Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País como asunto
Tipo del documento
Publication year range
1.
Med Microbiol Immunol ; 213(1): 18, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39101951

RESUMEN

Outbreaks of emerging diseases, like Mpox in 2022, pose unprecedented challenges to global healthcare systems. Although Mpox cases globally decreased since the end of 2022, numbers are still significant in the African Region, European Region, Region of the Americas, and Western Pacific Region. Rapid and efficient detection of infected individuals by precise screening assays is crucial for successful containment. In these assays, analytical and clinical performance must be assessed to ensure high quality. However, clinical studies evaluating Mpox virus (MPXV) detection kits using patient-derived samples are scarce. This study evaluated the analytical and clinical performance of a new diagnostic MPXV real-time PCR detection kit (Sansure Monkeypox Virus Nucleic Acid Diagnostic Kit) using patient-derived samples collected in Germany during the MPXV clade IIb outbreak in 2022. Our experimental approach determined the Limit of Detection (LoD) to less than 200 cp/mL using whole blood samples and samples derived from vesicles or pustules. Furthermore, we tested potentially inhibiting substances and pathogens with homologous nucleic acid sequences or similar clinical presentation and detected no cross-reactivity or interference. Following this, the assay was compared to a CE-marked test in a clinical performance study and achieved a diagnostic sensitivity of 100.00% and diagnostic specificity of 96.97%. In summary, the investigated real-time PCR assay demonstrates high analytical performance and concurs with the competitor device with high specificity and sensitivity.


Asunto(s)
Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Alemania/epidemiología , Mpox/diagnóstico , Mpox/virología , Juego de Reactivos para Diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Límite de Detección , Brotes de Enfermedades , Parapoxvirus/aislamiento & purificación , Parapoxvirus/genética
2.
Int J Legal Med ; 135(1): 207-212, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32789579

RESUMEN

The sudden infant death syndrome (SIDS) is one of the leading causes of postneonatal infant death. It has been shown that there exists a complex relationship between SIDS and inherited cardiac disease. Next-generation sequencing and surveillance of cardiac channelopathy and cardiomyopathy genes represent an important tool for investigating the cause of death in SIDS cases. In the present study, targeted sequencing of 80 genes associated with genetic heart diseases in a cohort of 31 SIDS cases was performed. To determine the spectrum and prevalence of genetic heart disease associated mutations as a potential monogenic basis for SIDS, a stringent variant classification was applied and the percentage of rare (minor allele frequency ≤ 0.2%) and ultra-rare variants (minor allele frequency ≤ 0.005%) in these genes was assessed. With a minor allele frequency of ≤ 0.005%, about 20% of the SIDS cases exhibited a variant of uncertain significance (VUS), but in only 6% of these cases, gene variants proved to be "potentially informative." The present study shows the importance of careful variant interpretation. Applying stringent criteria misinterpretations are avoided, as the results of genetic analyses may have an important impact of the family members involved.


Asunto(s)
Muerte Súbita del Lactante/genética , Miosinas Cardíacas/genética , Estudios de Cohortes , Femenino , Genética Forense , Frecuencia de los Genes , Predisposición Genética a la Enfermedad , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Lactante , Recién Nacido , Masculino , Mutación , Cadenas Pesadas de Miosina/genética , Canal de Sodio Activado por Voltaje NAV1.5/genética , Canales de Potasio de Rectificación Interna/genética , Análisis de Secuencia de ADN
3.
J Microbiol Methods ; 210: 106754, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37263528

RESUMEN

PCR-based enteric multiplex panels represent a rapid and reliable alternative to conventional "classical" phenotypic stool diagnostics. The aim of this study was to establish a laboratory-developed non-commercial multiplex Real-Time-PCR panel for the detection of the most important bacterial stool pathogens, Salmonella spp., Shigella spp., Yersinia enterocolitica/ pseudotuberculosis and Campylobacter jejuni/coli. on the "open" cobas omni Utility Channel (UC) of the cobas 6800 system (Roche). The aim was to replace the laborious phenotypical stool diagnostics with a high throughput Real-Time PCR method. The respective primers and probes were designed to cover conserved genomic regions of the pathogens and validated using Ultramer oligonucleotides, positive stool material and reference strains. To further validate the multiplex PCR-assay, the following parameters were evaluated: analytical-sensitivity and -specificity, cross-reactivity, linearity and inter- and intra-assay variance as well as limit of detection (LOD). In addition a retrospective analysis of culture positive and negative samples from daily routine was performed using 745 native stool samples. The Gastro assay was linear over a 5-log-unit and within the expected dynamic range with amplification efficiencies ranging from 94.6% to 120%. In addition, all targets showed excellent coefficients of repeatability (≤ 1.11%), intermediate precision (≤ 1.02%) and total variance (≤ 1.39%). In terms of analytical sensitivity the assay demonstrated detection limits ranging from 7.83 copies per reaction to 14.4 copies per reaction. The assay showed excellent agreement with culture methods (>95%) and a 100% sensitivity and specificity after resolution of discrepant results. The multiplex-PCR assay provides a comprehensive, rapid and sensitive alternative to conventional methods for the detection of the major bacterial stool pathogens in diagnostic laboratories.


Asunto(s)
Bacterias , Yersinia pseudotuberculosis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Estudios Retrospectivos , Bacterias/genética , Tracto Gastrointestinal , Heces/microbiología , Reacción en Cadena de la Polimerasa Multiplex/métodos , Sensibilidad y Especificidad , Yersinia pseudotuberculosis/genética
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda