Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Hepatology ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38652643

RESUMEN

BACKGROUND AND AIMS: Noninvasive tools assessing steatosis, such as ultrasonography-based 2D-attenuation imaging (ATI), are needed to tackle the worldwide burden of steatotic liver disease. This one-stage individual patient data (IPD) meta-analysis aimed to create an ATI-based steatosis grading system. APPROACH AND RESULTS: A systematic review (EMBASE + MEDLINE, 2018-2022) identified studies, including patients with histologically or magnetic resonance imaging proton-density fat fraction (MRI-PDFF)-verified ATI for grading steatosis (S0 to S3). One-stage IPD meta-analyses were conducted using generalized mixed models with a random study-specific intercept. Created ATI-based steatosis grading system (aS0 to aS3) was externally validated on a prospective cohort of patients with type 2 diabetes and metabolic dysfunction-associated steatotic liver disease (n=174, histologically and MRI-PDFF-verified steatosis). Eleven enrolled studies included 1374 patients, classified into S0, S1, S2, and S3 in 45.4%, 35.0%, 9.3%, and 10.3% of the cases. ATI was correlated with histological steatosis ( r = 0.60; 95% CI: 0.52, 0.67; p < 0.001) and MRI-PDFF ( r = 0.70; 95% CI: 0.66, 0.73; p < 0.001) but not with liver stiffness ( r = 0.03; 95% CI: -0.04, 0.11, p = 0.343). Steatosis grade was an independent factor associated with ATI (coefficient: 0.24; 95% CI: [0.22, 0.26]; p < 0.001). ATI marginal means within S0, S1, S2, and S3 subpopulations were 0.59 (95% CI: [0.58, 0.61]), 0.69 (95% CI [0.67, 0.71]), 0.78 (95% CI: [0.76, 0.81]), and 0.85 (95% CI: [0.83, 0.88]) dB/cm/MHz; all contrasts between grades were significant ( p < 0.0001). Three ATI thresholds were calibrated to create a new ATI-based steatosis grading system (aS0 to aS3, cutoffs: 0.66, 0.73, and 0.81 dB/cm/MHz). Its external validation showed Obuchowski measures of 0.84 ± 0.02 and 0.82 ± 0.02 with histologically based and MRI-PDFF-based references. CONCLUSIONS: ATI is a reliable, noninvasive marker of steatosis. This validated ATI-based steatosis grading system could be valuable in assessing patients with metabolic dysfunction-associated steatotic liver disease.

2.
J Hepatol ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38636849

RESUMEN

BACKGROUND & AIMS: Ultrasonography (US) is recommended for HCC surveillance in high-risk patients but has limited performance in detecting early-stage HCC. We aimed to compare the diagnostic performance of biannual US and annual non-contrast abbreviated magnetic resonance imaging (NC-AMRI) as HCC surveillance modalities in high-risk patients. METHODS: This prospective, multicenter cohort study enrolled participants with an estimated annual risk of HCC greater than 5% between October 2015 and April 2017. Participants underwent six rounds of HCC surveillance at 6-month intervals, with both US and NC-AMRI at rounds 1, 3, and 5, and only US at rounds 2, 4, and 6. The sensitivity, diagnostic yield (DY), and false referral rate (FRR) for HCC detection by US and NC-AMRI were compared. RESULTS: In total, 208 participants underwent 980 US and 516 NC-AMRI examinations during 30 months of follow-up. Among them, 34 HCCs were diagnosed in 31 participants, with 20 (64.5%) classified as very early-stage and 11 (35.5%) as early-stage HCC. The sensitivity of annual NC-AMRI (71.0%, 22/31) was marginally higher than that of biannual US (45.2%, 14/31; p = 0.077). NC-AMRI showed a significantly higher DY than US (4.26% vs. 1.43%, p <0.001), with a similar FRR (2.91% vs. 3.06%, p = 0.885). A simulation of alternating US and NC-AMRI at 6-month intervals yielded a sensitivity of 83.9% (26/31), significantly exceeding that of biannual US (p = 0.006). CONCLUSIONS: Annual NC-AMRI showed a marginally higher sensitivity than biannual US for HCC detection in high-risk patients. The DY of annual NC-AMRI was significantly higher than that of biannual US, without increasing the FRR. Thus, alternating US and NC-AMRI at 6-month intervals could be an optimal surveillance strategy for high-risk patients. IMPACT AND IMPLICATIONS: Current guidelines permit the use of magnetic resonance imaging (MRI) as a surveillance tool for hepatocellular carcinoma in patients in whom ultrasonography (US) is inadequate. However, the specific indications, imaging sequences, and intervals for MRI surveillance remain unclear. In our study, we found that annual non-contrast abbreviated MRI exhibited marginally higher sensitivity and significantly better diagnostic yield than biannual US in patients at high risk of hepatocellular carcinoma. Alternating US and non-contrast abbreviated MRI at 6-month intervals led to significantly improved sensitivity compared to biannual US, making it a potentially optimal surveillance strategy for high-risk patients. GOV IDENTIFIER: NCT02551250.

3.
Am J Gastroenterol ; 119(6): 1117-1125, 2024 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-38634559

RESUMEN

INTRODUCTION: Visceral obesity is a risk factor for reflux esophagitis (RE). We investigated the risk of RE according to visceral adipose tissue (VAT) measured by deep neural network architecture using computed tomography (CT) and evaluated the longitudinal association between abdominal adipose tissue changes and the disease course of RE. METHODS: Individuals receiving health checkups who underwent esophagogastroduodenoscopy (EGD) and abdominal CT at Seoul National University Healthcare System Gangnam Center between 2015 and 2016 were included. Visceral and subcutaneous adipose tissue areas and volumes were measured using a deep neural network architecture and CT. The association between the abdominal adipose tissue area and volume and the risk of RE was evaluated. Participants who underwent follow-up EGD and abdominal CT were selected; the effects of changes in abdominal adipose tissue area and volume on RE endoscopic grade were investigated using Cox proportional hazards regression. RESULTS: We enrolled 6,570 patients who underwent EGD and abdominal CT on the same day. RE was associated with male sex, hypertension, diabetes, excessive alcohol intake, current smoking status, and levels of physical activity. The VAT area and volume increased the risk of RE dose-dependently. A decreasing VAT volume was significantly associated with improvement in RE endoscopic grade (hazard ratio: 3.22, 95% confidence interval: 1.82-5.71). Changes in subcutaneous adipose tissue volume and the disease course of RE were not significantly correlated. DISCUSSION: Visceral obesity is strongly associated with RE. VAT volume reduction was prospectively associated with improvement in RE endoscopic grade dose-dependently. Visceral obesity is a potential target for RE treatment.


Asunto(s)
Endoscopía del Sistema Digestivo , Esofagitis Péptica , Grasa Intraabdominal , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Persona de Mediana Edad , Grasa Intraabdominal/diagnóstico por imagen , Grasa Intraabdominal/patología , Esofagitis Péptica/diagnóstico por imagen , Esofagitis Péptica/patología , Endoscopía del Sistema Digestivo/métodos , Factores de Riesgo , Adulto , Obesidad Abdominal/complicaciones , Obesidad Abdominal/diagnóstico por imagen , Redes Neurales de la Computación , Anciano , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
4.
Radiology ; 311(2): e232369, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38805727

RESUMEN

The American College of Radiology Liver Imaging Reporting and Data System (LI-RADS) standardizes the imaging technique, reporting lexicon, disease categorization, and management for patients with or at risk for hepatocellular carcinoma (HCC). LI-RADS encompasses HCC surveillance with US; HCC diagnosis with CT, MRI, or contrast-enhanced US (CEUS); and treatment response assessment (TRA) with CT or MRI. LI-RADS was recently expanded to include CEUS TRA after nonradiation locoregional therapy or surgical resection. This report provides an overview of LI-RADS CEUS Nonradiation TRA v2024, including a lexicon of imaging findings, techniques, and imaging criteria for posttreatment tumor viability assessment. LI-RADS CEUS Nonradiation TRA v2024 takes into consideration differences in the CEUS appearance of viable tumor and posttreatment changes within and in close proximity to a treated lesion. Due to the high sensitivity of CEUS to vascular flow, posttreatment reactive changes commonly manifest as areas of abnormal perilesional enhancement without washout, especially in the first 3 months after treatment. To improve the accuracy of CEUS for nonradiation TRA, different diagnostic criteria are used to evaluate tumor viability within and outside of the treated lesion margin. Broader criteria for intralesional enhancement increase sensitivity for tumor viability detection. Stricter criteria for perilesional enhancement limit miscategorization of posttreatment reactive changes as viable tumor. Finally, the TRA algorithm reconciles intralesional and perilesional tumor viability assessment and assigns a single LI-RADS treatment response (LR-TR) category: LR-TR nonviable, LR-TR equivocal, or LR-TR viable.


Asunto(s)
Carcinoma Hepatocelular , Medios de Contraste , Neoplasias Hepáticas , Ultrasonografía , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Ultrasonografía/métodos , Sistemas de Información Radiológica , Hígado/diagnóstico por imagen , Resultado del Tratamiento
5.
Radiology ; 311(1): e233114, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38563667

RESUMEN

Background Noninvasive diagnostic guidelines for hepatocellular carcinoma (HCC) vary across different global geographic areas, especially regarding criteria about gadoxetic acid-enhanced MRI. Purpose To compare the diagnostic performance of four different international HCC diagnosis guidelines and readers' judgment in diagnosing HCC using gadoxetic acid-enhanced MRI in patients at high risk for HCC. Materials and Methods This retrospective study included patients who had not undergone treatment, were at risk for HCC, and who underwent gadoxetic acid-enhanced MRI from January 2015 to June 2018 from 11 tertiary hospitals in South Korea. Four radiologists independently reviewed focal liver lesions (FLLs) according to four guidelines: American Association for the Study of Liver Diseases (AASLD)/Liver Imaging Reporting and Data System (LI-RADS), Korean Liver Cancer Association-National Cancer Center (KLCA-NCC), European Association for the Study of the Liver (EASL), and Asian Pacific Association for the Study of the Liver (APASL). Reader judgment (HCC or not HCC) was also recorded. Malignant FLLs were confirmed at pathology, and histologic and clinical follow-up data were used for benign FLLs. The guidelines' diagnostic performance was compared using generalized estimating equations. Additionally, the diagnostic odds ratio was assessed. Results A total of 2445 FLLs (median size, 27.4 mm) were analyzed in 2237 patients (mean age, 59 years ± 11 [SD]; 1666 male patients); 69.3% (1694 of 2445) were HCCs. KLCA-NCC showed the highest accuracy (80.0%; 95% CI: 78.7, 81.2; P = .001), with high sensitivity in Eastern guidelines (APASL, 89.1% [95% CI: 87.8, 90.3]; KLCA-NCC, 78.2% [95% CI: 76.6, 79.7]) and high specificity in Western guidelines (AASLD/LI-RADS, 89.6% [95% CI: 87.8, 91.2]; EASL, 88.1% [95% CI: 86.2, 89.9]) (P = .001). The diagnostic odds ratios were 20.7 (95% CI: 17.0, 25.3) for AASLD/LI-RADS, 18.9 (95% CI: 15.8, 22.6) for KLCA-NCC, 16.8 (95% CI: 13.8, 20.4) for EASL, and 8.9 (95% CI: 7.4, 10.7) for APASL. The readers' judgment demonstrated higher accuracy than that of the guidelines (accuracy, 86.0%; 95% CI: 84.9, 86.9; P = .001). Conclusion Among four different international HCC diagnosis guidelines, Eastern guidelines demonstrated higher sensitivity, whereas Western guidelines displayed higher specificity. KLCA-NCC achieved the highest accuracy, and AASLD/LI-RADS exhibited the highest diagnostic odds ratio. © RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Carcinoma Hepatocelular , Gadolinio DTPA , Neoplasias Hepáticas , Humanos , Masculino , Persona de Mediana Edad , Carcinoma Hepatocelular/diagnóstico por imagen , Estudios Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética
6.
Eur Radiol ; 34(7): 4674-4685, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38114846

RESUMEN

OBJECTIVES: To identify MRI features for differentiating type 2 from type 1 intraductal papillary neoplasms of bile duct (IPNB) and assessing malignant potential of IPNB. METHODS: This retrospective study included 60 patients with surgically proven IPNB who had undergone preoperative MRI between January 2007 and December 2020. All surgical specimens were reviewed retrospectively to classify types 1 and 2 IPNBs and assess tumor grade. Significant MRI features for differentiating type 2 (n = 40) from type 1 IPNB (n = 20); and for IPNB with an associated invasive carcinoma (n = 43) from intraepithelial neoplasia (n = 17) were determined using logistic regression analysis. RESULTS: An associated invasive carcinoma was more frequently found in type 2 than in type 1 IPNB (85.0% [34/40] vs. 45.0% [9/20], p = 0.003). At univariable analysis, MRI features including extrahepatic location, no dilatation of tumor-bearing segment of bile duct, isolated upstream bile duct dilatation, and single lesion were associated with type 2 IPNB (all p ≤ 0.012). At multivariable analysis, significant MRI findings for differentiating type 2 from type 1 IPNB were extrahepatic location and no dilatation of tumor-bearing segment of bile duct (odds ratio [OR], 7.24 and 46.40, respectively). At univariable and multivariable analysis, tumor size ≥ 2.5 cm (OR, 8.45), bile duct wall thickening (OR, 4.82), and irregular polypoid or nodular tumor shape (OR, 6.44) were significant MRI features for differentiating IPNB with an associated invasive carcinoma from IPNB with intraepithelial neoplasia. CONCLUSION: MRI with MR cholangiopancreatography may be helpful in differentiating type 2 IPNB from type 1 IPNB and assessing malignant potential of IPNB. CLINICAL RELEVANCE STATEMENT: Preoperative MRI with MR cholangiopancreatography may be helpful in differentiating type 2 intraductal papillary neoplasms of bile duct (IPNB) from type 1 IPNB and assessing malignant potential of IPNB. KEY POINTS: • In terms of tumor grade, the incidence of invasive carcinoma was significantly higher in type 2 intraductal papillary neoplasm of the bile duct (IPNB) than in type 1 IPNB. • At MRI, extrahepatic location and no dilatation of tumor-bearing segment are significant features for differentiating type 2 IPNBs from type 1 IPNBs. • At MRI, large tumor size, bile duct wall thickening, and irregular polypoid or nodular tumor shape are significant features for differentiating IPNB with an associated invasive carcinoma from IPNB with intraepithelial neoplasia.


Asunto(s)
Neoplasias de los Conductos Biliares , Imagen por Resonancia Magnética , Humanos , Masculino , Femenino , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Neoplasias de los Conductos Biliares/diagnóstico por imagen , Neoplasias de los Conductos Biliares/patología , Persona de Mediana Edad , Anciano , Diagnóstico Diferencial , Adulto , Anciano de 80 o más Años
7.
Eur Radiol ; 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38492004

RESUMEN

OBJECTIVE: To investigate whether a deep learning (DL) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE) technique can improve image quality, lesion conspicuity, and lesion detection compared to a standard CAIPIRINHA-VIBE technique in gadoxetic acid-enhanced liver MRI. METHODS: This retrospective single-center study included 168 patients who underwent gadoxetic acid-enhanced liver MRI at 3 T using both standard CAIPIRINHA-VIBE and DL CAIPIRINHA-VIBE techniques on pre-contrast and hepatobiliary phase (HBP) images. Additionally, high-resolution (HR) DL CAIPIRINHA-VIBE was obtained with 1-mm slice thickness on the HBP. Three abdominal radiologists independently assessed the image quality and lesion conspicuity of pre-contrast and HBP images. Statistical analyses involved the Wilcoxon signed-rank test for image quality assessment and the generalized estimation equation for lesion conspicuity and detection evaluation. RESULTS: DL and HR-DL CAIPIRINHA-VIBE demonstrated significantly improved overall image quality and reduced artifacts on pre-contrast and HBP images compared to standard CAIPIRINHA-VIBE (p < 0.001), with a shorter acquisition time (DL vs standard, 11 s vs 17 s). However, the former presented a more synthetic appearance (both p < 0.05). HR-DL CAIPIRINHA-VIBE showed superior lesion conspicuity to standard and DL CAIPIRINHA-VIBE on HBP images (p < 0.001). Moreover, HR-DL CAIPIRINHA-VIBE exhibited a significantly higher detection rate of small (< 2 cm) solid focal liver lesions (FLLs) on HBP images compared to standard CAIPIRINHA-VIBE (92.5% vs 87.4%; odds ratio = 1.83; p = 0.036). CONCLUSION: DL and HR-DL CAIPIRINHA-VIBE achieved superior image quality compared to standard CAIPIRINHA-VIBE. Additionally, HR-DL CAIPIRINHA-VIBE improved the lesion conspicuity and detection of small solid FLLs. DL and HR-DL CAIPIRINHA-VIBE hold the potential clinical utility for gadoxetic acid-enhanced liver MRI. CLINICAL RELEVANCE STATEMENT: DL and HR-DL CAIPIRINHA-VIBE hold promise as potential alternatives to standard CAIPIRINHA-VIBE in routine clinical liver MRI, improving the image quality and lesion conspicuity, enhancing the detection of small (< 2 cm) solid focal liver lesions, and reducing the acquisition time. KEY POINTS: • DL and HR-DL CAIPIRINHA-VIBE demonstrated improved overall image quality and reduced artifacts on pre-contrast and HBP images compared to standard CAIPIRINHA-VIBE, in addition to a shorter acquisition time. • DL and HR-DL CAIPIRINHA-VIBE yielded a more synthetic appearance than standard CAIPIRINHA-VIBE. • HR-DL CAIPIRINHA-VIBE showed improved lesion conspicuity than standard CAIPIRINHA-VIBE on HBP images, with a higher detection of small (< 2 cm) solid focal liver lesions.

8.
Eur Radiol ; 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39028376

RESUMEN

OBJECTIVES: This study aimed to evaluate the potential of deep learning (DL)-assisted automated three-dimensional quantitative tumor burden at MRI to predict postoperative early recurrence (ER) of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: This was a single-center retrospective study enrolling patients who underwent resection for BCLC A and B HCC and preoperative contrast-enhanced MRI. Quantitative total tumor volume (cm3) and total tumor burden (TTB, %) were obtained using a DL automated segmentation tool. Radiologists' visual assessment was used to ensure the quality control of automated segmentation. The prognostic value of clinicopathological variables and tumor burden-related parameters for ER was determined by Cox regression analyses. RESULTS: A total of 592 patients were included, with 525 and 67 patients assigned to BCLC A and B, respectively (2-year ER rate: 30.0% vs. 45.3%; hazard ratio (HR) = 1.8; p = 0.007). TTB was the most important predictor of ER (HR = 2.2; p < 0.001). Using 6.84% as the threshold of TTB, two ER risk strata were obtained in overall (p < 0.001), BCLC A (p < 0.001), and BCLC B (p = 0.027) patients, respectively. The BCLC B low-TTB patients had a similar risk for ER to BCLC A patients and thus were reassigned to a BCLC An stage; whilst the BCLC B high-TTB patients remained in a BCLC Bn stage. The 2-year ER rate was 30.5% for BCLC An patients vs. 58.1% for BCLC Bn patients (HR = 2.8; p < 0.001). CONCLUSIONS: TTB determined by DL-based automated segmentation at MRI was a predictive biomarker for postoperative ER and facilitated refined subcategorization of patients within BCLC stages A and B. CLINICAL RELEVANCE STATEMENT: Total tumor burden derived by deep learning-based automated segmentation at MRI may serve as an imaging biomarker for predicting early recurrence, thereby improving subclassification of Barcelona Clinic Liver Cancer A and B hepatocellular carcinoma patients after hepatectomy. KEY POINTS: Total tumor burden (TTB) is important for Barcelona Clinic Liver Cancer (BCLC) staging, but is heterogenous. TTB derived by deep learning-based automated segmentation was predictive of postoperative early recurrence. Incorporating TTB into the BCLC algorithm resulted in successful subcategorization of BCLC A and B patients.

9.
BMC Gastroenterol ; 24(1): 280, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39169297

RESUMEN

Radiofrequency ablation (RFA) offers a minimally invasive treatment for small hepatocellular carcinoma (HCC), but it faces challenges such as high local recurrence rates. This prospective study, conducted from January 2020 to July 2022, evaluated a novel approach using a three-channel, dual radiofrequency (RF) generator with separable clustered electrodes to improve RFA's efficacy and safety. The study employed a high-power, gradual, stepwise RFA method on HCCs (≤ 4 cm), utilizing real-time ultrasound-computed tomography (CT)/magnetic resonance imaging (MRI) fusion imaging. Involving 110 participants with 116 HCCs, the study reported no major complications. Local tumor progression (LTP) and intrahepatic remote recurrence (IRR) rates were low, with promising cumulative incidences at 1, 2, and 3 years for LTP (0.9%, 3.6%, 7.0%) and IRR (13.9%, 20.5%, 31.4%). Recurrence-free survival (RFS) rates were similarly encouraging: LTP (99.1%, 96.4%, 93.0%) and IRR (86.1%, 79.5%, 68.6%). This innovative gradual, incremental high-power RFA technique, featuring a dual switching monopolar mode and three electrodes, represents an effective and safer management option for small HCCs. TRIAL REGISTRATION: clinicaltrial.gov identifier: NCT05397860, first registered on 26/05/2022.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Recurrencia Local de Neoplasia , Ablación por Radiofrecuencia , Humanos , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/diagnóstico por imagen , Estudios Prospectivos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Ablación por Radiofrecuencia/métodos , Electrodos , Imagen por Resonancia Magnética , Adulto , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Progresión de la Enfermedad , Anciano de 80 o más Años , Ablación por Catéter/métodos
10.
Mar Drugs ; 22(2)2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38393062

RESUMEN

The present study aims to explore the probable anti-adipogenesis effect of Dictyopteris divaricata (D. divaricata) in 3T3-L1 preadipocytes by regulating heme oxygenase-1 (HO-1). The extract of D. divaricata retarded lipid accretion and decreased triglyceride (TG) content in 3T3-L1 adipocytes but increased free glycerol levels. Treatment with the extract inhibited lipogenesis by inhibiting protein expressions of fatty acid synthase (FAS) and lipoprotein lipase (LPL), whereas lipolysis increased by activating phosphorylation of hormone-sensitive lipase (p-HSL) and AMP-activated protein kinase (p-AMPK). The extract inhibited adipocyte differentiation of 3T3-L1 preadipocytes through down-regulating adipogenic transcription factors, including peroxisome proliferator-activated receptor gamma (PPARγ) and CCAAT/enhancer-binding protein α (C/EBPα), and sterol regulatory element-binding protein 1 (SREBP1). This is attributed to the triggering of Wnt/ß-catenin signaling. In addition, this study found that treatment with the extract activated HO-1 expression. Pharmacological approaches revealed that treatment with Zinc Protoporphyrin (ZnPP), an HO-1 inhibitor, resulted in an increase in lipid accumulation and a decrease in free glycerol levels. Finally, three adipogenic transcription factors, such as PPARγ, C/EBPα, and SREBP1, restored their expression in the presence of ZnPP. Analysis of chemical constituents revealed that the extract of D. divaricata is rich in 1,4-benzenediol, 7-tetradecenal, fucosterol, and n-hexadecanoic acid, which are known to have multiple pharmacological properties.


Asunto(s)
Adipogénesis , Phaeophyceae , Animales , Ratones , Lipólisis , Células 3T3-L1 , Hemo-Oxigenasa 1/metabolismo , PPAR gamma/metabolismo , Glicerol/farmacología , Glicerol/metabolismo , Diferenciación Celular , Adipocitos , Proteína alfa Potenciadora de Unión a CCAAT , Factores de Transcripción/metabolismo , Lípidos/farmacología
13.
Insights Imaging ; 15(1): 46, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38353856

RESUMEN

OBJECTIVES: To evaluate the inter-platform reproducibility of ultrasound-based fat fraction examination in nonalcoholic fatty liver disease (NAFLD). METHODS: Patients suspected of having NAFLD were prospectively enrolled from January 2023. Ultrasound-based fat fraction examinations were performed using two different platforms (ultrasound-derived fat fraction [UDFF] and quantitative ultrasound-derived estimated fat fraction [USFF]) on the same day. The correlation between UDFF and USFF was assessed using Pearson correlation coefficient. Intraclass correlation coefficient (ICC), Bland-Altman analysis with 95% limits of agreement (LOAs), and the coefficient of variation (CV) were used to assess inter-platform reproducibility. RESULTS: A total of 41 patients (21 men and 20 women; mean age, 53.9 ± 12.6 years) were analyzed. Moderate correlation was observed between UDFF and USFF (Pearson's r = 0.748; 95% confidence interval [CI]: 0.572-0.858). On Bland-Altman analysis, the mean difference between UDFF and USFF values was 1.3% with 95% LOAs ranging from -8.0 to 10.6%. The ICC between UDFF and USFF was 0.842 (95% CI: 0.703-0.916), with a CV of 29.9%. CONCLUSION: Substantial inter-platform variability was observed among different ultrasound-based fat fraction examinations. Therefore, it is not appropriate to use ultrasound-based fat fraction values obtained from different vendors interchangeably. CRITICAL RELEVANCE STATEMENT: Considering the substantial inter-platform variability in ultrasound-based fat fraction assessments, caution is imperative when interpreting and comparing fat fraction values obtained from different ultrasound platforms in clinical practice. KEY POINTS: • Inter-platform reproducibility of ultrasound-based fat fraction examinations is important for its clinical application. • Significant variability across different ultrasound-based fat fraction examinations was observed. • Using ultrasound-based fat fraction values from different vendors interchangeably is not advisable.

14.
Pharmaceutics ; 16(2)2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38399334

RESUMEN

The aim of this study was to predict the cytochrome P450 3A (CYP3A)-mediated drug-drug interactions (DDIs) between saxagliptin and nicardipine using a physiologically based pharmacokinetic (PBPK) model. Initially, in silico and in vitro parameters were gathered from experiments or the literature to construct PBPK models for each drug in rats. These models were integrated to predict the DDIs between saxagliptin, metabolized via CYP3A2, and nicardipine, exhibiting CYP3A inhibitory activity. The rat DDI PBPK model was completed by optimizing parameters using experimental rat plasma concentrations after co-administration of both drugs. Following co-administration in Sprague-Dawley rats, saxagliptin plasma concentration significantly increased, resulting in a 2.60-fold rise in AUC, accurately predicted by the rat PBPK model. Subsequently, the workflow of the rat PBPK model was applied to humans, creating a model capable of predicting DDIs between the two drugs in humans. Simulation from the human PBPK model indicated that nicardipine co-administration in humans resulted in a nearly unchanged AUC of saxagliptin, with an approximate 1.05-fold change, indicating no clinically significant changes and revealing a lack of direct translation of animal interaction results to humans. The animal-to-human PBPK model extrapolation used in this study could enhance the reliability of predicting drug interactions in clinical settings where DDI studies are challenging.

15.
J Liver Cancer ; 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38853440

RESUMEN

Background/Aims: This study explored the initial institutional experience of using gold fiducial markers for stereotactic body radiotherapy (SBRT) in treating malignant hepatic tumors using real-time ultrasound-computed tomography (CT)/magnetic resonance (MR) imaging fusion-guided percutaneous placement. Methods: From May 2021 to August 2023, 19 patients with 25 liver tumors that were invisible on pre-contrast CT received fiducial markers following these guidelines. Postprocedural scans were used to confirm their placement. We assessed technical and clinical success rates and monitored complications. The implantation of fiducial markers facilitating adequate treatment prior to SBRT, which was achieved in 96% of the cases (24 of 25 tumors), was considered technical success. Clinical success was the successful completion of SBRT without evidence of marker displacement and was achieved in 88% of cases (22 of 25 tumors). Complications included one major subcapsular hematoma and marker migration into the right atrium in two cases, which prevented SBRT. Results: Among the treated tumors, 83.3% (20 of 24) showed a complete response, 12.5% (3 of 24) remained stable, and 4.2% (1 of 24) progressed during an average 11.7-month follow-up (range, 2-32 months). Conclusions: This study confirms that percutaneous gold fiducial marker placement using real-time CT/MR guidance is effective and safe for SBRT in hepatic tumors, but warns of marker migration risks, especially near the hepatic veins and in subcapsular locations. Using fewer markers than traditionally recommended-typically two per patient), the outcomes were still satisfactory, particularly given the increased risk of migration when markers were placed near major hepatic veins.

16.
Forensic Sci Int Genet ; 68: 102940, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37857127

RESUMEN

Since DNA methylation at specific CpG sites exhibits a strong age association, researchers have developed numerous age prediction models based on the methylation BeadChip array. These models harness epigenetic clocks that hold the potential to narrow down the search range for unknown suspects and unidentified victims. This study collected 180 post-mortem tissue samples comprising nine tissue types (blood, brain, heart, lung, liver, kidney, muscle, epidermis, and dermis) from autopsies of 20 Koreans aged 18-78. Subsequently, DNA methylation profiling was conducted using the Infinium MethylationEPIC array. We tested several array-based age prediction models using the data obtained from various tissues. The pan-tissue clock exhibited a moderately accurate prediction across all nine tissue types (MAE = 8.7 years, r = 0.88). Notably, the DNAm ages of the Hannum clock, the skin & blood clock, and the Zhang clock strongly correlated with the actual age in blood samples (MAE < approximately 5 years, r > 0.9). PhenoAge yielded an MAE of 10.1 years and an r-value of 0.92. The muscle-specific epigenetic clock, the MEAT package, demonstrated high prediction accuracy in muscle samples (MAE = 4.7 years, r = 0.93). Those previously reported array-based age prediction models were mainly constructed in Europeans but performed well in Koreans. In addition, tests involving various quantities of DNA and fragmented DNA have shown that DNA quantity and quality affected methylation measurements and age prediction results. However, robust age prediction models exist under low amounts of DNA and fragmented DNA conditions.


Asunto(s)
Metilación de ADN , ADN , Humanos , Islas de CpG , Epigenómica , Epigénesis Genética
17.
Cancer Imaging ; 24(1): 4, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38172949

RESUMEN

BACKGROUND: Percutaneous radiofrequency ablation (RFA) is pivotal for treating small malignant liver tumors, but tumors often remain inconspicuous on B-mode ultrasound (US). This study evaluates the potential of CEUS-CT/MRI fusion imaging (FI) to improve tumor visibility and the associated RFA outcomes for small (≤ 3 cm) malignant liver tumors that were inconspicuous on US. METHODS: Between January 2019 and April 2021, a prospective study enrolled 248 patients with liver malignancies (≤ 3 cm) that were poorly visible on B-mode US. Tumor visibility and ablation feasibility were assessed using B-mode US, US-CT/MRI FI, and CEUS-CT/MRI FI, and graded on a 4-point scale. CEUS was employed post-registration of US and CT/MRI images, utilizing either SonoVue or Sonazoid. Comparisons between US-based and CEUS-based fusion visibility and feasibility scores were undertaken using the Friedman test. Moreover, rates of technical success, technique efficacy, local tumor progression (LTP), and major complications were assessed. RESULTS: The cohort included 223 hepatocellular carcinomas (HCCs) (89.9%) and 23 metastases (9.3%), with an average tumor size of 1.6 cm. CEUS-CT/MRI FI demonstrated a significant advantage in tumor visibility (3.4 ± 0.7 vs. 1.9 ± 0.6, P < 0.001) and technical feasibility (3.6 ± 0.6 vs. 2.9 ± 0.8, P < 0.001) compared to US-FI. In 85.5% of patients, CEUS addition to US-FI ameliorated tumor visibility. Technical success was achieved in 99.6% of cases. No severe complications were reported. One and two-year post CEUS-CT/MRI FI-guided RFA estimates for LTP were 9.3% and 10.9%, respectively. CONCLUSIONS: CEUS-CT/MRI FI significantly improves the visualization of tumors not discernible on B-mode US, thus augmenting percutaneous RFA success and delivering improved therapeutic outcomes. TRIAL REGISTRATION: ClinicalTrials.gov, NCT05445973. Registered 17 June 2022 - Retrospectively registered, http://clinicaltrials.gov/study/NCT05445973?id=NCT05445973&rank=1 .


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/patología , Ablación por Catéter/métodos , Medios de Contraste , Estudios de Factibilidad , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento , Ultrasonografía/métodos
18.
Radiol Artif Intell ; 6(2): e230192, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38231025

RESUMEN

Purpose To compare the image quality and diagnostic capability in detecting malignant liver tumors of low-dose CT (LDCT, 33% dose) with deep learning-based denoising (DLD) and standard-dose CT (SDCT, 100% dose) with model-based iterative reconstruction (MBIR). Materials and Methods In this prospective, multicenter, noninferiority study, individuals referred for liver CT scans were enrolled from three tertiary referral hospitals between February 2021 and August 2022. All liver CT scans were conducted using a dual-source scanner with the dose split into tubes A (67% dose) and B (33% dose). Blended images from tubes A and B were created using MBIR to produce SDCT images, whereas LDCT images used data from tube B and were reconstructed with DLD. The noise in liver images was measured and compared between imaging techniques. The diagnostic performance of each technique in detecting malignant liver tumors was evaluated by three independent radiologists using jackknife alternative free-response receiver operating characteristic analysis. Noninferiority of LDCT compared with SDCT was declared when the lower limit of the 95% CI for the difference in figure of merit (FOM) was greater than -0.10. Results A total of 296 participants (196 men, 100 women; mean age, 60.5 years ± 13.3 [SD]) were included. The mean noise level in the liver was significantly lower for LDCT (10.1) compared with SDCT (10.7) (P < .001). Diagnostic performance was assessed in 246 participants (108 malignant tumors in 90 participants). The reader-averaged FOM was 0.880 for SDCT and 0.875 for LDCT (P = .35). The difference fell within the noninferiority margin (difference, -0.005 [95% CI: -0.024, 0.012]). Conclusion Compared with SDCT with MBIR, LDCT using 33% of the standard radiation dose had reduced image noise and comparable diagnostic performance in detecting malignant liver tumors. Keywords: CT, Abdomen/GI, Liver, Comparative Studies, Diagnosis, Reconstruction Algorithms Clinical trial registration no. NCT05804799 © RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Carcinoma Hepatocelular , Aprendizaje Profundo , Neoplasias Hepáticas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Abdomen , Estudios Prospectivos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Anciano
19.
ACS Appl Mater Interfaces ; 16(28): 37157-37166, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-38950350

RESUMEN

Area-selective atomic layer deposition (AS-ALD), which provides a bottom-up nanofabrication method with atomic-scale precision, has attracted a great deal of attention as a means to alleviate the problems associated with conventional top-down patterning. In this study, we report a methodology for achieving selective deposition of high-k dielectrics by surface modification through vapor-phase functionalization of octadecylphosphonic acid (ODPA) inhibitor molecules accompanied by post-surface treatment. A comparative evaluation of deposition selectivity of ZrO2 thin films deposited with the O2 and O3 reactants was performed on SiO2, TiN, and W substrates, and we confirmed that high enough deposition selectivity over 10 nm can be achieved even after 200 cycles of ALD with the O2 reactant. Subsequently, the electrical properties of ZrO2 films deposited with O2 and O3 reactants were investigated with and without post-deposition treatment. We successfully demonstrated that high-quality ZrO2 thin films with high dielectric constants and stable antiferroelectric properties can be produced by subjecting the films to ozone, which can eliminate carbon impurities within the films. We believe that this work provides a new strategy to achieve highly selective deposition for AS-ALD of dielectric on dielectric (DoD) applications toward upcoming bottom-up nanofabrication.

20.
Nat Commun ; 15(1): 5450, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38982039

RESUMEN

Cultured meat is emerging as a new type of food that can provide animal protein in a sustainable way. Many previous studies employed various types of scaffolds to develop cultured meat with similar properties to slaughtered meat. However, important properties such as flavor were not discussed, even though they determine the quality of food. Flavor characteristics vary dramatically depending on the amount and types of amino acids and sugars that produce volatile compounds through the Maillard reaction upon cooking. In this study, a flavor-switchable scaffold is developed to release meaty flavor compounds only upon cooking temperature mimicking the Maillard reaction of slaughtered meat. By introducing a switchable flavor compound (SFC) into a gelatin-based hydrogel, we fabricate a functional scaffold that can enhance the aromatic properties of cultured meat. The temperature-responsive SFC stably remains in the scaffold during the cell culture period and can be released at the cooking temperature. Surprisingly, cultured meat fabricated with this flavor-switchable scaffold exhibits a flavor pattern similar to that of beef. This research suggests a strategy to develop cultured meat with enhanced sensorial characteristics by developing a functional scaffold which can mimic the natural cooking flavors of conventional meat.


Asunto(s)
Culinaria , Aromatizantes , Reacción de Maillard , Carne , Animales , Carne/análisis , Aromatizantes/química , Gusto , Bovinos , Hidrogeles/química , Humanos , Andamios del Tejido/química , Temperatura , Gelatina/química , Carne in Vitro
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda