Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Eur Heart J ; 39(28): 2646-2655, 2018 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-29617762

RESUMEN

Aims: Echocardiography and tomographic imaging have documented dynamic changes in aortic stenosis (AS) geometry and severity during both the cardiac cycle and stress-induced increases in cardiac output. However, corresponding pressure gradient vs. flow relationships have not been described. Methods and results: We recruited 16 routine transcatheter aortic valve implantations (TAVI's) for graded dobutamine infusions both before and after implantation; 0.014″ pressure wires in the aorta and left ventricle (LV) continuously measured the transvalvular pressure gradient (ΔP) while a pulmonary artery catheter regularly assessed cardiac output by thermodilution. Before TAVI, ΔP did not display a consistent relationship with transvalvular flow (Q). Neither linear resistor (median R2 0.16) nor quadratic orifice (median R2 < 0.01) models at rest predicted stress observations; the severely stenotic valve behaved like a combination. The unitless ratio of aortic to left ventricular pressures during systolic ejection under stress conditions correlated best with post-TAVI flow improvement. After TAVI, a highly linear relationship (median R2 0.96) indicated a valid valve resistance. Conclusion: Pressure loss vs. flow curves offer a fundamental fluid dynamic synthesis for describing aortic valve pathophysiology. Severe AS does not consistently behave like an orifice (as suggested by Gorlin) or a resistor, whereas TAVI devices behave like a pure resistor. During peak dobutamine, the ratio of aortic to left ventricular pressures during systolic ejection provides a 'fractional flow reserve' of the aortic valve that closely approximates the complex, changing fluid dynamics. Because resting assessment cannot reliably predict stress haemodynamics, 'valvular fractional flow' warrants study to explain exertional symptoms in patients with only moderate AS at rest.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/fisiología , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Presión Sanguínea , Femenino , Humanos , Masculino , Flujo Sanguíneo Regional , Índice de Severidad de la Enfermedad , Factores de Tiempo
2.
Lancet ; 390(10105): 1843-1852, 2017 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-28851504

RESUMEN

BACKGROUND: The development of coronary drug-eluting stents has included use of new metal alloys, changes in stent architecture, and use of bioresorbable polymers. Whether these advancements improve clinical safety and efficacy has not been shown in previous randomised trials. We aimed to examine the clinical outcomes of a bioresorbable polymer sirolimus-eluting stent compared with a durable polymer everolimus-eluting stent in a broad patient population undergoing percutaneous coronary intervention. METHODS: BIOFLOW V was an international, randomised trial done in patients undergoing elective and urgent percutaneous coronary intervention in 90 hospitals in 13 countries (Australia, Belgium, Canada, Denmark, Germany, Hungary, Israel, the Netherlands, New Zealand, South Korea, Spain, Switzerland, and the USA). Eligible patients were those aged 18 years or older with ischaemic heart disease undergoing planned stent implantation in de-novo, native coronary lesions. Patients were randomly assigned (2:1) to either an ultrathin strut (60 µm) bioresorbable polymer sirolimus-eluting stent or to a durable polymer everolimus-eluting stent. Randomisation was via a central web-based data capture system (mixed blocks of 3 and 6), and stratified by study site. The primary endpoint was 12-month target lesion failure. The primary non-inferiority comparison combined these data from two additional randomised trials of bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent with Bayesian methods. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT02389946. FINDINGS: Between May 8, 2015, and March 31, 2016, 4772 patients were recruited into the study. 1334 patients met inclusion criteria and were randomly assigned to treatment with bioresorbable polymer sirolimus-eluting stents (n=884) or durable polymer everolimus-eluting stents (n=450). 52 (6%) of 883 patients in the bioresorbable polymer sirolimus-eluting stent group and 41 (10%) of 427 patients in the durable polymer everolimus-eluting stent group met the 12-month primary endpoint of target lesion failure (95% CI -6·84 to -0·29, p=0·0399), with differences in target vessel myocardial infarction (39 [5%] of 831 patients vs 35 [8%] of 424 patients, p=0·0155). The posterior probability that the bioresorbable polymer sirolimus-eluting stent is non-inferior to the durable polymer everolimus-eluting stent was 100% (Bayesian analysis, difference in target lesion failure frequency -2·6% [95% credible interval -5·5 to 0·1], non-inferiority margin 3·85%, n=2208). INTERPRETATION: The outperformance of the ultrathin, bioresorbable polymer sirolimus-eluting stent over the durable polymer everolimus-eluting stent in a complex patient population undergoing percutaneous coronary intervention suggests a new direction in improving next generation drug-eluting stent technology. FUNDING: BIOTRONIK.


Asunto(s)
Implantes Absorbibles , Stents Liberadores de Fármacos , Everolimus , Intervención Coronaria Percutánea , Sirolimus , Teorema de Bayes , Enfermedad de la Arteria Coronaria/terapia , Forma MB de la Creatina-Quinasa/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Polímeros , Estudios Prospectivos , Diseño de Prótesis
3.
Am Heart J ; 193: 35-45, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29129253

RESUMEN

BACKGROUND: Traditional study design submitted to the Food and Drug Administration to test newer drug-eluting stents (DES) for marketing approval is the prospective randomized controlled trial. However, several DES have extensive clinical data from trials conducted outside the United States that have led to utilization of a novel design using the Bayesian approach. This design was proposed for testing DES with bioresorbable polymer compared with DES most commonly in use today that use durable polymers for drug elution. STUDY DESIGN AND OBJECTIVES: This prospective, multicenter, randomized, controlled trial is designed to assess the safety and efficacy of the Orsiro bioresorbable polymer sirolimus-eluting stent (BP SES). Up to 1,334 subjects with up to 3 de novo or restenotic coronary artery lesions who qualify for percutaneous coronary intervention with stenting will be randomized 2:1 to the BP SES versus the Xience durable polymer everolimus-eluting stent (DP EES). Data from this trial will be combined with data from 2 similarly designed trials that also randomize subjects to BP SES and DP EES (BIOFLOW II, N=452 and BIOFLOW IV, N=579) by using a Bayesian approach. The primary end point is target lesion failure at 12 months post index procedure, defined as cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization, and the primary analysis is a test of noninferiority of the BP SES versus DP EES on the primary end point according to a noninferiority delta of 3.85%. Secondary end points include stent thrombosis and the individual components of target lesion failure. Subjects will be followed for 5 years after randomization. CONCLUSIONS: The BIOFLOW V trial offers an opportunity to assess clinical outcomes in patients treated with coronary revascularization using the Orsiro BP SES relative to a commonly used DP EES. The use of a Bayesian analysis combines a large randomized cohort of patients 2 two smaller contributing randomized trials to augment the efficiency of the comparison.


Asunto(s)
Implantes Absorbibles , Teorema de Bayes , Estenosis Coronaria/cirugía , Stents Liberadores de Fármacos , Revascularización Miocárdica/métodos , Sirolimus/farmacología , Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
4.
Cardiovasc Diabetol ; 16(1): 23, 2017 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-28183306

RESUMEN

OBJECTIVE: To report the long-term safety and efficacy data of a third generation drug eluting stent (DES) with biodegradable polymer in the complex patient population of diabetes mellitus after a follow-up period of 5 years. BACKGROUND: After percutaneous coronary intervention patients with diabetes mellitus are under higher risk of death, restenosis and stent thrombosis (ST) compared to non-diabetic patients. METHODS: In 126 centers worldwide 3067 patients were enrolled in the NOBORI 2 registry, 888 patients suffered from diabetes mellitus (DM), 213 of them (14%) being insulin dependent (IDDM). Five years follow-up has been completed in this study. RESULTS: At 5 years, 89.3% of the patients were available for follow-up. The reported target lesion failure (TLF) rates at 5 years were 12.39% in DM group and 7.34% in non-DM group; (p < 0.0001). In the DM group, the TLF rate in patients with IDDM was significantly higher than in the non-IDDM subgroup (17.84 vs. 10.67%; p < 0.01). The rate of ST at 5 years was not different among diabetic versus non-diabetic patients or IDDM versus NIDDM. Only 10 (<0.4%) very late stent thrombotic events beyond 12 months occurred. CONCLUSIONS: The Nobori DES performed well in patients with DM. As expected patients with DM, particularly those with IDDM, had worse outcomes. However, the very low rate of very late stent thrombosis in IDDM patients might have significant clinical value in the treatment of these patients. Clinical trial registration ISRCTN81649913; http://www.controlled-trials.com/isrctn/search.html?srch=81649913&sort=3&dir=desc&max=10.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus/tratamiento farmacológico , Stents Liberadores de Fármacos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/etiología , Trombosis Coronaria/etiología , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Femenino , Humanos , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
6.
J Behav Med ; 37(1): 135-44, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23180285

RESUMEN

In this study effects of a brief mindfulness-based stress reduction intervention were examined in cardiac patients who had a percutaneous coronary intervention (PCI). One-hundred-and-fourteen patients (mean age 55 ± 7 years, 18 % women) were randomly assigned to a 4-session mindfulness group intervention or a minimal mindfulness self-help control group that received a booklet containing identical information. Compared to self-help, the group intervention showed larger increases in psychological and social quality of life (p < .05, partial η(2) = .04 and .05, respectively). For symptoms of anxiety and depression, and for perceived stress, this effect was evident only in patients younger than 60 years (p < .01, partial η(2) = .10 and .15, respectively). These effects were partially or fully mediated by increase in mindfulness. The brief group mindfulness intervention seems beneficial for cardiac PCI patients regarding general psychosocial quality of life, although for specific psychological symptoms, this intervention can be recommended only for nonelderly patients.


Asunto(s)
Emociones , Atención Plena , Intervención Coronaria Percutánea/psicología , Calidad de Vida/psicología , Estrés Psicológico/terapia , Adulto , Anciano , Ansiedad/psicología , Ansiedad/terapia , Depresión/psicología , Depresión/terapia , Femenino , Humanos , Masculino , Salud Mental , Persona de Mediana Edad , Satisfacción Personal , Autocuidado , Estrés Psicológico/psicología , Resultado del Tratamiento
7.
Heart Vessels ; 28(1): 1-6, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22038109

RESUMEN

Stent boost (SB) imaging is an enhancement of the radiologic edge of the stent by digital management of regular X-ray images. The purpose of the present study was to validate SB imaging by comparison with the anatomical standard using intravascular ultrasound (IVUS). We investigated SB and IVUS after stent implantation in 68 arteries in 60 patients. Based on those findings, we added high-pressure dilatation in four patients and another stent implantation in four patients. We defined the SB criteria for adequate stent deployment as: complete stent expansion, stent minimum diameter ≥70% of reference diameter, and stent minimum diameter ≥2.0 mm; and IVUS criteria for adequate stent deployment as: minimal stent area ≥5.0 mm(2). If the reference vessel was <2.8 mm, adequate stent deployment was defined as minimum stent area ≥4.5 mm(2). IVUS findings indicated inadequate stent deployment in 21/72 observations (29%). Seven SB images showed inadequate stent expansion. SB predicted inadequate findings of IVUS with 100% specificity, 33% sensitivity, and 81% agreement. Although the sensitivity of SB image for adequate stent deployment is low, the specificity is sufficiently high for it to be the first-line for monitoring just after stent implantation in centers where IVUS is not used routinely.


Asunto(s)
Síndrome Coronario Agudo/cirugía , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Stents , Ultrasonografía Intervencional/métodos , Síndrome Coronario Agudo/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
9.
JACC Cardiovasc Interv ; 15(18): 1852-1860, 2022 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-36137689

RESUMEN

BACKGROUND: Randomized trials have demonstrated the superiority of ultrathin strut drug-eluting stents compared with alternative stent designs. Whether these differences persist over late-term follow-up is uncertain. OBJECTIVES: This study sought to compare late-term (5-year) clinical outcomes among patients treated with ultrathin strut (60 µm) bioresorbable polymer sirolimus-eluting stents (BP SES) and thin strut (81 µm) durable polymer everolimus-eluting stents (DP EES). METHODS: BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects with Up to Three De Novo or Restenotic Coronary Artery Lesions V) was an international, 2:1 randomized trial comparing percutaneous coronary intervention with ultrathin strut BP SES versus thin strut DP EES regarding the primary endpoint of 12-month target lesion failure (TLF). Prespecified outcomes through 5 years were assessed. RESULTS: Among 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 5-year rates of TLF were 12.3% for BP SES and 15.3% for DP EES (P = 0.108). Revascularization with BP SES was associated with a significantly lower target vessel-related myocardial infarction (6.6% vs 10.3%, P = 0.015) and late/very late definite/probable stent thrombosis (0.3% vs 1.6%, P = 0.021). Ischemia-driven target lesion revascularization was numerically but not significantly lower with BP SES (5.9% vs 7.7%, P = 0.202). Cardiac death rates were 2.6% versus 1.9% (P = 0.495) for BP SES and DP EES, respectively. CONCLUSIONS: In a large, randomized trial, TLF and the individual outcomes of cardiac death and target lesion revascularization at 5 years were similar among patients treated with BP SES versus DP EES. Both target vessel-related myocardial infarction and late/very late definite/probable stent thrombosis were significantly lower with BP SES. These results confirm the durability of safety and the effectiveness of percutaneous coronary intervention with ultrathin BP SES.


Asunto(s)
Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Implantes Absorbibles , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/terapia , Muerte , Everolimus/efectos adversos , Humanos , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/efectos adversos , Resultado del Tratamiento
10.
Circulation ; 119(6): 828-34, 2009 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-19188507

RESUMEN

BACKGROUND: There are limited data on the long-term clinical outcome after an angiographically confirmed (definite) stent thrombosis (ST). METHODS AND RESULTS: Four hundred thirty-one consecutive patients with a definite ST were enrolled in this multicenter registry. The primary end point was the composite of cardiac death and definite recurrent ST. Secondary end points were all-cause death, cardiac death, definite recurrent ST, definite and probable recurrent ST, any myocardial infarction, and any target-vessel revascularization. The primary end point occurred in 111 patients after a median follow-up of 27.1 months. The estimated cumulative event rates at 30 days and 1, 2, and 3 years were 18.0%, 23.6%, 25.2%, and 27.9%, respectively. The cumulative incidence rates of definite recurrent ST, definite or probable recurrent ST, any myocardial infarction, and any target-vessel revascularization were 18.8%, 20.1%, 21.3%, and 32.0%, respectively, at the longest available follow-up. Independent predictors for the primary end point were diabetes mellitus, total stent length, severe calcification, American College of Cardiology/American Heart Association B2-C lesions, TIMI (Thrombolysis In Myocardial Infarction) flow grade <3 after percutaneous coronary intervention, and left ventricular ejection fraction <45%. The implantation of an additional coronary stent during the first ST was also associated with unfavorable outcome. Clinical outcome was not affected by the type of previously implanted stent (drug-eluting or bare-metal stent) or the category of ST (early versus late). CONCLUSIONS: The long-term clinical outcome after a first definite ST is unfavorable, with a high mortality and recurrence rate. Diabetes mellitus, left ventricular ejection fraction <45%, long total stent length, complex coronary lesions, TIMI flow grade <3 after percutaneous coronary intervention, and implantation of an additional coronary stent during the emergent percutaneous coronary intervention for the ST were associated with this unfavorable outcome.


Asunto(s)
Trombosis Coronaria/epidemiología , Trombosis Coronaria/etiología , Stents/efectos adversos , Anciano , Angiografía , Trombosis Coronaria/diagnóstico , Trombosis Coronaria/mortalidad , Muerte , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio , Recurrencia , Sistema de Registros , Factores de Riesgo , Resultado del Tratamiento
11.
JACC Cardiovasc Interv ; 13(11): 1343-1353, 2020 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-32499026

RESUMEN

OBJECTIVES: The aim of this study was to compare late-term clinical outcomes among patients treated with ultrathin-strut (60-µm) bioresorbable-polymer sirolimus-eluting stents (BP SES) and thin-strut (81µm) durable-polymer everolimus-eluting stents (DP EES). BACKGROUND: Emerging evidence from comparative studies of drug-eluting stents demonstrates improved safety and efficacy with ultrathin-strut drug-eluting stents, but limited insight exists regarding late-term outcomes. METHODS: BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects With Up to Three De Novo or Restenotic Coronary Artery Lesions V) is an international randomized trial comparing coronary revascularization with BP SES and DP EES regarding the primary endpoint of 12-month target lesion failure. Analysis of pre-specified 3-year clinical outcomes was performed. RESULTS: Among 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 3-year rate of target lesion failure was 8.2% for BP SES and 13.6% for DP EES (p = 0.002), driven by differences in both target vessel myocardial infarction (MI) (5.0% vs. 9.2%; p = 0.003) and clinically driven target lesion revascularization (3.2% vs. 6.7%; p = 0.006). In landmark analysis, significant differences in target vessel MI and target lesion revascularization were observed favoring treatment with BP SES. Definite or probable late or very late stent thrombosis was significantly lower with BP SES (0.1% vs. 1.2%; p = 0.018). Cardiac death or MI rates were 7.7% and 11.7% (p = 0.017) for BP SES and DP EES, respectively. CONCLUSIONS: In a large randomized trial, both target lesion failure and the outcomes of target vessel MI, clinically driven target lesion revascularization, and late or very late stent thrombosis at 3 years were significantly lower among patients treated with BP SES versus DP EES. The results endorse the continued superiority of ultrathin-strut BP SES compared with DP EES. (Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions [BIOFLOW-V]; NCT02389946).


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
12.
Am J Cardiol ; 124(7): 1020-1026, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31353004

RESUMEN

Patients with diabetes mellitus are prone to increased adverse outcomes after percutaneous coronary intervention, even with contemporary drug-eluting stents. Randomized controlled trials have demonstrated comparable clinical outcomes between an ultrathin bioresorbable-polymer sirolimus-eluting stent (BP-SES) and a thin-strut durable-polymer everolimus-eluting stent (DP-EES) that has specific labeling for patients with diabetes. We aimed to evaluate the safety and efficacy of the BP-SES in patients with diabetes mellitus. To determine the performance of the BP-SES in diabetic patients, patient-level data from the BIOFLOW II, IV, and V randomized controlled trials were pooled. The primary end point was target lesion failure (TLF), defined as the composite of cardiovascular death, target-vessel myocardial infarction, ischemia-driven target lesion revascularization, and definite or probable stent thrombosis, at 1 year. Among 1,553 BP-SES and 791 DP-EES patients, 757 diabetic patients were identified. Of the diabetic patients included in this analysis (494 BP-SES vs 263 DP-EES), the proportion of insulin- and noninsulin-treated patients was similar between groups. The 1-year TLF rate in the diabetic population was 6.3% in the BP-SES group and 8.7% in the DP-EES group (hazard ratio 0.82, 95% confidence interval 0.047 to 1.43, p = 0.493). There were no significant differences, based on stent type or diabetes treatment regimen, in TLF hazards. In a patient-level pooled analysis of the diabetic population from randomized trials, 1-year clinical safety and efficacy outcomes were similar in patients treated with ultrathin BP-SES and thin-strut DP-EES.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Complicaciones de la Diabetes/complicaciones , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Sirolimus/administración & dosificación , Anciano , Enfermedad de la Arteria Coronaria/complicaciones , Complicaciones de la Diabetes/terapia , Diseño de Equipo , Femenino , Humanos , Inmunosupresores/administración & dosificación , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/instrumentación , Polímeros , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 72(2): 248-56, 2008 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-18655149

RESUMEN

Fractional Flow Reserve (FFR), calculated by coronary pressure measurement, is the invasive gold standard to assess the hemodynamic significance of a coronary stenosis. FFR reliably indicates whether a stenosis is responsible for inducible ischemia and if percutaneous coronary intervention is appropriate. False positive or negative FFR is rare. Occasionally, however, a clinical or angiographic condition is encountered in which in first instance the FFR measurement contradicts the intuitive feeling of the interventionalist. Further examination in such cases, however, often reveals a clear physiologic explanation and in this manner FFR "lifts the veil". Two such patients are presented in this case report and the reasons for apparent or actual false positive or negative FFR are discussed.


Asunto(s)
Presión Sanguínea , Circulación Coronaria , Estenosis Coronaria/diagnóstico , Anciano , Angiografía Coronaria , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/terapia , Ecocardiografía , Reacciones Falso Negativas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Embolia Pulmonar/diagnóstico , Stents
14.
J Am Coll Cardiol ; 72(25): 3287-3297, 2018 12 25.
Artículo en Inglés | MEDLINE | ID: mdl-30257191

RESUMEN

BACKGROUND: Coronary drug-eluting stent development has introduced new metal alloys, changes in stent architecture, and bioresorbable polymers. Whether these advancements improve long-term clinical safety and efficacy has been inconsistent in prior studies. OBJECTIVES: The authors sought to compare late-term clinical outcomes among patients treated with an ultrathin strut (60 µm) bioresorbable polymer sirolimus-eluting stent (BP SES) and a thin strut (81 µm) durable polymer everolimus-eluting stent (DP EES) in a large randomized trial. METHODS: BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects with Up to Three De Novo or Restenotic Coronary Artery Lesions V) was an international randomized trial comparing coronary revascularization with BP SES and DP EES regarding the primary endpoint of 12-month target lesion failure (TLF). Analysis of pre-specified 2-year clinical outcomes was performed. RESULTS: Among 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 2-year TLF rate was 7.5% for BP SES and 11.9% for DP EES (-4.33% treatment difference; 95% confidence interval: -8.16% to -0.91%; p = 0.015), driven by differences in target vessel myocardial infarction (MI) (5.3% vs. 9.5%; p = 0.01) and ischemia-driven target lesion revascularization (2.6% vs. 4.9%; p = 0.04). Rates of cardiac death or MI were 7.0% versus 10.4% for BP SES and DP EES, respectively (p = 0.047). Late/very late definite stent thrombosis was statistically lower for BP SES compared with DP EES (0.1% vs. 1.0%; p = 0.045). CONCLUSIONS: In a large randomized trial, significant differences in both TLF and target vessel-related MI persisted through 2 years, favoring treatment with BP SES over DP EES. Significantly lower cumulative target lesion revascularization and late/very late stent thrombosis were also observed with BP SES. (Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions [BIOFLOW-V]; NCT02389946).


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Polímeros/administración & dosificación , Sirolimus/administración & dosificación , Implantes Absorbibles/tendencias , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Stents Liberadores de Fármacos/tendencias , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/administración & dosificación , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Método Simple Ciego
15.
Circ Cardiovasc Interv ; 11(10): e007331, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30354631

RESUMEN

BACKGROUND: Presentation with acute coronary syndromes (ACS) constitutes a high-risk subset of patients with worse outcome after percutaneous coronary intervention. We report clinical outcomes in subjects with ACS from the BIOFLOW V trial (BIOTRONIK - A Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects With up to Three De Novo or Restenotic Coronary Artery Lesions) comparing an ultrathin strut (60 µm) bioresorbable polymer sirolimus-eluting stent (BP-SES) with a thin strut (81 µm) durable polymer everolimus-eluting stent (DP-EES). METHODS AND RESULTS: Among 1334 patients randomized to 2:1 treatment with either BP-SES or DP-EES, 677 (50.7%) ACS patients without ST-segment-elevation myocardial infarction (MI; 454 BP-SES and 223 DP-EES) were identified in the retrospective post hoc analysis. The primary end point of 12-month target lesion failure, individual component end points, and stent thrombosis were evaluated. Recurrent MI was defined as a ≥50% increase of creatine kinase-myocardial band or in the absence of creatine kinase-myocardial band, troponin >50% increase over previous level and >3× the upper limit of normal). All events were adjudicated by a blinded independent clinical events committee. Overall, baseline clinical, angiographic, and procedural characteristics of the ACS population were similar between the 2 treatment groups. At 12 months, target lesion failure occurred in 5.6% (24/426) of BP-SES patients versus 11.0% (23/209) in DP-EES patients ( P=0.02); target lesion failure composite components were cardiac death, 0% versus 1.0% ( P=0.11); target vessel-related MI, 3.5% versus 9.7% ( P=0.003); and clinically driven target lesion revascularization, 2.8% versus 3.4% ( P=0.80). Spontaneous target vessel MI was 0.5% (2/425) for BP-SES versus 2.4% (5/206) for DP-EES ( P=0.041). Stent thrombosis rates at 1 year were similar (0.5% versus 1.0%; P=0.601). CONCLUSIONS: In the ACS subgroup population of the BIOFLOW V study, treatment with BP-SES compared with DP-EES was associated with a significantly lower rate of 12-month target lesion failure, a difference driven by significantly lower periprocedural MI and spontaneous MI. These findings support treatment with an ultrathin strut BP-SES in ACS patients undergoing percutaneous coronary intervention. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02389946.


Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/terapia , Fármacos Cardiovasculares/administración & dosificación , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/administración & dosificación , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Fármacos Cardiovasculares/efectos adversos , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Método Simple Ciego , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
16.
Am Heart J ; 153(5): 843-9, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17452163

RESUMEN

BACKGROUND: Variable results of cardiac resynchronization therapy (CRT) on diastolic function have been described. We investigated 3 and 12 months' effect of CRT on diastolic function and left ventricular (LV) filling pressures and their relation to LV reverse remodeling. METHODS: Fifty-two patients' (36 male, 69 +/- 8 years, QRS duration 170 +/- 29 milliseconds) echo-Doppler was performed before and 3 and 12 months after CRT. Tissue Doppler early diastolic annular (Em) and color M-mode-derived flow propagation (Vp) velocities were used to estimate LV filling pressures by E/Em and E/Vp ratios. RESULTS: After 12 months, LV reverse remodeling (end-systolic volume decrease >15%) was observed in 58%. Despite a significantly more compromised baseline diastolic function of patients without LV reverse remodeling, multivariate analysis revealed that only LV dyssynchrony could predict LV reverse remodeling. Grades 2 and 3 diastolic function improved only in LV reverse remodeling patients (from 34% to 13% to 10%), whereas a nonsignificant increase from 59% to 67% to 72% was observed in patients without reverse remodeling. Irrespective of LV volume response, short-term symptomatic benefit was related to decreased filling pressure. However, after 12 months, E/Em and E/Vp only significantly decreased in patients with LV reverse remodeling (from 16.0 +/- 6 to 10.4 +/- 4 and 2.2 +/- 0.6 to 1.5 +/- 0.4, respectively). CONCLUSIONS: Left ventricular reverse remodeling induced by CRT is accompanied by improvement in diastolic function and estimated LV filling pressure. Short-term symptomatic benefit was related to decreased filling pressure. However, for longer-term symptomatic improvement and decreased filling pressures, LV reverse remodeling appeared mandatory.


Asunto(s)
Estimulación Cardíaca Artificial , Cardiomiopatías/fisiopatología , Cardiomiopatías/terapia , Diástole , Presión Ventricular , Anciano , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Resultado del Tratamiento , Ultrasonografía , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia , Remodelación Ventricular
17.
JACC Cardiovasc Interv ; 10(2): 133-143, 2017 01 23.
Artículo en Inglés | MEDLINE | ID: mdl-28104206

RESUMEN

OBJECTIVES: The aim of this study was to investigate the efficacy and safety of the hybrid ultrathin-strut sirolimus-eluting stent (SES) with biodegradable polymer compared with the thin-strut everolimus-eluting stent (EES) with durable polymer in successfully recanalized chronic total occlusions (CTOs). BACKGROUND: The introduction of drug-eluting stents revolutionized the treatment of CTOs. However, limited data are available on new-generation drug-eluting stents with biodegradable polymer in CTOs. METHODS: In this multicenter trial, patients were randomized, after successful CTO recanalization, to either SES or EES. The primary noninferiority endpoint was in-segment late lumen loss (noninferiority margin 0.2 mm). Secondary endpoints included in-stent late lumen loss and clinical endpoints. RESULTS: Overall, 330 patients were included. At 9 months, angiography was available in 281 patients (85%). Duration of occlusion ≥3 months was 92.5%, with mean stent length of 52.4 ± 28.1 mm versus 52.3 ± 26.5 mm in the SES and EES groups. The primary noninferiority endpoint, in-segment late lumen loss, was not met for SES versus EES (0.13 ± 0.63 mm vs. 0.02 ± 0.47 mm; p = 0.08, 2-sided; difference 0.11 mm; 95% confidence interval: -0.01 to 0.25 mm; pnoninferiority = 0.11, 1-sided). In-stent late lumen loss was comparable between SES and EES (0.12 ± 0.59 mm vs. 0.07 ± 0.46 mm; p = 0.52). The incidence of in-stent and in-segment binary restenosis was significantly higher with SES compared with EES (8.0% vs. 2.1%; p = 0.028), with comparable rates of reocclusions (2.2% vs. 1.4%; p = 0.68). Clinically indicated target lesion and target vessel revascularization (9.2% vs. 4.0% [p = 0.08] and 9.2% vs. 6.0% [p = 0.33]), target vessel failure (9.9% vs. 6.6%; p = 0.35), and definite or probable stent thrombosis (0.7% vs. 0.7%; p = 1.00) were comparable between the SES and EES groups. CONCLUSIONS: This randomized trial failed to show noninferiority of hybrid SES relative to EES in terms of in-segment late lumen loss in successfully recanalized CTOs. Furthermore, a statistically significantly higher rate of binary restenosis was found with SES.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Angiografía Coronaria , Oclusión Coronaria/terapia , Reestenosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/administración & dosificación , Anciano , Bélgica , Fármacos Cardiovasculares/efectos adversos , Enfermedad Crónica , Oclusión Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Trombosis Coronaria/etiología , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Método Simple Ciego , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
18.
Cardiovasc Revasc Med ; 23: 20-21, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33257253

Asunto(s)
Médicos , Humanos
19.
Cardiovasc Revasc Med ; 29: 7-8, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34172401
20.
EuroIntervention ; 10(11): 1272-5, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25136884

RESUMEN

AIMS: Sirolimus-eluting stents (SES) have been shown to be superior to Endeavor zotarolimus-eluting stents (ZES) and comparable to Resolute ZES at eight-month angiography in patients treated for total coronary occlusions (TCO). This study investigated clinical outcome at three-year follow-up. METHODS AND RESULTS: The PRISON III trial investigated the efficacy and safety of SES against ZES (Endeavor and Resolute) in two study phases. In the first phase, 51 patients were randomised to receive SES and 46 to Endeavor ZES. In the second phase, 103 and 104 patients were randomised to SES or Resolute ZES, respectively. Between one and three years there were only a few additional clinical events in all groups. As a result, the rates of target lesion revascularisation 12.2% vs. 19.6%, p=0.49, target vessel failure 14.3% vs. 19.6%, p=0.68, and definite or probable stent thrombosis 4.1% vs. 2.2% were comparable between SES and Endeavor ZES at three years. In the second study phase, the rates of target lesion revascularisation 10% vs. 5.9%, p=0.42, target vessel failure 10% vs. 7.9%, p=0.79 and definite or probable stent thrombosis 1.0% vs. 0% were similar between SES and Resolute ZES. CONCLUSIONS: The present study demonstrated a low incidence of clinical events between one- and three-year follow-up with either SES compared to Endeavor ZES or SES versus Resolute ZES in patients treated for total coronary occlusions.


Asunto(s)
Antibióticos Antineoplásicos/uso terapéutico , Oclusión Coronaria/cirugía , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Sirolimus/uso terapéutico , Anciano , Enfermedades Cardiovasculares/mortalidad , Oclusión Coronaria/tratamiento farmacológico , Reestenosis Coronaria/epidemiología , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Revascularización Miocárdica/estadística & datos numéricos , Intervención Coronaria Percutánea/instrumentación , Reoperación , Trombosis/epidemiología
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda