Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Radiologe ; 60(10): 927-933, 2020 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-32809036

RESUMEN

CLINICAL/METHODOLOGICAL ISSUE: COVID-19 is a new viral disease that is associated with inflammatory pulmonary changes which can be detected in computed tomography (CT). So far postmortem CT (PMCT) has not been used as a screening instrument for the evaluation of deaths with and without autopsy. In this respect, its validity has to be proved in comparison to clinical-radiological experiences. STANDARD RADIOLOGICAL METHODS: Postmortem CT METHODICAL INNOVATIONS: So far, PMCT can be regarded as a methodological innovation that has not yet been sufficiently evaluated for pneumonia. PERFORMANCE: CT in clinical routine has a high sensitivity for pneumonia. However, to what extent postmortem artifacts are relevant to PMCT still has to be determined. ACHIEVEMENTS: There is still no standard procedure for the postmortem radiological diagnosis of COVID-19 disease. Despite postmortem artifacts, PMCT can provide valuable information about the presence of pneumonia with interstitial character, especially without autopsy. PRACTICAL RECOMMENDATIONS: PMCT is particularly useful in the assessment of suspected cases of COVID-19 pneumonia for morphological assessment in the context of monitoring deaths in the current pandemic situation.


Asunto(s)
Autopsia , Infecciones por Coronavirus , Pandemias , Neumonía Viral , Betacoronavirus , COVID-19 , SARS-CoV-2 , Tomografía Computarizada por Rayos X
2.
Internist (Berl) ; 60(7): 756-760, 2019 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-30980098

RESUMEN

This article reports the case of a 26-year-old male patient with recurrent emesis and headache due to central nervous system tuberculosis. The thoracic computed tomography showed bilateral disseminated pulmonary micronodular infiltrates and a cavern connecting to the bronchial system. The cranial magnetic resonance imaging showed multiple supratentorial and infratentorial microabscesses with concomitant meningitis. Mycobacterium tuberculosis was detected in sputum, bronchoalveolar lavage and cerebrospinal fluid. The patient received first-line antituberculous drug treatment, including streptomycin (instead of ethambutol) and adjuvant prednisolone.


Asunto(s)
Cefalea/etiología , Mycobacterium tuberculosis/aislamiento & purificación , Tuberculosis/diagnóstico , Vómitos/etiología , Adulto , Antituberculosos/uso terapéutico , Lavado Broncoalveolar , Líquido Cefalorraquídeo/microbiología , Etambutol/uso terapéutico , Humanos , Imagen por Resonancia Magnética , Masculino , Esputo/microbiología , Tomografía Computarizada por Rayos X , Tuberculosis/tratamiento farmacológico , Tuberculosis/microbiología
3.
Z Gastroenterol ; 54(9): 1047-53, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27612217

RESUMEN

BACKGROUND/PURPOSE: Endoscopic ultrasound-guided drainage (EUS-GD) of postoperative abdominal fluid collections (POFC) following pancreatic surgery is used as an alternative or complement to percutaneous drainage (PD) procedure. The present single-center retrospective study evaluates its efficacy and safety. METHOD: We included consecutive cases with POFC treated by EUS-GD between September 2009 and November 2014 in our department. Technical success, long-term clinical success, recurrence rate and need for surgery were analyzed. RESULTS: 24 procedures in 20 patients (95 % after pancreatic resection) were assessed. Indications for surgery included tumors/lesions located in the pancreas (15/20), chronic pancreatitis (3/20) and duodenal adenoma not completely resectable endoscopically (2/20). EUS-GD was performed within a median of 30 days (IQR: 8.25) for a median fluid collection size of 72.5 mm (IQR: 46.25), requiring a mean of 1.2 sessions with placement of a mean of 2.1 plastic stents (7 Fr/10 Fr) per patient for a mean of 89 days (IQR: 127). Microbiology of aspirated fluid revealed positive cultures in 13 patients, mostly polymicrobial, isolated positive for fungal and 3 multidrug-resistant gram negative (MRGN) in 4 cases. An additional transpapillary drainage was inserted in 1/20 patients. 4/20 patients received PD, mostly before EUS-GD. Technical and clinical success was achieved in 20/20 (100 %) and 18/20 (90 %) patients, respectively, while 2 patients required re-operation. During follow-up (median 630 days after stent removal, range: 45 - 2160), recurrence occurred in 1/18 (5.5 %) patient that was referred for surgery. No death or severe adverse events were noted. CONCLUSION: EUS-GD is an effective, minimally invasive and safe method for therapy of POFC after pancreatic surgery offering long-term remission in about 95 % of cases.


Asunto(s)
Ascitis/mortalidad , Ascitis/cirugía , Drenaje/mortalidad , Endoscopía/estadística & datos numéricos , Pancreatectomía/mortalidad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/cirugía , Causalidad , Comorbilidad , Drenaje/estadística & datos numéricos , Endoscopía/mortalidad , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Pancreatectomía/estadística & datos numéricos , Cuidados Posoperatorios , Prevalencia , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento , Ultrasonografía Intervencional
4.
Clin Biomech (Bristol, Avon) ; 107: 106015, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37321163

RESUMEN

BACKGROUND: Totally implantable central venous access port devices are crucial for intravenous application of chemotherapeutics and long-term therapy for chronic disease. Common complications include thrombosis and device fracture related to altered material properties through exposure in situ. This study exhibits whether uniaxial tensile properties (DIN 10555-3) of in vivo used catheters prove inferior to unused catheters. MATERIAL AND METHODS: 5 unused, originally packed silicone catheters were cut into 6 segments of 50 mm: 3 segments each were cleaned via cleaning solution (n = 15) while 3 segments were left unattended (n = 15). Distal segments (50 mm) of long-term in vivo used silicone catheters were cleaned before testing (n = 33). Overall mechanical behavior was tested in a custom-made self-centering, torsion free carrier. Maximum force stress at failure, strain at failure and Young's modulus were determined and statistically analyzed. FINDINGS: Unused catheters showed no significant difference in testing. in vivo used catheters exhibited 20% lower maximal force than unused catheters (p < 0.001), strain at break (p ã€ˆ0,001), and 7% higher elastic modulus (p = 0.004; power: 0.845). Due to a constant cross section area, stress at failure was proportional to maximum force (p < 0.001). Relation between determined parameters and dwell times was non-significant. INTERPRETATION: In vivo long-term used silicone catheters showed significantly lower ultimate strength than unused ones. It is likely that in situ altering changes the mechanical properties of catheters and may potentially lead to failure.


Asunto(s)
Fenómenos Mecánicos , Siliconas , Humanos , Módulo de Elasticidad , Catéteres
5.
Eur Radiol ; 22(10): 2229-36, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22585406

RESUMEN

OBJECTIVES: To prove the feasibility of using Hounsfield attenuation values at MDCT to detect bone bruises related to sacral insufficiency fractures. METHODS: Twenty-two patients with acute sacrum trauma and no fracture findings at MDCT were included in our prospective study. Two observers independently reviewed CTs regarding visual signs of bone bruises in 132 defined regions of the sacral alae. Interobserver agreement was tested by κ statistics. Subsequently, HU values were obtained in the same regions, and attenuation differences between the two sides were calculated. Validity and reliability were assessed by intraclass correlation coefficient and Bland-Altman analysis. HU differences were subjected to ROC curve analysis to determine sensitivity, specificity, PPV and NPV. MRI served as standard reference. RESULTS: MRI revealed 19 regions with bone bruises and associated sacral insufficiency fractures. HU measurements demonstrated good validity and reliability (r = 0.989). ROC curve analysis exhibited an ideal cutoff value of 35.7 HU density difference between affected and non-affected regions. Visual evaluation revealed moderate agreement (κ = 0.48); diagnostic accuracy was inferior to objective evaluation. CONCLUSIONS: Assessment of differences in bone marrow density by HU measurements is an objective and reliable tool for detection of bone bruises associated with occult sacral insufficiency fractures. KEY POINTS : • Bone bruising is associated with occult sacral insufficiency fractures. • Assessment of differences in bone marrow CT attenuation appears valid and reliable. • Comparative HU measurements of bone marrow allow detection of bone bruises. • Comparative HU measurements have high specificity and negative predictive values. • Comparative HU measurements may make further diagnostic workup with MRI unnecessary.


Asunto(s)
Médula Ósea/diagnóstico por imagen , Fracturas Cerradas/diagnóstico por imagen , Fracturas por Estrés/diagnóstico por imagen , Sacro/lesiones , Fracturas de la Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Fracturas Cerradas/diagnóstico , Fracturas por Estrés/diagnóstico , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Fracturas de la Columna Vertebral/diagnóstico
6.
Sci Rep ; 10(1): 7480, 2020 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-32366912

RESUMEN

Temperature-resolved magnetic particle imaging (MPI) represents a promising tool for medical imaging applications. In this study an approach based on a single calibration measurement was applied for highlighting the potential of MPI for monitoring of temperatures during thermal ablation of liver tumors. For this purpose, liver tissue and liver tumor phantoms embedding different superparamagnetic iron oxide nanoparticles (SPION) were prepared, locally heated up to 70 °C and recorded with MPI. Optimal temperature MPI SPIONs and a corresponding linear model for temperature calculation were determined. The temporal and spatial temperature distributions were compared with infrared (IR) camera results yielding quantitative agreements with a mean absolute deviation of 1 °C despite mismatches in boundary areas.


Asunto(s)
Hipertermia Inducida , Rayos Infrarrojos , Neoplasias Hepáticas , Nanopartículas de Magnetita , Tomografía Óptica , Animales , Pollos , Hígado , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia
7.
Physiol Meas ; 40(10): 105002, 2019 10 30.
Artículo en Inglés | MEDLINE | ID: mdl-31519009

RESUMEN

OBJECTIVE: Magnetic particle imaging (MPI) is a new, fast 3D imaging technique, which is considered promising for angiographies. As available MPI scanners suffer from restricted spatial resolution and are mostly constructed for small animal imaging, no vessels within one organ have been depicted by MPI, yet. The purpose of this study was to develop an ex vivo organ perfusion system to display vessels within one organ of human size by MPI and to compare the results to an established 3D imaging technique. APPROACH: An ex vivo porcine kidney perfusion system compatible with digital subtraction angiography (DSA), magnetic resonance tomography and MPI was developed. DSA was used to exemplarily prove intact vessel structures under ex vivo perfusion in two organs. Perfusion in nine organs was displayed by the 3D imaging techniques magnetic resonance angiography (MRA) and MPI angiography. All visible vessels in MRA and MPI were counted and their number compared between both techniques. MAIN RESULTS: The ex vivo organ perfusion system allowed us to perform angiographies by DSA, MRA and MPI. With it, organs of human size could be imaged in small animal scanners, which permitted us to depict vessels within one organ by MPI for the first time. In comparison to MRA, 33% of all vessels were visible in MPI, a difference probably caused by restricted spatial resolution in MPI. SIGNIFICANCE: The presented ex vivo organ perfusion system can serve to practically evaluate MPI's potential for angiography in human-sized organs. This is especially relevant as long as available, for angiography-suited MPI scanners still suffer from size and spatial resolution restrictions.


Asunto(s)
Imagenología Tridimensional/métodos , Riñón/irrigación sanguínea , Riñón/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Animales , Humanos , Porcinos
8.
J Mech Behav Biomed Mater ; 82: 183-186, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29605811

RESUMEN

To enable causal analysis of port catheter failure, this study aimed to develop an experimental setup for uniaxial tensile tests that addresses the specific requirements of highly elastic medical catheters; and to quantify parameters of the catheters' mechanical competence with respect to effects of artificial aging. Segments of 6F-polyurethane catheters were tested in their native status, after chemical and after mechanical aging. Tension experiments were performed with a rate of 220 mm/min until catheter failure. Material behavior was analyzed based on load cell measurements of the universal test system and an additional optical distance registration. The Young's modulus, the ultimate stress and the ultimate strain were determined. Chemical aging significantly decreased Young's modulus (84%; p = 0.001) and ultimate stress (83%; p < 0.001), whereas mechanical aged samples demonstrated similar results for the Young's modulus (p = 0.772) and a non-significant rise of ultimate stress (13%; p = 0.128). Ultimate strain did not differ significantly regardless of the pretreatment. The results proof reliability, reproducibility and sensitivity to quantify artificial aging induced variations and also promise to detect deviations in material features caused by long-term clinical usage of catheters.


Asunto(s)
Catéteres de Permanencia , Ensayo de Materiales/métodos , Fenómenos Mecánicos , Fenómenos Biomecánicos , Módulo de Elasticidad , Ensayo de Materiales/instrumentación , Estrés Mecánico , Factores de Tiempo
9.
Rofo ; 179(5): 473-9, 2007 May.
Artículo en Alemán | MEDLINE | ID: mdl-17436181

RESUMEN

PURPOSE: To assess the detectability of single magnetically labeled mesenchymal stem cells (MSC) in-vitro on a clinical 3T MR scanner using a small animal volume coil. MATERIALS AND METHODS: GFP-transfected MSC were magnetically labeled with superparamagnetic iron oxide particles (SPIO) while applying different dosages of iron (56 vs. 560 microg Fe/ml). The cellular iron content was determined with atomic absorption spectrometry (AAS). Single labeled MSC were displayed in a culture flask using MR imaging and microscopy. Special cell phantoms were designed to examine the detection of labeled MSC with MR imaging in a spatial model. A T2*-weighted 3D gradient echo sequence with isotropic spatial resolution of 150 to 500 microm (3) was used for image acquisition. The detection of labeled MSC in the cell phantoms was quantitatively evaluated using an automated image analysis. Statistical analysis was performed with a significance level of p < 0.05. RESULTS: The labeling of MSC yielded a mean cellular iron content of 1.5 +/- 0.17 pg Fe/cell (56 microg Fe/ml) and 8.3 +/- 1.85 pg Fe/cell (560 microg Fe/ml). Examination of the culture flasks showed single magnetically labeled MSC centered in much larger MR signal voids. The detection and quantification of single MSC in cell phantoms were feasible for spatial resolutions of 150 microm and 200 microm. Cells with a lower SPIO content (1.5 +/- 0.17 pg Fe/cell) were detected in 14.2 +/- 4.2 % (150 microm) and 7.7 +/- 3.8 % (200 microm). MSC with a higher cellular SPIO content (8.3 +/- 1.85 pg Fe/cell) revealed significantly higher occurrences at both spatial resolutions with 81.4 +/- 5.8 % (150 microm) and 59.9 +/- 12.4 % (200 microm), respectively. Regarding the spatial resolution (150 vs. 200 microm), significantly different detection rates were determined only for MSC with the higher SPIO content (8.3 +/- 1.85 pg Fe/cell). CONCLUSION: Detection of single magnetically labeled MSC is feasible on a clinical 3T MR scanner with a small animal volume coil at isotropic spatial resolutions of 150 microm and 200 microm. The number of detected cells is influenced by the cellular iron content and the spatial resolution.


Asunto(s)
Medios de Contraste , Óxido Ferrosoférrico , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Células Madre Mesenquimatosas/ultraestructura , Animales , Estudios de Factibilidad , Compuestos Férricos/análisis , Fantasmas de Imagen , Ratas , Ratas Sprague-Dawley , Espectrofotometría Atómica
10.
Rofo ; 179(6): 618-26, 2007 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-17492539

RESUMEN

PURPOSE: In 1960 Gorlin and Goltz defined the nevoid basal cell carcinoma syndrome (NBCCS, Gorlin-Goltz Syndrome) as a syndrome comprising multiple basal cell carcinoma, odontogenic keratocysts, and skeletal anomalies. NBCCS is an autosomal dominantly inherited disease with an estimated prevalence of 1:150,000 and diagnosis of this syndrome is often an accidental finding of radiological investigations. The purpose of this study was to report the varied radiological and dermatological manifestations of our patients affected with NBCCS and to present this rare syndrome as a differential diagnosis of skeletal anomalies. MATERIALS AND METHODS: Between 1994 and 2005 the demographic, clinical, radiological and histological data of 8 patients with NBCCS were retrospectively analyzed. Nevoid basal cell carcinoma syndrome was diagnosed in the event of two major or one major and two minor criteria. The major criteria are more than 2 basal cell carcinoma, odontogenic keratocysts, three or more palmar pits, and calcification of the falx cerebri. RESULTS: Between 1994 and 2005 8 patients (3 females and 5 males) with NBCCS were treated in our departments. The average age at the time of diagnosis of NBCCS was 49.9 years. All patients had a minimum of two major criteria. The major criteria with the most frequency were the basal cell carcinoma (6 patients) and the odontogenic keratocysts (5 patients), followed by the calcification of the falx cerebri and palmoplantar pits (4 patients). There was no gender-related or age-related predilection and only one patient was affected with pain in his fingers which radiologically correlated to small cystic bone lesions ("flame-shaped lucencies"). CONCLUSION: Due to limitations in identification of mutations in the PTCH1 gene, clinical and radiological examination still remains a very important factor in the treatment of patients suffering from NBCCS. The knowledge of the varied skeletal manifestations and constellations is therefore essential and correlates with therapeutic consequences. Often chest, rib, spine, skull, and jaw X-rays show the way. Due to the risk of the development of an associated medulloblastoma, neurological surveillance in 6-month intervals in addition to an annual MRI of the cerebrum up to an age of 7 is strongly recommended.


Asunto(s)
Síndrome del Nevo Basocelular/diagnóstico por imagen , Neoplasias Óseas/diagnóstico por imagen , Carcinoma Basocelular/diagnóstico por imagen , Neoplasias Cutáneas/diagnóstico por imagen , Huesos/anomalías , Humanos , Odontogénesis , Radiografía , Anomalías Cutáneas/diagnóstico por imagen
11.
Eur J Radiol ; 97: 115-118, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29153361

RESUMEN

PURPOSE: Comparison of radiation doses in patients undergoing angiographic bronchial artery embolization (BAE) before and after a noise reduction imaging technology upgrade. METHODS: We performed a retrospective study of 70 patients undergoing BAE. Procedures were performed before (n=32) and after (n=38) the technology upgrade containing additional filters and improved image-processing. Cumulative air kerma (AK), cumulative dose area product (DAP), number of exposure frames, total fluoroscopy time and amount of contrast agent were recorded. Mean values were calculated and compared using two-tailed t-tests. DSA image quality was assessed independently by two blinded readers and compared using the Wilcoxon signed-rank test. RESULTS: Using the new technology resulted in a significant reduction of 59% in DAP (149.2 (103.1-279.1) vs. 54.8 (38.2-100.7) Gy*cm2, p<0.001) and a significant reduction of 60% for AK (1.3 (0.6-1.9) vs. 0.5 (0.3-0.9) Gy, p<0.001) in comparison to procedures before the upgrade. There was no significant difference between the number of exposure frames in both groups (251±181 vs. 254±133 frames, p=0.07), time of fluoroscopy (28.8 (18.5-50.4) vs. 28.1 (23.3-38.7) min, p=0.73), or the amount of contrast agent used (139.5±70.8 vs. 163.1±63.1ml, p=0.11). No significant difference regarding image quality could be detected (3 (2,3) vs. 3 (2-4), p=0.64). CONCLUSIONS: The new angiographic noise reduction technology significantly decreases the radiation dose during bronchial artery embolization without compromising image quality or increasing time of fluoroscopy or contrast volume.


Asunto(s)
Arterias Bronquiales/diagnóstico por imagen , Embolización Terapéutica/métodos , Hemoptisis/terapia , Ruido , Adulto , Anciano , Angiografía/métodos , Femenino , Fluoroscopía/métodos , Hemoptisis/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Estudios Retrospectivos
12.
Phys Med Biol ; 62(9): 3470-3482, 2017 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-28035904

RESUMEN

Magnetic particle imaging (MPI) facilitates the rapid determination of 3D in vivo magnetic nanoparticle distributions. In this work, liver MPI following intravenous injections of ferucarbotran (Resovist®) was studied. The image reconstruction was based on a calibration measurement, the so called system function. The application of an enhanced system function sample reflecting the particle mobility and aggregation status of ferucarbotran resulted in significantly improved image reconstructions. The finding was supported by characterizations of different ferucarbotran compositions with the magnetorelaxometry and magnetic particle spectroscopy technique. For instance, similar results were obtained between ferucarbotran embedded in freeze-dried mannitol sugar and liver tissue harvested after a ferucarbotran injection. In addition, the combination of multiple shifted measurement patches for a joint reconstruction of the MPI data enlarged the field of view and increased the covering of liver MPI on magnetic resonance images noticeably.


Asunto(s)
Medios de Contraste/química , Dextranos/química , Procesamiento de Imagen Asistido por Computador/métodos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Nanopartículas de Magnetita/química , Imagen Molecular/métodos , Animales , Calibración , Medios de Contraste/administración & dosificación , Medios de Contraste/farmacocinética , Dextranos/administración & dosificación , Dextranos/farmacocinética , Hígado/metabolismo , Nanopartículas de Magnetita/administración & dosificación , Ratones , Distribución Tisular
13.
Phys Med Biol ; 61(9): 3279-90, 2016 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-27032447

RESUMEN

The use of superparamagnetic iron oxide nanoparticles (SPIONs) has provided new possibilities in biophysics and biomedical imaging technologies. The magnetization dynamics of SPIONs, which can be influenced by the environment, are of central interest. In this work, different biological SPION environments are used to investigate three different calibration methods for stem cell monitoring in magnetic particle imaging. It is shown that calibrating using SPIONs immobilized via agarose gel or intracellular uptake results in superior stem cell image quality compared to mobile SPIONs in saline. This superior image quality enables more sensitive localization and identification of a significantly smaller number of magnetically labeled stem cells. The results are important for cell tracking and monitoring of future SPION based therapies such as hyperthermia based cancer therapies, targeted drug delivery, or tissue regeneration approaches where it is crucial to image a sufficiently small number of SPIONs interacting with biological matter.


Asunto(s)
Dextranos/química , Diagnóstico por Imagen/métodos , Nanopartículas de Magnetita/química , Nanopartículas/química , Fantasmas de Imagen , Células Madre/citología , Células Madre/fisiología , Medios de Contraste , Humanos , Procesamiento de Imagen Asistido por Computador/métodos
14.
Med Phys ; 43(6): 2884-2893, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27277037

RESUMEN

PURPOSE: Magnetic particle imaging (MPI) is a quantitative imaging modality that allows the distribution of superparamagnetic nanoparticles to be visualized. Compared to other imaging techniques like x-ray radiography, computed tomography (CT), and magnetic resonance imaging (MRI), MPI only provides a signal from the administered tracer, but no additional morphological information, which complicates geometry planning and the interpretation of MP images. The purpose of the authors' study was to develop bimodal fiducial markers that can be visualized by MPI and MRI in order to create MP-MR fusion images. METHODS: A certain arrangement of three bimodal fiducial markers was developed and used in a combined MRI/MPI phantom and also during in vivo experiments in order to investigate its suitability for geometry planning and image fusion. An algorithm for automated marker extraction in both MR and MP images and rigid registration was established. RESULTS: The developed bimodal fiducial markers can be visualized by MRI and MPI and allow for geometry planning as well as automated registration and fusion of MR-MP images. CONCLUSIONS: To date, exact positioning of the object to be imaged within the field of view (FOV) and the assignment of reconstructed MPI signals to corresponding morphological regions has been difficult. The developed bimodal fiducial markers and the automated image registration algorithm help to overcome these difficulties.

15.
Rofo ; 177(8): 1151-63, 2005 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-16021549

RESUMEN

PURPOSE: In vitro evaluation of labeling efficiency of human mesenchymal stem cells (hMSCs) with different types of superparamagnetic iron oxide nanoparticles as well as detection and quantification by MRI at 3T. MATERIAL AND METHODS: hMSCs were incubated for 24 hours with 5 ultrasmall superparamagnetic particles of iron oxide (USPIO) contrast agents (1 : 30 - 1 : 30,000) of different size, coating and core compound: Endorem, Resovist, citric acid coated magnetite cores of 3 nm (CMF3), 7 nm (CMF7) and 12 nm (CoF, core: cobalt ferrite). Iron uptake, intracellular retention, detection and quantification were evaluated with MRI up to 5 weeks after incubation by cytological analysis (Prussian blue), atomic absorption spectrometry and MR relaxometry measurements. RESULTS: An effective labeling of hMSCs was achieved using Resovist, CMF3 and CMF7 with mean iron concentrations of 5.1/1.8, 1.9/1.4 and 1.5/1.0 pg/cell (dilutions 1:30 [933, 2100, 2800 microg Fe/ml]/1 : 300 [93, 210, 280 microg Fe/ml]) compared with 0.58/0.34 and 0.43/0.30 pg/cell (Endorem, CoF, dilution 1 : 30 [400, 4200 microg Fe/ml]/1 : 300 [40, 420 microg Fe/ml] unlabelled control cells: 0.01 pg/cell). Particle uptake correlated with the concentration of USPIO in the incubation medium. Detection of 5 x 10 (4) labelled cells/ml with MRI was possible up to 5 weeks after incubation (Resovist, CMF7 and CMF3). MR relaxometry measurements showed a strong correlation between cellular iron load and R2* (1/T2*), r > 0.78. No changes in cell viability or toxic effects were found. CONCLUSION: Efficiency of labeling hMSCs with USPIOs depends on coating, size and core compound of used particles. Carboxydextran-coated, clinically approved SPIO (Resovist, 50 nm) or ultrasmall citrate-coated particles (< 10 nm) result in an improved cellular uptake. In principle, the long intracellular retention of particles offers the possibility of cell tracking and migration monitoring in MRI.


Asunto(s)
Aumento de la Imagen/métodos , Hierro , Imagen por Resonancia Magnética/métodos , Magnetismo , Células Madre Mesenquimatosas/citología , Óxidos , Células Cultivadas , Medios de Contraste , Dextranos , Óxido Ferrosoférrico , Humanos , Hierro/química , Nanopartículas de Magnetita , Óxidos/química , Tamaño de la Partícula , Sensibilidad y Especificidad , Coloración y Etiquetado/métodos
16.
Rofo ; 177(8): 1084-92, 2005 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-16021540

RESUMEN

PURPOSE: Minimal invasive direct coronary artery bypass grafting (MIDCAB) or off-pump coronary artery bypass grafting (OPCAB) on the beating heart with full or mini-sternotomy are becoming more common in coronary bypass surgery of the left anterior descending (LAD). In the decision, which surgical approach (MIDCAB, OPCAB or conventional surgery with cardiopulmonary bypass) will be best used, knowledge of the anatomical field is of major importance. The aim of the study was to evaluate retrospective ECG-gated 4-row multidetector CT (MDCT) in patients planned for MIDCAB as additional imaging to coronary angiography. MATERIAL AND METHODS: The study included 25 consecutive patients. MSCT was performed as unenhanced (collimation 4 x 2.5 mm) and contrast-enhanced examination (140-170 ml, 300 mg Iodine/ml, collimation 4 x 1 mm). The evaluation included presence of LAD calcifications, distance of LAD and left internal mammarian artery (LIMA), course of LAD and LIMA, the presence or absence of bridging through myocardium or epicardial fat and the presence of pleural fibrosis. The MDCT results were correlated with intra-operative findings. RESULTS: All MDCTs could be assessed with reference to the demands. In 20/25 operations, MDCT had direct influence as to the selection of the surgical approach (11 MIDCAB, 7 OPCAB with mini-sternotomy and 5 with full sternotomy, 2 conventional surgeries). The distance of LAD and LIMA varied from 0.9 to 4.5 cm in MDCT. As to calcifications, 3/25 correlated patients had calcifications and 10 patients had no calcifications in the middle LAD. Seven patients had intraoperative fibrosis of the vessel wall without calcification of the middle LAD, which could not be detected with MDCT. Another 5 patients had single calcified plaques in the middle LAD, 4 of these had a fibrosis of the vessel and 1 had a normal vessel at surgery. In these cases, the anastomosis was done between the calcified plaques. No myocardial bridging was detected by MDCT and at surgery. Bridging of epicardial fat was shown by MDCT and at surgery in 9/25 patients and was excluded in 15 patients. In 1 patient, the LAD seemed to run superficially in MDCT, but was covered with fat as seen during surgery. The course of the LIMA was inconspicuous in all cases, no pleural fibrosis was found. CONCLUSIONS: The 4-row MDCT has proven to be adequate in addition to coronary angiography for preoperative evaluation in patients scheduled for MIDCAB and provides the surgeon with relevant information for the selection of the operative approach.


Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Cuidados Preoperatorios/métodos , Intensificación de Imagen Radiográfica/métodos , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Medios de Contraste , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Cuidados Preoperatorios/instrumentación , Pronóstico , Intensificación de Imagen Radiográfica/instrumentación , Estudios Retrospectivos , Transductores , Resultado del Tratamiento
17.
Rofo ; 187(4): 248-59, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25372159

RESUMEN

UNLABELLED: Hemoptysis can be a life-threatening pulmonary emergency with high mortality, is symptomatic of an underlying severe pulmonary disease and requires immediate diagnosis and treatment. Diagnostically, bronchoscopy, conventional chest x-ray and contrast-enhanced multislice computed tomography (MSCT) with CT angiography (CTA) provide information regarding the underlying pulmonary disease, bleeding site, the vascular anatomy of the bronchial arteries (BA) and extrabronchial branches, as well a basis for planning of endovascular intervention. Therapeutically, bronchial artery embolization (BAE) is a safe and effective technique in the hands of an experienced interventionist with profound knowledge of the BA anatomy and possible pitfalls as well as experience with first-line therapy of recurrent and massive hemoptysis or as an intervention prior to elective surgery. Recurrent episodes of hemoptysis are not uncommon and require a prompt repeat BAE after exclusion of extrabronchial systemic and pulmonary artery bleeding sources. This review article should give an overview of the history, anatomical and pathophysiological basics and the clinical context of hemoptysis and diagnosis, as well as a survey of management, treatment and results of BAE. KEY POINTS: Hemoptyses are life threatening and require urgent diagnostic and therapy. Chest x-ray, bronchoscopy, and contrast-enhanced MSCT with CTA should be carried out before therapeutic bronchial artery embolization (BAE). BAE for the treatment of massive and recurrent hemoptysis is safe and effective. False embolization in spinal branches of BA are the most serious complication of a BAE. Repeatedly BAE refractory cases should undergo elective surgery.


Asunto(s)
Angiografía/métodos , Arterias Bronquiales/diagnóstico por imagen , Embolización Terapéutica/métodos , Hemoptisis/diagnóstico por imagen , Hemoptisis/terapia , Aumento de la Imagen/métodos , Tomografía Computarizada Multidetector/métodos , Tomografía Computarizada por Rayos X/métodos , Conducta Cooperativa , Diagnóstico Diferencial , Urgencias Médicas , Hemoptisis/etiología , Humanos , Comunicación Interdisciplinaria , Recurrencia
18.
Rofo ; 187(5): 347-52, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25962671

RESUMEN

PURPOSE: Magnetic particle imaging (MPI) is a new radiologic imaging modality. For the first time, a commercial preclinical scanner is installed. The goal of this study was to establish a workflow between MPI and magnetic resonance imaging (MRI) scanners for a complete in vivo examination of a mouse and to generate the first co-registered in vivo MR-MP images. MATERIALS AND METHODS: The in vivo examination of five mice were performed on a preclinical MPI scanner and a 7 Tesla preclinical MRI system. MRI measurements were used for anatomical referencing and validation of the injection of superparamagnetic iron oxide (SPIO) particles during a dynamic MPI scan. We extracted MPI data of the injection phase and co-registered it with MRI data. RESULTS: A workflow process for a combined in vivo MRI and MPI examination was established. A successful injection of ferucarbotran was proven in MPI and MRI. MR-MPI co-registration allocated the SPIOs in the inferior vena cava and the heart during and shortly after the injection. CONCLUSION: The acquisition of preclinical MPI and MRI data is feasible and allows the combined analysis of MR-MPI information.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Dextranos , Angiografía por Resonancia Magnética/métodos , Nanopartículas de Magnetita , Imagen Multimodal/métodos , Técnica de Sustracción , Vena Cava Inferior/anatomía & histología , Vena Cava Inferior/fisiología , Animales , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/instrumentación , Ratones , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Flujo de Trabajo
19.
Rofo ; 186(6): 598-605, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24347356

RESUMEN

PURPOSE: To assess liver remnant volume regeneration and maintenance, and complications in the long-time follow-up of donors after living donor liver transplantation using CT and MRI. MATERIALS AND METHODS: 47 donors with a mean age of 33.5 years who donated liver tissue for transplantation and who were available for follow-up imaging were included in this retrospective study. Contrast-enhanced CT and MR studies were acquired for routine follow-up. Two observers evaluated pre- and postoperative images regarding anatomy and pathological findings. Volumes were manually measured on contrast-enhanced images in the portal venous phase, and potential postoperative complications were documented. Pre- and postoperative liver volumes were compared for evaluating liver remnant regeneration. RESULTS: 47 preoperative and 89 follow-up studies covered a period of 22.4 months (range: 1 - 84). After right liver lobe (RLL) donation, the mean liver remnant volume was 522.0 ml (±â€Š144.0; 36.1 %; n = 18), after left lateral section (LLS) donation 1,121.7 ml (±â€Š212.8; 79.9 %; n = 24), and after left liver lobe (LLL) donation 1,181.5 ml (±â€Š279.5; 72.0 %; n = 5). Twelve months after donation, the liver remnant volume were 87.3 % (RLL; ±â€Š11.8; n = 11), 95.0 % (LS; ±â€Š11.6; n = 18), and 80.1 % (LLL; ±â€Š2.0; n = 2 LLL) of the preoperative total liver volume. Rapid initial regeneration and maintenance at 80 % of the preoperative liver volume were observed over the total follow-up period.  Minor postoperative complications were found early in 4 patients. No severe or late complications or mortality occurred. CONCLUSION: Rapid regeneration of liver remnant volumes in all donors and volume maintenance over the long-term follow-up period of up to 84 months without severe or late complications are important observations for assessing the safety of LDLT donors. KEY POINTS: Liver remnant volumes of LDLT donors rapidly regenerated after donation and volumes were maintained over the long-term follow-up period of up to 84 months without severe or late complications.


Asunto(s)
Regeneración Hepática/fisiología , Trasplante de Hígado , Hígado/patología , Donadores Vivos , Imagen por Resonancia Magnética , Complicaciones Posoperatorias/diagnóstico , Tomografía Computarizada por Rayos X , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos/fisiología , Seguridad del Paciente , Adulto Joven
20.
Rofo ; 185(12): 1149-66, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24008761

RESUMEN

Superparamagnetic iron oxide nanoparticles (SPIO) can be used to image physiological processes and anatomical, cellular and molecular changes in diseases. The clinical applications range from the imaging of tumors and metastases in the liver, spleen and bone marrow, the imaging of lymph nodes and the CNS, MRA and perfusion imaging to atherosclerotic plaque and thrombosis imaging. New experimental approaches in molecular imaging describe undirected SPIO trapping (passive targeting) in inflammation, tumors and associated macrophages as well as the directed accumulation of SPIO ligands (active targeting) in tumor endothelia and tumor cells, areas of apoptosis, infarction, inflammation and degeneration in cardiovascular and neurological diseases, in atherosclerotic plaques or thrombi. The labeling of stem or immune cells allows the visualization of cell therapies or transplant rejections. The coupling of SPIO to ligands, radio- and/or chemotherapeutics, embedding in carrier systems or activatable smart sensor probes and their externally controlled focusing (physical targeting) enable molecular tumor therapies or the imaging of metabolic and enzymatic processes. Monodisperse SPIO with defined physicochemical and pharmacodynamic properties may improve SPIO-based MRI in the future and as targeted probes in diagnostic magnetic resonance (DMR) using chip-based µNMR may significantly expand the spectrum of in vitro analysis methods for biomarker, pathogens and tumor cells. Magnetic particle imaging (MPI) as a new imaging modality offers new applications for SPIO in cardiovascular, oncological, cellular and molecular diagnostics and therapy.


Asunto(s)
Óxido Ferrosoférrico/uso terapéutico , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Animales , Materiales Biocompatibles Revestidos , Óxido Ferrosoférrico/efectos adversos , Óxido Ferrosoférrico/farmacocinética , Humanos , Metástasis Linfática/patología , Angiografía por Resonancia Magnética/métodos , Tasa de Depuración Metabólica/fisiología , Imagen Molecular/métodos , Terapia Molecular Dirigida/métodos , Nanopartículas/uso terapéutico , Neoplasias/diagnóstico , Neoplasias/patología , Tamaño de la Partícula , Control de Calidad , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda