Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Prague Med Rep ; 124(4): 444-448, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38069649

RESUMEN

Mucormycosis is a rare invasive fungal disease diagnosed in immunocompromised patients, including those with diabetes or iron overload, and in patients treated for hematological malignancies or after transplantation. Isavuconazole is a triazole antifungal effective against Mucorales with good tolerability, but with potential for relatively high interindividual variability in pharmacokinetics. This report demonstrates the case of a lung transplant recipient treated with isavuconasole that exhibits a very long elimination half-life of 159 hours, and discusses the practical implications of this finding for dosage adjustment and need for therapeutic drug monitoring.


Asunto(s)
Aspergilosis , Mucormicosis , Humanos , Receptores de Trasplantes , Monitoreo de Drogas , Aspergilosis/tratamiento farmacológico , Triazoles/uso terapéutico , Triazoles/farmacocinética , Mucormicosis/diagnóstico , Mucormicosis/tratamiento farmacológico , Pulmón
2.
Clin Lab ; 64(11)2018 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-30549990

RESUMEN

Background: Many studies have reported higher values of urinary albumin measured by high performance liquid chromatography (HPLC) in comparison with immunochemical methods. The aims of our study were the implementation of the HPLC method for albuminuria, testing the hypothesis about coeluting proteins, comparison of albuminuria assessed by HPLC and immunoturbidimetric (IT) methods in diabetic and non-diabetic patient samples. Methods: We compared albuminuria assessed by HPLC with albuminuria assessed by the IT method in fresh urine samples of 636 diabetics and 456 non-diabetics. We investigated relationships between albuminuria and blood glycated hemoglobin HbA1c. Results: We found significant differences between the parameters of linear regressions between albuminuria determined using HPLC and IT among patients with and without DM, and even between patients with DM type 1 and type 2. We confirmed the underestimation of albuminuria assessed by IT. We did not reveal any significant correlation between blood glycated hemoglobin and any of the parameters derived from albuminuria. Conclusions: We excluded non-specificity of the HPLC method. Despite of a little bit lower analytical sensitivity of the HPLC method in comparison with IT method the diagnostic sensitivity of HPLC method is higher, because it measures the total albuminuria (immunoreactive plus immunounreactive). We developed three formulas (for nondiabetics, for diabetics type 1 and diabetics type 2) for the estimation of the total albuminuria from IT values. We also confirmed that albuminuria and HbA1c are independent biomarkers.


Asunto(s)
Albúminas/análisis , Albuminuria/orina , Cromatografía Líquida de Alta Presión/métodos , Inmunoturbidimetría/métodos , Adulto , Anciano , Albuminuria/diagnóstico , Creatinina/orina , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/orina , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/orina , Femenino , Hemoglobina Glucada/orina , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
3.
J Clin Lab Anal ; 32(5): e22381, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29333616

RESUMEN

BACKGROUND: New high-performance liquid chromatography (HPLC) method was developed for the determination of vitamin K1 and two forms of vitamin K2 (MK-4 and MK-7) in human serum, and the levels of vitamin K were determined in 350 samples of postmenopausal women. METHODS: Vitamin K was determined by HPLC with fluorescence detection after postcolumn zinc reduction. The detection was performed at 246 nm (excitation) and 430 nm (emission). The internal standard and 2 mL of ethanol were added to 500 µL of serum. The mixture was extracted with 4 mL of hexane, and solid phase extraction was then used. RESULTS: The HLPC method was fully validated. The intra- and interday accuracy and precision were evaluated on two QC samples by multiple analysis, and CV were less than 10%. The limit of quantification for MK-4 was found at 0.04 ng/mL, for K1 0.03 ng/mL, and for MK-7 0.03 ng/mL. The mean recoveries of the corresponding compounds were 98%-110%. Serum levels of MK-4, K1 , and MK-7 in postmenopausal women with osteoporosis were 0.890 ± 0.291 ng/mL, 0.433 ± 0.394 ng/mL, and 1.002 ± 1.020 ng/mL, respectively (mean ± SD). Serum levels of MK-4, K1 , and MK-7 in postmenopausal women without osteoporosis were 0.825 ± 0.266 ng/mL, 0.493 ± 0.399 ng/mL, and 1.186 ± 1.076 ng/mL, respectively (mean ± SD). CONCLUSION: New HPLC method for the determination of vitamins K1 , MK-4, and MK-7 in serum was evaluated and validated. This method is highly specific and sensitive with the low limit of quantification.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Fluorescencia , Posmenopausia/sangre , Vitamina K 1/sangre , Vitamina K 2/sangre , Femenino , Humanos , Factores de Tiempo , Vitamina K 2/clasificación
4.
Clin Lab ; 63(2): 385-388, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-28182348

RESUMEN

BACKGROUND: Three immunochemical methods for the determination of 25-(OH)-vitamin D and validated HPLC method for the determination of 25-(OH)-vitamin D3 and 25-(OH)-vitamin D2 were compared. 62 patient samples from postmenopausal women were measured and the results obtained by all these methods were compared. METHODS: We used three chemiluminescent assays for determination of 25-(OH)-vitamin D. 25-(OH)-vitamin D3 and 25-(OH)-vitamin D2 were determined by HPLC with UV detection (Agilent 1200). The chemiluminescent assays were performed using the Abbott Architect i4000SR analyzer (Abbott Laboratories, Germany), the ADVIA Centaur (Siemens, USA), and the Liaison XL (DiaSorin Inc, USA). The statistical evaluation was done using GraphPad Prism 6.0. RESULTS: The data were tested by Tukey's multiple comparison test. All methods showed significant differences in comparison with the immunochemical method from DiaSorin (p < 0.001 for Abbott, p < 0.05 for Siemens, and p < 0.0001 for HPLC). The comparison of the immunochemical method from Siemens with HPLC was also significant, p < 0.05. The mean of DiaSorin measurements was 38% lower than the mean of HPLC measurements. The non-significant difference was shown by the comparison of Abbott with HPLC and also Abbott with Siemens. Means for the 25-(OH)-vitamin D methods used were: Abbott 70.2 ± 24.2 nmol/L, Siemens 67.6 ± 27.9 nmol/L, DiaSorin 53.5 ± 17.1, and HPLC 82.4 ± 40.0 nmol/L. CONCLUSIONS: The comparison of the DiaSorin immunochemical assay with other tested methods showed the greatest deviation. The mean of DiaSorin measurements was 38% lower than the mean of HPLC measurements. According to the results of the DiaSorin method, most patients treated with vitamin D would not achieve the optimal level of 25-(OH)-vitamin D and this could negatively affect the clinical decision.


Asunto(s)
25-Hidroxivitamina D 2/sangre , Calcifediol/sangre , Cromatografía Líquida de Alta Presión , Técnica del Anticuerpo Fluorescente Directa , Técnica del Anticuerpo Fluorescente Indirecta , Posmenopausia/sangre , Vitamina D/análogos & derivados , Biomarcadores/sangre , Femenino , Humanos , Mediciones Luminiscentes , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Espectrofotometría Ultravioleta , Vitamina D/sangre
5.
J Clin Lab Anal ; 30(6): 1226-1231, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27241883

RESUMEN

BACKGROUND: A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. METHODS: Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA® 400, Roche Diagnostics GmbH, Manheim, Germany. RESULTS: The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). CONCLUSION: New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry.


Asunto(s)
Albúminas/análisis , Albuminuria/orina , Cromatografía Líquida de Alta Presión , Femenino , Humanos , Masculino , Factores de Tiempo , Urinálisis
6.
J Chemother ; 36(1): 35-44, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37272077

RESUMEN

This study aimed to explore pharmacokinetics of voriconazole and its covariates in lung transplant recipients using population approach in order to propose dosing individualization. Data from routine therapeutic drug monitoring in adult lung transplant recipients treated with oral voriconazole were analysed with a three-stage population pharmacokinetic model using nonlinear mixed-effects modelling. Monte Carlo simulations based on final voriconazole pharmacokinetic model were used to generate the theoretical distribution of pharmacokinetic profiles at various dosing regimens. A total of 78 voriconazole serum concentrations collected from 40 patients were included in pharmacokinetic analysis. The only significant covariate was age for voriconazole clearance. Population voriconazole apparent clearance started at 32.26 L/h and decreased by 0.021 L/h with each year of patient's age, while population apparent volume of distribution was 964.46 L. Based on this model, we have proposed an easy-to-use dosing regimen consisting of a loading dose of 400 mg every 12 h for the first 48 h of treatment followed by maintenance dose of 300 mg every 12 h in patients aged up to 59 years, or by maintenance dose of 200 mg every 12 h in patients aged above 59 years.


Asunto(s)
Monitoreo de Drogas , Receptores de Trasplantes , Adulto , Humanos , Anciano , Voriconazol/farmacocinética , Método de Montecarlo , Pulmón , Modelos Biológicos
7.
Artículo en Inglés | MEDLINE | ID: mdl-38869776

RESUMEN

Lyme arthritis, one of the possible late manifestations of Lyme borreliosis, predominantly affects the supporting joints and in adults most often occurs in the form of monoarthritis of the knee. Early diagnosis is based on clinical findings and serology. PCR detection of Borrelia in synovial fluid has become an integral part of the laboratory testing algorithm. The clinical presentation and inflammatory markers in Lyme arthritis can resemble septic arthritis. Determining the levels of alpha-defensins (human neutrophil peptide (HNP 1-3)) in synovial fluid by liquid chromatography is a highly sensitive method revealing the presence of inflammatory process. Between 2020 and 2022, we examined eleven patients with Lyme arthritis of the knee. We measured levels of HNP 1-3 from synovial fluid by HPLC in patients, and we compared it with the corresponding C-reactive protein (CRP) levels in paired serum samples. In patients diagnosed with Lyme arthritis, HNP 1-3 levels in synovial fluid ranged from 2.5 to 261 mg/L, with a median of 46.5 mg/L. Average serum CRP was 43 mg/L. The results show that elevated HNP 1-3 can be consistent with not only septic arthritis or systemic disease, but also with Lyme arthritis, especially in patients with negative culture and 16S PCR from synovial fluid. Final diagnosis must be verified by examination for anti-Borrelia antibodies from serum and synovial fluid. The aim of this work is to introduce an HPLC method for the determination of alpha-defensins as one of the possible diagnostic markers.

8.
Spectrochim Acta A Mol Biomol Spectrosc ; 322: 124689, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38996762

RESUMEN

Creatinine is the end product of the catabolism of creatine and creatine phosphate. Creatine phosphate serves as a reservoir of high-energy phosphate, especially in skeletal and cardiac muscle. Besides typical known changes in serum and urinary creatinine concentrations, rare cases associated with changes in serum and urinary creatine levels have been described in the literature in humans. These cases are mostly linked to an excessive intake of creatine ethyl ester or creatine monohydrate, often resulting in increased urine creatinine concentrations. In addition, it is known that at such elevated creatinine concentrations, creatinine crystallisation may occur in the urine. Analysis of crystals and urinary concrements, often of heterogenous chemical composition, may provide diagnostic and therapeutic hints to the benefit of the patient. The aim of the present work was to analyze urine crystals of unclear composition with microscopic and spectroscopic techniques. On routine microscopic analysis of urine, a preliminary suspicion of uric acid or creatinine crystals was expressed. The crystals were of a cuboid shape and showed polarization effects in microscopy. The dried urine sample was whitish-orange in colour, odourless and dissolved well in water. Protein concentration in dry weight (DW) urine was about 0.3 mg/mg. The measured zinc content in the studied sample was approximately 660 µg/g DW sample and copper content was approximately 64 µg/g DW sample. A lead signal of around 10 µg/g DW sample was also observed. UV-Vis analysis showed a maximum creatine peak around 220 nm, compatible with the spectrum of creatinine with a maximum peak of 230 nm. Using HPLC technique, an extreme high ratio of creatine to creatinine of about 38 was measured, which led to the conclusion of the occurrence of rare creatine crystals in urine.

9.
Crit Rev Anal Chem ; : 1-30, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38753964

RESUMEN

Due to their life cycle, viruses can disrupt the metabolism of their hosts, causing diseases. If we want to disrupt their life cycle, it is necessary to identify their presence. For this purpose, it is possible to use several molecular-biological and bioanalytical methods. The reference selection was performed based on electronic databases (2020-2023). This review focused on electrochemical methods with high sensitivity and selectivity (53% voltammetry/amperometry, 33% impedance, and 12% other methods) which showed their great potential for detecting various viruses. Moreover, the aforementioned electrochemical methods have considerable potential to be applicable for care-point use as they are portable due to their miniaturizability and fast speed analysis (minutes to hours), and are relatively easy to interpret. A total of 2011 articles were found, of which 86 original papers were subsequently evaluated (the majority of which are focused on human pathogens, whereas articles dealing with plant pathogens are in the minority). Thirty-two species of viruses were included in the evaluation. It was found that most of the examined research studies (77%) used nanotechnological modifications. Other ones performed immunological (52%) or genetic analyses (43%) for virus detection. 5% of the reports used peptides to increase the method's sensitivity. When evaluable, 65% of the research studies had LOD values in the order of ng or nM. The vast majority (79%) of the studies represent proof of concept and possibilities with low application potential and a high need of further research experimental work.

10.
Nutrients ; 16(9)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38732584

RESUMEN

The available evidence on vitamin K status in cystic fibrosis (CF) is scarce, lacking data on vitamin K2 (menaquinones-MK). Therefore, we assessed vitamin K1, MK-4 and MK-7 concentrations (LC-MS/MS) in 63 pancreatic insufficient and modulator naïve CF patients, and compared to 61 healthy subjects (HS). Vitamin K1 levels did not differ between studied groups. MK-4 concentrations were higher (median <1st-3rd quartile>: 0.778 <0.589-1.086> vs. 0.349 <0.256-0.469>, p < 0.0001) and MK-7 levels lower (0.150 <0.094-0.259> vs. 0.231 <0.191-0.315>, p = 0.0007) in CF patients than in HS. MK-7 concentrations were higher in CF patients receiving K1 and MK-7 supplementation than in those receiving vitamin K1 alone or no supplementation. Moreover, vitamin K1 concentrations depended on the supplementation regime. Based on multivariate logistic regression analysis, we have found that MK-7 supplementation dose has been the only predictive factor for MK-7 levels. In conclusion, vitamin K1 levels in CF are low if not currently supplemented. MK-4 concentrations in CF patients supplemented with large doses of vitamin K1 are higher than in HS. MK-7 levels in CF subjects not receiving MK-7 supplementation, with no regard to vitamin K1 supplementation, are low. There do not seem to be any good clinical predictive factors for vitamin K status.


Asunto(s)
Fibrosis Quística , Protrombina , Vitamina K 1 , Vitamina K 2 , Humanos , Fibrosis Quística/sangre , Femenino , Masculino , Vitamina K 2/sangre , Vitamina K 2/análogos & derivados , Estudios Transversales , Protrombina/análisis , Adolescente , Adulto , Vitamina K 1/administración & dosificación , Vitamina K 1/sangre , Adulto Joven , Estado Nutricional , Suplementos Dietéticos , Deficiencia de Vitamina K/sangre , Vitamina K/sangre
11.
Antibiotics (Basel) ; 12(9)2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37760696

RESUMEN

Although posaconazole tablets show relatively low variability in pharmacokinetics (PK), the proportion of patients achieving the PK/PD target at the approved uniform dose for both prophylaxis and therapy is not satisfactory. The aim of this study was to develop a posaconazole population PK model in lung-transplant recipients and to propose a covariate-based dosing optimization for both prophylaxis and therapy. In this prospective study, 80 posaconazole concentrations obtained from 32 lung-transplant patients during therapeutic drug monitoring were analyzed using nonlinear mixed-effects modelling, and a Monte Carlo simulation was used to describe the theoretical distribution of posaconazole PK profiles at various dosing regimens. A one-compartment model with both linear absorption and elimination best fit the concentration-time data. The population apparent volume of distribution was 386.4 L, while an apparent clearance of 8.8 L/h decreased by 0.009 L/h with each year of the patient's age. Based on the covariate model, a dosing regimen of 200 mg/day for prophylaxis in patients ˃60 years, 300 mg/day for prophylaxis in patients ˂60 years and for therapy in patients ˃60 years, and 400 mg/day for therapy in patients ˂60 years has been proposed. At this dosing regimen, the PK/PD target for prophylaxis and therapy is reached in 95% and 90% of population, respectively, representing significantly improved outcomes in comparison with the uniform dose.

12.
Pharmaceutics ; 14(2)2022 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-35214140

RESUMEN

The aim of this prospective study was to evaluate the pharmacokinetics of ganciclovir in lung transplant recipients, to explore its covariates, and to propose an individualized dosing regimen. Ganciclovir was administered according to the protocol in a standardized intravenous dose of 5 mg/kg twice daily. Serum ganciclovir concentrations were monitored as a trough and at 3 and 5 h after dosing. Individual ganciclovir pharmacokinetic parameters were calculated in a two-compartmental pharmacokinetic model, while regression models were used to explore the covariates. Optimal loading and maintenance doses were calculated for each patient. In lung transplant recipients (n = 40), the median (IQR) ganciclovir total volume of distribution and clearance values were 0.65 (0.52-0.73) L/kg and 0.088 (0.059-0.118) L/h/kg, respectively. We observed medium-to-high inter-individual but negligible intra-individual variability in ganciclovir pharmacokinetics. The volume of distribution of ganciclovir was best predicted by height, while clearance was predicted by glomerular filtration rate. Bodyweight-normalized clearance was significantly higher in patients with cystic fibrosis, while distribution half-life was reduced in this subgroup. On the basis of the observed relationships, practical nomograms for individualized ganciclovir dosing were proposed. The dosing of ganciclovir in patients with cystic fibrosis requires special caution, as their daily maintenance dose should be increased by approximately 50%.

13.
Clin Lab ; 57(7-8): 599-606, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21888024

RESUMEN

BACKGROUND: A modified high performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of methotrexate (MTX) and its main metabolite 7-hydroxymethotrexate (7-OHMTX) and compared to the immunochemical fluorescence polarization immunoassay (FPIA2) determination of methotrexate. METHODS: Methotrexate was determined by HPLC with UV detection at 303 nm after precipitation of proteins with trichloroacetic acid. Fluorescence polarization immunoassays (FPIA2) of methotrexate were performed on the TDx FLx Immunoassay Analyzer. RESULTS: Our data indicate good correlation between methotrexate levels > 1 micromol/L determined by HPLC and FPIA2. (r = 0.94, Spearman correlation coefficient). However, concentrations of methotrexate < 1 micromol/L measured by fluorescence polarization immunoassay were overestimated. CONCLUSIONS: The concentration of MTX < 1 micromol/L are overestimated due to the cross reactivity with metabolites 7-OHMTX and 2,4-diamino-N10-methylpteroic acid (DAMPA). The cross reaction may affect the therapy and lead to relapse in children with acute lymphoblastic leukemia.


Asunto(s)
Antimetabolitos Antineoplásicos/sangre , Cromatografía Líquida de Alta Presión/métodos , Monitoreo de Drogas/métodos , Metotrexato/análogos & derivados , Metotrexato/sangre , Adolescente , Antimetabolitos Antineoplásicos/farmacocinética , Biotransformación , Neoplasias Óseas/sangre , Neoplasias Óseas/tratamiento farmacológico , Niño , Inmunoensayo de Polarización Fluorescente , Humanos , Metotrexato/análisis , Metotrexato/farmacocinética , Osteosarcoma/sangre , Osteosarcoma/tratamiento farmacológico , Leucemia-Linfoma Linfoblástico de Células Precursoras/sangre , Leucemia-Linfoma Linfoblástico de Células Precursoras/tratamiento farmacológico , Adulto Joven
14.
Cas Lek Cesk ; 150(8): 451-6, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22026081

RESUMEN

Epilepsy is a serious health disorder affecting both paediatric and adult population worldwide. Due to difficulties in identifying its aetiology, initial management is often guided by empiric therapy measures. Symptomatic control requires the use of antiepileptic drugs (AEDs), many of which have the potential for adverse drug interactions. Children are especially susceptible to drug interactions and frequently exhibit atypical adverse events, which may require special care. Aim. To demonstrate a case of a 15 year old girl suffering from refractory epilepsy with underlying focal cortical dysplasia (FCD), whose seizure deterioration was most probably associated with drug-drug interactions between prescribed common antiepileptic drugs, namely valproic acid, phenobarbital or the prodrug primidon and carbamazepine.


Asunto(s)
Anticonvulsivantes/efectos adversos , Epilepsia/tratamiento farmacológico , Adolescente , Encéfalo/anomalías , Carbamazepina/efectos adversos , Interacciones Farmacológicas , Quimioterapia Combinada , Epilepsia/complicaciones , Femenino , Humanos , Fenobarbital/efectos adversos , Primidona/efectos adversos , Ácido Valproico/efectos adversos
15.
Biomedicines ; 9(5)2021 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-34068788

RESUMEN

The aim of the study was to develop an orthopedic implant coating in the form of vancomycin-loaded collagen/hydroxyapatite layers (COLHA+V) that combine the ability to prevent bone infection with the ability to promote enhanced osseointegration. The ability to prevent bone infection was investigated employing a rat model that simulated the clinically relevant implant-related introduction of bacterial contamination to the bone during a surgical procedure using a clinical isolate of Staphylococcus epidermidis. The ability to enhance osseointegration was investigated employing a model of a minipig with terminated growth. Six weeks following implantation, the infected rat femurs treated with the implants without vancomycin (COLHA+S. epidermidis) exhibited the obvious destruction of cortical bone as evinced via a cortical bone porosity of up to 20% greater than that of the infected rat femurs treated with the implants containing vancomycin (COLHA+V+S. epidermidis) (3%) and the non-infected rat femurs (COLHA+V) (2%). The alteration of the bone structure of the infected COLHA+S. epidermidis group was further demonstrated by a 3% decrease in the average Ca/P molar ratio of the bone mineral. Finally, the determination of the concentration of vancomycin released into the blood stream indicated a negligible systemic load. Six months following implantation in the pigs, the quantified ratio of new bone indicated an improvement in osseointegration, with a two-fold bone ingrowth on the COLHA (47%) and COLHA+V (52%) compared to the control implants without a COLHA layer (27%). Therefore, it can be concluded that COLHA+V layers are able to significantly prevent the destruction of bone structure related to bacterial infection with a minimal systemic load and, simultaneously, enhance the rate of osseointegration.

16.
Diagnostics (Basel) ; 10(1)2020 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-31936486

RESUMEN

The α-defensins (AD) present in synovial fluid have been regarded as constituting the most accurate periprosthetic joint infection (PJI) biomarker. The methods most commonly used for estimating AD as a biomarker are the qualitative Synovasure® PJI tests, based on the technique of lateral flow, and quantitative enzyme-linked immunosorbent assay (ELISA). Here, we propose a novel test based on detecting α-defensins in synovial fluid by high-performance liquid chromatography (HPLC). Synovial fluid was collected from 157 patients diagnosed with PJI, infectious arthritis (IA), arthrosis, reactive arthritis, and rheumatoid arthritis. AD concentrations in the fluid were determined by HPLC, and these same samples were used for additional diagnostic analyses. The results were statistically processed to calculate cutoff concentrations for PJI and IA. HPLC testing showed a sensitivity of 94% and a specificity of 92% for diagnosis of PJI, and a sensitivity of 97% and a specificity of 87% for diagnosis of IA. Using HPLC, we detected in synovial fluid a combination of three α-defensins: human neutrophil peptides HNP1, HNP2, and HNP3. All measured AD concentration values shown in this work refer to the sum of these three individual concentrations. Our study shows that the HPLC method meets the conditions for measuring precise concentrations of the sum of AD and can be recommended as part of a diagnostic array for PJI and IA diagnostics. By this method, we have verified that higher levels of AD in synovial fluid can also be seen in rheumatoid illnesses, crystal arthropathies, and reactive arthritis.

17.
Folia Microbiol (Praha) ; 65(3): 475-482, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31654320

RESUMEN

Vancomycin is often used in orthopedic surgery as a local prophylaxis of bacterial infection. The aim of this work was to compare the release of vancomycin and its biologically inactive crystalline degradation products (CDP-1) during in vitro experiments from different types of local antibiotic delivery systems (bone grafts and bone cements). The concentrations of vancomycin and its crystalline degradation products were determined by high-performance liquid chromatography. Each experiment was performed in a phosphate buffer solution over 21 days. Morselized bone grafts, synthetic bone cements Palacos and Copal, and synthetic bone grafts were tested as local carriers of vancomycin. The highest concentration approximately 670 mg/L of vancomycin was released from synthetic bone grafts Actifuse. Even after 21 days, the concentration of vancomycin was still above the minimum inhibitory concentration (MIC). The maximum concentration of vancomycin released in two experiments with human bone grafts exceeded 600 mg/L during the first day and was still above MIC level 21 days later when the experiment was concluded. By comparing the synthetic bone cements Palacos and Copal, Copal had the average maximum concentration of only 32.4 mg/L and Palacos 35.7 mg/L. The concentration of vancomycin fell below the MIC for vancomycin-resistant Staphylococcus aureus (VRSA) on the seventh day with Palacos and the ninth day with Copal. This study showed the insufficient concentration of released vancomycin from synthetic bone cements at the end of the experiment. For improvement of local prophylaxis, it would be beneficial to increase the amount of vancomycin in bone cements.


Asunto(s)
Antibacterianos/análisis , Antibacterianos/metabolismo , Cementos para Huesos/análisis , Vancomicina/análisis , Vancomicina/metabolismo , Trasplante Óseo , Cromatografía Líquida de Alta Presión , Humanos , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Pruebas de Sensibilidad Microbiana
18.
PeerJ ; 7: e7695, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31579595

RESUMEN

A novel application of the liquid chromatography method combined with the triple quadrupole tandem mass spectrometry method was developed for the quantification of vitamin K1 and two forms of vitamin K2 (menaquinone-4, menaquinone-7) in human serum. Total chromatography time for each run was 9 min. Time required for the sample pretreatment procedures was approximately 4 h. The coefficients of variation (CVs) of intra-assay were 10.4%, 3.2 % and 2.3% for vitamin K1 in three levels of quality control samples; were 14.3%, 3.2% and 6.7% for menaquinone-4; and were 11.1%, 6.0% and 7.0% for menaquinone-7. The inter-assay CVs were 12.8%, 11.3% and 7.4% for vitamin K1; were 15.2%, 9.2% and 8.7% for menaquinone-4; and were 13.2%,11.1% and 7.2% for menaquinone-7. No interference was found between K1, menaquinone-4 and menaquinone-7, nor any deuterated internal standards. This method was then used to determine reference values for Caucasian populations of central European origin. Samples were measured from 191 healthy volunteers (51.2 ± 16.2 years (mean ± SD)) and the values concerning K1 were 0.044-1.357 ng/mL for women and 0.030-1.214 ng/mL for men. The values for menaquinone-4 and menaquinone-7 did not exhibit any differences between women and men, and were 0.050-1.598 and 0.074-0.759 ng/mL, respectively.

19.
Eur J Pharm Biopharm ; 140: 50-59, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31055065

RESUMEN

The aim of this study was to develop a biodegradable nanostructured electrospun layer based on collagen (COL), hydroxyapatite nanoparticles (HA), vancomycin hydrochloride (V), gentamicin sulphate (G) and their combination (VG) for the treatment of prosthetic joint infections and the prevention of infection during the joint replacement procedure. COL/HA layers containing different amounts of HA (0, 5 and 15 wt%) were tested for the in vitro release kinetics of antibiotics, antimicrobial activity against MRSA, gentamicin-resistant Staphylococcus epidermidis and Enterococcus faecalis isolates and cytocompatibility using SAOS-2 bone-like cells. The results revealed that the COL/HA layers released high concentrations of vancomycin and gentamicin for 21 days and performed effectively against the tested clinically-relevant bacterial isolates. The presence of HA in the collagen layers was found not to affect the release kinetics of the vancomycin from the layers loaded only with vancomycin or its combination with gentamicin. Conversely, the presence of HA slowed down the release of gentamicin from the COL/HA layers loaded with gentamicin and its combination with vancomycin. The combination of both antibiotics exerted a positive effect on the prolongation of the conversion of vancomycin into its degradation products. All the layers tested with different antibiotics exhibited potential antibacterial activity with respect to both the tested staphylococci isolates and enterococci. The complemental effect of vancomycin was determined against both gentamicin-resistant Staphylococcus epidermidis and Enterococcus faecalis in contrast to the application of gentamicin as a single agent. This combination was also found to be more effective against MRSA than is vancomycin as a single agent. Importantly, this combination of vancomycin and gentamicin in the COL/HA layers exhibited sufficient cytocompatibility to SAOS-2, which was independent of the HA content. Conversely, only gentamicin caused the death of SAOS-2 independently of HA content and only vancomycin stimulated SAOS-2 behaviour with an increased concentration of HA in the COL/HA layers. In conclusion, COL/HA layers with 15 wt% of HA impregnated with vancomycin or with a combination of vancomycin and gentamicin offer a promising treatment approach and the potential to prevent infection during the joint replacement procedures.


Asunto(s)
Antibacterianos/farmacología , Colágeno/química , Durapatita/química , Gentamicinas/farmacología , Vancomicina/farmacología , Antibacterianos/química , Cementos para Huesos/química , Línea Celular , Sinergismo Farmacológico , Enterococcus faecalis/efectos de los fármacos , Gentamicinas/química , Humanos , Cinética , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Pruebas de Sensibilidad Microbiana/métodos , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/prevención & control , Staphylococcus epidermidis/efectos de los fármacos , Vancomicina/química
20.
Eur J Pharm Sci ; 100: 219-229, 2017 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-28132822

RESUMEN

The aim of this study was to develop an osteo-inductive resorbable layer allowing the controlled elution of antibiotics to be used as a bone/implant bioactive interface particularly in the case of prosthetic joint infections, or as a preventative procedure with respect to primary joint replacement at a potentially infected site. An evaluation was performed of the vancomycin release kinetics, antimicrobial efficiency and cytocompatibility of collagen/hydroxyapatite layers containing vancomycin prepared employing different hydroxyapatite concentrations. Collagen layers with various levels of porosity and structure were prepared using three different methods: by means of the lyophilisation and electrospinning of dispersions with 0, 5 and 15wt% of hydroxyapatite and 10wt% of vancomycin, and by means of the electrospinning of dispersions with 0, 5 and 15wt% of hydroxyapatite followed by impregnation with 10wt% of vancomycin. The maximum concentration of the released active form of vancomycin characterised by means of HPLC was achieved via the vancomycin impregnation of the electrospun layers, whereas the lowest concentration was determined for those layers electrospun directly from a collagen solution containing vancomycin. Agar diffusion testing revealed that the electrospun impregnated layers exhibited the highest level of activity. It was determined that modification using hydroxyapatite exerts no strong effect on vancomycin evolution. All the tested samples exhibited sufficient cytocompatibility with no indication of cytotoxic effects using human osteoblastic cells in direct contact with the layers or in 24-hour infusions thereof. The results herein suggest that nano-structured collagen-hydroxyapatite layers impregnated with vancomycin following cross-linking provide suitable candidates for use as local drug delivery carriers.


Asunto(s)
Antibacterianos , Colágeno , Sistemas de Liberación de Medicamentos , Durapatita , Vancomicina , Antibacterianos/administración & dosificación , Antibacterianos/química , Línea Celular Tumoral , Colágeno/administración & dosificación , Colágeno/química , Durapatita/administración & dosificación , Durapatita/química , Femenino , Humanos , Masculino , Nanoestructuras/administración & dosificación , Nanoestructuras/química , Osteoblastos/efectos de los fármacos , Plasma/química , Staphylococcus aureus/efectos de los fármacos , Staphylococcus epidermidis/efectos de los fármacos , Vancomicina/administración & dosificación , Vancomicina/química
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda