RESUMEN
BACKGROUND: Scapular notching is a common complication of reverse total shoulder arthroplasty (RTSA). Although the notching rate has reduced significantly thanks to modifications to the surgical technique and humeral and glenoid components, uncontrollable polyethylene (PE)-induced osteolysis can still occur. In contrast to conventional-bearing (CB-RTSA), inverted-bearing RTSA (IB-RTSA) systems, with PE glenospheres and metal or ceramic humeral liners, avoid PE abrasion through scapulohumeral contact. If present, the resulting notch has a different size and configuration than with CB-RTSA. Thus, a modified notching classification seems reasonable. Even in CB-RTSA, the early stages of notching show a different configuration than implied by the established Nerot-Sirveaux classification; therefore, a modification of the classification system is recommended. METHODS: In a prospective multicentre study, 250 cases underwent IB-RTSA. Of these, 39 died, and 28 were lost to follow-up for other reasons, leaving 183 shoulders for the final follow-up examination at a mean of 120.7 months (range 84.1-172.4 months). In the CB-RTSA group, we retrospectively evaluated radiographs of 59 consecutive patients with a follow-up ranging from 2 to 7 years. We analysed the appearance, evolution over time, and location of bone loss on the scapular neck according to the modified Nerot-Sirveaux classification. RESULTS: In IB-RTSA, notching resulted in a new morphological configuration: In contrast to the Nerot-Sirveaux classification, notching began far from the baseplate as an impression or abrasion of the humeral component in the inferior scapular rim. Due to simultaneous mechanical ablation, the defect gradually enlarged, but usually did not contact the baseplate or extend beyond the inferior peg. No signs of PE-induced osteolysis were found. The notching rate reached 19% after 2 years and approached 36% after 10 years. Most shoulders had grade 0 notching (64%), followed by grade 1 (29%); extensive erosion (grade 4) was not observed. In the CB-RTSA group, a small bony impression or erosion without signs of PE-induced osteolysis was observed medial to the scapular neck, without contact with the metaglene in the early phase, which was similar to the impression of the humeral component in IB-RTSA. The notching rate was 86% for CB-RTSA. CONCLUSIONS: A new classification was developed for IB-RTSA, which corresponds to the pathophysiological processes and is compatible with the existing Nerot-Sirveaux classification. Bone erosion in CB-RTSA is not adequately represented by the established classification in the early stages. For this reason, a supplement to the existing classification is presented. LEVEL OF EVIDENCE: Level 4, Case Series, Treatment Study.
RESUMEN
BACKGROUND: Scapular notching is a common complication of reverse total shoulder arthroplasty (RTSA). Inverted-bearing RTSA (IB-RTSA) systems, with polyethylene (PE) glenospheres and metal or ceramic humeral liners, reduce notching and PE wear compared with traditional Grammont prosthesis designs. However, whether notching after IB-RTSA influences clinical outcomes or complications remains unknown. Therefore, we evaluated the influence of notching on midterm clinical outcomes and complication rates after IB-RTSA. METHODS: In our prospective multicenter, observational study, patients underwent IB-RTSA, using a prosthesis system with a PE glenosphere and a metal humeral component. We assessed patients clinically for functional scores, active range of motion, and pain and radiographically for notching. RESULTS: Overall, 270 patients (284 shoulders) were treated with IB-RTSA. Of these, 229 shoulders were available for a mean follow-up of 86.7 months (range, 24.0-133.4 months). We observed notching in 35% of shoulders (28% grade 1; 3% grade 2; and 4% grade 3). IB-RTSA led to a distinct type of notching representing the mechanical indent of the humeral component into the scapular neck without PE-induced osteolysis. Patients with and without notching showed similar clinical outcomes (P ≥ .05), complication rates (P = .23), revision rates (P = .87), and survival of implant components after 10 years (P = .85). CONCLUSIONS: Midterm results confirmed our hypothesis that patients with notching had equally good clinical outcomes and low complication rates as patients without notching. Additionally, we found a distinct type of notching without signs of PE-induced osteolysis.
Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Prótesis de Hombro , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/métodos , Estudios de Seguimiento , Humanos , Estudios Prospectivos , Diseño de Prótesis , Rango del Movimiento Articular , Articulación del Hombro/cirugía , Prótesis de Hombro/efectos adversos , Resultado del TratamientoRESUMEN
INTRODUCTION: Reverse total shoulder arthroplasty (RTSA) is a widely recognized treatment to reduce pain and improve shoulder function for patients in various disease stages of cuff tear arthropathy (CTA). However, it remains unclear whether outcomes after RTSA depend on the preoperative stage of CTA. Therefore, this study evaluated whether the Hamada classification influences midterm clinical outcomes after RTSA. MATERIALS AND METHODS: In this multicenter observational study, patients underwent inverted bearing RTSA for massive rotator cuff tears or CTA. Shoulders were grouped into those with (Hamada grades 4a, 4b, and 5) and those without (Hamada grades 1, 2, and 3) glenohumeral arthritis. Clinical outcomes, including range of motion, Constant score, American Shoulder and Elbow Surgeons score, and visual analog scale for pain and satisfaction, were determined preoperatively and at 24 and > 30 months. All complications were recorded, and survival free from any implant component revision was calculated. RESULTS: Overall, 202 patients (211 shoulders) were treated with RTSA at a mean age of 75.8 ± 6.6 years (range 41.9-91.6 years). Of these, 144 patients (151 shoulders) were available for a mean follow-up of 79.9 ± 24.7 months (range 30.2-132.3 months). No significant between-group differences were found for clinical outcomes at 24 and > 30 months (P > 0.05). Furthermore, the Hamada classification did not correlate with clinical outcomes at 24 (P = 0.98) and > 30 months (P = 0.29). Revision-free implant component survival was similar between groups (P = 0.17). Postoperative complications were found in 11 shoulders, of which 10 required revision. CONCLUSIONS: Inverted bearing RTSA was found to be an effective treatment with similarly good midterm clinical outcomes, similar revision rates, and high implant survival rates in every stage of massive rotator cuff tears. Overall, the preoperative Hamada classification did not influence clinical outcomes or complications after RTSA.
Asunto(s)
Artroplastía de Reemplazo de Hombro , Lesiones del Manguito de los Rotadores , Articulación del Hombro , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia , Humanos , Persona de Mediana Edad , Rango del Movimiento Articular , Estudios Retrospectivos , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/cirugía , Articulación del Hombro/cirugía , Resultado del TratamientoRESUMEN
BACKGROUND: Although shoulder arthroplasty is less common than knee or hip arthroplasty, the number of procedures being performed is increasing rapidly. The treatment effect is a simple method to measure outcome of joint replacement. The method was applied to measure results of total hip/knee arthroplasty but not yet for shoulder arthroplasty. METHODS: Included were patients with unilateral cuff arthropathy (Hamada grades > = 2) treated with reversed total shoulder arthroplasty (RSA) in this prospective multicenter study. The patients were assessed with the ASES questionnaire. The treatment effects (TE) was calculated for each patient. TE = score reduction/baseline score. A positive TE means amelioration, TE = 0 unchanged, and a negative TE means worse. The primary aim was to calculate the TE's for RSA at 6, 12, 24, and 60 months postoperatively. The secondary aim was to analyze the influence of confounders (preoperative Hamada grade, age, gender, dominance, side of the affected shoulder, general co-morbidities measured using ASA grade). RESULTS: Two hundred three patients were included for this analysis of whom 183 patients had a complete 2 year follow up. Two years postoperatively the mean ASES score augmented significant from 20.5 to 78.7 (p < 0.001). The 2 year TE's ranged from 1 to 0.09. We had no patient with a negative TE. A higher Hamada grade was associated with better TE's (Hamada grade 4+ vs. 2, p-value 0.042). For age and dominant side there were weak associations where those aged 80+ and dominant side had better TE's. The patients with higher ASA grade had lower TE's (ASA grade 4+ vs. 1, p-value 0.013). The mean TE's were 0.77 at 6-months, 0.81 at 1 year, 0.76 at 2 years and 0.73 at 5 years. CONCLUSIONS: The outcome for reverse shoulder arthroplasty can be measured with the treatment effect method; the 2 years TE's vary from 1 to 0.09. The mean treatment effects change little in the first five postoperative years (from 0.73 to 0.81). The confounders for better TE's were: higher severity of cuff arthropathy (Hamada grade 3, 4 and 5), less co-morbidities (ASA Grade 1), higher age (80+) and dominant side. Gender did not influence the 2-year TE's. TRIAL REGISTRATION: Comité intercantonal d'éthique (Jura, Fribourg, Neuchâtel), number 01/2008, 24.09.2008.
Asunto(s)
Artroplastía de Reemplazo de Hombro , Indicadores de Salud , Artropatía por Desgarro del Manguito de los Rotadores/cirugía , Encuestas y Cuestionarios , Adulto , Anciano , Anciano de 80 o más Años , Europa (Continente) , Femenino , Estado de Salud , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Artropatía por Desgarro del Manguito de los Rotadores/fisiopatología , Factores de Tiempo , Resultado del TratamientoRESUMEN
Background: Despite the increasing use of revision reverse total shoulder arthroplasty (RTSA), studies directly comparing revision RTSA performed for different failed index procedures are limited. We therefore compared the results of revision RTSA between patients with a failed primary anatomic arthroplasty (total shoulder arthroplasty and hemiarthroplasty) and those with a failed primary RTSA to explore revision of which index procedure resulted in better long-term clinical outcomes. Methods: In this prospective, multicenter, observational study, patients underwent revision RTSA using an inverted-bearing prosthesis. We recorded clinical scores, active range of motion, pain, satisfaction, and the rate of scapular notching. Complications and prosthesis survival were also noted. Results: We included 45 patients (45 shoulders) with revision RTSA for failed primary anatomic shoulder arthroplasty (30 patients) and RTSA (15 patients). Clinical and radiographic outcomes were recorded from 36 patients at a median follow-up of 101.6 months, and prosthesis survival was assessed from all 45 patients. At final follow-up, clinical scores (P < .05), abduction (P = .032), re-revision rate (P = .018), and prosthesis survival (P = .015) were significantly better in patients revised from failed primary anatomic shoulder arthroplasty than those from RTSA. However, pain, satisfaction, and overall complication rates were similar in both groups (P > .05). Conclusions: We found better long-term clinical scores, abduction, and prosthesis survival rates after failed primary anatomic shoulder arthroplasty than after RTSA. Pain reduction and complication rates were comparable in both groups. Thus, anatomic shoulder arthroplasty remains an attractive option for primary arthroplasty in selected cases.
RESUMEN
OBJECTIVE: To investigate the technical feasibility of harvesting a vascularized bone graft from the acromion pedicled on the acromial branch. BACKGROUND: Complex fractures of the proximal humerus may result in partial or total avascular necrosis of the head fragment. Treatment of avascular necrosis of the humeral head is dependent upon the stage of disease as well as the dimension and location of necrosis. In general, the outcome is poor and complete restoration of the shoulder function is rarely attained. Contrary to osteonecrosis of carpal bones (where vascularized bone grafts have been routinely carried out for decades), reports of analogous procedures at the humeral head are anecdotal. METHODS: Based on selective post-mortem computer-tomographic angiography of 5 and the dissection of 30 embalmed human cadaver shoulders, we describe the anatomy of the acromial branch of the thoracoacromial trunk. The main focus was the constancy of its anatomical course, its dimensions and potential use as a nutrient vessel for a pedicled bone graft from the acromion. RESULTS: The course of the acromial branch revealed a constant topographic relationship to anatomical landmarks. Its terminal branches reliably supplied the anterior part of the acromion. The vascularized bone graft could be sufficiently mobilized to allow tension-free transfer to the humeral head as well as to the lateral two-thirds of the clavicle. CONCLUSION: We demonstrated the feasibility of vascularized bone graft harvesting from the acromion. This technique could be a joint-preserving procedure for osteonecrosis of the humeral head or may assist in the revision of a clavicular pseudoarthrosis.
Asunto(s)
Acromion/anatomía & histología , Acromion/trasplante , Trasplante Óseo , Fracturas del Hombro/cirugía , Colgajos Quirúrgicos , Anciano , Anciano de 80 o más Años , Cadáver , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Ortopédicos/métodosRESUMEN
The purpose of this study is to evaluate the mid-term clinical results of an ongoing case series on conversion reverse shoulder arthroplasty (RSA) with a modular prosthesis system. We included 17 elderly patients revised for failed hemiarthroplasty after proximal humeral fracture, of which 13 were converted using a modular reverse shoulder prosthesis. Four could not be converted due to overstuffing. For the conversion RSA, we determined the Constant score, American Shoulder and Elbow Surgeons Shoulder Score, visual analogue scale for pain and satisfaction, and range of motion preoperatively, at one year, and at the last follow-up. All measured clinical outcomes improved significantly at both follow-up time points (p < 0.05). The mean duration of surgery was 118.4 min (range: 80.0 to 140.0 min). We observed complications in three patients; these included one late infection and two aseptic stem loosenings. Modular shoulder arthroplasty is a suitable procedure for conversion RSA in elderly patients. All measured postoperative clinical outcomes improved significantly, the complication rate was acceptable, and no prosthesis-related complications occurred. Conversion RSA, although not feasible in every case, is a viable treatment option in the elderly, which can provide successful mid-term results.
RESUMEN
Arthrodesis is the generally accepted treatment for symptomatic osteoarthritis of the interphalangeal (IP) joint of the thumb. For 7 thumbs in 5 patients, an IP joint replacement was offered as a pain alleviating and motion conserving treatment option for osteoarthritis. In these cases, an offlabel use of the SR-PIP prosthesis was performed. All patients did well postoperatively with reasonable pain-free range of motion of the interphalangeal joint except one patient who required further surgeries for recurring joint instability. Radiologically, though, an osteolysis around the stems that could lead to loosening of the prosthesis and progressing periarticular ossifications that might cause a blockage of the joint were observed. IP joint arthroplasty represents a viable option on the short term; however, further studies should be conducted to ensure their long-term sustainability.
RESUMEN
The notching phenomenon is one of the major concerns with reversed total shoulder arthroplasty. Repetitive contact between the humeral implant and the scapula (mechanical notching) produces progressive abrasion of the implant if the moving part is made of polyethylene. Its debris may then lead to active osteolysis (biological notching). Inversion of bearing materials, i.e. Glenosphere made of polyethylene and humeral Inlay made of metal, aims at the reduction of this phenomenon. However, the question arises if the tribological behavior would then be different. On an experimental setup, the gravimetric wear of both material configurations was measured after loading and moving over 500,000 cycles. The abrasion of the polyethylene Inlay due to mechanical notching was calculated by means of 3D CAD models with different notching stages. The loss of mass due to gravimetric wear was compared to the loss of mass caused by mechanical notching. After 500,000 cycles the measured amount of wear of the polyethylene components was between 8 and 10 mg for both tribological pairings. The calculated loss of mass of the polyethylene Inlay caused by mechanical notching ranged from 73 to 3881 mg. The results of this study indicate that the gravimetric polyethylene wear in the estimated life-time is very low and not significantly different between both material configurations. However, the polyethylene abrasion due to mechanical notching in the configuration with polyethylene Inlay is by far more important than any gravimetric wear. These results support the continued use of inverted bearings in reversed total shoulder arthroplasty.
Asunto(s)
Prótesis Articulares/efectos adversos , Hombro/fisiología , Artroplastia de Reemplazo , Análisis de Falla de Equipo/métodos , Humanos , Polietileno/química , Diseño de Prótesis , Hombro/cirugíaRESUMEN
BACKGROUND: A possible difficulty in intra-articular fracture of the distal radius is the displacement tendency of the radial styloid process due to the tension of the brachioradialis tendon. METHODS: Ten patients treated within one year for complex distal radius fractures by double-plating technique with a radial buttress plate and volar locking plate, through a single volar approach, were followed prospectively during 24 months. Outcome measures included radiographic follow-up, range of motion, grip strength and score follow-up (VAS, Gartland-Werley score and patient-rated wrist evaluation). RESULTS: Ten patients with intraarticular distal radius fractures with dislocation of the radial styloid process were treated with this technique. This resulted after 24 months in good clinical outcome (mean visual analog scale 0.9; almost symmetric range of motion; mean Gartland-Werley score 2 +/- 3; mean patient-rated wrist evaluation 3.2 +/- 2.4). Radiologic evaluation according to the Dresdner Score revealed anatomic reduction without secondary dislocation during the follow-up and uneventful consolidation. CONCLUSIONS: The described technique strongly facilitates anatomic reduction and stable fixation of intra-articular distal radius fractures with dislocation of the radial styloid process and leads to satisfactory clinical and radiographic outcome.
RESUMEN
OBJECTIVES: The goal of this study is to evaluate the incidence of complications and the functional outcome after open reduction and internal fixation with the proximal humeral locking plate (Philos). DESIGN: Prospective case series. SETTING: Multicenter study in 8 trauma units (levels I, II, and III) with recruitment between September 12, 2002, and January 9, 2005. PATIENTS: One hundred fifty-seven patients with 158 fractures. INTERVENTION: Open reduction and internal fixation with a Philos plate. MAIN OUTCOME MEASUREMENTS: Occurrence of postoperative complications up to 1 year and active follow-up for 1 year with radiologic assessment to observe fracture healing, alignment, reduction, avascular necrosis, and functional outcome measurements including Constant, Disabilities of the Arm, Shoulder, and Hand, and Neer scores. RESULTS: One-year follow-up rate was 84%. The incidence of experiencing any implant-related complication was 9% and 35% for nonimplant-related complications. Primary screw perforation was the most frequent problem (14%) followed by secondary screw perforation (8%) and avascular necrosis (8%). After 1 year, a mean Constant score of 72 points (87% of the contralateral noninjured side), a mean Neer score of 76 points, and a mean Disabilities of the Arm, Shoulder, and Hand score of 16 points were achieved. CONCLUSIONS: Fixation with Philos plates preserves achieved reduction, and a good functional outcome can be expected. However, complication incidence proportions are high, particularly due to primary and secondary screw perforations into the glenohumeral joint, with an overall complication rate of 35%. More accurate length measurement and shorter screw selection should prevent primary screw perforation. Awareness of obtaining anatomic reduction of the tubercles and restoring the medial support should reduce the incidence of secondary screw perforations, even in osteopenic bone.