Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
J Am Chem Soc ; 145(34): 18753-18759, 2023 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-37581933

RESUMEN

The asymmetric difunctionalization of alkenes, a method transforming readily accessible alkenes into enantioenriched chiral structures of high value, has long been a focal point of organic synthesis. Despite tremendous efforts in this domain, it remains a considerable challenge to devise enantioselective oxidative dicarbofunctionalization of alkenes, even though these transformations can utilize stable and unfunctionalized functional group donors. In this context, we report herein a photoelectrocatalytic method for the enantioselective heteroarylcyanation of aryl alkenes, which employs unfunctionalized heteroarenes through C-H functionalization. The photoelectrochemical asymmetric catalysis (PEAC) method combines photoredox catalysis and asymmetric electrocatalysis to facilitate the formation of two C-C bonds operating via hydrogen (H2) evolution and obviating the need for external chemical oxidants.

2.
Chin Med Sci J ; 38(2): 117-124, 2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-37050845

RESUMEN

Background A simple measurement of central venous pressure (CVP)-mean by the digital monitor display has become increasingly popular. However, the agreement between CVP-mean and CVP-end (a standard method of CVP measurement by analyzing the waveform at end-expiration) is not well determined. This study was designed to identify the relationship between CVP-mean and CVP-end in critically ill patients and to introduce a new parameter of CVP amplitude (ΔCVP= CVPmax - CVPmin) during the respiratory period to identify the agreement/disagreement between CVP-mean and CVP-end.Methods In total, 291 patients were included in the study. CVP-mean and CVP-end were obtained simultaneously from each patient. CVP measurement difference (|CVP-mean - CVP-end|) was defined as the difference between CVP-mean and CVP-end. The ΔCVP was calculated as the difference between the peak (CVPmax) and the nadir value (CVPmin) during the respiratory cycle, which was automatically recorded on the monitor screen. Subjects with |CVP-mean - CVP-end|≥ 2 mmHg were divided into the inconsistent group, while subjects with |CVP-mean - CVP-end| < 2 mmHg were divided into the consistent group.Results ΔCVP was significantly higher in the inconsistent group [7.17(2.77) vs.5.24(2.18), P<0.001] than that in the consistent group. There was a significantly positive relationship between ΔCVP and |CVP-mean - CVP-end| (r=0.283, P <0.0001). Bland-Altman plot showed the bias was -0.61 mmHg with a wide 95% limit of agreement (-3.34, 2.10) of CVP-end and CVP-mean. The area under the receiver operating characteristic curves (AUC) of ΔCVP for predicting |CVP-mean - CVP-end| ≥ 2 mmHg was 0.709. With a high diagnostic specificity, using ΔCVP<3 to detect |CVP-mean - CVP-end| lower than 2mmHg (consistent measurement) resulted in a sensitivity of 22.37% and a specificity of 93.06%. Using ΔCVP>8 to detect |CVP-mean - CVP-end| >8 mmHg (inconsistent measurement) resulted in a sensitivity of 31.94% and a specificity of 91.32%.Conclusions CVP-end and CVP-mean have statistical discrepancies in specific clinical scenarios. ΔCVP during the respiratory period is related to the variation of the two CVP methods. A high ΔCVP indicates a poor agreement between these two methods, whereas a low ΔCVP indicates a good agreement between these two methods.


Asunto(s)
Respiración , Humanos , Presión Venosa Central , Curva ROC
3.
J Am Chem Soc ; 144(44): 20201-20206, 2022 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-36315651

RESUMEN

The development of efficient and sustainable methods for decarboxylative transformations is of great importance due to the ease of availability and nontoxicity of carboxylic acids. Despite tremendous efforts in this area, it remains challenging to develop enantioselective transformations direct from carboxylic acids. Herein we disclose a photoelectrocatalytic method for the direct and enantioselective decarboxylative cyanation. The photoelectrochemical reactions convert carboxylic acids to enantioenriched nitriles by employing cerium/copper relay catalysis with a cerium salt for catalytic decarboxylation and a chiral copper complex for stereoselective C-CN formation.


Asunto(s)
Cerio , Cobre , Estereoisomerismo , Catálisis , Ácidos Carboxílicos
4.
Angew Chem Int Ed Engl ; 60(6): 2943-2947, 2021 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-33078880

RESUMEN

C-H/N-H cross-coupling is an ideal strategy to synthesize various amines but remains challenging owing to the requirement for sacrificial chemical oxidants and the difficulty in controlling the regio- and chemo-selectivity. Herein we report a site-selective electrochemical amination reaction that can convert benzylic C-H bonds into C-N linkages via H2 evolution without need for external oxidants or metal catalysts. The synthetic strategy involves anodic cleavage of benzylic C-H to form a carbocation intermediate, which is then trapped with an amine nucleophile leading to C-N bond formation. Key to the success is to include HFIP as a co-solvent to modulate the oxidation potentials of the alkylbenzene substrate and the aminated product to avoid overoxidation of the latter.

5.
Angew Chem Int Ed Engl ; 59(26): 10626-10632, 2020 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-32227555

RESUMEN

Decarboxylative C-H functionalization reactions are highly attractive methods for forging carbon-carbon bonds considering their inherent step- and atom-economical features and the pervasiveness of carboxylic acids and C-H bonds. An ideal approach to achieve these dehydrogenative transformations is through hydrogen evolution without using any chemical oxidants. However, effective couplings by decarboxylative carbon-carbon bond formation with proton reduction remain an unsolved challenge. Herein, we report an electrophotocatalytic approach that merges organic electrochemistry with photocatalysis to achieve the efficient direct decarboxylative C-H alkylation and carbamoylation of heteroaromatic compounds through hydrogen evolution. This electrophotocatalytic method, which combines the high efficiency and selectivity of photocatalysis in promoting decarboxylation with the superiority of electrochemistry in effecting proton reduction, enables the efficient coupling of a wide range of heteroaromatic bases with a variety of carboxylic acids and oxamic acids. Advantageously, this method is scalable to decagram amounts, and applicable to the late-stage functionalization of drug molecules.

6.
J Clin Monit Comput ; 30(5): 569-75, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26298710

RESUMEN

We know that a 10 cm departure from the reference level of pressure transducer position is equal to a 7.5 mmHg change of invasive hemodynamic pressure monitoring in a fluid-filled system. However, the relationship between the site level of a variable arterial pressure transducer and the pulse contour-derived parameters has yet to be established in critically ill patients. Moreover, the related quantitative analysis has never been investigated. Forty-two critically ill patients requiring PiCCO-Plus cardiac output monitoring were prospectively studied. The phlebostatic axis was defined as the zero reference level; the arterial pressure transducer was then vertically adjusted to different positions (+5, +10, +15, +20, -20, -15, -10, -5 cm) of departure from the zero reference site. The pulse contour waveform-derived parameters were recorded at each position. Elevation of the pressure transducer caused significantly positive changes in the continuous cardiac index (+CCI), stroke volume index (+SVI), and stroke volume variation (+SVV), and negative changes in the rate of left ventricular pressure rise during systole (-dP/dtmax), the systemic vascular resistance index (-SVRI), and vice versa. At the 5 cm position, the SVRI changes reached statistical significance with error. At the 10 cm position, the changes in CCI and dP/dtmax reached statistical significance with error, while the change in SVV reached statistical significance at 15 cm. The change rate of CCI was more than 5 % at the 15 cm position and approximately 10 % at the 20 cm position. On average, for every centimeter change of the transducer, there was a corresponding 0.014 L/min/m(2) CCI change and 0.36 % change rate, a 1.41 mmHg/s dP/dtmax change and 0.13 % change rate, and a 25 dyne/s/cm(5) SVRI change and 1.2 % change rate. The variation of arterial transducer position can result in inaccurate measurement of pulse contour waveform-derived parameters, especially when the transducer's vertical distance is more than 10 cm from the phlebostatic axis. These findings have clinical implications for continuous hemodynamic monitoring.


Asunto(s)
Presión Arterial , Pulso Arterial , Transductores , Adulto , Anciano , Arterias/patología , Presión Sanguínea , Gasto Cardíaco , Cuidados Críticos/métodos , Enfermedad Crítica , Femenino , Frecuencia Cardíaca , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Presión , Estudios Prospectivos , Reproducibilidad de los Resultados , Volumen Sistólico , Sístole
7.
World J Clin Cases ; 10(2): 511-517, 2022 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-35097076

RESUMEN

BACKGROUND: Improper methods of contraception greatly increase the risk of abortion, cervical or endometrial lesions, and the number of recurrent artificial abortions. These complications result in the deterioration of a patient's outcome. Further, the proportion of artificial abortions is highest among unmarried females. Placement of an intrauterine device, such as the Mirena, after an artificial abortion may decrease the likelihood of an endometrial injury caused by recurrent abortions while significantly improving its contraceptive effects. AIM: To discuss the effect of Mirena placement on reproductive hormone levels at different time points after an artificial abortion. METHODS: Women (n = 119) undergoing an artificial abortion operation were divided into the study (n = 56) and control (n = 63) groups. In the study group, the Mirena was inserted immediately after the artificial abortion, whereas in the control group, it was inserted 4-7 d after the onset of the first menstrual cycle after abortion. All participants were followed-up for 6 mo to observe the continuation and expulsion rates and adverse reactions and to measure the levels of serum estradiol (E2), follicle stimulating hormone (FSH), and luteinizing hormone (LH). RESULTS: The continuation rates were 94.64% and 93.65% in the study group and the control group, respectively. The expulsion rates were 1.79% and 3.17% in the study group and the control group, respectively. There was no statistically significant difference between the two groups (P > 0.05). There were also no statistically significant differences in the proportion of patients with bacterial vaginitis, trichomonas vaginitis, or cervicitis between the groups (P > 0.05). Six months after Mirena placement, E2 Levels were 45.50 ± 7.13 pg/mL and 42.91 ± 8.10 pg/mL, FSH 13.60 ± 3.24 mIU/mL and 14.54 ± 3.11 mIU/mL, and LH 15.11 ± 2.08 mIU/mL and 14.60 ± 3.55 mIU/mL in the study and control groups, respectively. There were no significant differences in hormone levels between the two groups (P > 0.05). There were also no statistically significant differences in the proportions of abnormal menstruation, prolonged menstruation, or pain during intercourse between the study and control groups after Mirena placement (P > 0.05). There were no statistically significant differences in uterine volume, sexual desire, sexual activity, or the sexual satisfaction score between the study and control groups before and after Mirena placement (P > 0.05). CONCLUSION: Placement of a Mirena intrauterine device immediately after an artificial abortion does not increase the risk of adverse reactions and can help prevent endometrial injury caused by recurrent abortions.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda