RESUMEN
Most coagulation tests are photo-optical turbidimetric assays that require the removal of cellular components from whole blood for optical clearing. If the resulting blood plasma samples are hemolyzed, they may become unsuitable for turbidimetric analysis. To resolve this issue, whole-blood analogs to plasma turbidimetric assays need to be developed. Using samples collected from non-smokers (normal group), smokers (thrombotic group), and hemophilia A (bleeding group) patients, we demonstrate that the reaction time assessed from whole blood viscosity data of the drop-of-blood acoustic tweezing spectroscopy (ATS) technique strongly correlates (Rp ≥ 0.95) with PT/aPTT values obtained from plasma turbidimetric data. Linear correlation (Rp ≥ 0.88) was also obtained between the viscous and elastic outputs of the ATS technique and the fibrinogen concentration. The integration of ATS data enabled the assessment of the functional level of fibrin cross-linkers such as factor XIII. Overall, ATS allows comprehensive sample-sparing analysis of whole blood coagulation for reliable and safe diagnosis of bleeding/thrombosis risks.
Asunto(s)
Acústica , Fibrinógeno , Humanos , Tiempo de Protrombina , Tiempo de Tromboplastina Parcial , Pruebas de Coagulación Sanguínea , Fibrinógeno/análisis , Análisis EspectralRESUMEN
Many patients develop coagulation abnormalities due to chronic and hereditary disorders, infectious disease, blood loss, extracorporeal circulation, and oral anticoagulant misuse. These abnormalities lead to bleeding or thrombotic complications, the risk of which is assessed by coagulation analysis. Current coagulation tests pose safety concerns for neonates and small children due to large sample volume requirement and may be unreliable for patients with coagulopathy. This study introduces a containerless drop-of-blood method for coagulation analysis, termed "integrated quasi-static acoustic tweezing thromboelastometry" (i-QATT™), that addresses these needs. In i-QATT™, a single drop of blood is forced to levitate and deform by the acoustic radiation force. Coagulation-induced changes in drop turbidity and firmness are measured simultaneously at different instants. The parameters describing early, intermediate, and late stages of the coagulation process are evaluated from the resulting graphical outputs. i-QATT™ rapidly (<10 min) detected hyper- and hypo-coagulable states and identified single deficiency in coagulation factors VII, VIII, IX, X, and XIII. The linear relationship (r2 > 0.9) was established between fibrinogen concentration and two i-QATT™ parameters: maximum clot firmness and maximum fibrin level. Factor XIII activity was uniquely measured by the fibrin network formation time (r2 = 0.9). Reaction time, fibrin formation rate, and time to firm clot formation were linearly correlated with heparin concentration (r2 > 0.7). tPA-induced hyperfibrinolysis was detected in the clot firmness output at 10 min. i-QATT™ provides comprehensive coagulation analysis in point-of-care or laboratory settings, well suited to the needs of neonatal and pediatric patients and adult patients with anemia or blood collection issues.
Asunto(s)
Coagulación Sanguínea , Nefelometría y Turbidimetría/métodos , Tromboelastografía/métodos , Anticoagulantes/uso terapéutico , Monitoreo de Drogas , Estudios de Factibilidad , HumanosRESUMEN
Knowledge of rheological properties, such as viscosity and elasticity, is necessary for efficient material processing and transportation as well as biological analysis. Existing rheometers operate with large sample volume and induce sample contact with container or device walls, which are inadequate for rheological analysis of sensitive fluids limited in availability. In this work, we introduce acoustic tweezing spectroscopy (ATS), a novel noncontact rheological technique that operates with a single 4-6 µl drop of fluid sample. In ATS, a sample drop is acoustically levitated and then exposed to a modulated acoustic signal to induce its forced oscillation. The time-dependent sample viscosity and elasticity are measured from the resulting drop response. The ATS measurements of polymeric solutions (dextran, xanthan gum, gelatin) agree well with previously reported data. The ATS predicts that the shear viscosity of blood plasma increases from 1.5 cP at 1.5 min of coagulation onset to 3.35 cP at 9 min, while its shear elastic modulus grows from a negligible value to 10.7 Pa between 3.5 min and 6.5 min. Coagulation increases whole blood viscosity from 5.4 cP to 20.7 cP and elasticity from 0.1 Pa to 19.2 Pa at 15 min. In summary, ATS provides the opportunity for sensitive small-volume rheological analysis in biomedical research and medical, pharmaceutical, and chemical industries.