Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Eur Spine J ; 30(8): 2351-2359, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34023965

RESUMEN

PURPOSE: This study's objective was to assess biomechanical parameters across fused and contralateral sacroiliac joints (SIJs) and implants during all spinal motions for both sexes. Various SIJ implant devices on the market are used in minimally invasive surgeries. These implants are placed across the joint using different surgical approaches. The biomechanical effects of fusion surgical techniques in males and females have not been studied. METHODS: The validated finite element models of a male, and a female spine-pelvis-femur were unilaterally instrumented across the SIJ using three screws for two SIJ implants, half threaded and fully threaded screws placed laterally and posteriorly to the joint, respectively. RESULTS: Motion and peak stress data at the SIJs showed that the female model exhibited lower stresses and higher reduction in motion at the contralateral SIJ in all motions than the male model predictions with 84% and 71% reductions in motion and stresses across the SIJ. CONCLUSION: Implants exhibited higher stresses in the female model compared to the male model. However, chances of SIJ implant failure in the female patients are still minimal, based on the calculated factor of safety which is still very high. Both lateral and posterior surgical approaches were effective in both sexes; however, the lateral approach may provide a better biomechanical response, especially for females. Moreover, implant design characteristics did not make a difference in the implants' biomechanical performance. SIJ stabilization was primarily provided by the implants which were the farthest from the sacrum rotation center.


Asunto(s)
Dolor de la Región Lumbar , Articulación Sacroiliaca , Fenómenos Biomecánicos , Femenino , Análisis de Elementos Finitos , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos , Prótesis e Implantes , Articulación Sacroiliaca/cirugía
2.
Neurosurg Focus ; 50(5): E12, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33932920

RESUMEN

OBJECTIVE: Achieving rigid spinal fixation can be challenging in patients with cancer-related instability, as factors such as osteopenia, radiation, and immunosuppression adversely affect bone quality. Augmenting pedicle screws with cement is a strategy to overcome construct failure. This study aimed to assess the safety and efficacy of cement augmentation with fenestrated pedicle screws in patients undergoing posterior, open thoracolumbar surgery for spinal metastases. METHODS: A retrospective review was performed for patients who underwent surgery for cancer-related spine instability from 2016 to 2019 at the Massachusetts General Hospital. Patient demographics, surgical details, radiographic characteristics, patterns of cement extravasation, complications, and prospectively collected Patient-Reported Outcomes Measurement Information System Pain Interference and Pain Intensity scores were analyzed using descriptive statistics. Logistic regression was performed to determine factors associated with cement extravasation. RESULTS: Sixty-nine patients underwent open posterior surgery with a total of 502 cement-augmented screws (mean 7.8 screws per construct). The median follow-up period for those who survived past 90 days was 25.3 months (IQR 10.8-34.6 months). Thirteen patients (18.8%) either died within 90 days or were lost to follow-up. Postoperative CT was performed to assess the instrumentation and patterns of cement extravasation. There was no screw loosening, pullout, or failure. The rate of cement extravasation was 28.9% (145/502), most commonly through the segmental veins (77/145, 53.1%). Screws breaching the lateral border of the pedicle but with fenestrations within the vertebral body were associated with a higher risk of leakage through the segmental veins compared with screws without any breach (OR 8.77, 95% CI 2.84-29.79; p < 0.001). Cement extravasation did not cause symptoms except in 1 patient who developed a symptomatic thoracic radiculopathy requiring decompression. There was 1 case of asymptomatic pulmonary cement embolism. Patients experienced significant pain improvement at the 3-month follow-up, with decreases in Pain Interference (mean change 15.8, 95% CI 14.5-17.1; p < 0.001) and Pain Intensity (mean change 28.5, 95% CI 26.7-30.4; p < 0.001). CONCLUSIONS: Cement augmentation through fenestrated pedicle screws is a safe and effective option for spine stabilization in the cancer population. The risk of clinically significant adverse events from cement extravasation is very low.


Asunto(s)
Neoplasias , Tornillos Pediculares , Fusión Vertebral , Cementos para Huesos/uso terapéutico , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Estudios Retrospectivos
3.
Neurosurg Focus ; 50(5): E5, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33932935

RESUMEN

OBJECTIVE: Frailty is recognized as an important consideration in patients with cancer who are undergoing therapies, including spine surgery. The definition of frailty in the context of spinal metastases is unclear, and few have studied such markers and their association with postoperative outcomes and survival. Using national databases, the metastatic spinal tumor frailty index (MSTFI) was developed as a tool to predict outcomes in this specific patient population and has not been tested with external data. The purpose of this study was to test the performance of the MSTFI with institutional data and determine whether machine learning methods could better identify measures of frailty as predictors of outcomes. METHODS: Electronic health record data from 479 adult patients admitted to the Massachusetts General Hospital for metastatic spinal tumor surgery from 2010 to 2019 formed a validation cohort for the MSTFI to predict major complications, in-hospital mortality, and length of stay (LOS). The 9 parameters of the MSTFI were modeled in 3 machine learning algorithms (lasso regularization logistic regression, random forest, and gradient-boosted decision tree) to assess clinical outcome prediction and determine variable importance. Prediction performance of the models was measured by computing areas under the receiver operating characteristic curve (AUROCs), calibration, and confusion matrix metrics (positive predictive value, sensitivity, and specificity) and was subjected to internal bootstrap validation. RESULTS: Of 479 patients (median age 64 years [IQR 55-71 years]; 58.7% male), 28.4% had complications after spine surgery. The in-hospital mortality rate was 1.9%, and the mean LOS was 7.8 days. The MSTFI demonstrated poor discrimination for predicting complications (AUROC 0.56, 95% CI 0.50-0.62) and in-hospital mortality (AUROC 0.69, 95% CI 0.54-0.85) in the validation cohort. For postoperative complications, machine learning approaches showed a greater advantage over the logistic regression model used to develop the MSTFI (AUROC 0.62, 95% CI 0.56-0.68 for random forest vs AUROC 0.56, 95% CI 0.50-0.62 for logistic regression). The random forest model had the highest positive predictive value (0.53, 95% CI 0.43-0.64) and the highest negative predictive value (0.77, 95% CI 0.72-0.81), with chronic lung disease, coagulopathy, anemia, and malnutrition identified as the most important predictors of postoperative complications. CONCLUSIONS: This study highlights the challenges of defining and quantifying frailty in the metastatic spine tumor population. Further study is required to improve the determination of surgical frailty in this specific cohort.


Asunto(s)
Fragilidad , Neoplasias de la Columna Vertebral , Adulto , Femenino , Fragilidad/diagnóstico , Humanos , Aprendizaje Automático , Masculino , Persona de Mediana Edad , Procedimientos Neuroquirúrgicos , Complicaciones Posoperatorias/etiología , Neoplasias de la Columna Vertebral/cirugía
4.
J Biomech Eng ; 142(9)2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32140715

RESUMEN

Subsidence of implants into bone is a major source of morbidity. The underlying mechanics of the phenomenon are not clear, but are likely related to interactions between contact stresses and the underlying porous trabecular bone structure. To gain insight into these interactions, we studied the penetration of three-dimensional (3D)-printed indenters with systematically varying geometries into Sawbones® foam substrates and isolated the effects of contact geometry from those of overall contact size and area. When size, contact area, and indented material stiffness and strength are controlled for, we show that resistance to penetration is in fact a function of topology only. Indenters with greater line contact lengths support higher subsidence loads in compression. These results have direct implications for the design of implants to resist subsidence into bone.


Asunto(s)
Fuerza Compresiva , Fusión Vertebral , Ensayo de Materiales , Porosidad , Prótesis e Implantes , Soporte de Peso
5.
Biomed Eng Online ; 13(1): 26, 2014 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-24618205

RESUMEN

BACKGROUND: The efficacy of dynamic anterior cervical plates is somewhat controversial. Screws in static-plate designs have a smaller diameter and can cut through bone under load. While not ideal, this unintended loosening can help mitigate stress shielding. Stand-alone interbody devices with integral fixation have large endplate contact areas that may inhibit or prevent loosening of the fixation. This study investigates the load sharing ability of a novel dynamic plate design in preventing the stress shielding of the graft material compared to the non-dynamic devices. METHODS: An experimentally validated intact C5-C6 finite element model was modified to simulate discectomy and accommodate implant-graft assembly. Four implant iterations were modeled; InterPlate titanium device with dynamic surface features (springs), InterPlate titanium non-dynamic device, InterPlate titanium design having a fully enclosed graft chamber, and the InterPlate design in unfilled PEEK having a fully enclosed graft chamber. All the models were fixed at the inferior-most surface of C6 and the axial displacement required to completely embed the dynamic surface features was applied to the model. RESULTS: InterPlate device with dynamic surface features induced higher graft stresses compared to the other design iterations resulting in uniform load sharing. The distribution of these graft stresses were more uniform for the InterPlate dynamic design. CONCLUSIONS: These results indicate that the dynamic design decreases the stress shielding by increasing and more uniformly distributing the graft stress. Fully enclosed graft chambers increase stress shielding. Lower implant material modulus of elasticity does not reduce stress shielding significantly.


Asunto(s)
Prótesis e Implantes , Fusión Vertebral/métodos , Ingeniería Biomédica/métodos , Placas Óseas , Trasplante Óseo , Vértebras Cervicales/patología , Elasticidad , Diseño de Equipo , Análisis de Elementos Finitos , Humanos , Fijadores Internos , Estrés Mecánico , Propiedades de Superficie , Titanio/química , Soporte de Peso
6.
J Biomech Eng ; 136(5): 051007, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24599026

RESUMEN

Currently, rigid fixation systems are the gold standard for degenerative disk disease treatment. Dynamic fixation systems have been proposed as alternatives for the treatment of a variety of spinal disorders. These systems address the main drawbacks of traditional rigid fixation systems, such as adjacent segment degeneration and instrumentation failure. Pedicle-screw-based dynamic stabilization (PDS) is one type of these alternative systems. The aim of this study was to simulate the biomechanical effect of a novel posterior dynamic stabilization system, which is comprised of dynamic (hinged) screws interconnected with a coiled, spring-based dynamic rod (DSDR), and compare it to semirigid (DSRR and RSRR) and rigid stabilization (RSRR) systems. A validated finite element (FE) model of L1-S1 was used to quantify the biomechanical parameters of the spine, such as range of motion, intradiskal pressure, stresses and facet loads after single-level instrumentation with different posterior stabilization systems. The results obtained from in vitro experimental intact and instrumented spines were used to validate the FE model, and the validated model was then used to compare the biomechanical effects of different fixation and stabilization constructs with intact under a hybrid loading protocol. The segmental motion at L4-L5 increased by 9.5% and 16.3% in flexion and left rotation, respectively, in DSDR with respect to the intact spine, whereas it was reduced by 6.4% and 10.9% in extension and left-bending loads, respectively. After instrumentation-induced intradiskal pressure at adjacent segments, L3-L4 and L5-S1 became less than the intact in dynamic rod constructs (DSDR and RSDR) except in the RSDR model in extension where the motion was higher than intact by 9.7% at L3-L4 and 11.3% at L5-S1. The facet loads were insignificant, not exceeding 12N in any of the instrumented cases in flexion. In extension, the facet load in DSDR case was similar to that in intact spine. The dynamic rod constructions (DSDR and RSDR) led to a lesser peak stress at screws compared with rigid rod constructions (DSRR and RSRR) in all loading cases. A dynamic construct consisting of a dynamic rod and a dynamic screw did protect the adjacent level from excessive motion.


Asunto(s)
Tornillos Óseos , Análisis de Elementos Finitos , Fenómenos Mecánicos , Fenómenos Biomecánicos , Degeneración del Disco Intervertebral/cirugía , Vértebras Lumbares/lesiones , Vértebras Lumbares/fisiología , Dinámicas no Lineales , Rango del Movimiento Articular
7.
J Biomech Eng ; 136(1): 011002, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24763546

RESUMEN

Multiple computational models have been developed to study knee biomechanics. However, the majority of these models are mainly validated against a limited range of loading conditions and/or do not include sufficient details of the critical anatomical structures within the joint. Due to the multifactorial dynamic nature of knee injuries, anatomic finite element (FE) models validated against multiple factors under a broad range of loading conditions are necessary. This study presents a validated FE model of the lower extremity with an anatomically accurate representation of the knee joint. The model was validated against tibiofemoral kinematics, ligaments strain/force, and articular cartilage pressure data measured directly from static, quasi-static, and dynamic cadaveric experiments. Strong correlations were observed between model predictions and experimental data (r > 0.8 and p < 0.0005 for all comparisons). FE predictions showed low deviations (root-mean-square (RMS) error) from average experimental data under all modes of static and quasi-static loading, falling within 2.5 deg of tibiofemoral rotation, 1% of anterior cruciate ligament (ACL) and medial collateral ligament (MCL) strains, 17 N of ACL load, and 1 mm of tibiofemoral center of pressure. Similarly, the FE model was able to accurately predict tibiofemoral kinematics and ACL and MCL strains during simulated bipedal landings (dynamic loading). In addition to minimal deviation from direct cadaveric measurements, all model predictions fell within 95% confidence intervals of the average experimental data. Agreement between model predictions and experimental data demonstrates the ability of the developed model to predict the kinematics of the human knee joint as well as the complex, nonuniform stress and strain fields that occur in biological soft tissue. Such a model will facilitate the in-depth understanding of a multitude of potential knee injury mechanisms with special emphasis on ACL injury.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Simulación por Computador , Análisis de Elementos Finitos , Traumatismos de la Rodilla/fisiopatología , Rodilla/patología , Rodilla/fisiopatología , Modelos Anatómicos , Fenómenos Biomecánicos , Humanos , Rango del Movimiento Articular , Análisis de Regresión , Rotación , Estrés Fisiológico , Soporte de Peso
8.
J Spinal Disord Tech ; 27(4): E118-27, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24869985

RESUMEN

STUDY DESIGN: A biomechanical finite element modeling study of the human lumbar spine. OBJECTIVE: To evaluate the effects of a transforaminal interbody device's footprint on lumbar spine biomechanics to further examine the potential subtle biomechanical differences not captured in previous studies. SUMMARY OF BACKGROUND DATA: In recent years, the evolution of interbody fusion devices has provided the surgeons with a multitude of options. An articulating transforaminal lumbar interbody fusion (TLIF) device is developed to overcome the surgical challenges associated with insertion of a large footprint interbody device through a small incision. METHODS: A finite element model of the L3-S1 lumbar segment was modified to simulate replacement of various TLIF constructs with different cage designs including an articulating vertebral interbody (AVID) TLIF device and a generic TLIF device placed in different configurations. The instrumented models were subjected to a 400 N follower load along with a 10 N m bending moment at different physiological planes. The kinematics, loads, and stresses were compared among various models. RESULTS: Simulated cage designs provided similar kinematical stability within the treated segments. However, the articulating and double TLIF implants allowed for better load sharing through the anterior column. These implants resulted in lower endplate and pedicle screw stresses and in more homogenous stress distribution across the peripheral region of the endplate. CONCLUSIONS: An articulating, large footprint, peripherally placed TLIF device affords substantial biomechanical advantages. This device may be able to reduce the incidence of subsidence because of its ability to reduce and distribute the endplate stresses in the stronger peripheral region. It may also reduce the posterior hardware failure incidence owing to its ability to reduce the screw stresses as compared with traditional TLIF. Although double TLIF has been demonstrated to have similar biomechanical advantages as the AVID, complications associated with double TLIF (ie, larger surgical incision, longer surgical procedure, placement and alignment challenges) support AVID as a better optimized alternative.


Asunto(s)
Vértebras Lumbares/fisiología , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Fenómenos Biomecánicos , Simulación por Computador , Análisis de Elementos Finitos , Humanos , Rango del Movimiento Articular/fisiología , Estrés Mecánico
9.
J Neurosurg Spine ; 40(1): 38-44, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37856396

RESUMEN

Finite element analysis (FEA) is a computer-based mathematical method commonly used in spine and orthopedic biomechanical research. Advances in computational power and engineering modeling and analysis software have enabled many recent technical applications of FEA. Through the use of FEA, a wide range of scenarios can be simulated, such as physiological processes, mechanisms of disease and injury, and the efficacy of surgical procedures. Such models have the potential to enhance clinical studies by allowing comparisons of surgical treatments that would be impractical to perform in human or animal studies, and by linking model results to treatment outcomes. While traditional ex vivo experiments are limited by variabilities in tissue, the complexity of test setup, cost, measurable biomechanical parameters, and the repeatability of experiments, FEA models can be used to measure a wide range of clinically relevant biomechanical parameters. Generic or patient-specific anatomical models can be modified to simulate different clinical and surgical conditions under simulated physiological conditions. Despite these capabilities, there is limited understanding of the clinical applicability and translational potential of FEA models. For spine surgeons, a comprehensive understanding of the key features, strengths, and limitations of FEA models of the spine and their ability to personalize treatment options and assist in clinical decision-making would significantly enhance the impact of FEA research. Furthermore, fostering collaborations between surgeons and engineers could augment the clinical use of these models. The purpose of this review was to highlight key features of FEA model building for clinicians. To illustrate these features, the authors present an example of the use of FEA models in comparing FDA-approved disc arthroplasty implants.


Asunto(s)
Programas Informáticos , Columna Vertebral , Animales , Humanos , Análisis de Elementos Finitos , Fenómenos Biomecánicos , Columna Vertebral/cirugía , Artroplastia
10.
Neurosurgery ; 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38940578

RESUMEN

BACKGROUND AND OBJECTIVES: Significant evidence has indicated that the reporting quality of novel predictive models is poor because of confounding by small data sets, inappropriate statistical analyses, and a lack of validation and reproducibility. The Transparent Reporting of a multivariable prediction model for Individual Prognosis or Diagnosis (TRIPOD) statement was developed to increase the generalizability of predictive models. This study evaluated the quality of predictive models reported in neurosurgical literature through their compliance with the TRIPOD guidelines. METHODS: Articles reporting prediction models published in the top 5 neurosurgery journals by SCImago Journal Rank-2 (Neurosurgery, Journal of Neurosurgery, Journal of Neurosurgery: Spine, Journal of NeuroInterventional Surgery, and Journal of Neurology, Neurosurgery, and Psychiatry) between January 1st, 2018, and January 1st, 2023, were identified through a PubMed search strategy that combined terms related to machine learning and prediction modeling. These original research articles were analyzed against the TRIPOD criteria. RESULTS: A total of 110 articles were assessed with the TRIPOD checklist. The median compliance was 57.4% (IQR: 50.0%-66.7%). Models using machine learning-based models exhibited lower compliance on average compared with conventional learning-based models (57.1%, 50.0%-66.7% vs 68.1%, 50.2%-68.1%, P = .472). Among the TRIPOD criteria, the lowest compliance was observed in blinding the assessment of predictors and outcomes (n = 7, 12.7% and n = 10, 16.9%, respectively), including an informative title (n = 17, 15.6%) and reporting model performance measures such as confidence intervals (n = 27, 24.8%). Few studies provided sufficient information to allow for the external validation of results (n = 26, 25.7%). CONCLUSION: Published predictive models in neurosurgery commonly fall short of meeting the established guidelines laid out by TRIPOD for optimal development, validation, and reporting. This lack of compliance may represent the minor extent to which these models have been subjected to external validation or adopted into routine clinical practice in neurosurgery.

11.
J Orthop Res ; 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39191523

RESUMEN

Conventional insertion torque and pull-out tests are destructive and unsuitable for clinical bone screw fixation. This study evaluates screw stability using acoustic modal analysis (AMA) and Periotest compared to traditional methods in an ex vivo animal model. Titanium self-tapping screws (STS) and nonself-tapping screws (N-STS) were implanted in the proximal tibia of 12 rabbits. Four testing methods were used to assess screw stability: peak insertion torque (PIT) during implantation, AMA for natural frequency (NF), Periotest for Periotest value (PTV), and pull-out test for peak pullout force (PPF). Euthanization was performed at 0 (primary stability), 4, and 8 weeks (secondary stability). No significant difference in primary stability was found between STS and N-STS except for AMA (STS: NF 2434 ± 67 Hz, N-STS: NF 2572 ± 43 Hz; p = 0.62). Secondary stability increased significantly over time for both screw types (4-week: NF 3687 ± 36 vs. 3408 ± 45 Hz, PTV 1.4 ± 1.6 vs. -1.5 ± 1.8, PPF 236 ± 29 vs. 220 ± 34 N; 8-week: NF 3890 ± 39 vs. 3613 ± 31 Hz, PTV -3.2 ± 2.5 vs. -2 ± 4.3, PPF 248 ± 25 vs. 289 ± 28 N). Higher NF values for given PTV/PPF indicate potential clinical advantages. Significant differences between primary and secondary stabilities suggest osteointegration was mainly achieved in the 4-week group.

12.
Neurosurgery ; 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38376173

RESUMEN

BACKGROUND AND OBJECTIVES: Epidural steroid injections (ESIs) are commonly used for lower back pain management. The effect of these injections on lumbar decompression surgery outcomes is hitherto underexplored. The study objective was to determine the impact of ESIs on postoperative rates of medical and surgical complications and to define the appropriate interval before lumbar decompression surgery. METHODS: This retrospective all-payer database analysis identified 587 651 adult patients undergoing one- to three-level laminectomies from January 2010 to October 2021. A 2:1 propensity score match accounting for comorbidities, levels of surgery, and demographics was performed to create two cohorts: (1) 43 674 patients who had received an ESI in the 90 days before laminectomy and (2) 87 348 patients who had not received an ESI. The primary outcome was the rates of medical and surgical complications between groups at 30 days postoperatively. Patients were divided into five cohorts based on injection time before surgery: 1 to 30 days, 31 to 45 days, 46 to 60 days, 61 to 75 days, and 76 to 90 days. Logistic regression was performed between groups to identify temporal associations of complication rates. Confidence intervals of 95% are provided when appropriate. P values < .01 were considered significant. RESULTS: Rates of medical complications within 30 days of surgery were significantly higher in those with ESI compared with control (4.83% vs 3.9%, P < .001). Cerebrospinal fluid (CSF) leak rates were increased in the ESI group at 0.28% vs 0.1% (P < .001), but surgical site infection rates were not significantly different between groups (1.31% vs 1.42% P = .11). ESI performed within 30 days was associated with increased odds of CSF leak (OR: 5.32, 95% CI: 3.96-7.15). CONCLUSION: Preoperative ESI increases the risk of CSF leak and medical complications after lumbar decompression. Because these complications were significantly associated with ESIs given 1 to 30 days before surgery, avoiding ESIs at least 30 days before surgery may be advisable.

13.
J Neurosurg Spine ; 41(2): 283-291, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38788228

RESUMEN

OBJECTIVE: Surgery for primary tumors of the mobile spine and sacrum often requires complex reconstruction techniques to cover soft-tissue defects and to treat wound and CSF-related complications. The anatomical, vascular, and immunoregulatory characteristics of the omentum make it an excellent local substrate for the management of radiation soft-tissue injury, infection, and extensive wound defects. This study describes the authors' experience in complex wound reconstruction using pedicled omental flaps to cover defects in surgery for mobile spine and sacral primary tumors. METHODS: A retrospective cohort analysis was conducted on 34 patients who underwent pedicled omental flap reconstruction after en bloc resection of primary sacral and mobile spine tumors between 2010 and 2020. The study focused on assessing the indications for omental flap usage, including soft-tissue coverage, protection against postoperative radiation therapy, infection management, vascular supply for bone grafts, and dural defect and CSF leak repair. Patient demographic characteristics, tumor characteristics, surgical outcomes, and follow-up data were analyzed to determine the procedure's efficacy and complication rates. RESULTS: From 2010 to 2020, 34 patients underwent pedicled omental flap reconstruction after en bloc resection of sacral (24 of 34 [71%]) and mobile spine (10 of 34 [29%]) primary tumors, mostly chordomas. The patient cohort included 21 men and 13 women with a median (range) age of 60 (32-89) years. The most common indication for omental flap was soft-tissue coverage (20 of 34 [59%]). Other indications included protecting abdominopelvic organs for postoperative radiation therapy (6 of 34 [18%]), treating infections (5 of 34 [15%]), providing vascular supply for free fibular bone graft (1 of 34 [3%]), and repairing large dural defects and CSF leak (2 of 34 [6%]). The median (range) follow-up was 24 (0-132) months, during which 71% (24 of 34) of patients did not require additional surgery for wound-related complications. At last follow-up, 59% (20 of 34) had stable disease and 32% (11 of 34) had recurrence, had progression of disease, or had been discharged to hospice after treatment. CONCLUSIONS: The pedicled omentum is an effective local tissue graft that can be used for complex wound reconstruction and management of high-risk closures in primary spine tumors. This technique may have a lower rate of complications than other approaches and may influence surgical planning and flap selection in challenging cases.


Asunto(s)
Epiplón , Procedimientos de Cirugía Plástica , Sacro , Neoplasias de la Columna Vertebral , Colgajos Quirúrgicos , Humanos , Masculino , Femenino , Neoplasias de la Columna Vertebral/cirugía , Persona de Mediana Edad , Epiplón/trasplante , Epiplón/cirugía , Sacro/cirugía , Procedimientos de Cirugía Plástica/métodos , Adulto , Estudios Retrospectivos , Anciano
14.
J Neurosurg Spine ; 40(3): 291-300, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38039533

RESUMEN

OBJECTIVE: The distributions and proportions of lean and fat tissues may help better assess the prognosis and outcomes of patients with spinal metastases. Specifically, in obese patients, sarcopenia may be easily overlooked as a poor prognostic indicator. The role of this body phenotype, sarcopenic obesity (SO), has not been adequately studied among patients undergoing surgical treatment for spinal metastases. To this end, here the authors investigated the role of SO as a potential prognostic factor in patients undergoing surgical treatment for spinal metastases. METHODS: The authors identified patients who underwent surgical treatment for spinal metastases between 2010 and 2020. A validated deep learning approach evaluated sarcopenia and adiposity on routine preoperative CT images. Based on composition analyses, patients were classified with SO or nonsarcopenic obesity. After nearest-neighbor propensity matching that accounted for confounders, the authors compared the rates and odds of postoperative complications, length of stay, 30-day readmission, and all-cause mortality at 90 days and 1 year between the SO and nonsarcopenic obesity groups. RESULTS: A total of 62 patients with obesity underwent surgical treatment for spinal metastases during the study period. Of these, 37 patients had nonsarcopenic obesity and 25 had SO. After propensity matching, 50 records were evaluated that were equally composed of patients with nonsarcopenic obesity and SO (25 patients each). Patients with SO were noted to have increased odds of nonhome discharge (OR 6.0, 95% CI 1.69-21.26), 30-day readmission (OR 3.27, 95% CI 1.01-10.62), and 90-day (OR 4.85, 95% CI 1.29-18.26) and 1-year (OR 3.78, 95% CI 1.17-12.19) mortality, as well as increased time to mortality after surgery (12.60 ± 19.84 months vs 37.16 ± 35.19 months, p = 0.002; standardized mean difference 0.86). No significant differences were noted in terms of length of stay or postoperative complications when comparing the two groups (p > 0.05). CONCLUSIONS: The SO phenotype was associated with increased odds of nonhome discharge, readmission, and postoperative mortality. This study suggests that SO may be an important prognostic factor to consider when developing care plans for patients with spinal metastases.


Asunto(s)
Sarcopenia , Neoplasias de la Columna Vertebral , Humanos , Sarcopenia/complicaciones , Neoplasias de la Columna Vertebral/complicaciones , Neoplasias de la Columna Vertebral/cirugía , Obesidad/complicaciones , Pronóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
15.
Neurosurgery ; 95(3): 576-583, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39145650

RESUMEN

BACKGROUND AND OBJECTIVES: Racial and socioeconomic disparities in spine surgery for degenerative lumbar spondylolisthesis persist in the United States, potentially contributing to unequal health-related quality of life (HRQoL) outcomes. This is important as lumbar spondylolisthesis is one of the most common causes of surgical low back pain, and low back pain is the largest disabler of individuals worldwide. Our objective was to assess the relationship between race, socioeconomic factors, treatment utilization, and outcomes in patients with lumbar spondylolisthesis. METHODS: This cohort study analyzed prospectively collected data from 9941 patients diagnosed with lumbar spondylolisthesis between 2015 and 2020 at 5 academic hospitals. Exposures were race, socioeconomic status, health coverage, and HRQoL measures. Main outcomes and measures included treatment utilization rates between racial groups and the association between race and treatment outcomes using logistic regression, adjusting for patient characteristics, socioeconomic status, health coverage, and HRQoL measures. RESULTS: Of the 9941 patients included (mean [SD] age, 67.37 [12.40] years; 63% female; 1101 [11.1%] Black, Indigenous, and People of Color [BIPOC]), BIPOC patients were significantly less likely to use surgery than White patients (odds ratio [OR] = 0.68; 95% CI, 0.62-0.75). Furthermore, BIPOC race was associated with significantly lower odds of reaching the minimum clinically important difference for physical function (OR = 0.74; 95% CI, 0.60; 0.91) and pain interference (OR = 0.77; 95% CI, 0.62-0.97). Medicaid beneficiaries were significantly less likely (OR = 0.65; 95% CI, 0.46-0.92) to reach a clinically important improvement in HRQoL when accounting for race. CONCLUSION: This study found that BIPOC patients were less likely to use spine surgery for degenerative lumbar spondylolisthesis despite reporting higher pain interference, suggesting an association between race and surgical utilization. These disparities may contribute to unequal HRQoL outcomes for patients with lumbar spondylolisthesis and warrant further investigation to address and reduce treatment disparities.


Asunto(s)
Disparidades en Atención de Salud , Vértebras Lumbares , Calidad de Vida , Espondilolistesis , Humanos , Espondilolistesis/cirugía , Espondilolistesis/etnología , Masculino , Femenino , Anciano , Persona de Mediana Edad , Disparidades en Atención de Salud/estadística & datos numéricos , Disparidades en Atención de Salud/etnología , Vértebras Lumbares/cirugía , Estudios de Cohortes , Estados Unidos , Etnicidad/estadística & datos numéricos , Resultado del Tratamiento , Dolor de la Región Lumbar/cirugía , Dolor de la Región Lumbar/etnología , Estudios Prospectivos , Factores Socioeconómicos
16.
J Biomech ; 155: 111635, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37216894

RESUMEN

The primary objective was to compare the subsidence resistance properties of a novel 3D-printed spinal interbody titanium implant versus a predicate polymeric annular cage. We evaluated a 3D-printed spinal interbody fusion device that employs truss-based bio-architectural features to apply the snowshoe principle of line length contact to provide efficient load distribution across the implant/endplate interface as means of resisting implant subsidence. Devices were tested mechanically using synthetic bone blocks of differing densities (osteoporotic to normal) to determine the corresponding resistance to subsidence under compressive load. Statistical analyses were performed to compare the subsidence loads and evaluate the effect of cage length on subsidence resistance. The truss implant demonstrated a marked rectilinear increase in resistance to subsidence associated with increase in the line length contact interface that corresponds with implant length irrespective of subsidence rate or bone density. In blocks simulating osteoporotic bone, comparing the shortest with the longest length truss cage (40 vs. 60 mm), the average compressive load necessary to induce subsidence of the implant increased by 46.4% (383.2 to 561.0 N) and 49.3% (567.4 to 847.2 N) for 1 and 2 mm of subsidence, respectively. In contrast, for annular cages, there was only a modest increase in compressive load when comparing the shortest with the longest length cage at a 1 mm subsidence rate. The Snowshoe truss cages demonstrated substantially more resistance to subsidence than corresponding annular cages. Clinical studies are required to support the biomechanical findings in this work.


Asunto(s)
Prótesis e Implantes , Fusión Vertebral , Columna Vertebral , Densidad Ósea , Presión , Vértebras Lumbares/cirugía
17.
J Neurosurg Spine ; 39(4): 557-567, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37439458

RESUMEN

OBJECTIVE: Surgery for metastatic spinal tumors can have a substantial impact on patients' quality of life by alleviating pain, improving function, and correcting spinal instability when indicated. The decision to operate is difficult because many patients with cancer are frail. Studies have highlighted the importance of preoperative nutritional status assessments; however, little is known about which aspects of nutrition accurately inform clinical outcomes. This study investigates the interaction and prognostic importance of various nutritional and frailty measures in patients with spinal metastases. METHODS: A retrospective analysis of consecutive patients who underwent surgery for spinal metastases between 2014 and 2020 at the Massachusetts General Hospital was performed. Patients were stratified according to the New England Spinal Metastasis Score (NESMS). Frailty was assessed using the metastatic spinal tumor frailty index. Nutrition was assessed using the prognostic nutritional index (PNI), preoperative body mass index, albumin, albumin-to-globulin ratio, and platelet-to-lymphocyte ratio. Outcomes included postoperative survival and complication rates, with focus on wound-related complications. RESULTS: This study included 154 individuals (39% female; mean [SD] age 63.23 [13.14] years). NESMS 0 and NESMS 3 demonstrated the highest proportions of severely frail patients (56.2%) and nonfrail patients (16.1%), respectively. Patients with normal nutritional status (albumin-to-globulin ratio and PNI) had a better prognosis than those with poor nutritional status when stratified by NESMS. Multivariable regression adjusted for NESMS and frailty showed that a PNI > 40.4 was significantly associated with decreased odds of 90-day complications (OR 0.93, 95% CI 0.85-0.98). After accounting for age, sex, primary tumor pathology, physical function, nutritional status, and frailty, a preoperative nutrition consultation was associated with a decrease in postoperative wound-related complications (average marginal effect -5.00%; 95% CI -1.50% to -8.9%). CONCLUSIONS: The PNI was most predictive of complications and may be a key biomarker for risk stratification in the 90 days following surgery. Nutrition consultation was associated with a reduced risk of wound-related complications, attesting to the importance of this preoperative intervention. These findings suggest that nutrition plays an important role in the postsurgical course and should be considered when developing a treatment plan for spinal metastases.

18.
Neurosurgery ; 92(1): 83-91, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36305664

RESUMEN

BACKGROUND: Breast cancer molecular features and modern therapies are not included in spine metastasis prediction algorithms. OBJECTIVE: To examine molecular differences and the impact of postoperative systemic therapy to improve prognosis prediction for spinal metastases surgery and aid surgical decision making. METHODS: This is a retrospective multi-institutional study of patients who underwent spine surgery for symptomatic breast cancer spine metastases from 2008 to 2021 at the Massachusetts General Hospital and Brigham and Women's Hospital. We studied overall survival, stratified by breast cancer molecular subtype, and calculated hazard ratios (HRs) adjusting for demographics, tumor characteristics, treatments, and laboratory values. We tested the performance of established models (Tokuhashi, Bauer, Skeletal Oncology Research Group, New England Spinal Metastases Score) to predict and compare all-cause. RESULTS: A total of 98 patients surgically treated for breast cancer spine metastases were identified (100% female sex; median age, 56 years [IQR, 36-84 years]). The 1-year probabilities of survival for hormone receptor positive, hormone receptor positive/human epidermal growth factor receptor 2+, human epidermal growth factor receptor 2+, and triple-negative breast cancer were 63% (45 of 71), 83% (10 of 12), 0% (0 of 3), and 12% (1 of 8), respectively ( P < .001). Patients with triple-negative breast cancer had a higher proportion of visceral metastases, brain metastases, and poor physical activity at baseline. Postoperative chemotherapy and endocrine therapy were associated with prolonged survival. The Skeletal Oncology Research Group prognostic model had the highest discrimination (area under the receiver operating characteristic, 0.77 [95% CI, 0.73-0.81]). The performance of all prognostic scores improved when preoperative molecular data and postoperative systemic treatment plans was considered. CONCLUSION: Spine metastases risk tools were able to predict prognosis at a significantly higher degree after accounting for molecular features which guide treatment response.


Asunto(s)
Neoplasias de la Mama , Neoplasias de la Columna Vertebral , Neoplasias de la Mama Triple Negativas , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Persona de Mediana Edad , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/patología , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Neoplasias de la Columna Vertebral/secundario
19.
JOR Spine ; 5(4): e1220, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36601373

RESUMEN

Background: Pilot hole preparation has been shown to have an impact on the short and long-term stability of the screw fixation constructs. Purpose: Investigation and comparison of two nondestructive modal analysis methods with conventional insertion torque (IT) and pullout tests in optimum pilot hole diameter detection. Methods: Twenty conical core titanium screws were embedded in high-density polyethylene blocks with different pilot hole diameters. The maximum IT was recorded for each screw during implantation. Then, two modal analysis methods including accelerometer (classical modal analysis [CMA]) and acoustic modal analysis (AMA) were carried out to measure the natural frequency (NF) of the bone-screw structure. Finally, stiffness (S), pullout force (Fult), displacement at Fult (dult) and energy dissipation (ED) were obtained from the destructive pullout test. Results: The IT increased, as the pilot hole diameter decreased. The maximum value of IT was observed in the smallest pilot hole diameter. The same trend was found for the Fult and the first NF derived from both modal methods except for 5.5 mm pilot hole diameter. The natural NFs derived from CMA and AMA showed high correlations in different groups (R2 = 0.94) and did not deviate from y = x hypothesis in linear regression analysis. The Fult, dult, and ED were measured 4800 ± 172 N, 3.10 ± 0.08 mm and 14.23 ± 1.10 N.mm, respectively. Discussion: No significant change was observed in "S" between the groups. The highest Fult and first NF were obtained for the 5.5 mm pilot hole diameter. Both CMA and AMA were found to be reliable methods and can promote the undesirable contradiction between Fult and IT.

20.
Spine (Phila Pa 1976) ; 47(7): E319-E327, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-34593736

RESUMEN

STUDY DESIGN: Finite element analysis (FEA) and in vivo ovine spinal interbody fusion study. OBJECTIVE: To determine comparative load-induced strain amplitudes, bone mineralization and fusion outcomes associated with different diameter struts in a truss-based interbody fusion device. SUMMARY OF BACKGROUND DATA: Additive manufacturing technology has been employed to develop implants that actively participate in the fusion process. The truss device enables the optimal transfer of compressive and tensile stresses via the struts. Mechanobiologic principles postulate that strut diameter can be regulated to allow different magnitudes of strain distribution within the struts which may affect fusion rates. METHODS: Modeling of strain distributions as a function of strut diameter (0.75, 1.0, 1.25, and 1.5 mm) employed FEA that simulated physiologic loading conditions. A confirmatory in vivo ovine lumbar spinal interbody fusion study compared fusion scores and bone histomorphometric variables for cages with 0.75 and 1.5 mm strut diameters. Outcomes were compared at 3-, 6-, and 12-month follow-up intervals. RESULTS: FEA showed an inverse association between strut diameter and peak strain amplitude. Cages with 1.0, 1.25, and 1.5 mm struts had peak strain values that were 36%, 60%, and 73% lower than the 0.75 mm strut strain value. In vivo results showed the mean fusion score for the 0.75 mm diameter strut cage was significantly greater by 3-months versus the 1.5 mm strut cage, and remained significantly higher at each subsequent interval (P < 0.001 for all comparisons). Fusion rates were 95%, 100%, and 100% (0.75 mm) and 72.7%, 86.4%, and 95.8% (1.5 mm) at 3, 6, and 12 months. Thinner struts had greater mineralized bone tissue and less fibrous/chondral tissue than the thicker struts at each follow-up. CONCLUSION: Validating FEA estimates, cages with smaller diameter struts exhibited more rapid fusion consolidation and more aggressive osseointegration compared with cages with larger diameters struts.Level of Evidence: 4.


Asunto(s)
Fusión Vertebral , Animales , Fenómenos Biomecánicos , Calcificación Fisiológica , Análisis de Elementos Finitos , Humanos , Vértebras Lumbares/cirugía , Ovinos , Fusión Vertebral/métodos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda