RESUMEN
Salivary turbidity is a promising indicator for evaluating oral hygiene. This study proposed a wearable mouthguard-type sensor for continuous and unconstrained measurement of salivary turbidity. The sensor evaluated turbidity by measuring the light transmittance of saliva with an LED and a phototransistor sealed inside a double-layered mouthguard. The sensor was also embedded with a Bluetooth wireless module, enabling the wireless measurement of turbidity. The mouthguard materials (polyethylene terephthalate-glycol and ethylene-vinyl acetate) and the wavelength of the LED (405 nm) were experimentally determined to achieve high sensitivity in salivary turbidity measurement. The turbidity quantification characteristic of the proposed sensor was evaluated using a turbidity standard solution, and the sensor was capable of turbidity quantification over a wide dynamic range of 1-4000 FTU (formazine turbidity unit), including reported salivary turbidity (400-800 FTU). In vitro turbidity measurement using a saliva sample showed 553 FTU, which is equivalent to the same sample measured with a spectrophotometer (576 FTU). Moreover, in vivo experiments also showed results equivalent to that measured with a spectrophotometer, and wireless measurement of salivary turbidity was realized using the mouthguard-type sensor. Based on these results, the proposed mouthguard-type sensor has promising potential for the unconstrained continuous evaluation of oral hygiene.
Asunto(s)
Protectores Bucales , Dispositivos Electrónicos Vestibles , Higiene Bucal , SalivaRESUMEN
In orthodontics, understanding the pressure of oral soft tissues on teeth is important to elucidate the cause and establish treatment methods. We developed a small wireless mouthguard (MG)-type device that continuously and unrestrainedly measures pressure, which had previously been unachieved, and evaluated its feasibility in human subjects. First, the optimal device components were considered. Next, the devices were compared with wired-type systems. Subsequently, the devices were fabricated for human testing to measure tongue pressure during swallowing. The highest sensitivity (51-510 g/cm2) with minimum error (CV < 5%) was obtained using an MG device with polyethylene terephthalate glycol and ethylene vinyl acetate for the lower and upper layers, respectively, and with a 4 mm PMMA plate. A high correlation coefficient (0.969) was observed between the wired and wireless devices. In the measurements of tongue pressure on teeth during swallowing, 132.14 ± 21.37 g/cm2 for normal and 201.17 ± 38.12 g/cm2 for simulated tongue thrust were found to be significantly different using a t-test (n = 50, p = 6.2 × 10-19), which is consistent with the results of a previous study. This device can contribute to assessing tongue thrusting habits. In the future, this device is expected to measure changes in the pressure exerted on teeth during daily life.