Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Appl Opt ; 56(14): 4039-4044, 2017 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-29047528

RESUMEN

In this paper, we propose a novel wavelength demultiplexer based on metal-insulator-metal plasmonic waveguides with a nanoscale ring resonator. Its transmission characteristics are numerically studied using finite element method (FEM) simulations, and the eigenwavelengths of the ring resonator are theoretically calculated. For the proposed structure, we found that the ratio of the orders of resonant transmittance peaks for two different high-order modes of the ring resonator is close to the ratio of the two communication wavelengths 1310 and 1550 nm. These resonance wavelengths of the demultiplexer are effortlessly tuned by varying the refractive index of the material in the ring resonator and the geometrical parameters of the structure. The results simulated by FEM agree well with those from the resonant theory of the ring resonator. The presented structures will have significant potential applications in highly integrated plasmonic devices.

2.
Sensors (Basel) ; 17(2)2017 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-28165412

RESUMEN

Calorimetric biochemical measurements offer various advantages such as low waste, low cost, low sample consumption, short operating time, and labor-savings. Multichannel calorimeters can enhance the possibility of performing higher-throughput biochemical measurements. An enthalpy sensor (ES) array is a key device in multichannel calorimeters. Most ES arrays use Wheatstone bridge amplifiers to condition the sensor signals, but such an approach is only suitable for null detection and low resistance sensors. To overcome these limitations, we have developed a multichannel calorimetric simultaneous assay (MCSA) platform. An adjustable microampere constant-current (AMCC) source was designed for exciting the ES array using a microampere current loop measurement circuit topology. The MCSA platform comprises a measurement unit, which contains a multichannel calorimeter and an automatic simultaneous injector, and a signal processing unit, which contains multiple ES signal conditioners and a data processor. This study focused on the construction of the MCSA platform; in particular, construction of the measurement circuit and calorimeter array in a single block. The performance of the platform, including current stability, temperature sensitivity and heat sensitivity, was evaluated. The sensor response time and calorimeter constants were given. The capability of the platform to detect relative enzyme activity was also demonstrated. The experimental results show that the proposed MCSA is a flexible and powerful biochemical measurement device with higher throughput than existing alternatives.

3.
Foods ; 8(8)2019 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-31382515

RESUMEN

The aim of this study was to investigate the suitability of electrical impedance spectroscopy (EIS) as a nondestructive quality monitoring tool of aged beef, focusing on the development of accurate electrical indexes. The relationship between the electrical indexes derived from the impedance ratio (IR) or admittance was established. Quality parameters such as the drip loss, cooking loss, water-holding capacity, and shear force of beef loin wet-aged for 0 to 21 days were evaluated to develop the new electrical indexes. In addition, the predictive capability of EIS was trialed using different indexes and frequencies. This study revealed that the most appropriate choice is to use electrical parameters at a lower frequency to determine or predict the physical properties of aged beef. The IR was derived from the ratio between the electrical impedance measured parallel to and perpendicular to the muscle fibers in the low-frequency domain. Furthermore, the degradation of muscle fibers was observed by optical microscopy. The investigated electrical indexes had higher correlations with shear force (0.52 ≤ R2 ≤ 0.58) compared to correlations with aging days (0.34 ≤ R2 ≤ 0.39). The findings of the study could be used for meat quality inspection in slaughterhouses as well as during aging.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda