Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Magn Reson Med ; 92(3): 900-915, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38650306

RESUMEN

PURPOSE: Sodium triple quantum (TQ) signal has been shown to be a valuable biomarker for cell viability. Despite its clinical potential, application of Sodium TQ signal is hindered by complex pulse sequences with long scan times. This study proposes a method to approximate the TQ signal using a single excitation pulse without phase cycling. METHODS: The proposed method is based on a single excitation pulse and a comparison of the free induction decay (FID) with the integral of the FID combined with a shifting reconstruction window. The TQ signal is calculated from this FID only. As a proof of concept, the method was also combined with a multi-echo UTE imaging sequence on a 9.4 T preclinical MRI scanner for the possibility of fast TQ MRI. RESULTS: The extracted Sodium TQ signals of single-pulse and spin echo FIDs were in close agreement with theory and TQ measurement by traditional three-pulse sequence (TQ time proportional phase increment [TQTPPI)]. For 2%, 4%, and 6% agar samples, the absolute deviations of the maximum TQ signals between SE and theoretical (time proportional phase increment TQTPPI) TQ signals were less than 1.2% (2.4%), and relative deviations were less than 4.6% (6.8%). The impact of multi-compartment systems and noise on the accuracy of the TQ signal was small for simulated data. The systematic error was <3.4% for a single quantum (SQ) SNR of 5 and at maximum <2.5% for a multi-compartment system. The method also showed the potential of fast in vivo SQ and TQ imaging. CONCLUSION: Simultaneous SQ and TQ MRI using only a single-pulse sequence and SQ time efficiency has been demonstrated. This may leverage the full potential of the Sodium TQ signal in clinical applications.


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Sodio , Imagen por Resonancia Magnética/métodos , Sodio/química , Procesamiento de Señales Asistido por Computador , Procesamiento de Imagen Asistido por Computador/métodos , Humanos , Relación Señal-Ruido , Animales
2.
NMR Biomed ; 37(5): e5106, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38263738

RESUMEN

PURPOSE: Both sodium T1 triple quantum (TQ) signal and T1 relaxation pathways have a unique sensitivity to the sodium molecular environment. In this study an inversion recovery time proportional phase increment (IRTQTPPI) pulse sequence was investigated for simultaneous and reliable quantification of sodium TQ signal and bi-exponential T1 relaxation times. METHODS: The IRTQTPPI sequence combines inversion recovery TQ filtering and time proportional phase increment. The reliable and reproducible results were achieved by the pulse sequence optimized in three ways: (1) optimization of the nonlinear fit for the determination of both T1-TQ signal and T1 relaxation times; (2) suppression of unwanted signals by assessment of four different phase cycles; (3) nonlinear sampling during evolution time for optimal scan time without any compromises in fit accuracy. The relaxation times T1 and T2 and the TQ signals from IRTQTPPI and TQTPPI were compared between 9.4 and 21.1 T. The motional environment of the sodium nuclei was evaluated by calculation of correlation times and nuclear quadrupole interaction strengths. RESULTS: Reliable measurements of the T1-TQ signals and T1 bi-exponential relaxation times were demonstrated. The fit parameters for all four phase cycles were in good agreement with one another, with a negligible influence of unwanted signals. The agar samples yielded normalized T1-TQ signals from 3% to 16% relative to single quantum (SQ) signals at magnetic fields of both 9.4 and 21.1 T. In comparison, the normalized T2-TQ signal was in the range 15%-35%. The TQ/SQ signal ratio was decreased at 21.1 T as compared with 9.4 T for both T1 and T2 relaxation pathways. The bi-exponential T1 relaxation time separation ranged from 15 to 18 ms at 9.4 T and 15 to 21 ms at 21.1 T. The T2 relaxation time separation was larger, ranging from 28 to 35 ms at 9.4 T and 37 to 40 ms at 21.1 T. CONCLUSION: The IRTQTPPI sequence, while providing a less intensive TQ signal than TQTPPI, allows a simultaneous and reliable quantification of both the T1-TQ signal and T1 relaxation times. The unique sensitivities of the T1 and T2 relaxation pathways to different types of molecular motion provide a deeper understanding of the sodium MR environment.


Asunto(s)
Imagen por Resonancia Magnética , Sodio , Imagen por Resonancia Magnética/métodos
3.
NMR Biomed ; 33(10): e4367, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32656956

RESUMEN

The aim of this study was to investigate possible sodium triple-quantum (TQ) signal dependence on pH variation and protein unfolding which may happen in vivo. The model system, composed of bovine serum albumin (BSA), was investigated over a wide pH range of 0.70 to 13.05 and during urea-induced unfolding. In both experimental series, the sodium and BSA concentration were kept constant so that TQ signal changes solely arose from an environmental change. The experiments were performed using unique potential to detect weak TQ signals by implementing a TQ time proportional phase increment pulse sequence. At a pH of 0.70, in which case the effect of the negatively charged groups was minimized, the minimum TQ percentage relative to single-quantum of 1.34% ± 0.05% was found. An increase of the pH up to 13.05 resulted in an increase of the sodium TQ signal by 225%. Urea-induced unfolding of BSA, without changes in pH, led to a smaller increase in the sodium TQ signal of up to 40%. The state of BSA unfolding was verified by fluorescence microscopy. Results of both experiments were well fitted by sigmoid functions. Both TQ signal increases were in agreement with an increase of the availability of negatively charged groups. The results point to vital contributions of the biochemical environment to the TQ MR signals. The sodium TQ signal in vivo could be a valuable biomarker of cell viability, and therefore possible effects of pH and protein unfolding need to be considered for a proper interpretation of changes in sodium TQ signals.


Asunto(s)
Espectroscopía de Resonancia Magnética , Procesamiento de Señales Asistido por Computador , Sodio/química , Animales , Bovinos , Fluorescencia , Concentración de Iones de Hidrógeno , Fantasmas de Imagen , Conformación Proteica , Desplegamiento Proteico/efectos de los fármacos , Albúmina Sérica Bovina/química , Albúmina Sérica Bovina/metabolismo , Electricidad Estática , Urea/farmacología
4.
J Magn Reson Imaging ; 51(2): 355-376, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31102340

RESUMEN

1 H imaging is concerned with contrast generation among anatomically distinct soft tissues. X-nuclei imaging, on the other hand, aims to reveal the underlying changes in the physiological processes on a cellular level. Advanced clinical MR hardware systems improved 1 H image quality and simultaneously enabled X-nuclei imaging. Adaptation of 1 H methods and optimization of both sequence design and postprocessing protocols launched X-nuclei imaging past feasibility studies and into clinical studies. This review outlines the current state of X-nuclei MRI, with the focus on 23 Na, 35 Cl, 39 K, and 17 O. Currently, various aspects of technical challenges limit the possibilities of clinical X-nuclei MRI applications. To address these challenges, quintessential physical and technical concepts behind different applications are presented, and the advantages and drawbacks are delineated. The working process for methods such as quantification and multiquantum imaging is shown step-by-step. Clinical examples are provided to underline the potential value of X-nuclei imaging in multifaceted areas of application. In conclusion, the scope of the latest technical advance is outlined, and suggestions to overcome the most fundamental hurdles on the way into clinical routine by leveraging the full potential of X-nuclei imaging are presented. Level of Evidence: 1 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2020;51:355-376.


Asunto(s)
Imagen por Resonancia Magnética , Sodio , Iones
5.
J Magn Reson Imaging ; 50(2): 435-444, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30681221

RESUMEN

BACKGROUND: Triple-quantum (TQ) filtered sequences have become more popular in sodium MR due to the increased usage of scanners with field strengths exceeding 3T. Disagreement as to whether TQ signal can provide separation of intra- and extracellular compartments persists. PURPOSE: To provide insight into TQ signal behavior on a cellular level. STUDY TYPE: Prospective. PHANTOM/SPECIMEN: Cell-phantoms in the form of liposomes, encapsulated 0 mM, 145 mM, 154 mM Na+ in a double-lipid membrane similar to cells. Poly(lactic-co-glycolic acid) nanoparticles encapsulated 154 mM Na+ within a single-layer membrane structure. Two microcavity chips with each 6 × 106 human HEP G2 liver cells were measured in an MR-compatible bioreactor. FIELD STRENGTH/SEQUENCE: Spectroscopic TQ sequence with time proportional phase-increments at 9.4T. ASSESSMENT: The TQ signal of viable, dead cells, and cell-phantoms was assessed by a fit in the time domain and by the amplitude in the frequency domain. STATISTICAL TESTS: The noise variance (σ) was evaluated to express the deviation of the measured TQ signal amplitude from noise. RESULTS: TQ signal >20σ was found for liposomes encapsulating sodium ions. Liposomal encapsulation of 0 mM Na+ and 154 mM Na+ encapsulation in the nanoparticles resulted in <2σ TQ signal. Cells under normal perfusion resulted in >9σ TQ signal. Compared with TQ signal under normal perfusion, a 56% lower TQ signal of was observed (25σ) during perfusion stop. TQ signal returned to 92% of the initial signal after reperfusion. DATA CONCLUSION: Our measurements indicate that TQ signal in liposomes was observed due to the trapping of ions within the double-lipid membrane rather than from the intraliposomal space. Transfer to the cell results suggests that TQ signal was observed from motion restriction equivalent to trapping. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2019;50:435-444.


Asunto(s)
Liposomas/metabolismo , Hígado/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Nanopartículas/metabolismo , Procesamiento de Señales Asistido por Computador , Isótopos de Sodio/metabolismo , Supervivencia Celular , Células Cultivadas , Humanos , Técnicas In Vitro , Estudios Prospectivos
6.
Sci Rep ; 10(1): 11118, 2020 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-32632120

RESUMEN

CEST-MRI of the rNOE signal has been demonstrated in vitro to be closely linked to the protein conformational state. As the detectability of denaturation and aggregation processes on a physiologically relevant scale in living organisms has yet to be verified, the aim of this study was to perform heat-shock experiments with living cells to monitor the cellular heat-shock response of the rNOE CEST signal. Cancer cells (HepG2) were dynamically investigated after a mild, non-lethal heat-shock of 42 °C for 20 min using an MR-compatible bioreactor system at 9.4 T. Reliable and fast high-resolution CEST imaging was realized by a relaxation-compensated 2-point contrast metric. After the heat-shock, a substantial decrease of the rNOE CEST signal by 8.0 ± 0.4% followed by a steady signal recovery within a time of 99.1 ± 1.3 min was observed in two independent trials. This continuous signal recovery is in coherence with chaperone-induced refolding of heat-shock induced protein aggregates. We demonstrated that protein denaturation processes influence the CEST-MRI signal on a physiologically relevant scale. Thus, the protein folding state is, along with concentration changes, a relevant physiological parameter for the interpretation of CEST signal changes in diseases that are associated with pathological changes in protein expression, like cancer and neurodegenerative diseases.


Asunto(s)
Carcinoma Hepatocelular/patología , Proteínas de Choque Térmico/metabolismo , Respuesta al Choque Térmico , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Imagen Molecular/métodos , Monitoreo Fisiológico , Algoritmos , Carcinoma Hepatocelular/metabolismo , Proteínas de Choque Térmico/química , Células Hep G2 , Humanos , Interpretación de Imagen Asistida por Computador , Neoplasias Hepáticas/metabolismo , Agregado de Proteínas , Desnaturalización Proteica
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda