue by examining the influence of secondary interactions on the stability and reactivity of the putative iminylium cation intermediates, formed by N-O bond cleavage of 1-tetralone oxime systems. A direct observation of a peri-bromo-iminylium intermediate in solution supported the involvement of iminylium cations and the stabilizing effect of secondary interactions arising from a distal tandem substituent. Both experimental and computational findings support the idea that secondary interactions of a tandem-neighboring group on the primary peri-heteroatom (Br, Cl, and O(Me))-iminylium bonding interaction, i.e., a weak halogen bonding interaction (ester (nitro) oxygen-halogen bonding) and an unprecedented hydrogen bonding interaction between a nitro oxygen atom and a CH3O hydrogen atom, are crucial determinants of the reaction pathway, leading to either overwhelmingly selective syn-migration of the oxime functionality or covalent bond formation under acid-catalyzed Beckmann rearrangement conditions.

15.
J Phys Chem A ; 121(44): 8484-8494, 2017 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-29028337

RESUMEN

The geometries of the two hydroxy groups in 1,2-ethanediol or 2,3-butanediols are more stable in a gauche orientation than those in an anti orientation. This has been generally explained in terms of the gauche effect, which is stabilization due to antiperiplanar electron delocalization between an antibonding orbital of the C-O bond (σCO*) and a bonding orbital of the C-H or C-C bond (σCH or σCC). However, a C-C single bond rotation simultaneously determines the geometries of the six vicinal bonds. Therefore, it is important to understand the effects on conformational stability of other interactions of the bond orbitals adjacent to the rotating C1-C2 bond. Bond model analysis revealed that antiperiplanar bond orbital interactions as a whole contribute to the higher stabilities of hydroxy/hydroxy gauche conformers, where the C-O/C-H or C-O/C-C combination including the σCO*/σCH or σCO*/σCC delocalization is not the dominant interaction stabilizing hydroxy/hydroxy gauche conformers. Rather, our results show that a large destabilization due to the antiperiplanar C-O/C-O combination in hydroxy/hydroxy anti conformers relatively increases the stabilities of hydroxy/hydroxy gauche conformers. This destabilization results mainly from the repulsion between the antiperiplanar bonding orbitals (σCO/σCO), which have a larger overlap compared to the synclinal σCO/σCO combination. The sum of the interbond energies between the vicinal bond orbitals of these 1,2-alkanediols is more advantageous for stability in gauche conformers. In addition, interactions between the gauche-oriented hydroxy groups provide large stabilization energies and the corresponding interactions in anti conformers are negligible. The relative conformational stabilities of 1,2-ethanediol and erythro-2,3-butanediol can be explained by the interactions between the antiperiplanar bond orbitals, between the vicinal bond orbitals, or between the hydroxy groups in addition to the combination of interactions between the vicinal bond orbitals and between the hydroxy groups. In contrast, in threo-2,3-butanediol, differences in the relative stabilities of the three conformers can be understood by the combination of the interactions between the vicinal bond orbitals and between the hydroxy groups.

16.
Cancers (Basel) ; 16(9)2024 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-38730665

RESUMEN

BACKGROUND: Diffusion-weighted images (DWI) obtained by echo-planar imaging (EPI) are frequently degraded by susceptibility artifacts. It has been suggested that DWI obtained by fast advanced spin-echo (FASE) or reconstructed with deep learning reconstruction (DLR) could be useful for image quality improvements. The purpose of this investigation using in vitro and in vivo studies was to determine the influence of sequence difference and of DLR for DWI on image quality, apparent diffusion coefficient (ADC) evaluation, and differentiation of malignant from benign head and neck tumors. METHODS: For the in vitro study, a DWI phantom was scanned by FASE and EPI sequences and reconstructed with and without DLR. Each ADC within the phantom for each DWI was then assessed and correlated for each measured ADC and standard value by Spearman's rank correlation analysis. For the in vivo study, DWIs obtained by EPI and FASE sequences were also obtained for head and neck tumor patients. Signal-to-noise ratio (SNR) and ADC were then determined based on ROI measurements, while SNR of tumors and ADC were compared between all DWI data sets by means of Tukey's Honest Significant Difference test. RESULTS: For the in vitro study, all correlations between measured ADC and standard reference were significant and excellent (0.92 ≤ ρ ≤ 0.99, p < 0.0001). For the in vivo study, the SNR of FASE with DLR was significantly higher than that of FASE without DLR (p = 0.02), while ADC values for benign and malignant tumors showed significant differences between each sequence with and without DLR (p < 0.05). CONCLUSION: In comparison with EPI sequence, FASE sequence and DLR can improve image quality and distortion of DWIs without significantly influencing ADC measurements or differentiation capability of malignant from benign head and neck tumors.

17.
Eur J Radiol ; 171: 111289, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38237523

RESUMEN

PURPOSE: The purpose of this in vivo study was to determine the effect of reverse encoding direction (RDC) on apparent diffusion coefficient (ADC) measurements and its efficacy for improving image quality and diagnostic performance for differentiating malignant from benign tumors on head and neck diffusion-weighted imaging (DWI). METHODS: Forty-eight patients with head and neck tumors underwent DWI with and without RDC and pathological examinations. Their tumors were then divided into two groups: malignant (n = 21) and benign (n = 27). To determine the utility of RDC for DWI, the difference in the deformation ratio (DR) between DWI and T2-weighted images of each tumor was determined for each tumor area. To compare ADC measurement accuracy of DWIs with and without RDC for each patient, ADC values for tumors and spinal cord were determined by using ROI measurements. To compare DR and ADC between two methods, Student's t-tests were performed. Then, ADC values were compared between malignant and benign tumors by Student's t-test on each DWI. Finally, sensitivity, specificity and accuracy were compared by means of McNemar's test. RESULTS: DR of DWI with RDC was significantly smaller than that without RDC (p < 0.0001). There were significant differences in ADC between malignant and benign lesions on each DWI (p < 0.05). However, there were no significant difference of diagnostic accuracy between the two DWIs (p > 0.05). CONCLUSION: RDC can improve image quality and distortion of DWI and may have potential for more accurate ADC evaluation and differentiation of malignant from benign head and neck tumors.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias de Cabeza y Cuello , Humanos , Reproducibilidad de los Resultados , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Cabeza , Cuello , Sensibilidad y Especificidad , Estudios Retrospectivos
18.
Emerg Radiol ; 20(3): 247-50, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23150060

RESUMEN

We report a case of ileal internal hernia through the foramen of Winslow into the lesser sac. Preoperative computed tomography (CT) demonstrated that the herniated ileum, which showed a closed-loop obstruction, was located behind the portal vein, and the vein was subsequently compressed and narrowed by the herniated ileum. We found that similar cases in the literature of Winslow's foramen hernias that caused portal vein compression; however, portal vein narrowing has not been described as a characteristic CT finding. The narrowed portal vein sign could be useful in diagnosing the hernia through the foramen of Winslow.


Asunto(s)
Hernia/diagnóstico por imagen , Íleon , Tomografía Computarizada por Rayos X , Anciano , Femenino , Humanos , Enfermedades del Íleon/diagnóstico por imagen , Íleon/diagnóstico por imagen , Obstrucción Intestinal/diagnóstico por imagen , Vena Porta/diagnóstico por imagen , Radiografía Abdominal
19.
Cureus ; 15(4): e38214, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37252465

RESUMEN

Rheumatoid vasculitis (RV) causes various complications in the heart, lungs, kidneys, and nerves that require intensive treatment. Rapid RV-related peripheral nerve involvement progression is critical and requires prompt treatment. We report the case of a 73-year-old female with RV, with a chief complaint of difficulty walking without any infectious symptoms for several months. We diagnosed Guillain-Barré syndrome (GBS) accompanied by RV and treated the patient with intravenous immunoglobulin and cyclophosphamide. Previous impairments of activities of daily living (ADLs) were resolved. Diagnosing the neurological manifestations of RV and GBS in older patients with an active RV is challenging because of the various patterns of the progression. For effective management, considering both diseases and implementing immunosuppressive and modulatory treatments is critical to stop the progression of neurological symptoms and prevent the deterioration of ADLs.

20.
Cureus ; 15(6): e40146, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37425529

RESUMEN

Giant cell arteritis (GCA) causes systemic symptoms; however, involvement of the lungs is relatively rare compared to other rheumatic diseases such as rheumatoid arthritis and systemic sclerosis. Diagnosis and treatment of GCA complicated by chronic lung diseases can be challenging. In this case, an 87-year-old male presented with the chief complaints of systemic muscular pain and cough. The patient was eventually diagnosed with GCA complicated by chronic bronchitis. Although GCA treatment with chronic bronchitis is uncertain, we treated the patient with tapering doses of prednisolone and tocilizumab, which were effective. In older patients with systemic muscular pain and cough, GCA can be considered a differential diagnosis, and tocilizumab can be a reliable treatment in cases complicated by lung diseases, similar to other rheumatic diseases.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda