Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Phys Rev Lett ; 115(23): 231802, 2015 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-26684111

RESUMEN

Borexino is a liquid scintillation detector located deep underground at the Laboratori Nazionali del Gran Sasso (LNGS, Italy). Thanks to the unmatched radio purity of the scintillator, and to the well understood detector response at low energy, a new limit on the stability of the electron for decay into a neutrino and a single monoenergetic photon was obtained. This new bound, τ≥6.6×10^{28} yr at 90% C.L., is 2 orders of magnitude better than the previous limit.

2.
J Anal Toxicol ; 17(1): 34-7, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8429625

RESUMEN

A simple and rapid method is described for the determination of 2-mercaptobenzothiazole and mercaptobenzothiazole disulfide leached from rubber closures into the iodinated contrast medium (sodium iothalamate). The contaminants were extracted with methylene chloride and analyzed by high-performance liquid chromatography using ultraviolet detection at wavelengths of 272 and 328 nm. The structures of the impurities were confirmed unequivocally by mass spectrometry. The minimum detectable level was 1 microgram/100 mL (0.01 ppm). The quantitation of contaminants leached from rubber stoppers provides a means for evaluating possible health risks of the extractables.


Asunto(s)
Cromatografía Líquida de Alta Presión , Contaminación de Medicamentos , Ácido Yotalámico , Tiazoles/análisis , Benzotiazoles , Espectrometría de Masas , Goma
4.
Analyst ; 114(5): 567-9, 1989 May.
Artículo en Inglés | MEDLINE | ID: mdl-2757227

RESUMEN

Low levels of airborne ethyl 2-cyanoacrylate (ECA) were monitored by drawing air through sampling tubes containing Tenax GC. After desorption with acetone, ECA was quantified by gas chromatography using a thermionic specific detector in the nitrogen mode. Polymerised ECA was shown to yield ECA monomer under the conditions of gas chromatographic analysis.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Cianoacrilatos/análisis , Adhesivos , Cromatografía de Gases
5.
Analyst ; 117(9): 1417-20, 1992 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-1443639

RESUMEN

A highly sensitive and specific gas chromatographic-mass spectrometric (GC-MS) assay for the determination of 4,4'-methylenebis(2-chloroaniline) (MBOCA) in urine is reported. It is based on the solvent extraction of the hydrolysed MBOCA conjugates, together with deuterium-labelled benzidine-d8 added as an internal standard, and a two-phase derivatization procedure involving use of pentafluoropropionic anhydride in the presence of ammonia as the phase-transfer catalyst. The reaction is complete within 2 min at room temperature. The pentafluoropropyl derivatives are determined by use of capillary column GC-MS with selected-ion monitoring in the negative ion chemical ionization mode. The lower limit of detection for MBOCA was 1 microgram dm-3 and the calibration graph showed linearity between 10 and 250 micrograms dm-3. The recovery of the analyte added to pooled urine was above 86%. Thirty urine specimens from workers employed in a polyurethane-producing plant were analysed for MBOCA by this method.


Asunto(s)
Metilenobis (cloroanilina)/análisis , Adulto , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Orina/química
6.
Analyst ; 115(7): 925-8, 1990 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-2221399

RESUMEN

A sampling and analytical procedure was developed for the monitoring of airborne 2-methylaziridine (MA). The analyte is collected by drawing air through a solution of 2,4,6-trinitrobenzenesulphonic acid (TNBS). In situ derivatisation of MA with TNBS during sample collection provides stability to the highly reactive analyte and makes it amenable to a sensitive high-performance liquid chromatographic determination with ultraviolet detection. The purified synthetic derivative of MA with TNBS is more suitable as a calibration standard than commercially available MA.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Aziridinas/análisis
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda