J Sep Sci ; 38(12): 2033-7, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25845351

RESUMEN

A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono-hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R(2) > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co-existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.


Asunto(s)
Análisis Químico de la Sangre/métodos , Lípidos/sangre , Ceramidas/química , Cerebrósidos/química , Cromatografía Liquida , Humanos , Lípidos/química , Lisofosfatidilcolinas/química , Metaboloma , Fosfatidilcolinas/química , Plasma/química , Reproducibilidad de los Resultados , Dióxido de Silicio , Espectrometría de Masa por Ionización de Electrospray , Esfingomielinas/química , Espectrometría de Masas en Tándem
2.
J Sep Sci ; 34(13): 1590-8, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21595025

RESUMEN

A highly sensitive simultaneous quantitative method for a cassette cold-microdosing study on celiprolol and atenolol was developed with liquid chromatography-tandem mass spectrometry. The method utilizes a combination of solid-phase extraction (SPE) with strong cation exchange (SCX) cartridge columns and reversed-phase chromatography with an ODS analytical column. SCX-SPE cartridge columns (100 mg sorbent) were used for a selective extraction of celiprolol, atenolol and metoprolol (internal standard) from 500 µL of human plasma samples. Turbo-ion spray at positive mode was employed for the ionization of the drug compounds. Quantitation was performed on a triple quadrupole mass spectrometer by selected reaction monitoring with the transitions of m/z 380 to m/z 251 for celiprolol and m/z 267 to m/z 145 for atenolol. Separation of analytes was achieved on an ODS column (100 mm length × 2.1 mm id, 3 µm) by a gradient elution with 10 mM formic acid and methanol by varying their proportion at a flow rate of 0.2 mL/min. The method was validated in the range of 1-250 pg/mL for celiprolol and 2.5-250 pg/mL for atenolol and was successfully applied to the elucidation of pharmacokinetic profiling in a cold cassette microdosing study of the ß-blockers.


Asunto(s)
Atenolol/sangre , Celiprolol/sangre , Cromatografía Líquida de Alta Presión/métodos , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Antihipertensivos/sangre , Antihipertensivos/aislamiento & purificación , Atenolol/aislamiento & purificación , Celiprolol/aislamiento & purificación , Humanos , Sensibilidad y Especificidad
4.
J Sep Sci ; 28(14): 1823-30, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16224979

RESUMEN

A severe peak tailing was observed for adenosine 5'-monophosphate in flow injection analysis with stainless steel tubing and water/methanol mixture (1:1, v/v) as carrier. The cause of the peak tailing was investigated by focusing on the chemical structure of the analytes, the material used for the analytical systems and the composition of the carrier. We clarified that the peak tailing was caused by the interaction between phosphate residues in the analytes and stainless steel. The severe peak tailing did not occur with stainless steel tubing when the phosphate compounds were analyzed with carrier containing phosphoric acid or phosphate buffer. The findings indicate that such ill peak profiles are usually not considerable in conventional HPLC separation because phosphoric acid or phosphate buffer is quite commonly used in eluents. In LC-MS, however, the use of phosphoric acid and phosphate buffer is usually avoided because of their non-volatility; therefore this interaction between stainless steel and phosphate compound becomes predominant and results in severe peak tailings. We also found an effective method for avoiding the interaction. When stainless parts, such as LC tubing and ESI spray capillary, were treated with phosphoric acid prior to analysis, the peak profiles of the phosphate compounds were dramatically improved, even when non-phosphate buffer is used as carrier.


Asunto(s)
Fosfatos/análisis , Acero Inoxidable/química , Cromatografía Liquida/métodos , Espectrometría de Masa por Ionización de Electrospray