Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
Clin Oral Investig ; 28(10): 571, 2024 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-39365479

RESUMEN

OBJECTIVES: Single midline implants in the edentulous mandible can be used to support existing complete dentures to improve patients' satisfaction and masticatory efficiency. The impact on patients' dietary habits and the influence of the loading protocol of the implants was the subject of this study. MATERIALS AND METHODS: In this prospective randomized clinical trial, edentulous patients with existing complete dentures in both jaws were treated with a single midline implant in the mandible. In group A, the implants were loaded immediately, in group B the loading was delayed after three months. Patients were asked to report on their nutritional intake before implant placement and 12, 24 and 60 months after loading using a standardized two-part questionnaire. RESULTS: Nutritional intake regarding the frequency of consumption of the requested food items did not change significantly during the 60-months study period, regardless of the loading protocol. In contrast, the second part of the questionnaire revealed that after 60 months, there was a significant decrease in avoidance of food, that had a coarse and hard texture in both groups. This significant decrease was observable in the group A in the first 12 and 24 months and in the group B after 60 months. CONCLUSION: A change in the patients' dietary habits due to the insertion of a single midline implant in the mandible to support the existing complete denture cannot be observed, independently to the loading protocol. CLINICAL RELEVANCE: Improving the chewing efficiency by single midline implants in the edentulous mandible does not lead to a change in dietary habits.


Asunto(s)
Prótesis Dental de Soporte Implantado , Conducta Alimentaria , Carga Inmediata del Implante Dental , Arcada Edéntula , Mandíbula , Humanos , Femenino , Masculino , Estudios Prospectivos , Encuestas y Cuestionarios , Anciano , Mandíbula/cirugía , Arcada Edéntula/rehabilitación , Masticación/fisiología , Persona de Mediana Edad , Resultado del Tratamiento , Satisfacción del Paciente , Implantes Dentales de Diente Único
2.
Clin Oral Implants Res ; 34(2): 105-115, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36444693

RESUMEN

OBJECTIVE: To investigate the fracture strength and potential phase transformation of an injection-molded two-piece zirconia implant restored with a zirconia abutment after loading and/or aging. METHODS: Thirty-two two-piece zirconia implants (4.0 mm diameter) restored with zirconia abutments were embedded according to ISO 14801 and divided into four groups (n = 8/group): Three groups were either exclusively hydrothermally treated (group HT; 85°C), dynamically loaded (group DL; 107 cycles; 98 N), or subjected to both treatments simultaneously (group DL/HT). One group remained untreated (group 0). A sample from each group was cross-sectioned and examined by scanning electron microscopy for possible crystal phase transformation. The remaining samples were then loaded to fracture in a static loading test. A one-way ANOVA was used for statistical analyses. RESULTS: During dynamic loading, three implants of group DL and six implants of group DL/HT fractured at a load of 98 N. The fracture strength of group DL/HT (108 ± 141 Ncm) was significantly reduced compared to the other groups (group 0: 342 ± 36 Ncm; HT: 363 ± 49 Ncm; DL: 264 ± 198 Ncm) (p < .05). Fractures from group 0 and HT occurred at both implant and abutment level, whereas implants from group DL and DL/HT fractured only at implant level. A shallow monoclinic transformation zone of approximately 2 µm was observed following hydrothermal treatment. CONCLUSIONS: Within the limitations of this study, it can be concluded that dynamic loading and the combination of loading and aging reduced the fracture strength of the implant abutment combination. Hydrothermal treatment caused a shallow transformation zone which had no influence on the fracture strength.


Asunto(s)
Implantes Dentales , Resistencia Flexional , Diseño de Implante Dental-Pilar , Ensayo de Materiales , Titanio/química , Circonio/química , Análisis del Estrés Dental , Pilares Dentales , Fracaso de la Restauración Dental
3.
J Evid Based Dent Pract ; 23(1S): 101794, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36707170

RESUMEN

BACKGROUND: When dental patients seek care, treatments are not always successful,that is patients' oral health problems are not always eliminated or substantially reduced. Identifying these patients (treatment non-responders) is essential for clinical decision-making. Group-based trajectory modeling (GBTM) is rarely used in dentistry, but a promising statistical technique to identify non-responders in particular and clinical distinct patient groups in general in longitudinal data sets. AIM: Using group-based trajectory modeling, this study aimed to demonstrate how to identify oral health-related quality of life (OHRQoL) treatment response patterns by the example of patients with a shortened dental arch (SDA). METHODS: This paper is a secondary data analysis of a randomized controlled clinical trial. In this trial SDA patients received partial removable dental prostheses replacing missing teeth up to the first molars (N = 79) either or the dental arch ended with the second premolar that was present or replaced by a cantilever fixed dental prosthesis (N = 71). Up to ten follow-up examinations (1-2, 6, 12, 24, 36, 48, 60, 96, 120, and 180 months post-treatment) continued for 15 years. The outcome OHRQoL was assessed with the 49-item Oral Health Impact Profile (OHIP). Exploratory GBTM was performed to identify treatment response patterns. RESULTS: Two response patterns could be identified - "responders" and "non-responders." Responders' OHRQoL improved substantially and stayed primarily stable over the 15 years. Non-responders' OHRQoL did not improve considerably over time or worsened. While the SDA treatments were not related to the 2 response patterns, higher levels of functional, pain-related, psychological impairment in particular, and severely impaired OHRQoL in general predicted a non-responding OHRQoL pattern after treatment. Supplementary, a 3 pattern approach has been evaluated. CONCLUSIONS: Clustering patients according to certain longitudinal characteristics after treatment is generally important, but specifically identifying treatment in non-responders is central. With the increasing availability of OHRQoL data in clinical research and regular patient care, GBTM has become a powerful tool to investigate which dental treatment works for which patients.


Asunto(s)
Dentadura Parcial Removible , Calidad de Vida , Humanos , Dentadura Parcial Removible/psicología , Arco Dental , Salud Bucal , Diente Molar
4.
J Prosthet Dent ; 128(6): 1303-1309, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33902891

RESUMEN

STATEMENT OF PROBLEM: The accuracy of intraoral scanners is a prerequisite for the fabrication of dental restorations in computer-aided design and computer-aided manufacturing (CAD-CAM) dentistry. While the precision of intraoral scanners has been investigated in vitro, clinical data on the accuracy of intraoral scanning (IOS) are limited. PURPOSE: The purpose of this clinical study was to determine the accuracy of intraoral scanning with different devices compared with extraoral scanning. MATERIAL AND METHODS: An experimental appliance was fabricated for 11 participants and then scanned intraorally and extraorally with 3 different intraoral scanners and a reference scanner. Intraoral and extraoral scans were subdivided into complete-arch and short-span scans and compared with the reference scan to assess trueness. Repeated scans in each group were assessed for precision. RESULTS: Precision and trueness were higher for extraoral scans compared with intraoral scans, except for complete-arch scans with 1 intraoral scanner. The median precision of short-span scans was higher (extraoral: 22 to 29 µm, intraoral: 23 to 43 µm) compared with complete-arch scans (extraoral: 81 to 165 µm, intraoral: 80 to 198 µm). The median trueness of short-span scans (extraoral: 28 to 40 µm, intraoral: 38 to 47 µm) was higher than that of complete-arch scans (extraoral: 118 to 581 µm, intraoral: 147 to 433 µm) for intraoral and extraoral scanning. CONCLUSIONS: Intraoral conditions negatively influenced the accuracy of the scanning devices, which was also reduced for the complete-arch scans.


Asunto(s)
Técnica de Impresión Dental , Modelos Dentales , Humanos , Imagenología Tridimensional , Diseño Asistido por Computadora , Arco Dental
5.
J Prosthet Dent ; 2022 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-36586814

RESUMEN

STATEMENT OF PROBLEM: Making conventional facial impressions can be uncomfortable for the patient and complicated for the prosthodontist. Using facial scanners to digitize faces is an alternative approach. However, the initial costs of the equipment have prevented their widespread use in dental practice, and the accuracy of ear scanning is unclear. PURPOSE: The purpose of this in vitro study was to investigate the accuracy of a widely used intraoral scanner for digitizing an ear model. MATERIAL AND METHODS: For reference, a silicone model of an ear was scanned with an industrial scanner. Then, the model was scanned 5 times with an intraoral scanner. Five conventional impressions of the model were made with a hydrocolloid impression material and poured with dental stone. The stone casts were then digitized with a desktop scanner. The data sets acquired with the 3 approaches were analyzed by using a 3-dimensional (3D) evaluation software program. Trueness and precision values were calculated for each approach. Linear mixed models with random intercepts were fitted to each sample to evaluate the effects of the impression method on mean deviations (α=.05). RESULTS: Mean ±standard deviation trueness and precision values were 0.097 ±0.012 mm and 0.033 ±0.015 mm, respectively, for the digital scan, and 0.092 ±0.022 mm and 0.081 ±0.024 mm for the conventional impression, showing a significantly lower deviation in precision for the digital approach (P<.001). CONCLUSIONS: The feasibility of digitizing an ear efficiently by using the investigated intraoral scanner was demonstrated, and similar trueness and significantly better precision values were achieved than when using conventional impressions. These promising results suggest the need for clinical investigations.

6.
Clin Oral Implants Res ; 32 Suppl 21: 254-288, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34642991

RESUMEN

OBJECTIVE: To assess the survival, failure, and complication rates of veneered and monolithic all-ceramic implant-supported single crowns (SCs). METHODS: Literature search was conducted in Medline (PubMed), Embase, and Cochrane Central Register of Controlled Trials until September 2020 for randomized, prospective, and retrospective clinical trials with follow-up time of at least 1 year, evaluating the outcome of veneered and/or monolithic all-ceramic SCs supported by titanium dental implants. Survival and complication rates were analyzed using robust Poisson's regression models. RESULTS: Forty-nine RCTs and prospective studies reporting on 57 material cohorts were included. Meta-analysis of the included studies indicated an estimated 3-year survival rate of veneered-reinforced glass-ceramic implant-supported SCs of 97.6% (95% CI: 87.0%-99.6%). The estimated 3-year survival rates were 97.0% (95% CI: 94.0%-98.5%) for monolithic-reinforced glass-ceramic implant SCs, 96.9% (95% CI: 93.4%-98.6%) for veneered densely sintered alumina SCs, 96.3% (95% CI: 93.9%-97.7%) for veneered zirconia SCs, 96.1% (95% CI: 93.4%-97.8%) for monolithic zirconia SCs and only 36.3% (95% CI: 0.04%-87.7%) for resin-matrix-ceramic (RMC) SCs. With the exception of RMC SCs (p < 0.0001), the differences in survival rates between the materials did not reach statistical significance. Veneered SCs showed significantly (p = 0.017) higher annual ceramic chipping rates (1.65%) compared with monolithic SCs (0.39%). The location of the SCs, anterior vs. posterior, did not influence survival and chipping rates. CONCLUSIONS: With the exception of RMC SCs, veneered and monolithic implant-supported ceramic SCs showed favorable short-term survival and complication rates. Significantly higher rates for ceramic chipping, however, were reported for veneered compared with monolithic ceramic SCs.


Asunto(s)
Implantes Dentales , Fracaso de la Restauración Dental , Cerámica , Coronas , Prótesis Dental de Soporte Implantado/efectos adversos , Estudios Prospectivos , Estudios Retrospectivos
7.
Clin Oral Implants Res ; 32(11): 1288-1298, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34352139

RESUMEN

OBJECTIVE: To evaluate the influence of artificial aging on the transformation propagation and fracture resistance of zirconia implants. METHODS: One-piece (with integrated implant abutment, 1P; regular diameter [4.1mm]; n = 16) and two-piece (with separate implant abutment, 2P; wide diameter [5 mm]; n = 16) zirconia implants were embedded according to ISO 14801. A two-piece titanium-zirconium implant (Ti-Zr; 4.1 mm diameter) served as a control (n = 16). One subgroup (n = 8) of each system was simultaneously dynamically loaded (107 cycles; 98N) and hydrothermally aged (85°C, 58 days), while the other subgroup (n = 8) remained untreated. Finally, specimens were statically loaded to fracture. Potential crystal phase transformation was examined at cross sections using scanning electron microscopy (SEM). A multivariate linear regression model was applied for statistical analyses. RESULTS: The fracture resistance of 1P (1,117 [SD = 38] N; loaded/aged: 1,009 [60] N), 2P (850 [36] N; loaded/aged: 799 [84] N), and Ti-Zr implants (1,338 [205] N; loaded/aged: 1,319 [247] N) was not affected significantly by loading/aging (p = .171). However, when comparing the systems, they revealed significant differences independent of loading/aging (p ≤ .001). Regarding the crystal structure, a transformation zone was observed in SEM images of 1P only after aging, while 2P showed a transformation zone even before aging. After hydrothermal treatment, an increase of this monoclinic layer was observed in both systems. CONCLUSIONS: The Ti-Zr control implant showed higher fracture resistance compared to both zirconia implants. Loading/aging had no significant impact on the fracture resistance of both zirconia implants. The wide-body 2P zirconia implant was weaker than the regular body 1P implant.


Asunto(s)
Implantes Dentales , Circonio , Pilares Dentales , Diseño de Implante Dental-Pilar , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Ensayo de Materiales , Titanio
8.
Clin Oral Implants Res ; 32(2): 212-221, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33258136

RESUMEN

OBJECTIVES: This multicenter randomized controlled clinical trial was conducted to investigate whether the loading protocol of single dental implants placed in the midline of edentulous mandibles will influence the implant survival or prosthetic maintenance. MATERIALS AND METHODS: In total, 158 patients were randomly assigned either to the immediate loading group (n = 81) or to the delayed loading group (n = 77). All implants were loaded with an overdenture retained by a ball attachment. RESULTS: After 5 years, 102 patients attended the follow-up investigation. Immediately loaded single implants in the midline of the edentulous mandible revealed a statistically significant lower survival rate than implants loaded conventionally over an observation period of 5 years. In the immediate loading group, 9 implants failed within the first three months of implant loading. No further implant loss was recorded for this group. Two implants failed in the delayed loading group, whereas one implant had to be removed during second-stage surgery and the second five years after implant loading. Non-inferiority of the survival rate of the midline implant of the immediate loading group, compared with the delayed loading group, could not be shown (p = .79, CI immediate loading: 74.9%; 100.0%, CI delayed loading: 73.0%; 100.0%). The observed difference in implant survival between the two treatment groups over time was statistically significant. CONCLUSIONS: The results of the present study indicate that immediate loading of a single mandibular implant in the edentulous mandible should be considered only in exceptional cases.


Asunto(s)
Implantes Dentales , Carga Inmediata del Implante Dental , Arcada Edéntula , Implantación Dental Endoósea , Prótesis Dental de Soporte Implantado , Fracaso de la Restauración Dental , Prótesis de Recubrimiento , Humanos , Arcada Edéntula/cirugía , Mandíbula/cirugía , Resultado del Tratamiento
9.
J Oral Rehabil ; 48(6): 738-744, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33713361

RESUMEN

BACKGROUND: Few long-term studies on treatments in the shortened dental arch (SDA) are available. OBJECTIVE: The objective of this trial was to analyse the long-term success of two different treatment concepts. METHODS: Patients over 35 years of age with missing molars in one jaw and at least the canine and one premolar present on both sides were eligible. In the partial removable dental prosthesis (PRDP) group (N = 81), molars and missing second premolars were replaced by a precision attachment retained prosthesis. In the SDA group (N = 71), the dental arch ended with the second premolar that had to be present or replaced by a cantilever fixed dental prosthesis. Follow-up examinations were carried out over 15 years. RESULTS: A comprehensive outcome variable comprised four failure categories for which Kaplan-Meier survival (success) analyses were conducted. Half of the patients exhibited a continuous preservation of the per protocol prosthetic status that remained totally unaffected by complications for more than 10 years. The event-free success rates for moderate or worse failure implied a loss of the per protocol prosthetic status. The respective survival rates fell below 50% at 14.2 years in the PRDP group and 14.3 years in the SDA group. In none of the analyses, a significant group difference was found. CONCLUSIONS: In patients with an SDA condition, changes in the prosthetic status have to be expected. The affected proportion increases almost linearly from shortly after treatment and comprises the majority after 15 years. The influence of the examined treatments on success appears to be low.


Asunto(s)
Dentadura Parcial Removible , Arcada Parcialmente Edéntula , Pérdida de Diente , Diente Premolar , Arco Dental , Humanos
10.
J Evid Based Dent Pract ; 21(4): 101622, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34922713

RESUMEN

BACKGROUND: A shortened dental arch (SDA) is an established treatment concept for patients with missing molars. However, little is known regarding long-term course of oral health-related quality of life (OHRQoL) in patients with SDA and the benefits from replacement of missing molars. OBJECTIVE: Purpose of this multi-center randomized clinical trial was to assess OHRQoL over a period of 15 years in patients with molar replacement by a removable partial denture (RPD) compared to patients with a restored SDA without molar replacement. METHODS: Patients at least 35 years of age with all molars missing in 1 jaw and at least the canine and one premolar present on each side were included. Patients received either a precision attachment-retained, RPD for replacement of missing molars (n = 79), or the dental arch ended with the second premolar (SDA) that had to be present or replaced by a cantilever fixed dental prosthesis (n = 71). Follow-up examinations continued for 15 years. OHRQoL was assessed with the 49-item Oral Health Impact Profile (OHIP). OHIP summary and dimension scores were longitudinally modeled in the statistical analyses to assess course of OHRQoL over time applying an intention-to-treat approach. In addition, scores for the OHRQoL dimensions Oral Function, Orofacial Pain, Orofacial Appearance, and Psychosocial Impact were analyzed. RESULTS: After an initial improvement in OHRQoL indicated by a mean decrease of 20.0 OHIP points with an effect size of 0.61 in the entire study population, OHRQoL stayed relatively constant over the entire follow-up period. Assuming a constant time and treatment effects over the study period, OHRQoL did not differ statistically significant between the 2 treatments (0.4 OHIP points; 95%-CI: 7.1 - 6.2). OHRQoL after treatment did not change notably over 15 years and was statistically nonsignificant as well (P = .872). Similar findings were observed in all 4 OHRQoL dimensions. CONCLUSIONS: In patients, missing all molars in one jaw OHRQoL improved providing RPD or restoring SDA to a clinically relevant degree. Treatment-related improvement remained mostly stable over a period of at least 15 years. Therefore, patients can be informed that both treatment concepts are equivalent concerning long-term OHRQoL. Accordingly, patients' preferences regarding treatment options should be granted priority in treatment decision making with the SDA treatment option being the default.


Asunto(s)
Dentadura Parcial Removible , Calidad de Vida , Arco Dental , Humanos , Salud Bucal , Encuestas y Cuestionarios
11.
Anal Chem ; 92(21): 14432-14443, 2020 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-32970419

RESUMEN

Degradation of the implant surface and particle release/formation as an inflammation catalyst mechanism is an emerging concept in dental medicine that may help explain the pathogenesis of peri-implantitis. The aim of the present study was a synchrotron-based characterization of micro- and nanosized implant-related particles in inflamed human tissues around titanium and ceramic dental implants that exhibited signs of peri-implantitis. Size, distribution, and chemical speciation of the exogenous micro- and nanosized particle content were evaluated using synchrotron µ-X-ray fluorescence spectroscopy (XRF), nano-XRF, and µ-X-ray absorption near-edge structure (XANES). Titanium particles, with variable speciation, were detected in all tissue sections associated with titanium implants. Ceramic particles were found in five out of eight tissue samples associated with ceramic implants. Particles ranged in size from micro- to nanoscale. The local density of both titanium and ceramic particles was calculated to be as high as ∼40 million particles/mm3. µ-XANES identified titanium in predominantly two different chemistries, including metallic and titanium dioxide (TiO2). The findings highlight the propensity for particle accumulation in the inflamed tissues around dental implants and will help in guiding toxicological studies to determine the biological significance of such exposures.


Asunto(s)
Cerámica/efectos adversos , Implantes Dentales/efectos adversos , Microesferas , Nanopartículas , Periimplantitis/inducido químicamente , Periimplantitis/metabolismo , Titanio/efectos adversos , Cerámica/química , Cerámica/metabolismo , Humanos , Tamaño de la Partícula , Titanio/química , Titanio/metabolismo
12.
Clin Oral Implants Res ; 31(6): 575-583, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32105363

RESUMEN

OBJECTIVES: To present a workflow of virtual implant planning and guided implant surgery with magnetic resonance imaging (MRI) and virtual dental models without the use of ionizing radiation. METHODS: Five patients scheduled for implant placement underwent an MR examination at three Tesla using individualized 2D and 3D turbo spin-echo (TSE) sequences and dedicated head coils. The MRI data and virtual dental models derived from either optical model scans or intraoral scans were imported to a virtual implant planning software (coDiagnostiX, Dental Wings, Montreal, Canada). Virtual prosthetic planning and implant planning were performed regarding the hard and soft tissue anatomy. A drill guide was designed on the virtual dental model using computer-aided design (CAD) and manufactured in-house, using a 3D printer (Eden 260V, Stratasys, Eden Prairie, MN, USA). RESULTS: The MRI displayed all relevant anatomical structures for dental implant planning such as cortical and cancellous bone, floor of the nasal and maxillary sinus, inferior alveolar nerve and neighboring teeth. The manual alignment of virtual dental models with the MRI was possible using anatomical landmarks. Dental implant planning, CAD/CAM of a drill guide and fully guided implant placement were successfully performed. CONCLUSIONS: Guided implant surgery is feasible with MRI without ionizing radiation. Further studies will have to be conducted to study the accuracy of the presented protocol and compare it to the current workflow of guided surgery using CBCT.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Animales , Diseño Asistido por Computadora , Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Planificación de Atención al Paciente
13.
Clin Oral Implants Res ; 31(5): 452-462, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31981374

RESUMEN

AIM: To evaluate the clinical and radiological outcomes of one-piece zirconia implants restored with single crowns (SCs) or fixed dental prostheses (FDPs) over an observation period of 5 years in function. MATERIALS AND METHODS: In a prospective cohort investigation with two investigational centers, one-piece zirconia implants were placed in anterior and posterior sites. After a healing period of at least 2 months in the mandible and 4 months in the maxilla with immediate provisional reconstructions, the final all-ceramic SCs or three-unit FDPs were cemented. Patients were followed for 5 years. Clinical parameters and radiological measurements of the implants and the neighboring teeth were assessed. For the statistical analysis, linear mixed models were applied. RESULTS: A total of 71 implants were placed in 60 patients. Sixty-three implants in 53 patients could be evaluated at the 5-year follow-up. Six patients with a total of seven implants were counted as dropouts. One implant did not achieve adequate osseointegration and had to be removed 5 weeks after implantation. The 5-year survival rate was calculated as 98.4% (95% CI 91.6, 99.9). The mean overall marginal bone loss from implant placement to the 5-year follow-up was 0.7 ± 0.6 mm. After an initial mean marginal loss before loading the implants (0.7 mm), no further statistically significant change in marginal bone level (p = .458) could be observed. CONCLUSION: The investigated one-piece zirconia implant showed a high survival rate, very stable marginal bone, and mucosal margin levels after 5 years in function. Therefore, it can be considered safe and reliable for the reconstruction of implant-supported SCs or FDPs over a mid-term period.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Coronas , Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Dentadura Parcial Fija , Humanos , Estudios Prospectivos , Circonio
14.
Clin Oral Implants Res ; 30(5): 466-475, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30972828

RESUMEN

OBJECTIVES: To assess survival/success rates and patient-reported outcome of zirconia-based posterior single crowns (SCs) supported by zirconia implants in a prospective two-center study after five years of observation. MATERIAL AND METHODS: Forty-five patients were restored with 45 zirconia implant-supported posterior SCs composed of zirconia frameworks hand-layered with a leucite-reinforced feldspathic ceramic. Survival rates of SCs were assessed and technical success was evaluated according to modified United States Public Health Care (USPHS) criteria. Furthermore, patient-reported outcome measures (PROMs) were assessed by applying visual analog scales (VAS). Wilcoxon matched-pairs signed-rank test, mixed-effects ordered logistic regression, and linear mixed models were used to evaluate time effects on response variables. RESULTS: Forty patients were available after a mean observation period of 61.0 ± 1.4 months. One SC had to be replaced, resulting in a Kaplan-Meier (KM) survival estimate for the SCs of 97.5 ± 2.47%. Since nine reconstructions showed at least in one category a major deviation from the ideal (five major chippings, four with increased occlusal roughness, one significant crevice, and one pronounced over-contouring), the KM success estimate was 79.3 ± 5.8%. Incidence of chipping (n = 19) and occlusal roughness (n = 35) was frequent (p < 0.001). All PROMs at prosthetic delivery except for speech (p = 0.139) showed significantly improved VAS scores (81%-94%; p < 0.001) compared to pre-treatment evaluations. Thereafter, no decrease in satisfaction could be observed until the 5-year follow-up (93%-97%). CONCLUSION: Veneered zirconia-based SCs supported by zirconia implants showed high survival rates and highly satisfied patients' needs. However, significant incidence of technical complications is compromising the clinical long-term outcome for this indication.


Asunto(s)
Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Cerámica , Coronas , Fracaso de la Restauración Dental , Humanos , Estudios Prospectivos , Circonio
15.
J Clin Periodontol ; 45(1): 114-124, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28902420

RESUMEN

AIM: This 3-year report of a prospective long-term cohort investigation aimed to evaluate the clinical and radiographic outcomes of a one-piece zirconia oral implant for single-tooth replacement. MATERIALS AND METHODS: Sixty-five patients received a 1-stage implant surgery with immediate temporization. Standardized radiographs were taken at implant insertion, after 1 year, and after 3 years to monitor peri-implant bone levels. A univariate analysis of the association of different baseline parameters on marginal bone loss from implant insertion to 36 months was performed. Soft-tissue parameters were evaluated at prosthesis insertion, after 6 months, after 1 year, and at the 3-year follow-up. RESULTS: After 3 years, six posterior site implants were lost, giving a cumulative survival rate of 90.8%. The mean marginal bone loss was 1.45 mm; 35% of the implants lost at least 2 mm bone, and 22% more than 3 mm. The univariate analysis did not identify any parameter associated with marginal bone loss. Probing depth, clinical attachment level, and bleeding index increased over 3 years, and plaque index decreased. CONCLUSIONS: The low survival rate of the presented ceramic implant and especially the high frequency of advanced bone loss are noticeable but remain unexplained.


Asunto(s)
Implantes Dentales de Diente Único , Materiales Dentales , Diseño de Prótesis Dental , Circonio , Adolescente , Adulto , Anciano , Pérdida de Hueso Alveolar/epidemiología , Estudios de Cohortes , Fracaso de la Restauración Dental , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
16.
Clin Oral Implants Res ; 29(1): 91-99, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28940708

RESUMEN

OBJECTIVE: To evaluate the clinical and patient-reported outcome of all-ceramic zirconia implant supported fixed dental prostheses (FDPs) 5 years after implant installation. MATERIALS AND METHODS: Thirteen patients were treated with two terminally placed one-piece zirconia implants for a three-unit FDP each. The FDPs consisted of a CAD/CAM-fabricated zirconia framework over-pressed with a fluor-apatite veneering ceramic and were adhesively cemented. Survival and success were assessed by applying modified US Public Health Service (USPHS) criteria and preparation of Kaplan-Meier (KM) plots. Alpha and Bravo ratings were accepted for success (among others including small area veneer chippings and occlusal roughness), whereas Charlie ratings allowing for intra-oral correction (e.g., polishing) were accepted for survival. Furthermore, patient-reported outcome measures (PROMs) were analyzed with the help of visual analogue scales (VAS). Wilcoxon matched-pairs signed-rank test (USPHS criteria) and linear mixed models (PROMs) were used to evaluate time effects on response variables. RESULTS: All patients were available 61.8 ± 1.1 months after implant installation (53.6 ± 3.1 months after final prosthesis insertion). FDP survival was 100%. Significant incidence of veneer chipping (p = .0096) and occlusal roughness (p = .0019) was observed. Charlie rated extent of both phenomena resulted in a KM success estimate of 38.5% (95% CI: 14.1%-62.8%; seven FDPs with obvious roughness, three of them with extended veneer chipping). Compared with the pre-treatment assessments (30%-81% of satisfaction), all surveys at prosthetic delivery showed significantly improved VAS scores (66%-93%; p ≤ .038), except for speech (p = .341). Concerning function, esthetics and self-esteem, no decrease in satisfaction could be observed until the end of follow-up (90%-96%; p ≥ .057), whereas perception of sense (92%) and speech (95%) increased over time (p ≤ .030). Occurrence of technical complications did not correlate with patient satisfaction. CONCLUSIONS: Bi-layered FDPs made from zirconia/fluor-apatite highly satisfied patients but showed significant incidence of technical complications.


Asunto(s)
Aleaciones Dentales , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Circonio , Adulto , Anciano , Apatitas , Femenino , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Análisis de Supervivencia
17.
Clin Oral Implants Res ; 29 Suppl 18: 196-223, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30306684

RESUMEN

OBJECTIVE: This review aimed at evaluating the survival and technical complication rates of all-ceramic implant-supported single crowns (SC). MATERIAL AND METHODS: Three electronic databases were searched for clinical studies conducted at ≥ 15 patients examining implant-supported all-ceramic SCs over ≥ 12 months. Survival rates of implants and restorations plus technical complication rates of SCs were calculated and tested for statistical correlation with confounding variables. Statistical analysis was performed using a negative binomial distribution model to calculate 5- and 10-year survival and complication estimates. RESULTS: Forty-one included studies reported on implant-supported SCs made of veneered and monolithic high-strength oxide ceramics, monolithic, and veneered glass-based ceramics and of a monolithic resin-nano-ceramic (RNC). Survival estimates for SCs of 93% (95% CI: 86.6%-96.4%) after 5 years and 94.4% (95% CI: 91.1%-96.5%) after 10 years were calculated, corresponding values for implant survival were 95.3% (95% CI: 90.6%-97.7%) and 96.2% (95% CI: 95.1%-97.1%). Technical complication rates after 5/10 years were as follows: chipping 9.0% (95% CI: 5.4%-14.8%)/2.7% (95% CI: 2.1%-3.5%), framework fractures 1.9% (95% CI: 0.7%-4.9%)/1.2% (95% CI: 1%-1.5%), screw loosening 3.6% (95% CI: 1.6%-8.4%)/5.2% (95% CI: 3.6%-7.5%), and decementations with 1.1% (95% CI: 0.4%-2.8%) after 5 years. Some confounding variables influenced the above-mentioned estimates significantly. CONCLUSIONS: All-ceramic implant-supported SCs showed-with the exception of a RNC material-high survival rates. However, failures and technical complications occurred which have to be considered when informing patients on the treatment with implant-supported all-ceramic SCs.


Asunto(s)
Cerámica/uso terapéutico , Coronas , Materiales Dentales/uso terapéutico , Prótesis Dental de Soporte Implantado , Coronas/efectos adversos , Prótesis Dental de Soporte Implantado/efectos adversos , Prótesis Dental de Soporte Implantado/microbiología , Fracaso de la Restauración Dental , Humanos
18.
Clin Oral Implants Res ; 29 Suppl 18: 224-236, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30306694

RESUMEN

OBJECTIVE: To assess the survival and technical complication rate of partial and full-arch all-ceramic implant-supported fixed dental prostheses (P-FDP/FA-FDP) and supporting implants. MATERIALS AND METHODS: An electronic search through three databases (MEDLINE/Pubmed, Cochrane Library, Embase) was conducted to identify relevant clinical studies with an observation period of at least 12 months, including ≥15 patients. Reconstruction and implant survival rates, technical complications and confounding variables such as processed/installed materials, retention mode and location in the mouth were obtained. Failure and complication rates were analyzed using standard Poisson regression models to calculate 5-year survival and complication estimates. RESULTS: A total of five studies for the P-FDP group and seven studies for the FA-FDP group were included, throughout evaluating veneered zirconia reconstructions. In the P-FDP group, reconstructions were located in posterior regions. Meta-analysis indicated survival estimates on the reconstruction level of 98.3% and 97.7% for P- and FA-FDPs after 5 years. However, chipping of the veneering ceramic was frequent, resulting in estimated 5-year complication rates of 22.8% (P-FDPs) and 34.8% (FA-FDPs). Five-year survival estimates of implants supporting P-FDPs and FA-FDPs of 98.5% and 99.4% were calculated, respectively. Including a total of 540 FDPs, one screw-loosening and 11 de-cementations were reported. Confounding variables were not found to have a significant influence on survival and complication rates. CONCLUSIONS: All-ceramic implant-supported P- and FA-FDPs comprising veneered zirconia frameworks showed high survival but clinically inacceptable fracture rates of the veneering ceramic. Their suitability with regard to this indication and a successful long-term outcome needs to be further evaluated.


Asunto(s)
Cerámica/uso terapéutico , Materiales Dentales/uso terapéutico , Dentadura Completa , Dentadura Parcial Fija , Cerámica/efectos adversos , Materiales Dentales/efectos adversos , Prótesis Dental de Soporte Implantado , Fracaso de la Restauración Dental , Dentadura Completa/efectos adversos , Dentadura Parcial Fija/efectos adversos , Humanos
19.
Clin Oral Implants Res ; 29(3): 290-299, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29330869

RESUMEN

AIM: The aim of the present investigation was to evaluate clinically and radiographically the outcome of zirconia oral implants after 3 years in function. MATERIALS AND METHODS: In 60 patients in need of either a single-tooth replacement or a three-unit fixed dental prosthesis (FDP), a total of 71 one-piece zirconia implants were placed and immediately restored with temporary fixed prostheses. After a period of at least 2 months in the mandible and at least 4 months in the maxilla, zirconia-based reconstructions were cemented. The implants were clinically and radiologically examined at implant insertion, prosthetic delivery, at 6 months and then yearly up to 3 years. A linear mixed model was used to analyze statistically the influence of prognostic factors on changes in the marginal bone level. RESULTS: Seventy-one implants (48 in the mandible, 23 in the maxilla) inserted in 60 patients were restored with 49 crowns and 11 FDP. One patient lost his implant after 5 weeks. Five patients with one implant each could not be evaluated after 3 years. Based on 55 patients with a total of 66 implants, the mean survival rate was 98.5% after 3 years in function. A statistically significant mean marginal bone loss (0.70 mm ± 0.72 mm) has been detected from implant insertion to the 3-year follow-up. The largest marginal bone loss occurred between implantation and prosthetic delivery (0.67 mm ± 0.56 mm). After delivery, no statistically significant bone level change was observed (0.02 mm ± 0.59 mm). None of the investigated prognostic factors had a significant influence on changes in the marginal bone level. CONCLUSIONS: After 3 years in function, the investigated one-piece zirconia implant showed a high survival rate and a low marginal bone loss. The implant system was successful for single-tooth replacement and three-unit FDPs. Further investigations with long-term data are needed to confirm these findings.


Asunto(s)
Pérdida de Hueso Alveolar/patología , Implantes Dentales de Diente Único , Implantes Dentales , Prótesis Dental de Soporte Implantado , Fracaso de la Restauración Dental , Dentadura Parcial Fija , Circonio , Adulto , Pérdida de Hueso Alveolar/diagnóstico por imagen , Proceso Alveolar/diagnóstico por imagen , Coronas , Pilares Dentales , Diseño de Implante Dental-Pilar , Implantación Dental Endoósea , Índice de Placa Dental , Diseño de Prótesis Dental , Restauración Dental Provisional , Femenino , Humanos , Carga Inmediata del Implante Dental , Masculino , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Persona de Mediana Edad , Índice Periodontal , Estudios Prospectivos , Análisis de Supervivencia
20.
Clin Oral Implants Res ; 29 Suppl 18: 237-242, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30306691

RESUMEN

OBJECTIVES: The tasks of this working group were to evaluate the existing evidence on the efficiency and efficacy of the digital and conventional workflows for the fabrication of fixed implant reconstructions, to assess the performance of all-ceramic fixed implant reconstructions and, finally, to evaluate the outcomes of internally and externally connected implant abutments and reconstructions. METHODS: Four reviews were available analyzing the current literature on the respective topics. One review dealt with the efficiency and efficacy of digital and conventional fabrication workflows. Two reviews analyzed the outcomes of all-ceramic fixed implant reconstructions, one focusing on single-implant reconstructions and the other evaluating multiple-unit implant fixed dental prostheses (FDPs). The fourth review evaluated the clinical outcome on external, respectively, internal implant-abutment connections. These reviews were the basis for the discussions within the group and at the plenary sessions. RESULTS: The present consensus report gives the consensus statements, the clinical recommendations, and the implications for future research as discussed and approved by the plenum of the consensus conference. The four manuscripts by Mühlemann et al., Rabel et al., Pieralli et al., and Pjetursson et al. are published as part of the journal supplement of the present EAO consensus conference.


Asunto(s)
Diseño Asistido por Computadora , Diseño de Prótesis Dental , Cerámica/uso terapéutico , Coronas , Pilares Dentales , Diseño de Implante Dental-Pilar/métodos , Materiales Dentales/uso terapéutico , Diseño de Prótesis Dental/métodos , Prótesis Dental de Soporte Implantado/métodos , Diseño de Dentadura/métodos , Humanos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda