Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Vasc Interv Radiol ; 31(11): 1874-1885, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33129433

RESUMEN

PURPOSE: To assess the feasibility of inducing vascular occlusion by application of radiofrequency (RF) energy via conductive endovascular wires or baskets. MATERIALS AND METHODS: A retrievable nitinol basket and stainless steel guidewire with a platinum tip were evaluated as conductors for endovascular application of RF energy. Tissue-mimicking thermochromic gel phantoms that change color with heating were cast with 2-, 5-, and 7-mm-diameter lumens and filled with 37 oC saline. After ablation, the phantoms were sectioned, and the thermal footprints were evaluated. Six castrated male domestic swine underwent endovascular ablation using the basket in iliac arteries and guidewires in renal arteries. Post-procedural angiography was performed, and postmortem arterial segments were resected for histopathologic analysis. RESULTS: In the phantom, the depth of thermal change in the 5- and 7-mm lumens averaged 6.3 and 6.0 mm along the basket, respectively, and in the 2- and 5-mm lumens, the depth of thermal change averaged 1.9 and 0.5 mm along the wire, respectively. In the swine, RF energy delivery led to angiographic occlusion at 12 of 13 sites. Thermal injury and occlusion were similar at the proximal, middle, and distal basket treatment zone, whereas injury and occlusion decreased from the proximal to the distal end of the 5-cm wire treatment zone. CONCLUSIONS: Endovascular delivery of RF energy via a conductive basket in medium-sized arteries or a guidewire in small arteries led to acute angiographic and histologic occlusion. The potential to induce stasis might be useful in settings where rapid occlusion is desirable.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Ablación por Radiofrecuencia/instrumentación , Arteria Renal/cirugía , Aleaciones , Animales , Conductividad Eléctrica , Diseño de Equipo , Estudios de Factibilidad , Calor , Arteria Ilíaca/patología , Masculino , Ensayo de Materiales , Modelos Animales , Orquiectomía , Platino (Metal) , Arteria Renal/patología , Acero Inoxidable , Sus scrofa
2.
Radiology ; 289(2): 396-404, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30106347

RESUMEN

Purpose To correlate bead location and attenuation on CT images with the quantity and distribution of drug delivered to the liver following transarterial chemoembolization (TACE) with radiopaque drug-eluting beads (DEB) in a rabbit tumor model. Materials and Methods All procedures were performed with a protocol approved by the Institutional Animal Care and Use Committee. TACE was performed in rabbits (n = 4) bearing VX2 liver tumors by using radiopaque DEB (70-150 µm) loaded with doxorubicin (DOX). Livers were resected 1 hour after embolization, immediately frozen, and cut by using liver-specific three-dimensional-printed molds for colocalization of liver specimens and CT imaging. DOX penetration into tissue surrounding beads was evaluated with fluorescence microscopy. DOX levels in liver specimens were predicted by using statistical models correlating DOX content measured in tissue with bead volume and attenuation measured on CT images. Model predictions were then compared with actual measured DOX concentrations to assess the models' predictive power. Results Eluted DOX remained in close proximity (<600 µm) to beads in the liver 1 hour after TACE. Bead volume and attenuation measured on CT images demonstrated positive linear correlations (0.950 and 0.965, respectively) with DOX content in liver specimens. DOX content model predictions based on CT images were accurate compared with actual liver DOX levels at 1 hour. Conclusion CT may be used to estimate drug dose delivery and distribution in the liver following transarterial chemoembolization (TACE) with doxorubicin-loaded radiopaque drug-eluting beads (DEB). Although speculative, this informational map might be helpful in planning and understanding the spatial effects of TACE with DEB. © RSNA, 2018.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Quimioembolización Terapéutica/métodos , Doxorrubicina/administración & dosificación , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Tomografía Computarizada por Rayos X/métodos , Animales , Modelos Animales de Enfermedad , Sistemas de Liberación de Medicamentos , Hígado/diagnóstico por imagen , Microesferas , Conejos
3.
J Vasc Interv Radiol ; 24(11): 1723-9, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24041915

RESUMEN

PURPOSE: To evaluate and compare the rates of complications on follow-up computed tomography (CT) studies of patients with Celect, Günther Tulip, and Greenfield inferior vena cava (IVC) filters. MATERIALS AND METHODS: Retrospective review of CT studies obtained 0-1,987 days after infrarenal placement of an IVC filter identified 255 Celect, 160 Tulip, and 50 Greenfield filters. Follow-up CT studies were independently evaluated by two observers for IVC perforation, contact with adjacent organs, and filter fracture. Multivariate analysis was performed to identify factors associated with higher rates of IVC perforation, including age, IVC diameter, sex, and history of malignancy. RESULTS: IVC perforation was observed in 126 of 255 Celect filters (49%) with a mean follow-up of 277 days, 69 of 160 Tulip filters (43%) with a mean follow-up of 437 days, and one of 50 Greenfield filters (2%) with a mean follow-up of 286 days. A significantly higher IVC perforation rate was observed in women (45.5%) compared with men (30.8%; P = .002) and in patients with a history of malignancy (43.7%) compared with patients with no history of malignancy (29.9%; P < .001). Filter fracture was rare, observed in two of 255 Celect filters (0.8%), one of 160 Tulip filters (0.6%), and none of 50 Greenfield filters. CONCLUSIONS: No significant difference was observed in IVC perforation rate between Celect and Tulip filters. Greenfield filters had a significantly lower rate of IVC perforation than Celect and Tulip filters. Higher IVC perforation rates were observed in women and patients with a history of malignancy.


Asunto(s)
Falla de Prótesis , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Lesiones del Sistema Vascular/etiología , Filtros de Vena Cava , Vena Cava Inferior/lesiones , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Femenino , Humanos , Incidencia , Modelos Lineales , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Variaciones Dependientes del Observador , Ohio , Flebografía/métodos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X , Lesiones del Sistema Vascular/diagnóstico por imagen , Vena Cava Inferior/diagnóstico por imagen , Adulto Joven
4.
Cancer Med ; 10(7): 2259-2267, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33687146

RESUMEN

BACKGROUND: To evaluate outcomes and survival rates in patients with metastatic adrenocortical carcinoma (ACC) who were treated with image-guided locoregional treatments (IGLTs). PURPOSE: To evaluate the overall survival (OS) and clinical impact of IGLT in the management of patients with advanced metastatic ACC. METHODS: Retrospective review of 39 patients treated with IGLT between 1999 and 2018 was performed. Short- and long-term efficacy of treatments were defined based upon imaging and clinical data. Subgroup survival analysis was performed on patients with metastatic disease at diagnosis (N = 17) and compared with the same stage group from the most recent National Cancer Database (NCDB) report. Statistical analysis was performed using Cox proportional hazards model. RESULTS: Treatments were performed at different anatomic sites including liver (N = 46), lung (N = 14), retroperitoneum (N = 5), bone (N = 4), subcutaneous (N = 2), and intracaval (N = 1). Radiofrequency, microwave, cryoablation, or a combination of two modalities (45, 18, 3, 3, respectively) were used in 69 ablation sessions. Intra-arterial procedures were performed in 12 patients in 18 treatment cycles (range 1-3 per patient). As of a 2019 analysis, 11 patients were alive with a mean follow-up of 169 months (range 63-292 months) from diagnosis. Two- and 5-year OS rates for all patients were 84.5% and 51%, respectively, and 76.5% and 59% for patients with metastatic disease at diagnosis (N = 17). This compares favorably with an NCDB report of 35% 5-year survival rate for patients with metastatic disease. Female gender and longer time from diagnosis to first IGLT were found to be predictors of prolonged survival with hazard ratios of 0.23 (p < 0.001) and 0.66 (p = 0.001), respectively. CONCLUSION: IGLT may be associated with prolonged life expectancy in select patients with metastatic ACC.


Asunto(s)
Neoplasias de la Corteza Suprarrenal/cirugía , Carcinoma Corticosuprarrenal/cirugía , Criocirugía/métodos , Embolización Terapéutica/métodos , Neoplasias de la Corteza Suprarrenal/diagnóstico por imagen , Neoplasias de la Corteza Suprarrenal/patología , Carcinoma Corticosuprarrenal/diagnóstico por imagen , Carcinoma Corticosuprarrenal/patología , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Ablación por Radiofrecuencia/métodos , Estudios Retrospectivos , Cirugía Asistida por Computador/métodos , Tasa de Supervivencia , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento , Adulto Joven
5.
Cardiovasc Intervent Radiol ; 44(5): 774-781, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33409547

RESUMEN

PURPOSE: To compare needle placement performance using an augmented reality (AR) navigation platform implemented on smartphone or smartglasses devices to that of CBCT-guided fluoroscopy in a phantom. MATERIALS AND METHODS: An AR application was developed to display a planned percutaneous needle trajectory on the smartphone (iPhone7) and smartglasses (HoloLens1) devices in real time. Two AR-guided needle placement systems and CBCT-guided fluoroscopy with navigation software (XperGuide, Philips) were compared using an anthropomorphic phantom (CIRS, Norfolk, VA). Six interventional radiologists each performed 18 independent needle placements using smartphone (n = 6), smartglasses (n = 6), and XperGuide (n = 6) guidance. Placement error was defined as the distance from the needle tip to the target center. Placement time was recorded. For XperGuide, dose-area product (DAP, mGy*cm2) and fluoroscopy time (sec) were recorded. Statistical comparisons were made using a two-way repeated measures ANOVA. RESULTS: The placement error using the smartphone, smartglasses, or XperGuide was similar (3.98 ± 1.68 mm, 5.18 ± 3.84 mm, 4.13 ± 2.38 mm, respectively, p = 0.11). Compared to CBCT-guided fluoroscopy, the smartphone and smartglasses reduced placement time by 38% (p = 0.02) and 55% (p = 0.001), respectively. The DAP for insertion using XperGuide was 3086 ± 2920 mGy*cm2, and no intra-procedural radiation was required for augmented reality. CONCLUSIONS: Smartphone- and smartglasses-based augmented reality reduced needle placement time and radiation exposure while maintaining placement accuracy compared to a clinically validated needle navigation platform.


Asunto(s)
Fluoroscopía/métodos , Imagenología Tridimensional/métodos , Fantasmas de Imagen , Gafas Inteligentes , Teléfono Inteligente , Tomografía Computarizada de Haz Cónico Espiral/métodos , Cirugía Asistida por Computador/métodos , Realidad Aumentada , Humanos
6.
Cardiovasc Intervent Radiol ; 43(12): 1918-1924, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32803282

RESUMEN

PURPOSE: Topotecan is a camptothecin analogue with potential advantages over irinotecan for transarterial chemoembolization (TACE) of hepatic colorectal metastases including greater anti-neoplastic activity without enzymatic activation. The purpose of this study was to assess safety and tolerability of topotecan-loaded radiopaque microspheres (ROMTOP) administered by TACE in a rabbit model and to compare the in vitro elution of topotecan from microspheres to irinotecan. MATERIALS AND METHODS: Topotecan was loaded into radiopaque microspheres (70-150 µm, DC Bead LUMI™, Biocompatibles UK Ltd-Boston Scientific Corporation) to the maximum capacity of 80 mg/mL of microspheres. Six healthy New Zealand White rabbits underwent hepatic TACE with ROMTOP under fluoroscopic guidance until angiographic stasis. Assessment of toxicities included regular liver function tests and complete blood counts until euthanasia 28 days post-TACE. In vitro topotecan elution from the microspheres was assessed using an open-loop flow-through system and compared to irinotecan. RESULTS: The mean bead volume and topotecan dose delivered were 0.086 mL (0.076-0.105 mL) and 1.99 mg/kg (1.51-2.55 mg/kg), respectively. Aspartate aminotransferase and alanine aminotransferase were elevated post-embolization but resolved within 2 weeks. One rabbit died two days after TACE with pyloric duodenal perforation observed at necropsy, potentially due to non-target embolization. In vitro elution of topotecan from ROMTOP was complete in 10 h compared to 3 h for irinotecan-loaded microspheres. CONCLUSION: Selective embolization with ROMTOP was tolerated at a dose of 2 mg/kg (24 mg/m2) in rabbits. In vitro topotecan elution from microspheres was more prolonged compared to irinotecan.


Asunto(s)
Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Neoplasias Hepáticas Experimentales/terapia , Topotecan/farmacología , Animales , Carcinoma Hepatocelular/diagnóstico , Humanos , Irinotecán , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas Experimentales/diagnóstico , Microesferas , Conejos , Inhibidores de Topoisomerasa I/farmacología
7.
JAMA Oncol ; 6(1): 133-141, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31750870

RESUMEN

PURPOSE: To harmonize the eligibility criteria and radiologic disease assessment definitions in clinical trials of adjuvant therapy for renal cell carcinoma (RCC). METHOD: On November 28, 2017, US-based experts in RCC clinical trials, including medical oncologists, urologic oncologists, regulators, biostatisticians, radiologists, and patient advocates, convened at a public workshop to discuss eligibility for trial entry and radiologic criteria for assessing disease recurrence in adjuvant trials in RCC. Multiple virtual meetings were conducted to address the issues identified at the workshop. RESULTS: The key workshop conclusions for adjuvant RCC therapy clinical trials were as follows. First, patients with non-clear cell RCC could be routinely included, preferably in an independent cohort. Second, patients with T3-4, N+M0, and microscopic R1 RCC tumors may gain the greatest advantages from adjuvant therapy. Third, trials of agents not excreted by the kidney should not exclude patients with severe renal insufficiency. Fourth, therapy can begin 4 to 16 weeks after the surgical procedure. Fifth, patients undergoing radical or partial nephrectomy should be equally eligible. Sixth, patients with microscopically positive soft tissue or vascular margins without gross residual or radiologic disease may be included in trials. Seventh, all suspicious regional lymph nodes should be fully resected. Eighth, computed tomography should be performed within 4 weeks before trial enrollment; for patients with renal insufficiency who cannot undergo computed tomography with contrast, noncontrast chest computed tomography and magnetic resonance imaging of the abdomen and pelvis with gadolinium should be performed. Ninth, when feasible, biopsy should be undertaken to identify any malignant disease. Tenth, when biopsy is not feasible, a uniform approach should be used to evaluate indeterminate radiologic findings to identify what constitutes no evidence of disease at trial entry and what constitutes radiologic evidence of disease. Eleventh, a uniform approach for establishing the date of recurrence should be included in any trial design. Twelfth, patient perspectives on the use of placebo, conditions for unblinding, and research biopsies should be considered carefully during the conduct of an adjuvant trial. CONCLUSIONS AND RELEVANCE: The discussions suggested that a uniform approach to eligibility criteria and radiologic disease assessment will lead to more consistently interpretable trial results in the adjuvant RCC therapy setting.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/tratamiento farmacológico , Carcinoma de Células Renales/patología , Ensayos Clínicos como Asunto , Humanos , Neoplasias Renales/tratamiento farmacológico , Neoplasias Renales/terapia , Márgenes de Escisión , Recurrencia Local de Neoplasia/cirugía , Nefrectomía
8.
JAMA Oncol ; 5(12): 1790-1798, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31670753

RESUMEN

Objective: To harmonize eligibility criteria and radiographic disease assessments in clinical trials of adjuvant therapy for muscle-invasive bladder cancer (MIBC). Methods: National experts in bladder cancer clinical trial research, including medical and urologic oncologists, radiologists, biostatisticians, and patient advocates, convened at a public workshop on November 28, 2017, to discuss eligibility, radiographic entry criteria, and assessment of disease recurrence in adjuvant clinical trials in patients with MIBC. Results: The key workshop conclusions for adjuvant MIBC clinical trials included the following points: (1) patients with urothelial carcinoma with divergent histologic differentiation should be allowed to enroll; (2) neoadjuvant chemotherapy is defined as at least 3 cycles of neoadjuvant cisplatin-based combination chemotherapy; (3) patients with muscle-invasive, upper-tract urothelial carcinoma should be included in adjuvant trials of MIBC; (4) patients with severe renal insufficiency can enroll into trials using agents that are not renally excreted; (5) patients with microscopic surgical margins can be included; (6) patients should undergo a standard bilateral lymph node dissection prior to enrollment; (7) computed tomographic (CT) imaging should be performed within 4 weeks prior to enrollment. For patients with renal insufficiency who cannot undergo CT imaging with contrast, noncontrast chest CT and magnetic resonance imaging of the abdomen and pelvis with gadolinium should be done; (8) biopsy of indeterminate lesions to evaluate for malignant disease should be done when feasible; (9) a uniform approach to evaluate indeterminate radiographic lesions when biopsy is not feasible should be included in any trial design; (10) a uniform approach to determining the date of recurrence is important in interpreting adjuvant trial results; and (11) new high-grade, upper-tract primary tumors and new MIBC tumors should be considered recurrence events. Conclusions and Relevance: A uniform approach to eligibility criteria, definitions of no evidence of disease, and definitions of disease recurrence may lead to more consistent interpretations of adjuvant trial results in MIBC.


Asunto(s)
Carcinoma de Células Transicionales/terapia , Cisplatino/uso terapéutico , Ensayos Clínicos como Asunto/normas , Selección de Paciente , Neoplasias de la Vejiga Urinaria/terapia , Carcinoma de Células Transicionales/diagnóstico por imagen , Conferencias de Consenso como Asunto , Humanos , Escisión del Ganglio Linfático , Imagen por Resonancia Magnética , Márgenes de Escisión , Terapia Neoadyuvante , Defensa del Paciente , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen
9.
Ann Biomed Eng ; 46(3): 452-463, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29305735

RESUMEN

As a low-cost needle navigation system, AngleNav may be used to improve the accuracy, speed, and ease of CT-guided needle punctures. The AngleNav hardware includes a wireless device with a microelectromechanical (MEMS) tracker that can be attached to any standard needle. The physician defines the target, desired needle path and skin entry point on a CT slice image. The accuracy of AngleNav was first tested in a 3D-printed calibration platform in a benchtop setting. An abdominal phantom study was then performed in a CT scanner to validate the accuracy of the device's angular measurement. Finally, an in vivo swine study was performed to guide the needle towards liver targets (n = 8). CT scans of the targets were used to quantify the angular errors and needle tip-to-targeting distance errors between the planned needle path and the final needle position. The MEMS tracker showed a mean angular error of 0.01° with a standard deviation (SD) of 0.62° in the benchtop setting. The abdominal phantom test showed a mean angular error of 0.87° with an SD of 1.19° and a mean tip-to-target distance error of 4.89 mm with an SD of 1.57 mm. The animal experiment resulted in a mean angular error of 6.6° with an SD of 1.9° and a mean tip-to-target distance error of 8.7 mm with an SD of 3.1 mm. These results demonstrated the feasibility of AngleNav for CT-guided interventional workflow. The angular and distance errors were reduced by 64.4 and 54.8% respectively if using AngleNav instead of freehand insertion, with a limited number of operators. AngleNav assisted the physicians to deliver accurate needle insertion during CT-guided intervention. The device could potentially reduce the learning curve for physicians to perform CT-guided needle targeting.


Asunto(s)
Agujas , Tomografía Computarizada por Rayos X , Animales , Humanos , Biopsia Guiada por Imagen/instrumentación , Biopsia Guiada por Imagen/métodos , Porcinos
10.
Cardiovasc Intervent Radiol ; 39(8): 1177-86, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27206503

RESUMEN

PURPOSE: To describe first clinical experience with a directly image-able, inherently radio-opaque microspherical embolic agent for transarterial embolization of liver tumors. METHODOLOGY: LC Bead LUMI™ is a new product based upon sulfonate-modified polyvinyl alcohol hydrogel microbeads with covalently bound iodine (~260 mg I/ml). 70-150 µ LC Bead LUMI™ iodinated microbeads were injected selectively via a 2.8 Fr microcatheter to near complete flow stasis into hepatic arteries in three patients with hepatocellular carcinoma, carcinoid, or neuroendocrine tumor. A custom imaging platform tuned for LC LUMI™ microbead conspicuity using a cone beam CT (CBCT)/angiographic C-arm system (Allura Clarity FD20, Philips) was used along with CBCT embolization treatment planning software (EmboGuide, Philips). RESULTS: LC Bead LUMI™ image-able microbeads were easily delivered and monitored during the procedure using fluoroscopy, single-shot radiography (SSD), digital subtraction angiography (DSA), dual-phase enhanced and unenhanced CBCT, and unenhanced conventional CT obtained 48 h after the procedure. Intra-procedural imaging demonstrated tumor at risk for potential under-treatment, defined as paucity of image-able microbeads within a portion of the tumor which was confirmed at 48 h CT imaging. Fusion of pre- and post-embolization CBCT identified vessels without beads that corresponded to enhancing tumor tissue in the same location on follow-up imaging (48 h post). CONCLUSION: LC Bead LUMI™ image-able microbeads provide real-time feedback and geographic localization of treatment in real time during treatment. The distribution and density of image-able beads within a tumor need further evaluation as an additional endpoint for embolization.


Asunto(s)
Carcinoma Hepatocelular/terapia , Embolización Terapéutica/métodos , Neoplasias Hepáticas/terapia , Resinas Acrílicas/uso terapéutico , Anciano de 80 o más Años , Angiografía de Substracción Digital , Carcinoma Hepatocelular/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Fluoroscopía , Humanos , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Microesferas , Persona de Mediana Edad , Alcohol Polivinílico/uso terapéutico , Resultado del Tratamiento
11.
Tech Vasc Interv Radiol ; 18(2): 100-12, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26070622

RESUMEN

Vascular closure devices (VCDs) are used to obtain hemostasis at the vascular access site while limiting the need for manual compression. They have gained significant popularity since their introduction in the mid-1990s. In the past 20 years, there has been a multitude of different devices introduced with various mechanisms of action. Manual compression remains the gold standard but can be very time consuming and painful for the patient. VCDs are advantageous in that they can reduce time to hemostasis and patient recovery and improve patient comfort. However, a large number of catheter-based procedures are performed without these closure devices owing to lack of operator familiarity, risk of complications, and cost. Most VCDs are approved for arteriotomies between 5 and 8F, with 1 device approved for up to 21F. Major complications include infection and limb ischemia. This article provides an update on currently approved VCDs, a brief overview of the literature, and our institutional experience with these devices.


Asunto(s)
Arteriopatías Oclusivas/etiología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Infección de la Herida Quirúrgica/etiología , Dispositivos de Acceso Vascular/efectos adversos , Dispositivos de Cierre Vascular/efectos adversos , Arteriopatías Oclusivas/diagnóstico , Arteriopatías Oclusivas/prevención & control , Diseño de Equipo , Técnicas Hemostáticas/efectos adversos , Técnicas Hemostáticas/instrumentación , Humanos , Infección de la Herida Quirúrgica/diagnóstico , Infección de la Herida Quirúrgica/prevención & control
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda