Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Aging Clin Exp Res ; 35(2): 375-385, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36460902

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is currently the treatment of choice for the majority of patients at moderate or high surgical risk. However, some complications occur frequently with this procedure. In this study, we aimed to assess whether the cusp-overlap view (COP) technique may be associated with a reduced incidence of some of these complications compared with the classical three-cusp view (TCV) technique. METHODS: In this single-center, retrospective study we investigated; technical success, postprocedural permanent pacemaker implantation (PPMI), new-onset stroke, pericardial tamponade, arrhythmia development, acute renal failure, major bleeding, major vascular complications, procedure-related coronary obstruction, new-onset left bundle branch block (LBBB), paravalvular leak, peri-procedural myocardial infarction (MI), day of hospitalization, death, and major adverse cardiac and cerebrovascular events (MACCE) were determined as the clinical endpoints. RESULTS: A total of 281 consecutive patients who met the study criteria and underwent elective or emergency transfemoral TAVI using the self-expandable CoreValve Evolut valve were included. 176 consecutive patients implanted with the classical TCV technique and 105 consecutive patients implanted with the COP technique were compared. Compared with the TCV group, patients in the COP group had lower PPMI (3.8% vs. 10.8%, p = 0.039), in-hospital mortality (1.9% vs. 8.5%, p = 0.018), and 1-year death (4.8% versus 18.8%, p = 0.001), and MACCE rates (12.4% vs 31.3%, p < 0.001). CONCLUSION: The COP technique may help to reduce the conduction disturbances, PPMI requirement and complication rates that may develop following TAVI. In addition, it is an interesting result that it reduces mortality and MACCE rates in long-term follow-ups.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estudios Transversales , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Prótesis Valvulares Cardíacas/efectos adversos , Marcapaso Artificial/efectos adversos
2.
Vascular ; 31(5): 1003-1010, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35509195

RESUMEN

OBJECTIVE: This study aimed to investigate the efficacy of foam sclerotherapy in the treatment of tortuous Great Saphenous Vein (GSV) insufficiency. METHODS: In this prospective non-randomized study 62 patients with tortuous GSV insufficiency were included. All patients were delivered sclerosant agent in the form of foam into the GSV through a cannula above the knee level. Characteristics of patients, diameter of veins, reflux grades, Venous Clinical Severity Score (VCSS) and Clinical, Etiological, Anatomical, Pathological (CEAP) scores, concentration of sclerosant agent, complications and follow-up results were recorded. RESULTS: Foam sclerotheraphy was performed with 100% technical success in all patients at operative room. There were no allergic reactions or neurological complications during and after the operations. Ecchymosis was the most common complication with 37.1% frequency. . VCSS scores significantly decreased from 6.43% to 2.53%, during follow-up from initial admission to sixth months, respectively (P<0.05).In the first month parameters, successful occlusion rate was 88.7%, whereas its rate was 82.3% in sixth month. Recanalization rate significantly increased from 11.3% to 17.7% during follow-up from first to sixth months, respectively (P<0.05). CONCLUSIONS: Due to its low complication rate, low cost, acceptable total occlusion rate and reproducibility; Foam sclerotherapy can be considered a reliable treatment for patients with tortuous GSV insufficiency.


Asunto(s)
Várices , Insuficiencia Venosa , Humanos , Soluciones Esclerosantes/efectos adversos , Várices/diagnóstico por imagen , Várices/terapia , Várices/complicaciones , Insuficiencia Venosa/diagnóstico por imagen , Insuficiencia Venosa/terapia , Insuficiencia Venosa/complicaciones , Vena Safena/diagnóstico por imagen , Vena Safena/cirugía , Estudios Prospectivos , Reproducibilidad de los Resultados , Resultado del Tratamiento , Escleroterapia/efectos adversos
3.
Kardiologiia ; 63(11): 73-79, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38088115

RESUMEN

Objective    The prognostic nutritional index (PNI) is a practical, applicable, prognostic scoring system. However, its clinical significance in unprotected left main coronary artery (ULMCA) patients undergoing percutaneous coronary intervention (PCI) has not yet been clarified. This study aimed to examine the relationship between malnutrition as assessed by PNI and major adverse cardiac events (MACE) in ULMCA patients undergoing PCI.Material and methods    185 patients who were hospitalized in our clinic underwent coronary angiography, had a critical LMCA lesion, and underwent angiography-guided PCI were included. The study population was divided into tertiles based on the PNI values. A high PNI (n=142) was defined as a value in the third tertile (≥ 34.0), and a low PNI (n=43) was defined as a value in the lower 2 tertiles (< 34.0). The primary endpoint was MACE.Results    MACE and mortality rates in the low PNI group were significantly higher compared to the high PNI group (51 % vs. 30 %, p=0.009; 44 % vs. 20 %, p=0.002, respectively). High PNI (HR:1.902; 95 % CI:1.112-3.254; p=0.019), previous stroke (HR:3.025; 95 % CI:1.038-8.810; p=0.042) and SYNTAX score (HR:1.028; 95 % CI:1.004-1.057, p=0.023) were independent predictors of MACE in the multivariable cox regression analyzes.Conclusions    In patients undergoing ULMCA PCI, nutritional status can be considered an indicator of MACE rates by evaluating the PNI score. This index can be used for risk classification.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Evaluación Nutricional , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Pronóstico , Resultado del Tratamiento , Angiografía Coronaria , Factores de Riesgo
4.
Acta Clin Croat ; 61(3): 421-426, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37492352

RESUMEN

Introduction: The gold standard of circulation strategy and arterial cannulation during acute aortic dissection is still indisputable. Unilateral/bilateral antegrade cerebral perfusion (UACP/BACP) and deep hypothermic circulatory arrest (HCA) remains a safe and useful procedure for circulation during management of acute aortic dissection. The aim of our study was to investigate the effectiveness of both unilateral antegrade cerebral perfusion and deep hypothermic circulatory arrest on postoperative outcomes during management of acute aortic dissection repair at our center. Methods: Our prospective study consisted of 26 patients who underwent acute aortic dissection repair with various circulation strategy. Group A consisted of 14 (53.8%) patients who were operated on under unilateral antegrade cerebral perfusion, while group B consisted of 12 (46.2%) patients who were operated on under deep hypothermic circulatory arrest without cerebral perfusion. Postoperative outcomes included mortality, drainage, blood transfusion (free frozen plasma, erythrocyte suspension), ventilation time and revision due to bleeding. Results: The average age of our study population was 55.2 ± 16.2 (range 33-83) years. Mortality was observed in 3 (11.5%) of our patients. There was no significant difference between the groups in terms of mortality and revision due to bleeding (p ˃ 0.05). Blood transfusion (erythrocyte suspension and free frozen plasma), drainage and ventilation time were significantly lower in Group A compared with Group B (p ˃ 0.05). Conclusion: Both unilateral antegrade cerebral circulation and deep hypothermic circulatory arrest can be safely used during acute aortic dissection, although unilateral antegrade cerebral circulation has proved to be superior over deep hypothermic circulatory arrest with good postoperative outcomes.


Asunto(s)
Disección Aórtica , Paro Circulatorio Inducido por Hipotermia Profunda , Humanos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Paro Circulatorio Inducido por Hipotermia Profunda/métodos , Estudios Prospectivos , Disección Aórtica/cirugía , Perfusión/métodos , Circulación Cerebrovascular , Estudios Retrospectivos , Resultado del Tratamiento
5.
J Card Surg ; 35(10): 2469-2476, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32789962

RESUMEN

BACKGROUND: Pulmonary artery perfusion during cardiopulmonary bypass (CPB) is a known but rarely used technique in adult cardiac surgery. In this study, we aimed to investigate biochemical and histopathological effects of pulmonary artery perfusion during CPB on lung functions. METHODS: Between May 2014 and August 2014, all patients (n = 24) who gave informed consent for participating this study with inclusion criteria were included. Patients undergoing isolated coronary artery bypass grafting were sequentially randomized to conventional CPB (control group, n = 12) and conventional CPB with selective pulmonary artery perfusion (study group, n = 12). Lung functions were monitored using PF ratio, alveolar-arterial oxygen gradient, and lactate levels. A small sample tissue from the left lung was excised for histopathologic examination. Immunocytochemistry analysis was performed using anti-rabbit polyclonal vascular endothelial growth factor (VEGF), rabbit polyclonal inducible nitric oxide synthase (i-NOS), and BCL-2 antibodies. RESULTS: Postoperative course of the patients were uneventful without any clinical outcome differences in terms of cardiopulmonary complications, ventilation time and hospital stay. Pulmonary perfusion group had significantly better oxygenation values after extubation and at postoperative 24-hour. Electron microscopy examinations revealed better preservation of the alveolar wall integrity with pulmonary perfusion. The intensity of VEGF, i-NOS, and BCL-2 antibody expressions in bronchial epithelial cells were more prominent in the pulmonary perfusion group. CONCLUSIONS: Pulmonary artery perfusion during aortic cross-clamping provides better oxygenation and preservation of the wall alveolar integrity after coronary artery bypass grafting surgery. This technique can be used as a protective strategy to minimize CPB-induced lung injury in adult cardiac surgery.


Asunto(s)
Lesión Pulmonar Aguda/etiología , Lesión Pulmonar Aguda/prevención & control , Puente Cardiopulmonar/efectos adversos , Perfusión/métodos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Arteria Pulmonar , Lesión Pulmonar Aguda/diagnóstico , Lesión Pulmonar Aguda/patología , Adulto , Anciano , Biomarcadores/análisis , Biomarcadores/sangre , Recuento de Células Sanguíneas , Proteína C-Reactiva , Puente de Arteria Coronaria/métodos , Femenino , Hemoglobinas , Humanos , Inflamación , Pulmón/patología , Pulmón/ultraestructura , Masculino , Persona de Mediana Edad , Óxido Nítrico Sintasa de Tipo II/análisis , Recuperación de la Función , Esternotomía , Factor A de Crecimiento Endotelial Vascular/análisis
6.
Thorac Cardiovasc Surg ; 64(3): 217-24, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25875954

RESUMEN

BACKGROUND: Pericardial effusion (PE), atrial fibrillation (AF), and acute kidney injury (AKI) are commonly found after coronary artery surgery. These adverse events may also be interwoven in the postoperative period. In this prospective study, we investigated whether posterior pericardiotomy (PP) with intrapericardial tube positioned along the right atrium (pericardial space intervention) is effective in the prevention of these adverse events. METHODS: The patients were randomly distributed to the study and control groups. The study group consisted of patients with pericardial space intervention, whereas the control group consisted of patients without pericardial space interventions. In all patients, a straight tube was placed in the anterior mediastinum and an angled tube was placed into the left hemithorax. RESULTS: A total of 210 patients were studied: 107 in the control group and 103 in the study group. Statistically significant results were obtained in the amount of PE, cardiac tamponade, AF (p = 0.019), and AKI during the postoperative period, in favor of the study group. Length of hospital stay was significantly shorter in the study group (6.11 ± 2.31, p = 0.009). CONCLUSION: The PP with intrapericardial tube approach is safe, easy, and effective in the prevention of PE, cardiac tamponade, and AF. The use of this approach may reduce the risk of developing AKI during the postoperative period. Besides, this technique also reduces the length of hospital stay.


Asunto(s)
Lesión Renal Aguda/prevención & control , Fibrilación Atrial/prevención & control , Puente de Arteria Coronaria/efectos adversos , Derrame Pericárdico/prevención & control , Pericardiectomía/métodos , Pericardio/cirugía , Complicaciones Posoperatorias/prevención & control , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Anciano , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Tiempo de Internación/tendencias , Masculino , Persona de Mediana Edad , Derrame Pericárdico/epidemiología , Derrame Pericárdico/etiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento , Turquía/epidemiología
7.
Turk Gogus Kalp Damar Cerrahisi Derg ; 31(2): 278-281, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37484637

RESUMEN

Hydatid cysts can be located in any organ or tissue system. Cardiac hydatid cyst is a rare, but fatal pathology. A 21-year-old male Syrian refugee patient with no previous known medical conditions was admitted to the hospital for chest pain and shortness of breath. He had increasing leg pain for 12 hours. Hydatid cyst rupture was detected on echocardiography. The peripheral artery thrombus and hydatid cyst membrane were removed with the embolectomy. The patient had renal and cranial infarctions. He underwent fasciotomy due to compartment syndrome. In conclusion, delayed diagnosis and treatment of cardiac hydatid cysts may result in a poor prognosis associated with the risk of rupture and is responsible for the spread of infection throughout the body as a result of the rupture. Even if there is an early diagnosis, surgical treatment supported by medical treatment is recommended very early.

8.
Braz J Cardiovasc Surg ; 37(3): 328-334, 2022 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-34236798

RESUMEN

OBJECTIVE: Sutureless aortic valve replacement (Su-AVR) offers an alternative to supra-annular stented biological aortic prostheses. This single-center study aimed to compare early outcomes after aortic valve replacement with sutureless and conventional stented bioprostheses. METHODS: In this retrospective study, we analyzed 52 patients who underwent aortic valve replacement with sutureless and stented bioprostheses between January 2013 and October 2017. Sorin Perceval S sutureless valves were implanted in group 1 and Sorin Mitroflow stented bioprosthetic valves were used in group 2. Postoperative outcomes, including demographics, cardiopulmonary bypass (CPB) times, cross-clamp times, morbidity and mortality, as well as echocardiography in the first month, were compared. RESULTS: Mortality occurred in 1 (3.6%) patient in group 1, and in 2 (8.3%) patients in group 2 (P=0.186). Group 1 had significantly shorter CPB (61.6±26.1 min vs. 106.3±32.7 min, P=0.001) and crossclamp (30.9±13.6 min vs. 73.3±17.3 min, P=0.001) times. The length of stay in the intensive care unit (1.9±1.3 days vs. 2.4±4.9 days, P=0.598) and hospital stay (7.6±2.7 days vs. 7.3±2.6 days, P=0.66) were similar. Postoperatively, there was no statistically significant difference between the two groups in echocardiography results, and morbidities. The mean aortic valve gradient was 13.5±5.8 mmHg in group 1 and 14.5±8.0 mmHg in group 2 (P=0.634). Paravalvular regurgitation was diagnosed in 3 (10.7%) patients in group 1 and in 1 (4.2%) patient in group 2 (P=0.220). CONCLUSIONS: Su-AVR resulted in shorter cross-clamp and CPB times. However, early mortality, postoperative morbidity, and echocardiography results were similar between groups.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
9.
Braz J Cardiovasc Surg ; 37(5): 680-687, 2022 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-35244373

RESUMEN

INTRODUCTION: Custodiol (histidine-tryptophan-ketoglutarate) and repetitive blood cardioplegia are the solutions for myocardial protection and cardiac arrest. In this study, we aimed to compare immunohistochemical analysis, clinical outcomes, and cardiac enzyme values of Custodiol and blood cardioplegia groups. METHODS: This was a randomized prospective study consisting of 2 groups and 20 patients, 10 patients for each group, who underwent mitral and mitral/tricuspid valve surgery. Group 1 was formed for Custodiol cardioplegia and group 2 for blood cardioplegia. Perioperative and postoperative cardiac events were recorded, cardiac enzymes were analyzed with intervals, and myocardial samples were taken for immunohistochemical analysis. Recorded data were statistically evaluated. RESULTS: There was no significant difference for the Custodiol and blood cardioplegia groups in perioperative and postoperative cardiac performance and adverse events. Cardiac enzyme analysis showed no significant difference between groups. However, two parameters (eNOS, Bcl-2) were in favor of the Custodiol group in immunohistochemical studies. Custodiol performed better in cellular oxidative stress resistance and cellular viability. CONCLUSION: Clinical outcomes and cardiac enzyme analysis results were similar regarding myocardial protection. However, Custodiol performed better in the immunohistochemical analysis.


Asunto(s)
Soluciones Cardiopléjicas , Manitol , Humanos , Soluciones Cardiopléjicas/farmacología , Soluciones Cardiopléjicas/uso terapéutico , Estudios Prospectivos , Cloruro de Potasio , Glucosa , Paro Cardíaco Inducido/métodos
11.
Turk Gogus Kalp Damar Cerrahisi Derg ; 27(2): 143-151, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32082845

RESUMEN

BACKGROUND: The aim of this study is to analyze the outcomes and incidence of postoperative patient-prothesis mismatch after surgical aortic valve replacement using supra-annular bioprosthesis and transcatheter aortic valve implantation. METHODS: Between January 2012 and June 2015, a total of 73 patients (37 males, 36 females; mean age 71.8±5.7 years; range, 65 to 82 years) who underwent either surgical aortic valve replacement using supraannular bioprosthesis (n=36) or transcatheter aortic valve implantation (n=37) were included. Postoperative patient-prothesis mismatch was defined as absent, mild-to-moderate, and severe, if the indexed effective orifice area was >0.85 cm2/m2, >0.65 to <0.85 cm2/m2, and <0.65 cm2/m2, respectively. Both groups were compared in terms of patient-prothesis mismatch, postoperative outcomes, and mortality. RESULTS: The overall incidence of mild-to-moderate patient-prosthesis mismatch was 17.8% (13/73). No severe patient-prosthesis mismatch was observed. Mild-to-moderate patient-prosthesis mismatch was found in three patients (8.1%) in the transcatheter group and in 10 patients (27.8%) in the surgery group (p=0.035). Body surface area was the significant predictor of patient-prosthesis mismatch (p=0.007). Diameters of bioprosthetic valves in the surgery and transcatheter groups were 21.4±2 and 23.9±2.6 mm, respectively (p=0.002). Early mortality and pacemaker implantation rates were higher in the transcatheter group (p>0.05). Postoperative outcomes were similar between the groups. Mid-term mortality at a mean follow-up of 47.7±7.3 months was similar between the groups (p=0.158). CONCLUSION: In high-risk patients with severe aortic stenosis, patientprosthesis mismatch is mild-to-moderate after surgical aortic valve replacement and transcatheter aortic valve implantation; however, this has no effect on early mortality. Based on our study results, we suggest that the use of surgical approach for aortic valve replacement may prevent potential complications of transcatheter aortic valve implantation.

12.
Braz J Cardiovasc Surg ; 33(5): 443-447, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30517251

RESUMEN

INTRODUCTION: Various surgical procedures for minimally invasive cardiac surgery have been described in recent decades as alternatives to median sternotomy. Cardiopulmonary bypass via femoral arterial and venous cannulation is the foundation of these procedures. In this study, we evaluated the mid-term outcomes of femoral cannulation performed with U-suture technique in patients undergoing robotic heart surgery. METHODS: A total of 216 patients underwent robotic-assisted cardiac surgery between January 2013 and April 2017. Cardiopulmonary bypass was performed via femoral artery, jugular, and femoral vein cannulation, and a Chitwood clamp was used for aortic occlusion. A total of 192 patients attended the outpatient follow-up, and femoral arterial and venous flow pattern was examined using Doppler ultrasound (DUS) in 145 patients. RESULTS: Hospital mortality occured in 4 of the 216 (1.85%) cases, but there was no late mortality in this patient group. Postoperatively, seroma (n=9, 4.69%) and cannulation site infection (n=3, 1.56%) were managed with outpatient treatment. DUS in 145 patients revealed triphasic flow pattern in the common femoral arteries in all patients except for 2 (1.38%). These patients were determined to have asymptomatic arterial stenosis. Chronic recanalized thrombus in the common femoral vein was also detected in 2 (1.38%) patients. CONCLUSION: Femoral artery cannulation with the U-suture technique can be successfully performed in robotic-assisted cardiac surgery, with good mid-term results.


Asunto(s)
Arteriopatías Oclusivas/cirugía , Puente Cardiopulmonar/métodos , Procedimientos Quirúrgicos Robotizados , Adulto , Velocidad del Flujo Sanguíneo , Puente Cardiopulmonar/efectos adversos , Femenino , Arteria Femoral , Vena Femoral , Estudios de Seguimiento , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos , Resultado del Tratamiento
13.
Rev. bras. cir. cardiovasc ; 37(3): 328-334, May-June 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1376532

RESUMEN

Abstract Objective: Sutureless aortic valve replacement (Su-AVR) offers an alternative to supra-annular stented biological aortic prostheses. This single-center study aimed to compare early outcomes after aortic valve replacement with sutureless and conventional stented bioprostheses. Methods: In this retrospective study, we analyzed 52 patients who underwent aortic valve replacement with sutureless and stented bioprostheses between January 2013 and October 2017. Sorin Perceval S sutureless valves were implanted in group 1 and Sorin Mitroflow stented bioprosthetic valves were used in group 2. Postoperative outcomes, including demographics, cardiopulmonary bypass (CPB) times, cross-clamp times, morbidity and mortality, as well as echocardiography in the first month, were compared. Results: Mortality occurred in 1 (3.6%) patient in group 1, and in 2 (8.3%) patients in group 2 (P=0.186). Group 1 had significantly shorter CPB (61.6±26.1 min vs. 106.3±32.7 min, P=0.001) and cross-clamp (30.9±13.6 min vs. 73.3±17.3 min, P=0.001) times. The length of stay in the intensive care unit (1.9±1.3 days vs. 2.4±4.9 days, P=0.598) and hospital stay (7.6±2.7 days vs. 7.3±2.6 days, P=0.66) were similar. Postoperatively, there was no statistically significant difference between the two groups in echocardiography results, and morbidities. The mean aortic valve gradient was 13.5±5.8 mmHg in group 1 and 14.5±8.0 mmHg in group 2 (P=0.634). Paravalvular regurgitation was diagnosed in 3 (10.7%) patients in group 1 and in 1 (4.2%) patient in group 2 (P=0.220). Conclusions: Su-AVR resulted in shorter cross-clamp and CPB times. However, early mortality, postoperative morbidity, and echocardiography results were similar between groups.

14.
Tex Heart Inst J ; 42(2): 166-8, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25873832

RESUMEN

Atrioventricular septal defects constitute 4% of all congenital cardiac malformations. Patients with complete atrioventricular septal defect rarely survive for decades without surgical treatment. Pulmonary stenosis can provide a delicate balance between the pulmonary and systemic circulations and thereby increase longevity. We present the case of a 49-year-old woman whose complete atrioventricular septal defect and associated pulmonary stenosis were diagnosed only after she had given birth to 10 live children through uneventful spontaneous delivery. We discuss her successful surgical treatment in terms of the available medical literature.


Asunto(s)
Insuficiencia de la Válvula Mitral/diagnóstico , Complicaciones Cardiovasculares del Embarazo/diagnóstico , Estenosis de la Válvula Pulmonar/diagnóstico , Procedimientos Quirúrgicos Cardíacos , Comorbilidad , Femenino , Defectos de los Tabiques Cardíacos , Humanos , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Paridad , Embarazo , Complicaciones Cardiovasculares del Embarazo/epidemiología , Resultado del Embarazo , Estenosis de la Válvula Pulmonar/epidemiología , Factores de Tiempo , Ultrasonografía
15.
Kardiochir Torakochirurgia Pol ; 11(2): 113-8, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26336406

RESUMEN

INTRODUCTION: Pericardial effusion and atrial fibrillation occur commonly after coronary artery surgery. AIM OF THE STUDY: A prospective randomized clinical trial was conducted to evaluate the effects of posterior pericardiotomy on the occurrence of pericardial effusion, tamponade, and atrial fibrillation. MATERIAL AND METHODS: The study group consisted of 96 patients (77 male and 19 female) at a mean age of 58.1 ± 9.8 years. The patients were randomly assigned to one of three study groups: patients undergoing posterior pericardiotomy (group I, n = 30), controls (group II, n = 33), and patients with additional posterior pericardial drainage tubes (28 mm) who did not undergo posterior pericardiotomy (group III, n = 33). RESULTS: Postoperative hospitalization (p = 0.03; 11.56 ± 10.64) and reoperation due to tamponade (p = 0.019; 12.1%) were significantly higher in group II. Extensive pericardial effusions were detected in one patient on the first postoperative day (group II, n = 1), in one patient on the fifth postoperative day (group III, n = 1), and in one patient on the 30(th) day after the operation (group III, n = 1). Pericardial effusion exhibited regression in group I on postoperative day 30 (p = 0.028). A higher rate of postoperative atrial fibrillation was noted in group I, but no significant differences were found between the groups with regard to postoperative atrial fibrillation. CONCLUSIONS: Patients who did not undergo posterior pericardiotomy or did not receive posterior chest tubes exhibited residual pericardial effusion, required longer hospitalization, and had to be reoperated due to tamponade. Both posterior pericardiotomy and the use of posterior tubes are effective in the early postoperative period.

16.
Rev. bras. cir. cardiovasc ; 33(5): 443-447, Sept.-Oct. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-977454

RESUMEN

Abstract Introduction: Various surgical procedures for minimally invasive cardiac surgery have been described in recent decades as alternatives to median sternotomy. Cardiopulmonary bypass via femoral arterial and venous cannulation is the foundation of these procedures. In this study, we evaluated the mid-term outcomes of femoral cannulation performed with U-suture technique in patients undergoing robotic heart surgery. Methods: A total of 216 patients underwent robotic-assisted cardiac surgery between January 2013 and April 2017. Cardiopulmonary bypass was performed via femoral artery, jugular, and femoral vein cannulation, and a Chitwood clamp was used for aortic occlusion. A total of 192 patients attended the outpatient follow-up, and femoral arterial and venous flow pattern was examined using Doppler ultrasound (DUS) in 145 patients. Results: Hospital mortality occured in 4 of the 216 (1.85%) cases, but there was no late mortality in this patient group. Postoperatively, seroma (n=9, 4.69%) and cannulation site infection (n=3, 1.56%) were managed with outpatient treatment. DUS in 145 patients revealed triphasic flow pattern in the common femoral arteries in all patients except for 2 (1.38%). These patients were determined to have asymptomatic arterial stenosis. Chronic recanalized thrombus in the common femoral vein was also detected in 2 (1.38%) patients. Conclusion: Femoral artery cannulation with the U-suture technique can be successfully performed in robotic-assisted cardiac surgery, with good mid-term results.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Arteriopatías Oclusivas/cirugía , Puente Cardiopulmonar/métodos , Procedimientos Quirúrgicos Robotizados , Velocidad del Flujo Sanguíneo , Puente Cardiopulmonar/efectos adversos , Estudios de Seguimiento , Resultado del Tratamiento , Procedimientos Quirúrgicos Mínimamente Invasivos , Arteria Femoral , Vena Femoral
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda