Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
J Heart Lung Transplant ; 42(5): 645-650, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36641296

RESUMEN

BACKGROUND: Delayed sternal closure may be required after left ventricular assist device (LVAD) implantation due to coagulopathy or hemodynamic instability. There is conflicting data regarding infection risk. METHODS: We performed a single-center, retrospective analysis of patients who received their first LVAD between May 2012 and January 2021. Patients were divided into delayed sternal closure (DSC) and primary sternal closure (PSC) groups. We used chi-squared or Fisher Exact tests, as appropriate, to compare the incidence of postoperative LVAD-related infections (mediastinal/sternal wound) and LVAD-specific infections (driveline and pump pocket) after definitive chest closure between these two groups. RESULTS: A total of 327 patients met eligibility criteria, including 127 (39%) patients that underwent DSC and 200 (61%) patients that had a PSC. Demographic and clinical characteristics were similar except for an overrepresentation of men (87% vs. 75%, p = .016), Interagency Registry of Mechanically Assisted Circulatory Support class I-II patients (89% vs 66%, p < .001), patients with a previous sternotomy (43% vs 13%, p < .001), and patients with chronic kidney disease (55% vs 43%, p = .030) in the DSC group. The median DSC time was 24 (IQR: 24-48) hours. The incidence of LVAD-related mediastinal/sternal wound infection was similar between the DSC and PSC groups (4.7% vs 3.0%, p = .419). There was no difference between DSC and PSC groups in the incidence of driveline infection (6.3% vs 9%, p = .411) and pump pocket infection (1.6% vs 1.5%, p =.901), respectively. CONCLUSIONS: DSC does not seem to increase the incidence of LVAD-related or LVAD-specific infection rates in heart failure patients undergoing device implantation surgery.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Masculino , Humanos , Estudios Retrospectivos , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/epidemiología , Esternotomía/efectos adversos , Complicaciones Posoperatorias , Resultado del Tratamiento
2.
Tex Heart Inst J ; 48(1)2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33946106

RESUMEN

Continuous-flow left ventricular assist device implantation is the typical treatment for end-stage heart failure. Improvements in device engineering and technology, surgical experience and technique, and perioperative management have advanced the field, and short-term results approach those of heart transplantation. Further improvements may be achieved by minimizing adverse physiologic effects associated with cardiopulmonary bypass. Therefore, we have developed an off-pump implantation approach for continuous-flow left ventricular assist devices. We detail our surgical technique for off-pump implantation of the HeartWare device.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Implantación de Prótesis/métodos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda