Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Rapid Commun Mass Spectrom ; 33(24): 1906-1914, 2019 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-31323696

RESUMEN

RATIONALE: We developed a new high-throughput method to analyze tegafur (FT) and 5-fluorouracil (5-FU) in tear and plasma samples using hydrophilic interaction liquid chromatography (HILIC)/tandem mass spectrometry (MS/MS). METHODS: The tear samples (10 µL) spiked with FT, 5-FU, and 5-chlorouracil (internal standard) were diluted using 40 µL of 2 M ammonium acetate and 250 µL of acetonitrile with 2% formic acid; 20 µL of plasma spiked with the two drugs and internal standard was diluted with 80 µL of 2 M ammonium acetate and 500 µL of acetonitrile with 2% formic acid. After centrifugation, the clear supernatant extract (15 µL) was directly injected into the HILIC/MS/MS instrument, and each drug was separated on a Unison UK-Amino column (50 mm × 3 mm i.d., 3 µm particle size) with a linear gradient elution system composed of 10 mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.7 mL/min. We performed quantification by multiple reaction monitoring (MRM) with negative-ion atmospheric-pressure chemical ionization. RESULTS: Distinct peaks were observed for the drugs on each MRM channel within 2 min. The regression equations showed good linearity within the range 0.04-4.0 µg/mL for the tear and plasma samples with detection limits at 0.02-0.04 µg/mL. Recoveries for target analytes (FT and 5-FU) for the tear and plasma samples were in the 94-128% and 94-104% ranges, respectively. The intra- and inter-day coefficients of variation for the two drugs were lower than 10.8%. The accuracies of quantitation were 97-115% for both samples. CONCLUSIONS: We established a high-throughput, reproducible, and practical procedure for analyzing FT and 5-FU in human tear and plasma samples using HILIC/MS/MS analysis with an aminopropyl-bonded mixed-mode separation column. This method can be applied to the high-throughput routines used in clinical analyses.


Asunto(s)
Fluorouracilo/análisis , Lágrimas/química , Tegafur/análisis , Anciano , Cromatografía Líquida de Alta Presión , Femenino , Fluorouracilo/sangre , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Límite de Detección , Masculino , Espectrometría de Masas en Tándem , Tegafur/sangre
2.
J Sep Sci ; 35(5-6): 726-33, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22271670

RESUMEN

A novel method is described for the extraction of methamphetamine, amphetamine, and methylenedioxyphenylalkylamine designer drugs, such as 3,4-methylenedioxy-methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxyethylamphetamine, N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine, and 3,4-(methylenedioxyphenyl)-2-butanamine, from human whole blood using molecularly imprinted solid-phase extraction as highly selective sample clean-up technique. Whole blood samples were diluted with 10 mmol/L ammonium acetate (pH 8.6) and applied to a SupelMIP-Amphetamine molecularly imprinted solid-phase extraction cartridge. The cartridge was then washed to eliminate interferences, and the amphetamines of interest were eluted with formic acid/methanol (1:100, v/v). After derivatization with trifluoroacetic anhydride, the analytes were quantified using gas chromatography-mass spectrometry. Recoveries of the seven amphetamines spiked into whole blood were 89.1-102%. The limits of quantification for each compound in 200 µL of whole blood were between 0.25 and 1.0 ng. The maximum intra- and inter-day coefficients of variation were 9.96 and 13.8%, respectively. The results show that methamphetamine, amphetamine, and methylenedioxyphenylalkyl-amine designer drugs can be efficiently extracted from crude biological samples such as whole blood by molecularly imprinted solid-phase extraction with good reproducibility. This extraction method will be useful for the pretreatment of human samples before gas chromatography-mass spectrometry.


Asunto(s)
Anfetamina/aislamiento & purificación , Anfetaminas/aislamiento & purificación , Drogas de Diseño/aislamiento & purificación , Polímeros/química , Extracción en Fase Sólida/métodos , 3,4-Metilenodioxianfetamina/análogos & derivados , 3,4-Metilenodioxianfetamina/sangre , 3,4-Metilenodioxianfetamina/aislamiento & purificación , Adsorción , Anfetamina/sangre , Anfetaminas/sangre , Drogas de Diseño/análisis , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Impresión Molecular , Polímeros/síntesis química , Extracción en Fase Sólida/instrumentación
3.
Anal Bioanal Chem ; 401(7): 2215-23, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21874269

RESUMEN

Dextromethorphan was extracted from human plasma samples (100 µL) using MonoTip C(18) tips, which are packed with C(18)-bonded monolithic silica gel that is attached to the inside of the tip. The samples, which contained dextromethorphan and trimeprazine as an internal standard (IS), were mixed with 200 µL of distilled water and 50 µL of 1 mol/L glycine-sodium hydroxide buffer (pH 10). The mixture was extracted to the C(18) phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C(18) phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.5 µm) gave adequate separation of the dextromethorphan, IS, and impurities. The recoveries of dextromethorphan and the IS spiked into plasma were >87.4%. The regression equation for dextromethorphan showed excellent linearity from 2.5 to 320 ng/mL of plasma, and the limit of detection was 1.25 ng/mL of plasma. The intraday and interday coefficients of variation were less than 10.5% and 14.7%, respectively. The accuracy ranged from 91.9% to 107%. The validated method was successfully used to quantify the plasma concentration of dextromethorphan in a human subject after oral administration of the drug.


Asunto(s)
Dextrometorfano/sangre , Antagonistas de Aminoácidos Excitadores/sangre , Cromatografía de Gases y Espectrometría de Masas , Extracción en Fase Sólida , Administración Oral , Dextrometorfano/administración & dosificación , Antagonistas de Aminoácidos Excitadores/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Estándares de Referencia , Sensibilidad y Especificidad
4.
Eur J Mass Spectrom (Chichester) ; 27(1): 63-70, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33745337

RESUMEN

Aminoglycosides are a class of broad-spectrum antibiotics with several clinical uses. Owing to the ototoxicity and nephrotoxicity of aminoglycosides, therapeutic drug monitoring is required. This study aimed to devise a high-throughput method for identification and quantitative determination of aminoglycoside antibiotics in human plasma samples using ultra-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (UPLC-Q-ToF-MS). Plasma samples (100 µL) spiked with five aminoglycosides (streptomycin, spectinomycin, amikacin, kanamycin, and gentamycin) and an internal standard (ribostamycin) were diluted and centrifuged in aqueous formic acid and acetonitrile. The clear supernatant extract was evaporated and reconstituted in the mobile phase, of which 4 µL was subjected to UPLC-Q-ToF-MS. Prominent peaks were observed for the drugs within 3 min. The recoveries of five aminoglycosides from plasma samples were 92.6-120%. The regression equations showed excellent linearity (0.9999 ≥ r2 ≥ 0.9987) within the range of 1.0-100 µg/mL, and detection limits of 0.5-2.0 µg/mL. The coefficients of the intra- and inter-day variations for five drugs were less than 11.8%, while the accuracy of quantitation was in the range of 89-111%. In this study, a novel method was presented for identification and determination of aminoglycosides in human plasma samples using UPLC-Q-ToF-MS analysis. This method can be applied to high-throughput analysis used for clinical and environmental purposes.


Asunto(s)
Preparaciones Farmacéuticas , Espectrometría de Masas en Tándem , Aminoglicósidos , Antibacterianos , Cromatografía Líquida de Alta Presión , Humanos
5.
Anal Bioanal Chem ; 394(4): 1161-70, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19387622

RESUMEN

This paper describes a fully automated on-line method combining in-tube solid-phase microextraction (SPME) in which sample clean-up and enrichment are conducted through an open tubular fused-silica capillary column and high-performance liquid chromatography (HPLC)/tandem mass spectrometry (MS/MS) detection for the determination of six butyrophenone derivatives (moperone, floropipamide, haloperidol, spiroperidol, bromperidol, and pimozide) in human plasma samples. The six butyrophenones were extracted by repeatedly aspirating and dispensing plasma sample solutions on a DB-17 capillary column (60 cm x 0.32 mm i.d., film thickness 0.25 microm). The analytes retained on the inner surface of the capillary column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. Extraction efficiencies ranged from 12.7% to 31.8% for moperone, spiroperidol, and pimozide, and from 1.08% to 4.86% for floropipamide, haloperidol, and bromperidol. The regression equations for all compounds showed excellent linearity, ranging from 0.05 to 50 ng/0.1 mL of plasma, except for moperone and spiroperidol (0.01 to 50 ng/0.1 mL). The limits of detection and quantification in plasma for each drug were 0.03-0.2 and 0.1-0.5 ng/mL, respectively. The intra- and inter-day coefficients of variation for all compounds in plasma were not greater than 13.7%.


Asunto(s)
Butirofenonas/sangre , Microextracción en Fase Sólida/métodos , Cromatografía Líquida de Alta Presión , Humanos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem , Factores de Tiempo
6.
J Sep Sci ; 31(12): 2265-71, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18546392

RESUMEN

A method for the simultaneous extraction of four tricyclic antidepressants from human plasma samples using pipette tip SPE with MonoTip C(18) tips is presented. Human plasma (0.1 mL) containing four tricyclic antidepressants (amitriptyline, amoxapine, imipramine, and trimipramine) and an internal standard (IS), protriptyline, was mixed with 0.4 mL of distilled water and 100 microL 1 M NaOH solution. After centrifugation of the mixture, the supernatant was extracted to the C(18) phase of the tip by 20 repeated aspirating/dispensing cycles using a manual micropipettor. The analytes retained in the tip were eluted with methanol by five repeated aspirating/dispensing cycles. Without evaporation and reconstitution, the eluate was directly injected into a gas chromatograph injector and detected by a mass spectrometer with SIM in the positive-ion electron impact mode. Recovery of the four antidepressants and IS spiked into human plasma was 80.2-92.1%. The regression equations for the four antidepressants showed excellent linearity in the range of 0.2-40 ng/0.1 mL. LODs and LOQs for the four drugs were 0.05-0.2 ng/0.1 mL and 0.2-0.5 ng/0.1 mL, respectively. Intra- and interday CVs for the four drugs in plasma were no greater than 9.5%.


Asunto(s)
Antidepresivos Tricíclicos/sangre , Cromatografía de Gases y Espectrometría de Masas/métodos , Extracción en Fase Sólida/métodos , Amoxapina/administración & dosificación , Amoxapina/sangre , Antidepresivos Tricíclicos/administración & dosificación , Antidepresivos Tricíclicos/química , Análisis Químico de la Sangre/métodos , Humanos , Masculino , Persona de Mediana Edad , Extracción en Fase Sólida/instrumentación
7.
J AOAC Int ; 91(6): 1354-62, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19202796

RESUMEN

Chlorpromazine, levomepromazine, promazine, triflupromazine, and trimeprazine were simultaneously determined in human whole blood and plasma by combining headspace solid-phase microextraction and gas chromatography with nitrogen-phosphorus detection. Extraction efficiency for the phenothiazine derivatives was 0.013-0.117% for both sample types. Regression equations were linear [correlation coefficient (r) = 0.9951-0.9999] within the range 2.5-200 ng/0.5 mL for triflupromazine and trimeprazine, and 6.3-200 ng/0.5 mL for chlorpromazine, levomepromazine, and promazine. The limit of detection for each compound was 0.2-3.9 ng/0.5 mL whole blood and plasma. Intraday and interday coefficients of variation for all phenothiazines in both human samples were commonly < 15 and 20%, respectively. We also report the determination of levomepromazine in human plasma after oral administration.


Asunto(s)
Antipsicóticos/sangre , Fenotiazinas/sangre , Adulto , Cromatografía de Gases , Femenino , Humanos , Indicadores y Reactivos , Nitrógeno/química , Fósforo/química , Control de Calidad , Estándares de Referencia , Microextracción en Fase Sólida
8.
Leg Med (Tokyo) ; 31: 66-73, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29413992

RESUMEN

A new high-throughput method was developed for analysis of valproate in human plasma samples by QuEChERS extraction and gas chromatography-tandem mass spectrometry (GC-MS/MS). Plasma samples (0.2 ml) spiked with valproate and secobarbital-d5 (internal standard) were diluted with 1.3 ml of distilled water. Acetonitrile (1 ml) was added followed by 0.4 g MgSO4 and 0.1 g NaOAC. After a centrifugation step (2000 g for 10 min), 1 ml of the supernatant was transferred to a dispersive-solid phase extraction (dSPE) tube containing 150 mg MgSO4 and 50 mg C18. This mixture was vortexed and centrifuged at 3000 g for 5 min, and then the upper layer was evaporated to dryness under a stream of nitrogen. The residue was dissolved in 40 µl ethyl acetate, and a 1-µl aliquot was injected into the GC-MS/MS. The GC separation of the compounds was achieved on a fused-silica capillary column Rxi-5Sil MS (30 m × 0.25 mm i.d.; 0.25-µm film thickness) and detected by MS/MS operating in electron ionization ion source mode. The regression equations showed excellent linearity (r > 0.9997) from 50 to 5000 ng/ml for plasma, with limit of detection of 10 ng/ml. The extraction efficiency of valproate for plasma ranged between 71.2%-103.5%. The coefficient of variation was <18.5%. The method was successfully applied to actual analyses of an autopsy case. This method can be useful for simple and reliable measurements of valproate in clinical and toxicological analyses; it can be integrated in screening and simultaneous determination methods for multiple drugs and poisons in the further studies.


Asunto(s)
Anticonvulsivantes/sangre , Cromatografía de Gases y Espectrometría de Masas/métodos , Espectrometría de Masas en Tándem/métodos , Ácido Valproico/sangre , Adulto , Anticonvulsivantes/química , Femenino , Patologia Forense , Humanos , Secobarbital/sangre , Secobarbital/química , Ácido Valproico/química
9.
Leg Med (Tokyo) ; 30: 14-20, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29127845

RESUMEN

A highly sensitive method was developed for the analysis of alendronate in human plasma and dialysate using MonoSpin™ SAX® extraction and metal-free high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) following methylation with trimethylsilyldiazomethane. The chromatographic separation of the derivatives for alendronate and alendronate-d6 was achieved on an L-column2 ODS metal-free column (50 mm  ×  2 mm i.d., particle size 3 µm) with a linear gradient elution system composed of 10 mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.3 ml/min. Quantification was performed by multiple reaction monitoring (MRM) with positive-ion electrospray ionization (ESI). Distinct peaks were observed for alendronate and for the internal standard on each channel within 1 min. The regression equations showed good linearity within the ranges of 2.0-100 ng/0.5 ml for the plasma and 1.0-100 ng/0.5 ml for the dialysate, with the limits of detection at 1.0 ng/0.5 ml for the plasma and 0.5 ng/0.5 ml for the dialysate. Extraction efficiencies for alendronate for the plasma and dialysate were 41.1-51.2% and 63.6-73.4%, respectively. The coefficient of variation (CV) was ≤8.5%. The method was successfully applied to the analyses of real plasma and dialysate samples derived after intravenous administration of alendronate.


Asunto(s)
Alendronato/sangre , Conservadores de la Densidad Ósea/sangre , Cromatografía Líquida de Alta Presión/métodos , Soluciones para Diálisis/análisis , Plasma/química , Espectrometría de Masas en Tándem/métodos , Diazometano/análogos & derivados , Humanos , Metales , Compuestos de Trimetilsililo
10.
Int J Mol Med ; 19(5): 765-70, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17390081

RESUMEN

Pyrroloquinoline quinone (PQQ) has been implicated in certain physiological activities in mammals such as functioning as a potent growth factor in mice, and promoting DNA synthesis in human fibroblasts. These are clearly important physiological functions, however, the molecular mechanisms involved in PQQ activity are not yet fully understood. In order to address this, in this study we analyzed the effects of PQQ on the proliferation of NIH3T3 mouse fibroblasts and on their intracellular signal transduction mechanism. When activated c-Ha-ras-transformed NIH3T3 cells were treated with PQQ in the presence of 0.5% calf serum in DMEM, the cells showed significantly increased viability. After PQQ addition, flow cytometric analysis revealed a decrease in the population of cells in the G0/G1 phase and a concomitant increase in cells in the S and G2/M phases. Although treatment with SNAP, an NO donor, reduced cell viability, this effect was abolished by the addition of PQQ. Activation of ERK and PKC-epsilon was detected immediately after the addition of PQQ, and subsequent increases in the phosphorylation of Rb and c-Jun were observed. On the other hand, protein expression levels of growth-inhibitory molecules such as IkappaB and p27 decreased after PQQ treatment. These results suggest that PQQ stimulates cell proliferation through NO-sensitive Ras-mediated signaling pathways.


Asunto(s)
Fibroblastos/efectos de los fármacos , Fibroblastos/metabolismo , Cofactor PQQ/farmacología , Transducción de Señal/efectos de los fármacos , Proteínas ras/metabolismo , 1-(5-Isoquinolinesulfonil)-2-Metilpiperazina/farmacología , Animales , Western Blotting , Ciclo Celular/efectos de los fármacos , Línea Celular Transformada , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Eflornitina/farmacología , Fibroblastos/citología , Citometría de Flujo , Genisteína/farmacología , Hidroquinonas/farmacología , Ratones , Modelos Biológicos , Células 3T3 NIH , Cofactor PQQ/química , S-Nitroso-N-Acetilpenicilamina/farmacología
11.
J Pharm Biomed Anal ; 44(2): 602-7, 2007 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-17267160

RESUMEN

Methamphetamine and amphetamine were extracted from human urine samples using pipette tip solid-phase extraction (SPE) with MonoTip C18 tips (pipette tip volume, 200 microl), in which C18-bonded monolithic silica gel was fixed. A sample of human urine (0.5 ml) containing methamphetamine, amphetamine, and N-methylbenzylamine as internal standard (IS), was mixed with 25 microl of 1M sodium hydroxide solution. The mixture was extracted into the C18 phase of the SPE tip by 25 repeated aspirating/dispensing cycles using a manual micropipettor. Analytes retained in the C18 phase were then eluted with methanol by five repeated aspirating/dispensing cycles. After derivatization with trifluoroacetic anhydride, analytes were measured by gas chromatography/mass spectrometry with selected ion monitoring in the positive-ion electron impact mode. Recoveries of methamphetamine, amphetamine, and IS spiked into urine were more than 82.9, 82.2, and 78.2%, respectively. Regression equations for methamphetamine and amphetamine showed excellent linearity in the range of 0.25-200 ng/0.5 ml. Limit of detection was 0.04 ng/0.5 ml for methamphetamine and 0.05 ng/0.5 ml for amphetamine. Intra- and inter-day coefficients of variations for both stimulants were not greater than 10.8%. The data obtained from actual determination of methamphetamine and amphetamine in autopsy urine samples are also presented for validation of the method.


Asunto(s)
Anfetaminas/orina , Estimulantes del Sistema Nervioso Central/orina , Metanfetamina/orina , Autopsia , Toxicología Forense , Cromatografía de Gases y Espectrometría de Masas , Humanos , Indicadores y Reactivos , Control de Calidad , Estándares de Referencia , Reproducibilidad de los Resultados , Extracción en Fase Sólida , Soluciones
12.
Leg Med (Tokyo) ; 24: 36-55, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28081789

RESUMEN

A high-throughput method was developed for the detection of 31 benzodiazepine drugs and tandospirone in human plasma by on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry. Plasma samples (100µl) spiked with the 32 drugs and oxazepam-d5 (internal standard) were diluted with 300µl of 13.3mM ammonium acetate/acetonitrile (33:67, v/v). After centrifugation and filtration, the clear supernatant was injected directly onto the extraction column (Oasis HLB cartridge column). The following procedure was fully automated. The analytes retained on the extraction column were eluted by backflushing of the extraction column and introduced into an analytical column (SUMIPAX ODS D-Swifter column, 30mm×3.0mm i.d.; particle size 2µm) by column switching. Quantification was performed by multiple reaction monitoring with positive-ion electrospray ionization. Distinct peaks appeared for each drug and the internal standard on each channel within 7min, including the extraction time. All drugs spiked into plasma showed recoveries of 83-95%. The regression equations for the 32 drugs showed excellent linearities in the range of 50-2000pg/ml of plasma and the limits of detection ranged from 20 to 50pg/ml. The lower and upper limits of quantitation were 50-100ng/ml and 2000pg/ml, respectively. Intra- and interday coefficients of variation for none of the drugs were greater than 13.6%. The accuracies of quantitation were 87-112%. The multiple reaction monitoring information-dependent acquisition of enhanced product ions method enabled the quantification and confirmation of diazepam, triazolam, and lorazepam obtained from actual plasma.


Asunto(s)
Benzodiazepinas/sangre , Cromatografía Líquida de Alta Presión , Isoindoles/sangre , Piperazinas/sangre , Pirimidinas/sangre , Espectrometría de Masas en Tándem/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
13.
Artículo en Inglés | MEDLINE | ID: mdl-16893687

RESUMEN

A method for the simultaneous determination of selegiline and its metabolite, desmethylselegiline, in human whole blood and urine is presented. The method, which combines a fiber-based headspace solid-phase microextraction (SPME) technique with gas chromatography-mass spectrometry (GC-MS), required optimization of various parameters (e.g., salt additives, extraction temperatures, extraction times and the extraction properties of the SPME fiber coatings). Pargyline was used as the internal standard. Extraction efficiencies for both selegiline and desmethylselegiline were 2.0-3.4% for whole blood, and 8.0-13.2% for urine. The regression equations for selegiline and desmethylselegiline extracted from whole blood were linear (r(2)=0.996 and 0.995) within the concentration ranges 0.1-10 and 0.2-20 ng/ml, respectively. For urine, the regression equations for selegiline and desmethylselegiline were linear (r(2)=0.999 and 0.998) within the concentration ranges 0.05-5.0 and 0.1-10 ng/ml, respectively. The limit of detection for selegiline and desmethylselegiline was 0.01-0.05 ng/ml for both samples. The lower and upper limits of quantification for each compound were 0.05-0.2 and 5-20 ng/ml, respectively. Intra- and inter-day coefficients of variation for selegiline and desmethylselegiline in both samples were not greater than 8.7 and 11.7%, respectively. The determination of selegiline and desmethylselegiline concentrations in Parkinson's disease patients undergoing continuous selegiline treatment is presented and is shown to validate the present methodology.


Asunto(s)
Anfetaminas/análisis , Líquidos Corporales/química , Cromatografía de Gases y Espectrometría de Masas/métodos , Selegilina/análisis , Microextracción en Fase Sólida/métodos , Anfetaminas/sangre , Anfetaminas/orina , Humanos , Estructura Molecular , Reproducibilidad de los Resultados , Selegilina/sangre , Selegilina/orina
14.
J Pharm Biomed Anal ; 41(1): 64-9, 2006 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-16378708

RESUMEN

Triazolam was analyzed from human plasma samples by high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) with an MSpak GF polymer column (50 mm x 4.6 mm i.d., particle size 6 microm), which enabled direct injection of crude biological samples. Separation of triazolam, and lorazepam as the internal standard (IS) was carried out using 10mM ammonium acetate (pH 3.56)-0.1% formic acid and an acetonitrile gradient elution. Both compounds formed base peaks due to [M + H]+ ions by HPLC/ESI-MS, and product ions were produced from each [M + H]+ ion as seen by HPLC-MS/MS. Quantification of triazolam and the IS in plasma samples was made by selective reaction monitoring using each base peak of product ions of HPLC-MS/MS. The recovery range of triazolam spiked into plasma was 86.4-92.7%. The regression equation for triazolam showed excellent linearity in the range of 0.25-20 ng/mL, and the detection limit was 0.1 ng/mL. Intra- and inter-day precisions for triazolam in plasma samples were not greater than 12.4%. Accuracy for the drug was in the range of 88.0-101.4%. Data obtained after oral administration of triazolam in male and female subjects are also presented.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas/métodos , Triazolam/análisis , Triazolam/sangre , Acetonitrilos/química , Administración Oral , Adulto , Química Farmacéutica/métodos , Femenino , Formiatos/química , Humanos , Concentración de Iones de Hidrógeno , Masculino , Modelos Químicos , Análisis de Regresión , Reproducibilidad de los Resultados
15.
J AOAC Int ; 88(6): 1655-60, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16526447

RESUMEN

Seven phenothiazine derivatives, perazine, perphenazine, prochlorperazine, propericiazine, thioproperazine, trifluoperazine, and flupentixol, have been found to be extractable from human plasma and urine samples using disk solid-phase extraction (SPE) with an Empore C18 cartridge. Human plasma and urine (1 mL each) containing the 7 phenothiazine derivatives were mixed with 2 mL of 0.1M NaOH and 7 mL distilled water and then poured into the disk SPE cartridges. The drugs were eluted with 1 mL chloroform- acetonitrile (8 + 2) and determined by liquid chromatography with ammonium formate/formic acid-acetonitrile gradient elution. The detection was performed by ultraviolet absorption at 250 nm. The separation of the 7 phenothiazine derivatives from each other and from impurities was generally satisfactory using a SymmetryShield RP8 column (150 x 2.1 mm id, 3.5 microm particle size). The recoveries of the 7 phenothiazine derivatives spiked into plasma and urine samples were 64.0-89.9% and 65.1-92.1%, respectively. Regression equations for the 7 phenothiazine derivatives showed excellent linearity, with detection limits of 0.021-0.30 microg/mL for plasma and 0.017-0.30 microg/mL for urine. The within-day and day-to-day coefficients of variation for both samples were commonly below 9.0 and 14.9%, respectively.


Asunto(s)
Líquidos Corporales/metabolismo , Cromatografía Liquida/métodos , Fenotiazinas/análisis , Acetonitrilos/química , Análisis Químico de la Sangre/métodos , Cloroformo/química , Humanos , Modelos Lineales , Modelos Químicos , Fenotiazinas/química , Estándares de Referencia , Análisis de Regresión , Factores de Tiempo , Urinálisis/métodos , Agua/química
16.
J Mass Spectrom ; 39(10): 1147-52, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15468125

RESUMEN

Paraquat (PQ) and diquat (DQ) in human whole blood and urine were analyzed by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) with positive ion electrospray ionization (ESI). The compounds were extracted with Sep-Pak C18 cartridges from whole blood and urine samples containing ethyl paraquat as an internal standard. The separation of PQ and DQ was carried out using ion-pair chromatography with heptafluorobutyric acid in 20 mM ammonium acetate and acetonitrile gradient elution for successful coupling with MS. Both compounds formed base peaks due to [M-H]+ ions by HPLC/ESI-MS and the product ions produced from each [M-H]+ ion by HPLC/MS/MS. Selective reaction monitoring (SRM) showed much higher sensitivity for both body fluids. Therefore, a detailed procedure for the detection of compounds by SRM with HPLC/MS/MS was established and carefully validated. The recoveries of PQ and DQ were 80.8-95.4% for whole blood and 84.2-96.7% for urine. The calibration curves for PQ and DQ showed excellent linearity in the range of 25-400 ng ml(-1) of whole blood and urine. The detection limits were 10 ng ml(-1) for PQ and 5 ng ml(-1) for DQ in both body fluids. The intra- and inter-day precision for both compounds in whole blood and urine samples were not greater than 13.0%. The data obtained from the determination of PQ and DQ in rat blood after oral administration of the compounds are also presented.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Diquat/sangre , Herbicidas/sangre , Espectrometría de Masas/métodos , Paraquat/sangre , Animales , Líquidos Corporales/química , Química Clínica/instrumentación , Diquat/análisis , Diquat/orina , Herbicidas/análisis , Herbicidas/orina , Humanos , Paraquat/análisis , Paraquat/orina , Ratas
17.
Artículo en Inglés | MEDLINE | ID: mdl-12127331

RESUMEN

Haloperidol and its two metabolites, reduced haloperidol and 4-(4-chlorophenyl)-4-hydroxypiperidine (CPHP) in human plasma and urine were analyzed by HPLC-MS using a new polymer column (MSpak GF-310), which enabled direct injection of crude biological samples without pretreatment. Recoveries of haloperidol and reduced haloperidol spiked into plasma were 64.4-76.1% and 46.8-50.2%, respectively; those for urine were 87.3-99.4% and 94.2-98.5%, respectively; those of CPHP for both samples were not less than 92.7%. The regression equations for haloperidol, reduced haloperidol and CPHP showed good linearity in the ranges of 10-800, 15-800 and 400-800 ng/ml, respectively, for both plasma and urine. Their detection limits were 5, 10 and 300 ng/ml, respectively, for both samples. Thus, the present method was sensitive enough for detection and determination of high therapeutic and toxic levels for haloperidol and its metabolites present in biological samples.


Asunto(s)
Antipsicóticos/metabolismo , Cromatografía Líquida de Alta Presión/métodos , Haloperidol/metabolismo , Espectrometría de Masas/métodos , Antipsicóticos/sangre , Antipsicóticos/orina , Haloperidol/sangre , Haloperidol/orina , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrofotometría Ultravioleta
18.
Artículo en Inglés | MEDLINE | ID: mdl-12829004

RESUMEN

We have presented a simple and sensitive method for determining pethidine, a narcotic analgesic drug in body fluids by gas chromatography-tandem mass spectrometry (GC-MS/MS). Pethidine and 4'-piperidinoacetophenone (internal standard) were extracted from body fluids with Bond Elut C(18) columns; the recoveries were above 85% for both compounds. The calibration curves for blood and urine showed good linearities in the range of 1.25-40 ng/ml. Its detection limits (signal-to-noise ratio=3) were estimated to be approximately 0.5 ng/ml of whole blood and urine.


Asunto(s)
Analgésicos Opioides/metabolismo , Meperidina/metabolismo , Analgésicos Opioides/sangre , Analgésicos Opioides/orina , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Meperidina/sangre , Meperidina/orina , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Artículo en Inglés | MEDLINE | ID: mdl-15149613

RESUMEN

Simultaneous determination of seven barbiturates in human whole blood and urine by combining direct immersion solid-phase microextraction (DI-SPME) with gas chromatography-mass spectrometry (GC-MS) is presented. The main parameters affecting the DI-SPME process, such as SPME fibers, salt additives, pHs, extraction temperatures and immersion times were optimized for simultaneous determination of the drugs. The extraction efficiencies were 0.0180-0.988 and 0.0156-2.76% for whole blood and urine, respectively. The regression equations of the drugs showed excellent linearity for both samples; the correlation coefficients (r(2)) were 0.994-0.999. The detection limits for whole blood were 0.05-1 microg x ml(-1), and those for urine 0.01-0.6 microg x ml(-1). Actual quantitation could be made for pentobarbital in whole blood and urine obtained from volunteers, who had been orally administered a therapeutic dose of the drug. The DI-SPME/GC-MS procedure for barbiturates established in this study is simple and sensitive enough to be adopted in the fields of clinical and forensic toxicology.


Asunto(s)
Barbitúricos/sangre , Barbitúricos/orina , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
J Pharm Biomed Anal ; 88: 71-80, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24036363

RESUMEN

A simple and sensitive method was developed and validated here for the analysis of thirteen nonsteroidal anti-inflammatory drugs (NSAIDs) in human plasma samples by hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry (MS/MS). A small volume of plasma (20µL) spiked with compounds was diluted with 80µL of 10-mM ammonium acetate followed by a simple protein precipitation with 400µL of acetonitrile. After centrifugation, the clear supernatant extract was directly injected into the HILIC-MS/MS, without any solvent evaporation and reconstitution steps. The chromatographic separation of the NSAIDs was achieved on a Unison UK-Amino HILIC column (50mm×3mm i.d., particle size 3µm) with a linear gradient elution system composed of 10mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.4mL/min. The mass spectra obtained by HILIC-MS showed base peak ions due to [M+H](+) for indomethacin, oxaprozin, ketoprofen, alminoprofen, zaltoprofen, tiaprofenic acid, pranoprofen, and ketoprofen-d3 and due to [M-H](-) for etodolac, ibuprofen, diclofenac, fenoprofen, loxoprofen, naproxen, and ibuprofen-d3. Recoveries of these thirteen NSAIDs in plasma were 34.8-113% and the lower limits of quantitation were 0.125-1.25µg/mL. The intra- and interday coefficient of variations for all drugs in plasma were less than 14.6%. The data obtained from actual plasma determinations of zaltoprofen, ibuprofen, and diclofenac are also presented.


Asunto(s)
Antiinflamatorios/sangre , Análisis Químico de la Sangre , Monitoreo de Drogas , Espectrometría de Masas en Tándem , Acetatos/química , Acetonitrilos/química , Administración Oral , Adulto , Antiinflamatorios no Esteroideos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Masculino , Persona de Mediana Edad , Control de Calidad , Análisis de Regresión , Reproducibilidad de los Resultados , Solventes/química
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda