Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Arthroplasty ; 39(5): 1191-1198.e2, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38007206

RESUMEN

BACKGROUND: The radiographic assessment of bone morphology impacts implant selection and fixation type in total hip arthroplasty (THA) and is important to minimize the risk of periprosthetic femur fracture (PFF). We utilized a deep-learning algorithm to automate femoral radiographic parameters and determined which automated parameters were associated with early PFF. METHODS: Radiographs from a publicly available database and from patients undergoing primary cementless THA at a high-volume institution (2016 to 2020) were obtained. A U-Net algorithm was trained to segment femoral landmarks for bone morphology parameter automation. Automated parameters were compared against that of a fellowship-trained surgeon and compared in an independent cohort of 100 patients who underwent THA (50 with early PFF and 50 controls matched by femoral component, age, sex, body mass index, and surgical approach). RESULTS: On the independent cohort, the algorithm generated 1,710 unique measurements for 95 images (5% lesser trochanter identification failure) in 22 minutes. Medullary canal width, femoral cortex width, canal flare index, morphological cortical index, canal bone ratio, and canal calcar ratio had good-to-excellent correlation with surgeon measurements (Pearson's correlation coefficient: 0.76 to 0.96). Canal calcar ratios (0.43 ± 0.08 versus 0.40 ± 0.07) and canal bone ratios (0.39 ± 0.06 versus 0.36 ± 0.06) were higher (P < .05) in the PFF cohort when comparing the automated parameters. CONCLUSIONS: Deep-learning automated parameters demonstrated differences in patients who had and did not have early PFF after cementless primary THA. This algorithm has the potential to complement and improve patient-specific PFF risk-prediction tools.

2.
Knee Surg Sports Traumatol Arthrosc ; 31(5): 1635-1643, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36773057

RESUMEN

Deep learning has the potential to be one of the most transformative technologies to impact orthopedic surgery. Substantial innovation in this area has occurred over the past 5 years, but clinically meaningful advancements remain limited by a disconnect between clinical and technical experts. That is, it is likely that few orthopedic surgeons possess both the clinical knowledge necessary to identify orthopedic problems, and the technical knowledge needed to implement deep learning-based solutions. To maximize the utilization of rapidly advancing technologies derived from deep learning models, orthopedic surgeons should understand the steps needed to design, organize, implement, and evaluate a deep learning project and its workflow. Equipping surgeons with this knowledge is the objective of this three-part editorial review. Part I described the processes involved in defining the problem, team building, data acquisition, curation, labeling, and establishing the ground truth. Building on that, this review (Part II) provides guidance on pre-processing and augmenting the data, making use of open-source libraries/toolkits, and selecting the required hardware to implement the pipeline. Special considerations regarding model training and evaluation unique to deep learning models relative to "shallow" machine learning models are also reviewed. Finally, guidance pertaining to the clinical deployment of deep learning models in the real world is provided. As in Part I, the focus is on applications of deep learning for computer vision and imaging.


Asunto(s)
Aprendizaje Profundo , Cirujanos Ortopédicos , Cirujanos , Humanos , Inteligencia Artificial , Aprendizaje Automático
3.
J Arthroplasty ; 38(9): 1892-1899.e1, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36963533

RESUMEN

BACKGROUND: The extent of geographic variation in knee phenotypes remains unclear. The Coronal Plane Alignment of the Knee (CPAK) Classification proposes 9 coronal plane phenotypes based on constitutional limb alignment and joint line obliquity. This systematic review aims to examine differences in the distributions of CPAK types across geographic regions. METHODS: A systematic review of the literature was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies reporting distributions of knee phenotypes according to the CPAK classification for healthy and/or arthritic knees were included. RESULTS: There were 7 studies included, accounting for 5,964 knees in 3,917 subjects. Among healthy knees (n = 1,214), CPAK type II was the most common type in Belgium (39.2%), Taiwan (39.3%), and India (25.6%). Among arthritic knees (n = 2,804), CPAK type I was the most common in France (33.4%), India (58.8%), and Japan (53.8%), whereas CPAK type II was the most common in Australia (32.8%). The proportion of CPAK type I and II knees varied significantly across geographic regions among healthy (P < .01) and arthritic knees (P < .01). CONCLUSION: Significant variation in CPAK distributions exists between countries. Further work is needed to delineate racial and sexual differences in CPAK types, which were not explored in this article. A better understanding of population-level variability in knee phenotypes may enable orthopaedic surgeons to offer a more personalized approach to knee arthroplasty.


Asunto(s)
Osteoartritis de la Rodilla , Tibia , Humanos , Tibia/cirugía , Fémur , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Fenotipo , Estudios Retrospectivos
4.
J Arthroplasty ; 38(7S): S119-S123.e3, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37088223

RESUMEN

BACKGROUND: Total hip arthroplasty (THA) is a safe and effective procedure; however, complications such as dislocation, fracture, and infection still occur. It is still unclear whether the dislocation rate via the posterior approach (PA) is better, equal, or worse than the direct anterior approach. Our aim was to report the primary THA dislocation rate via the PA using enabling technology in a large consecutive series of patients. METHODS: A retrospective cohort of 2,888 primary THAs were reviewed at a single, high-volume, academic institution from January 2018 to September 2021. All patients underwent a THA by 4 fellowship-trained orthopaedic surgeons through the PA with enabling technology. Overall dislocation and readmission rates within 90 days and up to 3 years were analyzed. RESULTS: Of the 2,888 procedures, a total of 39 patients had complications related to the surgery during the 3-year follow-up period. There were 10 patients (0.35%) who experienced a dislocation, with half undergoing surgical revision. Of the 39 patients who experienced complications, 37 (1.3%) were readmitted and 2 underwent revision during their hospital stay. Postoperative periprosthetic fractures were the most common cause for readmission and reoperation at a rate of 0.52% and 0.52%, respectively. CONCLUSION: The dislocation rate of 0.35% is one of the lowest reported rates via the PA at a mean follow up of 2.1 years and is comparable to previously published rates using alternate approaches. Using contemporary THA with enabling technology, the PA is a reliable approach with respect to dislocation and complication rates after primary THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Fracturas Periprotésicas , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Fracturas Periprotésicas/epidemiología , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Reoperación/efectos adversos , Prótesis de Cadera/efectos adversos
5.
J Arthroplasty ; 38(6S): S259-S265.e2, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36791885

RESUMEN

BACKGROUND: Achieving adequate implant fixation is critical to optimize survivorship and postoperative outcomes after revision total knee arthroplasty (rTKA). Three anatomical zones (ie, epiphysis, metaphysis, and diaphysis) have been proposed to assess fixation, but are not well-defined. The purpose of the study was to develop a deep learning workflow capable of automatically delineating rTKA zones and cone placements in a standardized way on postoperative radiographs. METHODS: A total of 235 patients who underwent rTKA were randomly partitioned (6:2:2 training, validation, and testing split), and a U-Net segmentation workflow was developed to delineate rTKA fixation zones and assess revision cone placement on anteroposterior radiographs. Algorithm performance for zone delineation and cone placement were compared against ground truths from a fellowship-trained arthroplasty surgeon using the dice segmentation coefficient and accuracy metrics. RESULTS: On the testing cohort, the algorithm defined zones in 98% of images (8 seconds/image) using anatomical landmarks. The dice segmentation coefficient between the model and surgeon was 0.89 ± 0.08 (interquartile range [IQR]:0.88-0.94) for femoral zones, 0.91 ± 0.08 (IQR: 0.91-0.95) for tibial zones, and 0.90 ± 0.05 (IQR:0.88-0.94) for all zones. Cone identification and zonal cone placement accuracy were 98% and 96%, respectively, for the femur and 96% and 89%, respectively, for the tibia. CONCLUSION: A deep learning algorithm was developed to automatically delineate revision zones and cone placements on postoperative rTKA radiographs in an objective, standardized manner. The performance of the algorithm was validated against a trained surgeon, suggesting that the algorithm demonstrated excellent predictive capabilities in accordance with relevant anatomical landmarks used by arthroplasty surgeons in practice.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Aprendizaje Profundo , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Reoperación , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tibia/cirugía
6.
Eur J Orthop Surg Traumatol ; 32(8): 1459-1468, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34605989

RESUMEN

PURPOSE: Although various papers have reported on the clinical performance of cup retention with cementation of a new liner and bone grafting in the management of well-fixed cups with polyethylene wear and periacetabular osteolysis after total hip arthroplasty (THA), no systematic review of this topic has been published to date. METHODS: Medline, EMBASE and Cochrane Library were searched for articles published from January 1999 to January 2019 using "osteolysis" AND "well-fixed", "osteolysis" AND "retro-acetabular", "bone graft" AND ("retention" OR "retained" OR "stable") AND "cup", and "cemented liner" AND "well-fixed". RESULTS: Nine articles were selected for review (186 cases, 76.1 months mean follow-up). The overall revision rate was 11.3% (21 hips) most commonly due to aseptic loosening (9/186 hips), dislocation (8/186 hips), and liner wear progression (2/186 cases). The reported square size of osteolytic lesions ranged from a mean of 465.84 mm2 to a max of 4,770 mm2. Almost all reported lesions treated with bone grafts resolved or did not progress 97% (72/74). All studies indicated improved pain and functional scores at follow-up. CONCLUSION: Cementation of a new liner with periacetabular bone grafting provides an alternative option to isolated liner exchange and cup revision for the management of periacetabular osteolysis in well-fixed cups with a disrupted locking mechanism or unavailable exchange liner. Further higher quality studies are required in order to examine if the use of highly cross-linked polyethylene, highly porous-coated cups, hydroxyapatite-coated cups, and small-diameter cups influence the clinical outcome of liner cementation in well-fixed cups with periacetabular osteolysis.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Osteólisis , Humanos , Polietileno/uso terapéutico , Cementación , Falla de Prótesis , Diseño de Prótesis , Reoperación , Osteólisis/etiología , Osteólisis/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Acetábulo/cirugía , Metales , Hidroxiapatitas , Estudios de Seguimiento
7.
Eur J Orthop Surg Traumatol ; 31(3): 511-516, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33026564

RESUMEN

INTRODUCTION: The relationship between cervical degenerative pathology and total knee arthroplasty (TKA) revision rates is not well understood. The aim of the study was to determine whether cervical spine degenerative diseases have a role in complications following TKA within 2 years. METHODS: Data were collected from the Humana insurance database using the PearlDiver Patient Records Database from 2007-2017. Patients who had a primary TKA were identified using Current Procedural Terminology (CPT) code 27,447, and patients with degenerative cervical disease were identified using CPT and International Classification of Diseases (ICD) codes. Data on patients' demographics, comorbidities and postoperative complications were recorded and analyzed with univariate and multivariate analysis with significance set at p < 0.05. A Kaplan-Meier analysis was conducted to estimate the 1- and 2-year rates of survival free from revision. RESULTS: A total of 81,873 patients were included in this study. Following multivariate analysis, cervical spine degenerative disease patients were at increased risk of all-cause revision surgery following 1 year (OR: 1.342 95% CI: 1.149-1.569; p < 0.001) and 2 year (OR: 1.338; 95% CI: 1.184-1.512; p < 0.001). At 2 years, patients with cervical spine degenerative disease had a survival rate of 97.7%, while the survival rate was 99.2% among the non-cervical degenerative cohort. CONCLUSIONS: Based on these results, patients with cervical spine degenerative pathology should be counseled that their spinal pathology may impair outcomes following TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Vértebras Cervicales/cirugía , Humanos , Complicaciones Posoperatorias/etiología , Reoperación , Estudios Retrospectivos , Factores de Riesgo
8.
Bone Jt Open ; 5(2): 101-108, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38316146

RESUMEN

Aims: Distal femoral resection in conventional total knee arthroplasty (TKA) utilizes an intramedullary guide to determine coronal alignment, commonly planned for 5° of valgus. However, a standard 5° resection angle may contribute to malalignment in patients with variability in the femoral anatomical and mechanical axis angle. The purpose of the study was to leverage deep learning (DL) to measure the femoral mechanical-anatomical axis angle (FMAA) in a heterogeneous cohort. Methods: Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A DL workflow was created to measure the FMAA and validated against human measurements. To reflect potential intramedullary guide placement during manual TKA, two different FMAAs were calculated either using a line approximating the entire diaphyseal shaft, and a line connecting the apex of the femoral intercondylar sulcus to the centre of the diaphysis. The proportion of FMAAs outside a range of 5.0° (SD 2.0°) was calculated for both definitions, and FMAA was compared using univariate analyses across sex, BMI, knee alignment, and femur length. Results: The algorithm measured 1,078 radiographs at a rate of 12.6 s/image (2,156 unique measurements in 3.8 hours). There was no significant difference or bias between reader and algorithm measurements for the FMAA (p = 0.130 to 0.563). The FMAA was 6.3° (SD 1.0°; 25% outside range of 5.0° (SD 2.0°)) using definition one and 4.6° (SD 1.3°; 13% outside range of 5.0° (SD 2.0°)) using definition two. Differences between males and females were observed using definition two (males more valgus; p < 0.001). Conclusion: We developed a rapid and accurate DL tool to quantify the FMAA. Considerable variation with different measurement approaches for the FMAA supports that patient-specific anatomy and surgeon-dependent technique must be accounted for when correcting for the FMAA using an intramedullary guide. The angle between the mechanical and anatomical axes of the femur fell outside the range of 5.0° (SD 2.0°) for nearly a quarter of patients.

9.
Anal Chem ; 85(13): 6491-6, 2013 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-23758450

RESUMEN

Reagent delivery constitutes a key step for reaction initiation in droplet-in-oil microfluidic platforms. Currently, this function is performed by complete fusion of a reagent droplet with the reactor droplet. The full coalescence, however, constrains the lower limit of volume delivery because reproducible droplet generation becomes exceedingly difficult as the reagent droplet volume is decreased. Here, we demonstrate fractional volume delivery based on partially coalescent and noncoalescent droplet collisions as a new reagent delivery mechanism. A charged reagent droplet is generated by pulsing a flow carrying needle to high voltage. The charged droplet is directed toward a grounded reactor droplet. Upon collision, the reagent droplet inverts its charge and is pulled away from the reactor droplet prior to full fusion, injecting only a fraction of its volume. The undelivered portion of the reagent drop is then merged with a collector droplet. We demonstrate that a wide range of fractional injections (0.003%-56%) can be reproducibly achieved, providing a means for minute volume delivery without small drop generation.


Asunto(s)
Microfluídica/métodos , Aceites/química , Agua/química , Análisis de Inyección de Flujo/métodos , Indicadores y Reactivos/administración & dosificación , Indicadores y Reactivos/química , Aceites/administración & dosificación , Agua/administración & dosificación
10.
Bone Joint J ; 105-B(6): 587-589, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37257860

RESUMEN

The OpenAI chatbot ChatGPT is an artificial intelligence (AI) application that uses state-of-the-art language processing AI. It can perform a vast number of tasks, from writing poetry and explaining complex quantum mechanics, to translating language and writing research articles with a human-like understanding and legitimacy. Since its initial release to the public in November 2022, ChatGPT has garnered considerable attention due to its ability to mimic the patterns of human language, and it has attracted billion-dollar investments from Microsoft and PricewaterhouseCoopers. The scope of ChatGPT and other large language models appears infinite, but there are several important limitations. This editorial provides an introduction to the basic functionality of ChatGPT and other large language models, their current applications and limitations, and the associated implications for clinical practice and research.


Asunto(s)
Inteligencia Artificial , Lenguaje
11.
Hip Int ; 33(4): 705-715, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35658595

RESUMEN

BACKGROUND: A number of papers have been published about the clinical performance of modern rough-blasted titanium Burch-Schneider antiprotrusio cages (BS-APCs) for the treatment of acetabular bone defects. However, no systematic review of the literature has been published to date. METHODS: The US National Library of Medicine (PubMed/MEDLINE), EMBASE, and the Cochrane Database of Systematic Reviews were queried for publications using keywords pertinent to Burch-Schneider antiprotrusio cage, revision THA, and clinical outcomes. RESULTS: 8 articles were found to be suitable for inclusion in the present study in which 374 cases (370 patients) had been treated with modern BS-APCs. Most acetabular bone defects were type 3 according to the Paprosky classification (type 2C: 18.1%, 3A: 51%, and 3B: 28.9%). The overall re-revision rate for the 374 acetabular reconstructions with modern BS-APCs was 11.5% (43 cases). The short-term survival rate of the modern BS-APC construct was 90.6% (339 out of 374 cases), while the mid-term survival rate was 85.6% (320 out of 374 cases), and the long-term survival rate 62% (54 out of 87 cases). The most common reasons for revision were aseptic loosening (5.6%), periprosthetic joint infection (3.8%), dislocation (2.7%), and acetabular periprosthetic fracture (1.9%). CONCLUSIONS: There was moderate quality evidence to show that the use of modern rough blasted titanium BS-APCs in cases of acetabular bone loss has an unacceptably high failure rate (38%). Given that antiprotrusio cages do not provide any biological fixation, we would not recommend the routine use of modern BS-APCs in complex revision THA cases. By contrast, the satisfactory short- to mid-term outcome of modern BS-APCs in combination with their low cost compared to highly porous acetabular implants, make us feel that BS-APCs might still be used in selected elderly or low-demand patients without severe superomedial acetabular bone loss.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Titanio , Falla de Prótesis , Estudios de Seguimiento , Reoperación , Acetábulo/cirugía , Acetábulo/patología , Estudios Retrospectivos
12.
Arthroplast Today ; 19: 101072, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36624748

RESUMEN

Background: Prior investigations of total hip arthroplasty (THA) have studied the effects of prosthetic femoral head size and stem offset on hip range of motion (ROM), impingement risk, and overall hip stability to optimize the return to activities of daily living. However, the relationship between femoral head length and hip ROM, specifically external rotation (ER), has not been evaluated. The aim of our study was to intraoperatively assess how femoral head length affects hip ROM during a posterior approach THA. Methods: Thirty-two patients undergoing a primary elective THA through a posterior approach were prospectively included. After final femoral stem insertion, femoral head trials were performed using the targeted head length, followed by the shorter (-3.0 to -3.5 mm) and longer (+3.0 to +4.0 mm) head length configurations. At each length, hip ER was measured using an intraoperative goniometer from an imageless navigation system. ER values across the three head lengths were compared using a repeated-measures analysis of variance and paired t-tests. Results: Varying femoral head lengths demonstrated a statically significant and reproducible effect on intraoperative ER range (analysis of variance; P < .001) in each patient. An increased femoral head length (mean 3.4 mm) significantly decreased (P < .001) ER range by 10.8 ± 3.3° while a shortened femoral head length (mean 3.5 mm) significantly increased (P < .001) the ER ROM by 6.0 ± 3.8°. Conclusions: The results of this study demonstrate the sensitivity of hip ROM to incremental changes in femoral head length. As ER is important for activities of daily living, inadvertent lengthening should be avoided.

13.
Bone Jt Open ; 3(6): 475-484, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35694779

RESUMEN

AIMS: Navigation devices are designed to improve a surgeon's accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error. METHODS: A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile ([Formula: see text]sacral slope(SS)stand-sit > 30°), or stiff ([Formula: see text]SSstand-sit < 10°) spinopelvic mobility contributed to increased error rates. RESULTS: The paired absolute difference between CAS and postoperative imaging measurements was 2.3° (standard deviation (SD) 2.6°) for inclination and 3.1° (SD 4.2°) for anteversion. Using a target zone of 40° (± 10°) (inclination) and 20° (± 10°) (anteversion), postoperative standing radiographs measured 96% of acetabular components within the target zone for both inclination and anteversion. Multiple logistic regression analysis controlling for BMI and sex revealed that hypermobile spinopelvic mobility significantly increased error rates for anteversion (odds ratio (OR) 2.48, p = 0.009) and inclination (OR 2.44, p = 0.016), whereas stiff spinopelvic mobility increased error rates for anteversion (OR 1.97, p = 0.028). There were no dislocations at a minimum three-year follow-up. CONCLUSION: Despite high reliability in acetabular positioning for inclination in a large patient cohort using an optical CAS system, hypermobile and stiff spinopelvic mobility significantly increased the risk of clinically relevant errors. In patients with abnormal spinopelvic mobility, CAS systems should be adjusted for use to avoid acetabular component misalignment and subsequent risk for long-term dislocation. Cite this article: Bone Jt Open 2022;3(6):475-484.

14.
Bone Jt Open ; 3(10): 767-776, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36196596

RESUMEN

AIMS: Accurate identification of the ankle joint centre is critical for estimating tibial coronal alignment in total knee arthroplasty (TKA). The purpose of the current study was to leverage artificial intelligence (AI) to determine the accuracy and effect of using different radiological anatomical landmarks to quantify mechanical alignment in relation to a traditionally defined radiological ankle centre. METHODS: Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A sub-cohort of 250 radiographs were annotated for landmarks relevant to knee alignment and used to train a deep learning (U-Net) workflow for angle calculation on the entire database. The radiological ankle centre was defined as the midpoint of the superior talus edge/tibial plafond. Knee alignment (hip-knee-ankle angle) was compared against 1) midpoint of the most prominent malleoli points, 2) midpoint of the soft-tissue overlying malleoli, and 3) midpoint of the soft-tissue sulcus above the malleoli. RESULTS: A total of 932 bilateral full-limb radiographs (1,864 knees) were measured at a rate of 20.63 seconds/image. The knee alignment using the radiological ankle centre was accurate against ground truth radiologist measurements (inter-class correlation coefficient (ICC) = 0.99 (0.98 to 0.99)). Compared to the radiological ankle centre, the mean midpoint of the malleoli was 2.3 mm (SD 1.3) lateral and 5.2 mm (SD 2.4) distal, shifting alignment by 0.34o (SD 2.4o) valgus, whereas the midpoint of the soft-tissue sulcus was 4.69 mm (SD 3.55) lateral and 32.4 mm (SD 12.4) proximal, shifting alignment by 0.65o (SD 0.55o) valgus. On the intermalleolar line, measuring a point at 46% (SD 2%) of the intermalleolar width from the medial malleoli (2.38 mm medial adjustment from midpoint) resulted in knee alignment identical to using the radiological ankle centre. CONCLUSION: The current study leveraged AI to create a consistent and objective model that can estimate patient-specific adjustments necessary for optimal landmark usage in extramedullary and computer-guided navigation for tibial coronal alignment to match radiological planning.Cite this article: Bone Jt Open 2022;3(10):767-776.

15.
Bone Joint J ; 104-B(11): 1196-1201, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36317354

RESUMEN

AIMS: Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to ionizing radiation and shorter examination time. The aim of our study was to evaluate femoral stem version in postoperative total hip arthroplasty (THA) patients and compare the accuracy of hipEOS to CT. We hypothesize that there will be no significant difference in calculated femoral stem version measurements between the two imaging methods. METHODS: In this study, 45 patients who underwent THA between February 2016 and February 2020 and had both a postoperative CT and EOS scan were included for evaluation. A fellowship-trained musculoskeletal radiologist and radiological technician measured femoral version for CT and 3D EOS, respectively. Comparison of values for each imaging modality were assessed for statistical significance. RESULTS: Comparison of the mean postoperative femoral stem version measurements between CT and 3D hipEOS showed no significant difference (p = 0.862). In addition, the two version measurements were strongly correlated (r = 0.95; p < 0.001), and the mean paired difference in postoperative femoral version for CT scan and 3D biplanar radiography was -0.09° (95% confidence interval -1.09 to 0.91). Only three stem measurements (6.7%) were considered outliers with a > 5° difference. CONCLUSION: Our study supports the use of low-dose biplanar radiography for the postoperative assessment of femoral stem version after THA, demonstrating high correlation with CT. We found no significant difference for postoperative femoral version when comparing CT to 3D EOS. We believe 3D EOS is a reliable option to measure postoperative femoral version given its advantages of lower radiation dosage and shorter examination time.Cite this article: Bone Joint J 2022;104-B(11):1196-1201.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Imagenología Tridimensional/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Radiografía , Tomografía Computarizada por Rayos X/métodos
16.
J Am Acad Orthop Surg ; 29(24): e1387-e1395, 2021 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-34874337

RESUMEN

INTRODUCTION: Overlapping surgery is defined as two cases occurring in separate operating rooms (ORs), where the same attending surgeon conducts the critical surgical portions of each case at different times. Although it has been suggested that this established practice may improve the utilization of resources, allow for more opportunities to teach surgical trainees, and facilitate timely access to care, there is still no consensus on its use in elective orthopaedic surgery, such as total joint arthroplasty (TJA). METHODS: A systematic review and meta-analysis of the literature was done according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to identify articles investigating the use of overlapping and single operating room TJA. Relevant data, including surgical time, intraoperative complications, postoperative complications, mortality rate, revision rate, and readmission rate, were extracted and recorded. RESULTS: Six articles were included (35,938 patients: 17,677 overlapping and 18,261 nonoverlapping). Overall revision rates were 1.2% and 1.1% for the overlapping and nonoverlapping cohorts, respectively (odds ratio [OR] = 1.19; 95% confidence interval [CI]: 0.93 to 1.53). The overall intraoperative complication rate was 1.6% for both cohorts (OR = 0.98; 95% CI: 0.79 to 1.23), and the overall postoperative orthopaedic complication rates were 2.0% and 1.95% within the overlapping and nonoverlapping OR cohorts, respectively (OR = 1.07; 95% CI: 0.89 to 1.29). The readmission rate was 4.6% in the overlapping group and 4.2% in the nonoverlapping group (OR = 0.88; 95% CI: 0.70 to 1.11). Two studies with comparable groups reported markedly increased surgical time in the overlapping group compared with the nonoverlapping group. DISCUSSION: Overlapping surgery was found to be as safe as nonoverlapping surgery in patients undergoing TJA. Although overlapping TJA surgery is associated with satisfactory short-term revision rates, prolonged follow-up is required to further assess the medium-term and long-term outcomes of overlapping surgery compared with nonoverlapping surgery. Finally, although overlapping TJA surgery might be associated with increased OR time, this difference is not clinically relevant.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Seguridad del Paciente , Artroplastia , Procedimientos Quirúrgicos Electivos , Humanos , Tempo Operativo , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos
17.
J Orthop ; 24: 58-64, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33679029

RESUMEN

PURPOSE: Simultaneous bilateral unicompartmentsl knee arthroplasty (BUKA) is considered safe and effective. We performed a systematic review to assess the postoperative outcomes. METHODS: The US National Library of Medicine (PubMed/MEDLINE), Google Scholar, and the Cochrane Database of Systematic Reviews were queried for publications. RESULTS: Ten articles were included with 765 simultaneous BUKA. Overall complication rate was 7.0%, survivorship was 97.6% at mean 17 months follow-up. No differences were reported between simultaneous and staged BUKA. CONCLUSION: Simultaneous BUKA is as safe as staged BUKA, it is associated with decreased length of stay and operative time, although it has an increased rate of blood transfusion.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda