Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Small ; : e2308857, 2023 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-38072781

RESUMEN

Graphene solution-gated field-effect transistors (gSGFETs) offer high potential for chemical and biochemical sensing applications. Among the current trends to improve this technology, the functionalization processes are gaining relevance for its crucial impact on biosensing performance. Previous efforts are focused on simplifying the attachment procedure from standard multi-step to single-step strategies, but they still suffer from overreaction, and impurity issues and are limited to a particular ligand. Herein, a novel strategy for single-step immobilization of chemically modified aptamers with fluorenylmethyl and acridine moieties, based on a straightforward synthetic route to overcome the aforementioned limitations is presented. This approach is benchmarked versus a standard multi-step strategy using thrombin as detection model. In order to assess the reliability of the functionalization strategies 48-gSGFETs arrays are employed to acquire large datasets with multiple replicas. Graphene surface characterization demonstrates robust and higher efficiency in the chemical coupling of the aptamers with the single-step strategy, while the electrical response evaluation validates the sensing capability, allowing to implement different alternatives for data analysis and reduce the sensing variability. In this work, a new tool capable of overcome the functionalization challenges of graphene surfaces is provided, paving the way toward the standardization of gSGFETs for biosensing purposes.

2.
Nano Lett ; 20(5): 3528-3537, 2020 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-32223249

RESUMEN

Sensor arrays used to detect electrophysiological signals from the brain are paramount in neuroscience. However, the number of sensors that can be interfaced with macroscopic data acquisition systems currently limits their bandwidth. This bottleneck originates in the fact that, typically, sensors are addressed individually, requiring a connection for each of them. Herein, we present the concept of frequency-division multiplexing (FDM) of neural signals by graphene sensors. We demonstrate the high performance of graphene transistors as mixers to perform amplitude modulation (AM) of neural signals in situ, which is used to transmit multiple signals through a shared metal line. This technology eliminates the need for switches, remarkably simplifying the technical complexity of state-of-the-art multiplexed neural probes. Besides, the scalability of FDM graphene neural probes has been thoroughly evaluated and their sensitivity demonstrated in vivo. Using this technology, we envision a new generation of high-count conformal neural probes for high bandwidth brain machine interfaces.


Asunto(s)
Mapeo Encefálico , Interfaces Cerebro-Computador , Encéfalo/diagnóstico por imagen , Grafito , Animales , Ratas
3.
Small ; 16(16): e1906640, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32187840

RESUMEN

Graphene solution-gated field-effect transistors (g-SGFETs) are promising sensing devices to transduce electrochemical potential signals in an electrolyte bath. However, distortion mechanisms in g-SGFET, which can affect signals of large amplitude or high frequency, have not been evaluated. Here, a detailed characterization and modeling of the harmonic distortion and non-ideal frequency response in g-SGFETs is presented. This accurate description of the input-output relation of the g-SGFETs allows to define the voltage- and frequency-dependent transfer functions, which can be used to correct distortions in the transduced signals. The effect of signal distortion and its subsequent calibration are shown for different types of electrophysiological signals, spanning from large amplitude and low frequency cortical spreading depression events to low amplitude and high frequency action potentials. The thorough description of the distortion mechanisms presented in this article demonstrates that g-SGFETs can be used as distortion-free signal transducers not only for neural sensing, but also for a broader range of applications in which g-SGFET sensors are used.


Asunto(s)
Grafito , Neuronas/fisiología , Transistores Electrónicos , Potenciales de Acción , Depresión de Propagación Cortical
4.
Nat Mater ; 18(3): 280-288, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30598536

RESUMEN

Recording infraslow brain signals (<0.1 Hz) with microelectrodes is severely hampered by current microelectrode materials, primarily due to limitations resulting from voltage drift and high electrode impedance. Hence, most recording systems include high-pass filters that solve saturation issues but come hand in hand with loss of physiological and pathological information. In this work, we use flexible epicortical and intracortical arrays of graphene solution-gated field-effect transistors (gSGFETs) to map cortical spreading depression in rats and demonstrate that gSGFETs are able to record, with high fidelity, infraslow signals together with signals in the typical local field potential bandwidth. The wide recording bandwidth results from the direct field-effect coupling of the active transistor, in contrast to standard passive electrodes, as well as from the electrochemical inertness of graphene. Taking advantage of such functionality, we envision broad applications of gSGFET technology for monitoring infraslow brain activity both in research and in the clinic.


Asunto(s)
Mapeo Encefálico/instrumentación , Lóbulo Frontal/fisiología , Grafito , Microtecnología/instrumentación , Transistores Electrónicos , Animales , Grafito/química , Microelectrodos , Modelos Moleculares , Conformación Molecular , Ratas
5.
Cereb Cortex ; 29(1): 319-335, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-29190336

RESUMEN

Cortical slow oscillations (SO) of neural activity spontaneously emerge and propagate during deep sleep and anesthesia and are also expressed in isolated brain slices and cortical slabs. We lack full understanding of how SO integrate the different structural levels underlying local excitability of cell assemblies and their mutual interaction. Here, we focus on ongoing slow waves (SWs) in cortical slices reconstructed from a 16-electrode array designed to probe the neuronal activity at multiple spatial scales. In spite of the variable propagation patterns observed, we reproducibly found a smooth strip of loci leading the SW fronts, overlapping cortical layers 4 and 5, along which Up states were the longest and displayed the highest firing rate. Propagation modes were uncorrelated in time, signaling a memoryless generation of SWs. All these features could be modeled by a multimodular large-scale network of spiking neurons with a specific balance between local and intermodular connectivity. Modules work as relaxation oscillators with a weakly stable Down state and a peak of local excitability to model layers 4 and 5. These conditions allow for both optimal sensitivity to the network structure and richness of propagation modes, both of which are potential substrates for dynamic flexibility in more general contexts.


Asunto(s)
Potenciales de Acción/fisiología , Ondas Encefálicas/fisiología , Corteza Visual/citología , Corteza Visual/fisiología , Animales , Hurones , Masculino , Neuronas/fisiología , Técnicas de Cultivo de Órganos
6.
Sensors (Basel) ; 19(21)2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31683828

RESUMEN

A novel sensing device for simultaneous dissolved oxygen (DO) and pH monitoring specially designed for biofilm profiling is presented in this work. This device enabled the recording of instantaneous DO and pH dynamic profiles within biofilms, improving the tools available for the study and the characterization of biological systems. The microsensor consisted of two parallel arrays of microelectrodes. Microelectrodes used for DO sensing were bare gold electrodes, while microelectrodes used for pH sensing were platinum-based electrodes modified using electrodeposited iridium oxide. The device was fabricated with a polyimide (Kapton®) film of 127 µm as a substrate for minimizing the damage caused on the biofilm structure during its insertion. The electrodes were covered with a Nafion® layer to increase sensor stability and repeatability and to avoid electrode surface fouling. DO microelectrodes showed a linear response in the range 0-8 mg L-1, a detection limit of 0.05 mg L-1, and a sensitivity of 2.06 nA L mg-1. pH electrodes showed a linear super-Nernstian response (74.2 ± 0.7 mV/pH unit) in a wide pH range (pH 4-9). The multi-analyte sensor array was validated in a flat plate bioreactor where simultaneous and instantaneous pH and DO profiles within a sulfide oxidizing biofilm were recorded. The electrodes spatial resolution, the monitoring sensitivity, and the minimally invasive features exhibited by the proposed microsensor improved biofilm monitoring performance, enabling the quantification of mass transfer resistances and the assessment of biological activity.


Asunto(s)
Biopelículas , Electroquímica/instrumentación , Diseño de Equipo , Oxígeno/análisis , Galvanoplastia , Concentración de Iones de Hidrógeno , Microelectrodos , Platino (Metal)/química , Reproducibilidad de los Resultados , Solubilidad
7.
Biotechnol Bioeng ; 115(6): 1604-1613, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29460274

RESUMEN

Transepithelial electrical measurements in the renal tubule have provided a better understanding of how kidney regulates electrolyte and water homeostasis through the reabsorption of molecules and ions (e.g., H2 O and NaCl). While experiments and measurement techniques using native tissue are difficult to prepare and to reproduce, cell cultures conducted largely with the Ussing chamber lack the effect of fluid shear stress which is a key physiological stimulus in the renal tubule. To overcome these limitations, we present a modular perfusion chamber for long-term culture of renal epithelial cells under flow that allows the continuous and simultaneous monitoring of both transepithelial electrical parameters and transepithelial NaCl transport. The latter is obtained from electrical conductivity measurements since Na+ and Cl- are the ions that contribute most to the electrical conductivity of a standard physiological solution. The system was validated with epithelial monolayers of raTAL and NRK-52E cells that were characterized electrophysiologically for 5 days under different flow conditions (i.e., apical perfusion, basal, or both). In addition, apical to basal chemical gradients of NaCl (140/70 and 70/140 mM) were imposed in order to demonstrate the feasibility of this methodology for quantifying and monitoring in real time the transepithelial reabsorption of NaCl, which is a primary function of the renal tubule.


Asunto(s)
Técnicas Citológicas/métodos , Células Epiteliales/metabolismo , Túbulos Renales/metabolismo , Cloruro de Sodio/metabolismo , Animales , Transporte Biológico , Línea Celular , Técnicas Citológicas/instrumentación , Modelos Biológicos , Ratas
8.
Biotechnol Bioeng ; 115(10): 2585-2594, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29940068

RESUMEN

Maintenance of the complex phenotype of primary hepatocytes in vitro represents a limitation for developing liver support systems and reliable tools for biomedical research and drug screening. We herein aimed at developing a biosystem able to preserve human and rodent hepatocytes phenotype in vitro based on the main characteristics of the liver sinusoid: unique cellular architecture, endothelial biodynamic stimulation, and parenchymal zonation. Primary hepatocytes and liver sinusoidal endothelial cells (LSEC) were isolated from control and cirrhotic human or control rat livers and cultured in conventional in vitro platforms or within our liver-resembling device. Hepatocytes phenotype, function, and response to hepatotoxic drugs were analyzed. Results evidenced that mimicking the in vivo sinusoidal environment within our biosystem, primary human and rat hepatocytes cocultured with functional LSEC maintained morphology and showed high albumin and urea production, enhanced cytochrome P450 family 3 subfamily A member 4 (CYP3A4) activity, and maintained expression of hepatocyte nuclear factor 4 alpha (hnf4α) and transporters, showing delayed hepatocyte dedifferentiation. In addition, differentiated hepatocytes cultured within this liver-resembling device responded to acute treatment with known hepatotoxic drugs significantly different from those seen in conventional culture platforms. In conclusion, this study describes a new bioengineered device that mimics the human sinusoid in vitro, representing a novel method to study liver diseases and toxicology.


Asunto(s)
Capilares , Células Endoteliales , Hepatocitos , Dispositivos Laboratorio en un Chip , Hígado , Animales , Capilares/citología , Capilares/metabolismo , Técnicas de Cocultivo/instrumentación , Técnicas de Cocultivo/métodos , Células Endoteliales/citología , Células Endoteliales/metabolismo , Hepatocitos/citología , Hepatocitos/metabolismo , Humanos , Hígado/irrigación sanguínea , Hígado/citología , Hígado/metabolismo , Masculino , Ratas , Ratas Wistar
9.
Sensors (Basel) ; 14(5): 8718-27, 2014 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-24841249

RESUMEN

The cornea is a very particular tissue due to its transparency and its barrier function as it has to resist against the daily insults of the external environment. In addition, maintenance of this barrier function is of crucial importance to ensure a correct corneal homeostasis. Here, the corneal epithelial permeability has been assessed in vivo by means of non-invasive tetrapolar impedance measurements, taking advantage of the huge impact of the ion fluxes in the passive electrical properties of living tissues. This has been possible by using a flexible sensor based in SU-8 photoresist. In this work, a further analysis focused on the validation of the presented sensor is performed by monitoring the healing process of corneas that were previously wounded. The obtained impedance measurements have been compared with the damaged area observed in corneal fluorescein staining images. The successful results confirm the feasibility of this novel method, as it represents a more sensitive in vivo and non-invasive test to assess low alterations of the epithelial permeability. Then, it could be used as an excellent complement to the fluorescein staining image evaluation.


Asunto(s)
Conductometría/instrumentación , Técnicas de Diagnóstico Oftalmológico/instrumentación , Electrodos , Epitelio Corneal/lesiones , Epitelio Corneal/fisiopatología , Pletismografía de Impedancia/instrumentación , Animales , Conductividad Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Conejos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Biofabrication ; 16(3)2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38574551

RESUMEN

Conventional gut-on-chip (GOC) models typically represent the epithelial layer of the gut tissue, neglecting other important components such as the stromal compartment and the extracellular matrix (ECM) that play crucial roles in maintaining intestinal barrier integrity and function. These models often employ hard, flat porous membranes for cell culture, thus failing to recapitulate the soft environment and complex 3D architecture of the intestinal mucosa. Alternatively, hydrogels have been recently introduced in GOCs as ECM analogs to support the co-culture of intestinal cells inin vivo-like configurations, and thus opening new opportunities in the organ-on-chip field. In this work, we present an innovative GOC device that includes a 3D bioprinted hydrogel channel replicating the intestinal villi architecture containing both the epithelial and stromal compartments of the gut mucosa. The bioprinted hydrogels successfully support both the encapsulation of fibroblasts and their co-culture with intestinal epithelial cells under physiological flow conditions. Moreover, we successfully integrated electrodes into the microfluidic system to monitor the barrier formation in real time via transepithelial electrical resistance measurements.


Asunto(s)
Hidrogeles , Dispositivos Laboratorio en un Chip , Impedancia Eléctrica , Células Epiteliales , Electrodos
11.
Nanoscale ; 16(2): 664-677, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38100059

RESUMEN

Graphene-based solution-gated field-effect transistors (gSGFETs) allow the quantification of the brain's full-band signal. Extracellular alternating current (AC) signals include local field potentials (LFP, population activity within a reach of hundreds of micrometers), multiunit activity (MUA), and ultimately single units. Direct current (DC) potentials are slow brain signals with a frequency under 0.1 Hz, and commonly filtered out by conventional AC amplifiers. This component conveys information about what has been referred to as "infraslow" activity. We used gSGFET arrays to record full-band patterns from both physiological and pathological activity generated by the cerebral cortex. To this end, we used an in vitro preparation of cerebral cortex that generates spontaneous rhythmic activity, such as that occurring in slow wave sleep. This examination extended to experimentally induced pathological activities, including epileptiform discharges and cortical spreading depression. Validation of recordings obtained via gSGFETs, including both AC and DC components, was accomplished by cross-referencing with well-established technologies, thereby quantifying these components across different activity patterns. We then explored an additional gSGFET potential application, which is the measure of externally induced electric fields such as those used in therapeutic neuromodulation in humans. Finally, we tested the gSGFETs in human cortical slices obtained intrasurgically. In conclusion, this study offers a comprehensive characterization of gSGFETs for brain recordings, with a focus on potential clinical applications of this emerging technology.


Asunto(s)
Grafito , Humanos , Corteza Cerebral , Encéfalo
12.
ACS Sustain Chem Eng ; 12(24): 9133-9143, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38910878

RESUMEN

The persistence of photoresist residues from microfabrication procedures causes significant obstacles in the technological advancement of graphene-based electronic devices. These residues induce undesired chemical doping effects, diminish carrier mobility, and deteriorate the signal-to-noise ratio, making them critical in certain contexts, including sensing and electrical recording applications. In graphene solution-gated field-effect transistors (gSGFETs), the presence of polymer contaminants makes it difficult to perform precise electrical measurements, introducing response variability and calibration challenges. Given the absence of viable short to midterm alternatives to polymer-intensive microfabrication techniques, a postpatterning treatment involving THF and ethanol solvents was evaluated, with ethanol being the most effective, environmentally sustainable, and safe method for residue removal. Employing a comprehensive analysis with XPS, AFM, and Raman spectroscopy, together with electrical characterization, we investigated the influence of residual polymers on graphene surface properties and transistor functionality. Ethanol treatment exhibited a pronounced enhancement in gSGFET performance, as evidenced by a shift in the charge neutrality point and reduced dispersion. This systematic cleaning methodology holds the potential to improve the reproducibility and precision in the manufacturing of graphene devices. Particularly, by using ethanol for residue removal, we align our methodology with the principles of green chemistry, minimizing environmental impact while advancing diverse graphene technology applications.

13.
Nanoscale Horiz ; 9(4): 544-554, 2024 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-38323517

RESUMEN

Current methodology used to investigate how shifts in brain states associated with regional cerebral blood volume (CBV) change in deep brain areas, are limited by either the spatiotemporal resolution of the CBV techniques, and/or compatibility with electrophysiological recordings; particularly in relation to spontaneous brain activity and the study of individual events. Additionally, infraslow brain signals (<0.1 Hz), including spreading depolarisations, DC-shifts and infraslow oscillations (ISO), are poorly captured by traditional AC-coupled electrographic recordings; yet these very slow brain signals can profoundly change CBV. To gain an improved understanding of how infraslow brain signals couple to CBV we present a new method for concurrent CBV with wide bandwidth electrophysiological mapping using simultaneous functional ultrasound imaging (fUS) and graphene-based field effect transistor (gFET) DC-coupled electrophysiological acquisitions. To validate the feasibility of this methodology visually-evoked neurovascular coupling (NVC) responses were examined. gFET recordings are not affected by concurrent fUS imaging, and epidural placement of gFET arrays within the imaging window did not deteriorate fUS signal quality. To examine directly the impact of infra-slow potential shifts on CBV, cortical spreading depolarisations (CSDs) were induced. A biphasic pattern of decreased, followed by increased CBV, propagating throughout the ipsilateral cortex, and a delayed decrease in deeper subcortical brain regions was observed. In a model of acute seizures, CBV oscillations were observed prior to seizure initiation. Individual seizures occurred on the rising phase of both infraslow brain signal and CBV oscillations. When seizures co-occurred with CSDs, CBV responses were larger in amplitude, with delayed CBV decreases in subcortical structures. Overall, our data demonstrate that gFETs are highly compatible with fUS and allow concurrent examination of wide bandwidth electrophysiology and CBV. This graphene-enabled technological advance has the potential to improve our understanding of how infraslow brain signals relate to CBV changes in control and pathological brain states.


Asunto(s)
Grafito , Humanos , Encéfalo/diagnóstico por imagen , Convulsiones , Electrofisiología , Circulación Cerebrovascular/fisiología , Ultrasonografía
14.
Nanoscale Horiz ; 9(11): 1948-1961, 2024 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-39229772

RESUMEN

Neuroelectronic prostheses are being developed for restoring vision at the retinal level in patients who have lost their sight due to photoreceptor loss. The core component of these devices is the electrode array, which enables interfacing with retinal neurons. Generating the perception of meaningful images requires high-density microelectrode arrays (MEAs) capable of precisely activating targeted retinal neurons. Achieving this precision necessitates the downscaling of electrodes to micrometer dimensions. However, miniaturization increases electrode impedance, which poses challenges by limiting the amount of current that can be delivered, thereby impairing the electrode's capability for effective neural modulation. Additionally, it elevates noise levels, reducing the signal quality of the recorded neural activity. This report focuses on evaluating reduced graphene oxide (rGO) based devices for interfacing with the retina, showcasing their potential in vision restoration. Our findings reveal low impedance and high charge injection limit for microscale rGO electrodes, confirming their suitability for developing next-generation high-density retinal devices. We successfully demonstrated bidirectional interfacing with cell cultures and explanted retinal tissue, enabling the identification and modulation of multiple cells' activity. Additionally, calcium imaging allowed real-time monitoring of retinal cell dynamics, demonstrating a significant reduction in activated areas with small-sized electrodes. Overall, this study lays the groundwork for developing advanced rGO-based MEAs for high-acuity visual prostheses.


Asunto(s)
Grafito , Microelectrodos , Retina , Grafito/química , Animales , Retina/diagnóstico por imagen , Prótesis Visuales , Humanos , Ratones , Impedancia Eléctrica
15.
Nat Nanotechnol ; 19(4): 514-523, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38212522

RESUMEN

One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm-2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.


Asunto(s)
Grafito , Nanoporos , Ratas , Animales , Microelectrodos , Prótesis e Implantes , Estimulación Eléctrica
16.
Lab Chip ; 23(7): 1825-1834, 2023 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-36810654

RESUMEN

Organs-on-a-chip (OoC) are cell culture platforms that replicate key functional units of tissues in vitro. Barrier integrity and permeability evaluation are of utmost importance when studying barrier-forming tissues. Impedance spectroscopy is a powerful tool and is widely used to monitor barrier permeability and integrity in real-time. However, data comparison across devices is misleading due to the generation of a non-homogenous field across the tissue barrier, making impedance data normalization very challenging. In this work, we address this issue by integrating PEDOT:PSS electrodes for barrier function monitoring with impedance spectroscopy. The semitransparent PEDOT:PSS electrodes cover the entire cell culture membrane providing a homogenous electric field across the entire membrane making the cell culture area equally accountable to the measured impedance. To the best of our knowledge, PEDOT:PSS has never been used solely to monitor the impedance of cellular barriers while enabling optical inspection in the OoC. The performance of the device is demonstrated by lining the device with intestinal cells where we monitored barrier formation under flow conditions, as well as barrier disruption and recovery under exposure to a permeability enhancer. The barrier tightness and integrity, and the intercellular cleft have been evaluated by analyzing the full impedance spectrum. Furthermore, the device is autoclavable paving the way toward more sustainable OoC options.


Asunto(s)
Técnicas de Cultivo de Célula , Sistemas Microfisiológicos , Electrodos , Impedancia Eléctrica , Espectroscopía Dieléctrica
17.
Lab Chip ; 23(7): 1954, 2023 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-36881018

RESUMEN

Correction for 'Organ-on-a-chip with integrated semitransparent organic electrodes for barrier function monitoring' by Denise Marrero et al., Lab Chip, 2023, https://doi.org/10.1039/d2lc01097f.

18.
Nanoscale ; 15(41): 16650-16657, 2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37789811

RESUMEN

In the last decade, solution-gated graphene field effect transistors (GFETs) showed their versatility in the development of a miniaturized multiplexed platform for electrophysiological recordings and sensing. Due to their working mechanism, the surface functionalisation and immobilisation of receptors are pivotal to ensure the proper functioning of devices. Herein, we present a controlled covalent functionalisation strategy based on molecular design and electrochemical triggering, which provide a monolayer-like functionalisation of micro-GFET arrays retaining the electronic properties of graphenes. The functionalisation layer as a receptor was then employed as the linker for serotonin aptamer conjugation. The micro-GFET arrays display sensitivity toward the target analyte in the micromolar range in a physiological buffer (PBS 10 mM). The sensor allows the in-flow real-time monitoring of serotonin transient concentrations with fast and reversible responses.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Grafito , Grafito/química , Serotonina , Transistores Electrónicos , Aptámeros de Nucleótidos/química
19.
Nat Nanotechnol ; 17(3): 301-309, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34937934

RESUMEN

Mapping the entire frequency bandwidth of brain electrophysiological signals is of paramount importance for understanding physiological and pathological states. The ability to record simultaneously DC-shifts, infraslow oscillations (<0.1 Hz), typical local field potentials (0.1-80 Hz) and higher frequencies (80-600 Hz) using the same recording site would particularly benefit preclinical epilepsy research and could provide clinical biomarkers for improved seizure onset zone delineation. However, commonly used metal microelectrode technology suffers from instabilities that hamper the high fidelity of DC-coupled recordings, which are needed to access signals of very low frequency. In this study we used flexible graphene depth neural probes (gDNPs), consisting of a linear array of graphene microtransistors, to concurrently record DC-shifts and high-frequency neuronal activity in awake rodents. We show here that gDNPs can reliably record and map with high spatial resolution seizures, pre-ictal DC-shifts and seizure-associated spreading depolarizations together with higher frequencies through the cortical laminae to the hippocampus in a mouse model of chemically induced seizures. Moreover, we demonstrate the functionality of chronically implanted devices over 10 weeks by recording with high fidelity spontaneous spike-wave discharges and associated infraslow oscillations in a rat model of absence epilepsy. Altogether, our work highlights the suitability of this technology for in vivo electrophysiology research, and in particular epilepsy research, by allowing stable and chronic DC-coupled recordings.


Asunto(s)
Epilepsia , Grafito , Animales , Electroencefalografía , Ratones , Microelectrodos , Ratas , Convulsiones
20.
Biosens Bioelectron ; 181: 113156, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33761417

RESUMEN

Over the last few years, the intestine has been extensively studied using in vitro microfluidic systems, commonly known as gut-on-a-chip (GOC) devices. This interest has been due not only to the importance of the intestine's proper functions but also to the relationship that this organ and the microbiota that inhabits it has with the rest of the body's organs. The increased complexity of these in vitro systems, together with the need to improve our understanding of intestinal physiology interdependencies, has led to greater focus on the integration of biosensors within these devices. However, the current number of GOC devices with integrated sensors for monitoring relevant physiological parameters are very limited and demand the use of external analytical techniques that delay the analysis and prevent real-time decision-making. This paper reviews the various materials, technologies, and structures that have been used both for mimicking the physiology of the intestine and monitoring relevant physiological parameters, such as permeability of the gut barrier, dissolved oxygen concentration, cytokines profile and the production of microbial short-chain fatty acids. We also propose alternative biosensing techniques demonstrated in other in vitro and lab-on-a-chip devices that could be translated to GOC models. A critical analysis of the requirements, limitations, and current challenges on the microenvironment replication and monitorization of GOC models is included, with a particular focus on the physiological parameters and biomarkers that should be detected simultaneously in real-time to get a proper framework of the gut function that until now, have not received the necessary attention.


Asunto(s)
Técnicas Biosensibles , Dispositivos Laboratorio en un Chip , Humanos , Intestinos , Microfluídica , Análisis de Secuencia por Matrices de Oligonucleótidos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda