Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Paediatr Child Health ; 57(9): 1485-1489, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33938084

RESUMEN

AIM: Skin breaks (SBs) for procedures and blood sampling are common in neonatal intensive care units (NICU), contributing to pain, infection risk and anaemia. We aimed to document their prevalence, identify areas for improvement and, through staff awareness, reduce their frequency. METHODS: Quality improvement project via prospective audit at a tertiary-level NICU in Australia was conducted. All infants admitted to the NICU for >24 h during two audit periods were included in the study. A specifically designed bedside audit tool was used to prospectively document all SB and blood tests performed on infants during a 4-week audit period (audit 1). Results were reviewed to identify areas for improvement, and disseminated to staff at unit meetings, shift handover and email. Following education and awareness, the audit was repeated (audit 2), and data were compared. Frequency of SB and blood tests performed was measured. Data were tested for normality and analysed using parametric or non-parametric tests where appropriate. RESULTS: There were 52 NICU admissions during each audit period (104 total), with 34 (65%) and 31 (60%) having audit sheets completed, respectively. Median (interquartile range) gestational age and mean (standard deviation) birthweight were 29 (26.3-35) weeks and 1836 (1185) g for audit 1, 30 (28.5-31.5) weeks and 1523 (913) g for audit 2. The reduction in total blood tests (mean) was 36.3%, skin breaks per admitted baby day reduced by 60% and total blood volume sampled (mean) by 37.7%. CONCLUSIONS: A quality improvement project by prospective audit and staff education was associated with reductions in frequency of skin breaks and blood tests in the NICU.


Asunto(s)
Unidades de Cuidado Intensivo Neonatal , Cuidado Intensivo Neonatal , Peso al Nacer , Edad Gestacional , Pruebas Hematológicas , Humanos , Lactante , Recién Nacido
2.
J Paediatr Child Health ; 57(6): 913-919, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33486799

RESUMEN

AIM: To determine predictors and outcomes of extubation failure in extremely preterm (EP) infants born <28 weeks' gestational age (GA). METHODS: Retrospective clinical audit across two tertiary-level neonatal intensive care units in Melbourne, Australia. Two-hundred and four EP infants who survived to their first extubation from mechanical ventilation. Extubation failure (re-intubation) within 7 days after the first extubation. RESULTS: Lower GA (odds ratio [OR] 0.71, 95% confidence interval (CI), 0.61-0.89, P < 0.001) and higher pre-extubation measured mean airway pressure (MAP) on the mechanical ventilator (OR 1.9 [95% CI 1.41-2.51], P < 0.001) predicted extubation failure. The area under a receiver operating characteristic curve for GA and MAP was 0.77 (95% CI 0.70-0.82). After adjustment for GA, infants who experienced extubation failure had higher rates of bronchopulmonary dysplasia (P < 0.001), post-natal systemic corticosteroid treatment (P < 0.001), airway trauma (P < 0.003), longer durations of treatment with mechanical ventilation (P < 0.001), non-invasive respiratory support (P < 0.001), supplemental oxygen therapy (P = 0.05) and longer hospitalisation (P = 0.025). CONCLUSIONS: Lower GA and higher pre-extubation measured MAP were predictive of extubation failure within 7 days in extremely preterm infants. Extubation failure was associated with increased morbidity and extended periods of respiratory support and hospitalisation.


Asunto(s)
Extubación Traqueal , Recien Nacido Extremadamente Prematuro , Australia , Humanos , Lactante , Recién Nacido , Respiración Artificial , Estudios Retrospectivos
3.
Lancet Child Adolesc Health ; 7(12): 844-851, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-38240784

RESUMEN

BACKGROUND: Extremely preterm infants often require invasive mechanical ventilation, and clinicians aim to extubate these infants as soon as possible. However, extubation failure occurs in up to 60% of extremely preterm infants and is associated with increased mortality and morbidity. Nasal continuous positive airway pressure (nCPAP) is the most common post-extubation respiratory support, but there is no consensus on the optimal nCPAP level to safely avoid extubation failure in extremely preterm infants. We aimed to determine if higher nCPAP levels compared with standard nCPAP levels would decrease rates of extubation failure in extremely preterm infants within 7 days of their first extubation. METHODS: In this multicentre, randomised, open-label controlled trial done at three tertiary perinatal centres in Australia, we assigned extremely preterm infants to extubation to either higher nCPAP (10 cmH2O) or standard nCPAP (7 cmH2O). Infants were eligible if they were born at less than 28 weeks' gestation, were receiving mechanical ventilation via an endotracheal tube, and were being extubated for the first time to nCPAP. Eligible infants must have received previous treatment with exogenous surfactant and caffeine. Infants were ineligible if they were planned to be extubated to a mode of respiratory support other than nCPAP, if they had a known major congenital anomaly that might affect breathing, or if ongoing intensive care was not being provided. Parents or guardians provided prospective, written, informed consent. Infants were maintained within an assigned nCPAP range for a minimum of 24 h after extubation (higher nCPAP group 9-11 cmH2O and standard nCPAP group 6-8 cmH2O). Randomisation was stratified by both gestation (22-25 completed weeks or 26-27 completed weeks) and recruiting centre. The primary outcome was extubation failure within 7 days and analysis was by intention to treat. This trial was prospectively registered with the Australian New Zealand Clinical Trials Registry, number ACTRN12618001638224. FINDINGS: Between March 3, 2019, and July 31, 2022, 483 infants were born at less than 28 weeks and admitted to the recruiting centres. 92 infants were not eligible, 172 were not approached, 65 families declined to participate, and 15 consented but were not randomly assigned. 139 infants were enrolled and randomly assigned, 70 to the higher nCPAP group and 69 to the standard nCPAP group. One infant in the higher nCPAP group was excluded from the analysis because consent was withdrawn after randomisation. 104 (75%) of 138 mothers were White. The mean gestation was 25·7 weeks (SD 1·3) and the mean birthweight was 777 grams (201). 70 (51%) of 138 infants were female. Extubation failure occurred in 24 (35%) of 69 infants in the higher nCPAP group and in 39 (57%) of 69 infants in the standard nCPAP group (risk difference -21·7%, 95% CI -38·5% to -3·7%). There were no significant differences in rates of adverse events between groups during the primary outcome period. Three patients died (two in the higher nCPAP group and one in the standard nCPAP group), pneumothorax occurred in one patient from each group, spontaneous intestinal perforation in three patients (two in the higher nCPAP group and one in the standard nCPAP group) and there were no events of pulmonary interstitial emphysema. INTERPRETATION: Extubation of extremely preterm infants to higher nCPAP significantly reduced extubation failure compared with extubation to standard nCPAP, without increasing rates of adverse effects. Future larger trials are essential to confirm these findings in terms of both efficacy and safety. FUNDING: National Health and Medical Research Council Centre for Research Excellence in Newborn Medicine, number 1153176.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua , Recien Nacido Extremadamente Prematuro , Recién Nacido , Humanos , Femenino , Masculino , Extubación Traqueal , Estudios Prospectivos , Australia
4.
BMJ Open ; 11(6): e045897, 2021 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-34162644

RESUMEN

INTRODUCTION: Respiratory distress syndrome is a complication of prematurity and extremely preterm infants born before 28 weeks' gestation often require endotracheal intubation and mechanical ventilation. In this high-risk population, mechanical ventilation is associated with lung injury and contributes to bronchopulmonary dysplasia. Therefore, clinicians attempt to extubate infants as quickly and use non-invasive respiratory support such as nasal continuous positive airway pressure (CPAP) to facilitate the transition. However, approximately 60% of extremely preterm infants experience 'extubation failure' and require reintubation. While CPAP pressures of 5-8 cm H2O are commonly used, the optimal CPAP pressure is unknown, and higher pressures may be beneficial in avoiding extubation failure. Our trial is the Extubation CPAP Level Assessment Trial (ÉCLAT). The aim of this trial is to compare higher CPAP pressures 9-11 cm H2O with a current standard pressures of 6-8 cmH2O on extubation failure in extremely preterm infants. METHODS AND ANALYSIS: 200 extremely preterm infants will be recruited prior to their first extubation from mechanical ventilation to CPAP. This is a parallel group randomised controlled trial. Infants will be randomised to one of two set CPAP pressures: CPAP 10 cmH2O (intervention) or CPAP 7 cmH2O (control). The primary outcome will be extubation failure (reintubation) within 7 days. Statistical analysis will follow standard methods for randomised trials on an intention to treat basis. For the primary outcome, this will be by intention to treat, adjusted for the prerandomisation strata (GA and centre). We will use the appropriate parametric and non-parametric statistical tests. ETHICS AND DISSEMINATION: Ethics approval has been granted by the Monash Health Human Research Ethics Committees. Amendments to the trial protocol will be submitted for approval. The findings of this study will be written into a clinical trial report manuscript and disseminated via peer-reviewed journals (on-line or in press) and presented at national and international conferences.Trial registration numberACTRN12618001638224; pre-results.


Asunto(s)
Displasia Broncopulmonar , Síndrome de Dificultad Respiratoria del Recién Nacido , Extubación Traqueal , Displasia Broncopulmonar/prevención & control , Presión de las Vías Aéreas Positiva Contínua , Humanos , Lactante , Recien Nacido Extremadamente Prematuro , Recién Nacido , Ensayos Clínicos Controlados Aleatorios como Asunto , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda