Orbit ; 40(1): 9-17, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31931650

RESUMEN

Purpose: To evaluate the accuracy and interobserver variability of three-dimensional (3D) stereophotogrammetric imaging for volumetric assessment in the periorbital region and to propose a protocol for measurement. Methods: A cross-sectional study was performed. Fifty-eight normal adult subjects had photographs taken using the VECTRA M3 imaging system on two separate occasions at a single center teaching hospital. The primary study outcome measurement was mean volume change in the periorbital region, using different methods of image analysis with the following variables: registration method, eyes open or closed, eyelids measured separately or together, extension of area measured to include mid-face. Accuracy was defined as the agreement between paired images with no measured change in volume (0 mL). The agreement between two independent observers was assessed using Bland-Altman plots. Results: There was a statistically significant difference (P < .0001) between the different methods of measurement, with registration of images having the most effect (partial eta squared 0.229). A mean change in volume of 0.11 ± 0.13 mL was reported for the most accurate method. Agreement between observers was confirmed (highest Intraclass Correlation Coefficient 0.63). Conclusions: Assessment of volumetric change in the periorbital region using 3D image reconstruction is accurate with good interobserver repeatability and is suitable for clinical use. A protocol for data acquisition using the VECTRA M3 is proposed. 3D image reconstruction holds promise to enable diagnosis, treatment monitoring, and surgical outcome evaluation in ocular adnexal disease.


Asunto(s)
Cara , Imagenología Tridimensional , Adulto , Estudios Transversales , Párpados/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
2.
Orbit ; 36(5): 298-300, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28812923

RESUMEN

The treatment of midfacial tumours with radiotherapy, chemotherapy and radio-iodine can cause nasolacrimal duct fibrosis resulting in epiphora. Nasolacrimal patency can be maintained by stenting. We report our experience of prophylatic Nunchaku stent insertion in 5 patients prior to midfacial radiotherapy. Four out of 5 patients (80%) had patent nasolacrimal ducts without any symptoms of epiphora following removal of the stents. One patient was initially asymptomatic with patent nasolacrimal duct, but subsequently developed epiphora. Nunchaku stents may provide a simple and effective way of preventing epiphora, obviate the need for nasal retrieval that is required for other nasolacrimal stents, and reduce the risk of requiring further lacrimal surgery.


Asunto(s)
Anomalías Inducidas por Radiación/prevención & control , Carcinoma de Células Escamosas/radioterapia , Neoplasias Faciales/radioterapia , Obstrucción del Conducto Lagrimal/prevención & control , Conducto Nasolagrimal/cirugía , Neuroblastoma/radioterapia , Implantación de Prótesis/instrumentación , Stents , Anciano , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos