Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Anaesthesia ; 76(3): 381-392, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32681570

RESUMEN

Modern four-factor prothrombin complex concentrate was designed originally for rapid targeted replacement of the coagulation factors II, VII, IX and X. Dosing strategies for the approved indication of vitamin K antagonist-related bleeding vary greatly. They include INR and bodyweight-related protocols as well as fixed dose regimens. Particularly in the massively bleeding trauma and cardiac surgery patient, four-factor prothrombin complex concentrate is used increasingly for haemostatic resuscitation. Members of the Transfusion and Haemostasis Subcommittee of the European Association of Cardiothoracic Anaesthesiology performed a systematic literature review on four-factor prothrombin complex concentrate. The available evidence has been summarised for dosing, efficacy, drug safety and monitoring strategies in different scenarios. Whereas there is evidence for the efficacy of four-factor prothrombin concentrate for a variety of bleeding scenarios, convincing safety data are clearly missing. In the massively bleeding patient with coagulopathy, our group recommends the administration of an initial bolus of 25 IU.kg-1 . This applies for: the acute reversal of vitamin K antagonist therapy; haemostatic resuscitation, particularly in trauma; and the reversal of direct oral anticoagulants when no specific antidote is available. In patients with a high risk for thromboembolic complications, e.g. cardiac surgery, the administration of an initial half-dose bolus (12.5 IU.kg-1 ) should be considered. A second bolus may be indicated if coagulopathy and microvascular bleeding persists and other reasons for bleeding are largely ruled out. Tissue-factor-activated, factor VII-dependent and heparin insensitive point-of-care tests may be used for peri-operative monitoring and guiding of prothrombin complex concentrate therapy.


Asunto(s)
Factores de Coagulación Sanguínea/uso terapéutico , Pérdida de Sangre Quirúrgica/prevención & control , Consenso , Hemorragia Posoperatoria/tratamiento farmacológico , Europa (Continente) , Humanos , Guías de Práctica Clínica como Asunto
2.
Anaesthesia ; 74(12): 1589-1600, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31531856

RESUMEN

To date, data regarding the efficacy and safety of administering fibrinogen concentrate in cardiac surgery are limited. Studies are limited by their low sample size and large heterogeneity with regard to the patient population, by the timing of fibrinogen concentrate administration, and by the definition of transfusion trigger and target levels. Assessment of fibrinogen activity using viscoelastic point-of-care testing shortly before or after weaning from cardiopulmonary bypass in patients and procedures with a high risk of bleeding appears to be a rational strategy. In contrast, the use of Clauss fibrinogen test for determination of plasma fibrinogen level can no longer be recommended without restrictions due to its long turnaround time, high inter-assay variability and interference with high heparin levels and fibrin degradation products. Administration of fibrinogen concentrate for maintaining physiological fibrinogen activity in the case of microvascular post-cardiopulmonary bypass bleeding appears to be indicated. The available evidence does not suggest aiming for supranormal levels, however. Use of cryoprecipitate as an alternative to fibrinogen concentrate might be considered to increase plasma fibrinogen levels. Although conclusive evidence is lacking, fibrinogen concentrate does not seem to increase adverse outcomes (i.e., thromboembolic events). Large prospective multi-centre studies are needed to better define the optimal perioperative monitoring tool, transfusion trigger and target levels for fibrinogen replacement in cardiac surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Fibrinógeno/uso terapéutico , Cirugía Torácica/métodos , Anestesiología , Consenso , Fibrinógeno/efectos adversos , Fibrinógeno/metabolismo , Homeostasis , Humanos , Monitoreo Fisiológico
3.
Perfusion ; 32(1): 27-34, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27424311

RESUMEN

Low-flow extracorporeal life support can be used for cardiopulmonary support of paediatric and neonatal patients and is also emerging as a therapy for patients suffering from exacerbation of chronic obstructive pulmonary disease. However, pump heating and haemolysis have proven to negatively affect the system and outcome. This in vitro study aimed at gaining insight into blood warming, pump heating and haemolysis related to the performance of a new low-flow centrifugal pump. Pump performance in the 400-1,500 ml/min flow range was modulated using small-sized dual-lumen catheters and freshly donated human blood. Measurements included plasma free haemoglobin, blood temperature, pump speed, pump pressure, blood flow and thermographic imaging. Blood warming (ΔTmax=0.5°C) had no relationship with pump performance or haemolysis (R2max=0.05). Pump performance-related parameters revealed no relevant relationships with haemolysis (R2max=0.36). Thermography showed no relevant heat zones in the pump (Tmax=36°C). Concerning blood warming, pump heating and haemolysis, we deem the centrifugal pump applicable for low-flow extracorporeal circulation.


Asunto(s)
Oxigenación por Membrana Extracorpórea/instrumentación , Hemólisis , Catéteres , Centrifugación/instrumentación , Diseño de Equipo , Calefacción , Humanos , Termografía
4.
Br J Anaesth ; 112(5): 852-9, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24486836

RESUMEN

BACKGROUND: Post-partum haemorrhage (PPH) causes rapidly developing deficiencies in clotting factors and contributes to substantial maternal morbidity and mortality. Rotational thromboelastometry (ROTEM(®)) is increasingly used as a point of care coagulation monitoring device in patients with massive haemorrhage; however, there are limited data on reference ranges in the peri-partum period. These are required due to the haemostatic changes in pregnancy. METHODS: In a Dutch multi-centre trial, 161 subjects were included; blood samples were obtained during labour (T1) and within 1 h of delivery (T2). Reference ranges of ROTEM(®) INTEM, EXTEM, FIBTEM, and APTEM were set and correlation with laboratory results was investigated using the guidelines of the International Federation of Clinical Chemistry. RESULTS: Reference ranges were obtained for clotting time (CT), clot formation time (CFT), α-angle, clot firmness at 10 and 20 min (A10, A20), maximum clot firmness (MCF), and maximum lysis (ML). These were comparable from centre to centre, and between T1 and T2. Reference ranges T1: EXTEM: CT 31-63 s, CFT 41-120 s, and MCF 42-78 mm. INTEM: CT 109-225 s, CFT 40-103, and MCF 63-78 mm. FIBTEM: CT 31-79 s and MCF 13-45 mm. APTEM: CT 33-62 s, CFT 42-118, and MCF 61-79 mm. CONCLUSIONS: Reference values for ROTEM(®) parameters are reported. The previously published correlation between FIBTEM parameters and plasma fibrinogen levels by the Clauss method is confirmed. Further research is needed to define threshold values for haemostatic therapy in the course of PPH. Clinical trial registration NTR 2515 (http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2515).


Asunto(s)
Coagulación Sanguínea/fisiología , Monitoreo Fisiológico/métodos , Hemorragia Posparto/diagnóstico , Tromboelastografía/métodos , Adulto , Pruebas de Coagulación Sanguínea/métodos , Pruebas de Coagulación Sanguínea/estadística & datos numéricos , Femenino , Humanos , Monitoreo Fisiológico/estadística & datos numéricos , Países Bajos , Periodo Periparto , Embarazo , Valores de Referencia , Tromboelastografía/estadística & datos numéricos
5.
Vox Sang ; 103(1): 79-82, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22220640

RESUMEN

Blood sample transport via pneumatic tube systems (PTS) reduces the turnaround time of laboratories, but it might influence analysis results. Its effect on platelet concentrates (PCs) is not known. Platelet function was investigated after single and multiple PTS transport in comparison with storage and irradiation. Optical and impedance aggregation, CD-62, and microparticles changed as a result of storage, but not due to transport. Irradiation lowered platelet function independently. Multiple transport impaired thrombin receptor-activating peptide-induced aggregation. This investigation demonstrates the feasibility of PTS transport. As platelet function depends on storage, it may be more important to transfuse fresh PCs.


Asunto(s)
Plaquetas/química , Manejo de Especímenes/métodos , Conservación de la Sangre , Estudios de Factibilidad , Humanos , Activación Plaquetaria , Agregación Plaquetaria , Transfusión de Plaquetas , Factores de Tiempo
6.
Vox Sang ; 103(1): 25-34, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22211833

RESUMEN

BACKGROUND AND OBJECTIVES: Treatment of dilutional coagulopathy by transfusing fresh frozen plasma (FFP) remains sub-optimal. We hypothesized that partial replacement of transfused FFP by fibrinogen concentrate results in improved coagulant activity and haemostasis. This was tested in a controlled clinical intervention trial with patients experiencing massive bleeding during major surgery. METHODS: Patients undergoing major elective surgery were treated according to current protocols. When transfusion with FFP was required, patients were randomized as follows: group A received 4 units FFP and group B received 2 units FFP plus 2 g fibrinogen concentrate. Blood samples were taken before and after the intervention. Analysts were blinded to the treatment type. RESULTS: Group A (B) consisted of 21 (22) patients, in 16 (17) of whom bleeding stopped after intervention. Plasma fibrinogen increased significantly more in group B (0·57 g/l) than in group A (0·05 g/l). However, levels of prothrombin and factors VIII, IX and X increased more in group A than in group B. Rotational thromboelastometry (ROTEM) of whole blood and plasma revealed improved fibrin clot formation in group B but not in group A. Thrombin generation [calibrated automated thrombogram (CAT)] in plasma increased more in group A. Principal parameters determining whole-blood thromboelastometry were the fibrinogen level and platelet count. In vitro addition of fibrinogen and prothrombin complex concentrate to pre-intervention samples restored both ROTEM and CAT parameters. CONCLUSIONS: Partial replacement of transfused FFP by fibrinogen increases fibrin clot formation at the expense of less improved thrombin generation. Coagulation factors other than fibrinogen alone are required for full restoration of haemostasis.


Asunto(s)
Trastornos de la Coagulación Sanguínea/terapia , Transfusión de Componentes Sanguíneos , Fibrinógeno/uso terapéutico , Procedimientos Quirúrgicos Operativos/efectos adversos , Procedimientos Quirúrgicos Operativos/métodos , Anciano , Trastornos de la Coagulación Sanguínea/sangre , Trastornos de la Coagulación Sanguínea/etiología , Factores de Coagulación Sanguínea/metabolismo , Pérdida de Sangre Quirúrgica/prevención & control , Femenino , Fibrina/efectos de los fármacos , Fibrina/metabolismo , Hemostasis/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Plasma/metabolismo , Recuento de Plaquetas , Hemorragia Posoperatoria/prevención & control , Hemorragia Posoperatoria/terapia , Estudios Prospectivos , Tromboelastografía
8.
Perfusion ; 25(1): 25-9, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20118166

RESUMEN

Extracorporeal life support systems lack volume-buffering capacity. Therefore, any decrease in venous intravascular volume available for drainage may result in acutely reduced support flow. We recently developed a method to quantify drainable volume and now conceived a reserve-driven pump control strategy, which is different from existing pressure or flow servo control schemes. Here, we give an outline of the algorithm and present animal experimental data showing proof of principle. With an acute reduction in circulatory volume (10-15%), pump flow immediately dropped from 4.1 to 1.9 l/min. Our pump control algorithm was able to restore bypass flow to 3.2 l/min (about 80% of the original level) and, thereby, reduced the duration of the low-flow condition. This demonstrates that a reserve-driven pump control strategy, based on the continuous monitoring of drainable volume, may maintain extracorporeal circulatory support flow, despite serious changes in filling conditions.


Asunto(s)
Circulación Extracorporea/instrumentación , Circulación Extracorporea/métodos , Bombas de Infusión , Cuidados para Prolongación de la Vida/instrumentación , Cuidados para Prolongación de la Vida/métodos , Algoritmos , Animales , Volumen Sanguíneo , Puente Cardiopulmonar/instrumentación , Puente Cardiopulmonar/métodos , Computadores , Diseño de Equipo , Femenino , Cabras , Hemodinámica , Modelos Animales , Programas Informáticos
11.
Biomed Res Int ; 2017: 2635151, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29130036

RESUMEN

INTRODUCTION: Evaluation of accuracy, precision, and trending ability of cardiac index (CI) measurements using the Aesculon™ bioimpedance electrical cardiometry (Aesc) compared to the continuous pulmonary artery thermodilution catheter (PAC) technique before, during, and after cardiac surgery. METHODS: A prospective observational study with fifty patients with ASA 3-4. At six time points (T), measurements of CI simultaneously by continuous cardiac output pulmonary thermodilution and thoracic bioimpedance and standard hemodynamics were performed. Analysis was performed using Bland-Altman, four-quadrant plot, and polar plot methodology. RESULTS: CI obtained with pulmonary artery thermodilution and thoracic bioimpedance ranged from 1.00 to 6.75 L min-1 and 0.93 to 7.25 L min-1, respectively. Bland-Altman analysis showed a bias between CIBIO and CIPAC of 0.52 liters min-1 m-2, with LOA of [-2.2; 1.1] liters min-1 m-2. Percentage error between the two techniques was above 30% at every time point. Polar plot methodology and 4-quadrant analysis showed poor trending ability. Skin incision had no effect on the results. CONCLUSION: CI obtained by continuous PAC and CI obtained by Aesculon bioimpedance are not interchangeable in cardiac surgical patients. No effects of skin incision were found. International clinical trial registration number is ISRCTN26732484.


Asunto(s)
Fenómenos Electrofisiológicos , Arteria Pulmonar/fisiología , Termodilución/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
12.
Respir Investig ; 54(4): 241-9, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27424823

RESUMEN

Upper airway stimulation, specifically hypoglossal (CN XII) nerve stimulation, is a new, alternative therapy for patients with obstructive sleep apnea hypopnea syndrome who cannot tolerate positive airway pressure, the first-line therapy for symptomatic patients. Stimulation therapy addresses the cause of inadequate upper airway muscle activation for nasopharyngeal and oropharyngeal airway collapse during sleep. The purpose of this report is to outline the development of this first-in-class therapy and its clinical implementation. Another practical theme is assessment of the features for considering a surgically implanted device and the insight as to how both clinical and endoscopic criteria increase the likelihood of safe and durable outcomes for an implant and how to more generally plan for management of CPAP-intolerant patients. A third theme is the team building required among sleep medicine and surgical specialties in the provision of individualized neurostimulation therapy.


Asunto(s)
Nervio Hipogloso/fisiología , Apnea Obstructiva del Sueño/terapia , Humanos
13.
J Thromb Haemost ; 13(8): 1503-13, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25988848

RESUMEN

BACKGROUND: Patients undergoing major cardiothoracic surgery are subjected to dilution, owing to massive fluid infusion and blood component transfusion. These patients may experience bleeding perioperatively, and are frequently treated with the endothelium-activating agent desmopressin. OBJECTIVES: To investigate the effect of desmopressin administration on von Willebrand factor (VWF)-dependent coagulant and platelet functions under flow conditions. PATIENTS/METHODS: Blood from 16 patients with postoperative bleeding was obtained before and after desmopressin treatment (0.3 µg kg(-1) body weight), and assessed for coagulant properties and platelet function. Furthermore, VWF antigen levels and multimer composition were determined in both samples. RESULTS: Desmopressin treatment did not change thrombin generation in plasma or whole blood thromboelasticity. Also coagulation factor levels (other than factor VIII) and coagulation times were unchanged, suggesting that desmopressin treatment did not have a major effect on the coagulant activity. On the other hand, desmopressin treatment raised the already high plasma levels of VWF from a median of 116 IU mL(-1) (interquartile range [IQR] 102-154 IU mL(-1) ) to a median of 160 IU mL(-1) (IQR 126-187 IU mL(-1) ) (P = 0.007), owing to accumulation of the high molecular weight VWF multimers. Furthermore, desmopressin treatment caused an increase in collagen-dependent thrombus formation and platelet phosphatidylserine exposure. Markers of thrombus formation correlated with the plasma levels of VWF. In vitro control experiments confirmed a major contribution of VWF to thrombus formation and procoagulant activity under conditions of blood dilution. CONCLUSIONS: Desmopressin treatment of patients with bleeding complications after cardiothoracic surgery induces the release of high molecular weight VWF multimers, which enhance platelet activation and thrombus formation under flow conditions.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Plaquetas/efectos de los fármacos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Desamino Arginina Vasopresina/uso terapéutico , Hemostáticos/uso terapéutico , Hemorragia Posoperatoria/tratamiento farmacológico , Anciano , Pruebas de Coagulación Sanguínea , Plaquetas/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fosfatidilserinas/sangre , Activación Plaquetaria/efectos de los fármacos , Pruebas de Función Plaquetaria , Hemorragia Posoperatoria/sangre , Hemorragia Posoperatoria/etiología , Resultado del Tratamiento , Factor de von Willebrand/metabolismo
14.
Thromb Haemost ; 111(3): 447-57, 2014 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-24258426

RESUMEN

Blood dilution after transfusion fluids leads to diminished coagulant activity monitored by rotational thromboelastometry, assessing elastic fibrin clot formation, or by thrombin generation testing. We aimed to determine the contributions of blood cells (platelets, red blood cells) and plasma factors (fibrinogen, prothrombin complex concentrate) to fibrin clot formation under conditions of haemodilution in vitro or in vivo.Whole blood or plasma diluted in vitro was supplemented with platelets, red cells, fibrinogen or prothrombin complex concentrate (PCC). Thromboelastometry was measured in whole blood as well as plasma; thrombin generation was determined in parallel. Similar tests were performed with blood from 48 patients, obtained before and after massive fluid infusion during cardiothoracic surgery.Addition of platelets or fibrinogen, in additive and independent ways, reversed the impaired fibrin clot formation (thromboelastometry) in diluted whole blood. In contrast, supplementation of red blood cells or prothrombin complex concentrate was ineffective. Platelets and fibrinogen independently restored clot formation in diluted plasma, resulting in thromboelastometry curves approaching those in whole blood. In whole blood from patients undergoing dilution during surgery, elastic clot formation was determined by both the platelet count and the fibrinogen level. Thrombin generation in diluted (patient) plasma was not changed by fibrinogen, but improved markedly by prothrombin complex concentrate. In conclusion, in dilutional coagulopathy, platelets and fibrinogen, but not red blood cells or vitamin K-dependent coagulation factors, independently determine thromboelastometry parameters measured in whole blood and plasma. Clinical decisions for transfusion based on thromboelastometry should take into account the platelet concentration.


Asunto(s)
Plaquetas/patología , Puente Cardiopulmonar , Fibrina/metabolismo , Fibrinógeno/metabolismo , Hemorragia/prevención & control , Anciano , Coagulación Sanguínea , Plaquetas/metabolismo , Eritrocitos/patología , Femenino , Hemodilución/efectos adversos , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad , Recuento de Plaquetas , Protrombina/metabolismo , Tromboelastografía , Trombina/metabolismo , Reacción a la Transfusión
15.
Thromb Haemost ; 103(2): 318-28, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20024495

RESUMEN

Patients subjected to haemodilution during surgery are at increased risk of bleeding. We hypothesised that, in the acquired dilutional coagulopathy, insufficient haemostasis is due to either insufficient thrombin generation or insufficient fibrin clot formation. In tissue factor-activated plasmas from patients with coagulation deficiency, we measured time curves of thrombin generation and fibrin clot formation (thromboelastography). Investigated were in study A: 10 patients treated with vitamin K antagonist and five healthy subjects; in study B: 30 patients undergoing cardiopulmonary bypass (CPB) surgery and infused with on average 2,000 ml crystalloids and colloids (no major bleeding); in study C: 58 patients undergoing major general surgery, and transfused with >5,000 ml crystalloids, colloids and red cell concentrates, who experienced major bleeding and were post-transfused with fresh frozen plasma. The treatment with vitamin K antagonist led to a progressive reduction in thrombin generation but not fibrin clot formation. In CPB patients, plasma factor levels post-surgery were 53-60% of normal. This was accompanied by moderate reduction in both haemostatic processes. In plasmas from patients undergoing major surgery, factor levels were 38-41% of normal, and these levels increased after plasma transfusion. Taking preset thresholds for normal thrombin generation and fibrin clot formation, at least one of these processes was low in 88-93% of the patients with (persistent) bleeding, but only in 40-53% of the patients without bleeding. In conclusion, the ability of thrombin generation and fibrin clot formation is independently reduced in acquired dilutional coagulopathy, while minimal levels of both are required for adequate haemostasis.


Asunto(s)
Fibrina/metabolismo , Hemodilución , Hemorragia/etiología , Trombina/biosíntesis , Anciano , Coagulación Sanguínea , Trastornos de la Coagulación Sanguínea/etiología , Pérdida de Sangre Quirúrgica/prevención & control , Transfusión Sanguínea , Soluciones Cristaloides , Femenino , Hemorragia/prevención & control , Hemostasis , Humanos , Soluciones Isotónicas/uso terapéutico , Cinética , Masculino , Persona de Mediana Edad , Atención Perioperativa , Hemorragia Posoperatoria/etiología , Hemorragia Posoperatoria/terapia , Vitamina K/antagonistas & inhibidores
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda