Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Phys Rev Lett ; 124(15): 156801, 2020 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-32357056

RESUMEN

We report on detailed experimental studies of a high-quality heterojunction insulated-gate field-effect transistor (HIGFET) to probe the particle-hole symmetry of the fractional quantum Hall effect (FQHE) states about half-filling in the lowest Landau level. The HIGFET is specially designed to vary the density of a two-dimensional electronic system under constant magnetic fields. We find in our constant magnetic field, variable density measurements that the sequence of FQHE states at filling factors ν=1/3,2/5,3/7… and its particle-hole conjugate states at filling factors 1-ν=2/3,3/5,4/7… have a very similar energy gap. Moreover, a reflection symmetry can be established in the magnetoconductivities between the ν and 1-ν states about half-filling. Our results demonstrate that the FQHE states in the lowest Landau level are manifestly particle-hole symmetric.

2.
Nanotechnology ; 26(8): 085701, 2015 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-25649193

RESUMEN

We show that a scanning capacitance microscope (SCM) can image buried delta-doped donor nanostructures fabricated in Si via a recently developed atomic-precision scanning tunneling microscopy (STM) lithography technique. A critical challenge in completing atomic-precision nanoelectronic devices is to accurately align mesoscopic metal contacts to the STM defined nanostructures. Utilizing the SCMs ability to image buried dopant nanostructures, we have developed a technique by which we are able to position metal electrodes on the surface to form contacts to underlying STM fabricated donor nanostructures with a measured accuracy of 300 nm. Low temperature (T = 4 K) transport measurements confirm successful placement of the contacts to the donor nanostructures.

3.
Nanotechnology ; 26(20): 205703, 2015 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-25927489

RESUMEN

We present transport measurements of silicon MOS split gate structures with and without Sb implants. We observe classical point contact (PC) behavior that is free of any pronounced unintentional resonances at liquid He temperatures. The implanted device has resonances superposed on the PC transport indicative of transport through the Sb donors. We fit the differential conductance to a rectangular tunnel barrier model with a linear barrier height dependence on source-drain voltage and non-linear dependence on gate bias. Effects such as Fowler-Nordheim (FN) tunneling and image charge barrier lowering (ICBL) are considered. Barrier heights and widths are estimated for the entire range of relevant biases. The barrier heights at the locations of some of the resonances for the implanted tunnel barrier are between 15-20 meV, which are consistent with transport through shallow partially hybridized Sb donors. The dependence of width and barrier height on gate voltage is found to be linear over a wide range of gate bias in the split gate geometry but deviates considerably when the barrier becomes large and is not described completely by standard 1D models such as FN or ICBL effects.

4.
Nat Commun ; 14(1): 3906, 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37400458

RESUMEN

We report low-temperature electronic transport measurements performed in two multi-terminal Corbino samples formed in GaAs/Al-GaAs two-dimensional electron gases (2DEG) with both ultra-high electron mobility ( ≳ 20 × 106 cm2/ Vs) and with distinct electron density of 1.7 and 3.6 × 1011 cm-2. In both Corbino samples, a non-monotonic behavior is observed in the temperature dependence of the resistance below 1 K. Surprisingly, a sharp decrease in resistance is observed with increasing temperature in the sample with lower electron density, whereas an opposite behavior is observed in the sample with higher density. To investigate further, transport measurements were performed in large van der Pauw samples having identical heterostructures, and as expected they exhibit resistivity that is monotonic with temperature. Finally, we discuss the results in terms of various lengthscales leading to ballistic and hydrodynamic electronic transport, as well as a possible Gurzhi effect.

5.
Phys Rev Lett ; 109(24): 246603, 2012 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-23368357

RESUMEN

We use phase-resolved transient grating spectroscopy to measure the propagation of spin helices in a high mobility n-GaAs/AlGaAs quantum well with an applied in-plane electric field. At relatively low fields helical modes crossover from overdamped excitations where the spin-precession period exceeds the spin lifetime, to a regime of coherent propagation where several spin-precession periods can be observed. We demonstrate that the envelope of a spin polarization packet reaches a current-driven velocity of 10(7) cm s(-1) in an applied field of 70 V cm(-1).

6.
Phys Rev Lett ; 106(24): 247401, 2011 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-21770596

RESUMEN

We use phase-resolved transient grating spectroscopy to measure the drift and diffusion of electron-hole density waves in a semiconductor quantum well. The unique aspects of this optical probe allow us to determine the frictional force between a two-dimensional Fermi liquid of electrons and a dilute gas of holes. Knowledge of electron-hole friction enables prediction of ambipolar dynamics in high-mobility electron systems.

7.
Sci Rep ; 9(1): 16976, 2019 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-31740683

RESUMEN

High-fidelity single-shot readout of spin qubits requires distinguishing states much faster than the T1 time of the spin state. One approach to improving readout fidelity and bandwidth (BW) is cryogenic amplification, where the signal from the qubit is amplified before noise sources are introduced and room-temperature amplifiers can operate at lower gain and higher BW. We compare the performance of two cryogenic amplification circuits: a current-biased heterojunction bipolar transistor circuit (CB-HBT), and an AC-coupled HBT circuit (AC-HBT). Both circuits are mounted on the mixing-chamber stage of a dilution refrigerator and are connected to silicon metal oxide semiconductor (Si-MOS) quantum dot devices on a printed circuit board (PCB). The power dissipated by the CB-HBT ranges from 0.1 to 1 µW whereas the power of the AC-HBT ranges from 1 to 20 µW. Referred to the input, the noise spectral density is low for both circuits, in the 15 to 30 fA/[Formula: see text] range. The charge sensitivity for the CB-HBT and AC-HBT is 330 µe/[Formula: see text] and 400 µe/[Formula: see text], respectively. For the single-shot readout performed, less than 10 µs is required for both circuits to achieve bit error rates below 10-3, which is a putative threshold for quantum error correction.

8.
Rev Sci Instrum ; 88(12): 123301, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29289172

RESUMEN

We demonstrate a capability of deterministic doping at the single atom level using a combination of direct write focused ion beam and solid-state ion detectors. The focused ion beam system can position a single ion to within 35 nm of a targeted location and the detection system is sensitive to single low energy heavy ions. This platform can be used to deterministically fabricate single atom devices in materials where the nanostructure and ion detectors can be integrated, including donor-based qubits in Si and color centers in diamond.

9.
Endocrinology ; 111(6): 1917-24, 1982 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-7140640

RESUMEN

Adrenal secretory rates of catecholamines in response to a repeated stimulus have not been described. We have used repeated small hemorrhages spaced 24 h apart in pentobarbital anesthetized dogs prepared with a chronic adrenal venous catheter to study this question. Our results confirm earlier reports that an initial 7.5 ml/kg hemorrhage is a mild stimulus to the adrenal medullar secretion of epinephrine and norepinephrine, However, when this stimulus is repeated 24 h later, a greatly potentiated secretory response of both hormones is seen. Cardiovascular changes after hemorrhage did not differ on the 2 days. Repeated 3.75 ml/kg hemorrhages did not lead to augmented adrenal medullary secretion of catecholamines on day 2. These data indicate that there is a factor associated with hemorrhage that potentiates the adrenal medullary response to second small hemorrhage. This factor appears to be subject to a threshold that lies between a 3.75 and 7.5 ml/kg hemorrhage. A significant catecholamine response on day 1 was not essential for the potentiated response on day 2. Thus, this phenomenon does not appear to be the result of adrenal enzyme induction as a consequence of prior adrenal medullary stimulation.


Asunto(s)
Médula Suprarrenal/fisiopatología , Hemorragia/fisiopatología , Enfermedades de las Glándulas Suprarrenales/fisiopatología , Animales , Presión Sanguínea , Perros , Epinefrina/metabolismo , Femenino , Frecuencia Cardíaca , Masculino , Norepinefrina/metabolismo , Factores de Tiempo
10.
Endocrinology ; 117(3): 1000-10, 1985 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-2990864

RESUMEN

To test whether or not adrenal sympathetic innervation is required for the adrenocortical response to small hemorrhage, awake dogs were studied after unilateral adrenal sympathetic denervation. Bilateral adrenal vein cannulas were placed chronically to permit measurement of cortisol, epinephrine, and norepinephrine secretion rates and adrenal blood flow simultaneously from the intact and the denervated adrenal. Plasma ACTH concentration was measured and the presentation rate of ACTH was calculated as the product of plasma ACTH concentration and adrenal plasma flow. Unilateral isolation of the sympathetic chain from the spinal cord at thoracic levels 9-12 (T9-12) had no effect on adrenal blood flow, on the presentation rate of ACTH, or on cortisol secretion after 10 mg/kg hemorrhage. However, thoracic levels 9-12 denervation prevented the secretory response of catecholamines to hemorrhage without lowering basal catecholamine secretion. Unilateral splanchnicotomy, the sectioning of the thoracic and upper lumbar splanchnic nerves, reduced adrenal blood flow and the presentation rate of ACTH, suppressed basal catecholamine secretion, and prevented the catecholamine response to hemorrhage. However, there was no reduction in the secretory response of cortisol to 10% or 20% hemorrhage. These findings suggest that in the absence of sympathetic innervation to the adrenal, increases in adrenal sensitivity to ACTH occur to offset decreased ACTH presentation rate resulting in a normal cortisol response to hemorrhage. However, adrenal sensitivity to exogenous ACTH was not increased in non-hemorrhaged dogs after unilateral splanchnicotomy. Thus, hemorrhage must activate a non-ACTH mechanism that is independent of sympathetic adrenal innervation to augment adrenal sensitivity to ACTH. Sympathetic innervation to the adrenal has profound effects on catecholamine secretion and on adrenal blood flow but is not required for the secretory response of cortisol to small hemorrhage.


Asunto(s)
Enfermedades de las Glándulas Suprarrenales/fisiopatología , Glándulas Suprarrenales/irrigación sanguínea , Hemorragia/fisiopatología , Hidrocortisona/sangre , Sistema Nervioso Simpático/fisiología , Glándulas Suprarrenales/inervación , Hormona Adrenocorticotrópica/sangre , Hormona Adrenocorticotrópica/farmacología , Animales , Presión Sanguínea , Desnervación , Perros , Epinefrina/metabolismo , Femenino , Frecuencia Cardíaca , Masculino , Norepinefrina/metabolismo , Flujo Sanguíneo Regional/efectos de los fármacos , Circulación Esplácnica
11.
Endocrinology ; 112(2): 681-8, 1983 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-6293808

RESUMEN

We used two sequential 7.5 ml/kg hemorrhages, spaced 24 h apart, in the chronically prepared, pentobarbital-anesthetized dog to study the effects of repeated stimuli on the adrenocortical system. Adrenal secretion of cortisol, peripheral cortisol, and ACTH were measured. All three variables increased after an initial 7.5 ml/kg hemorrhage. When the hemorrhage was repeated 24 h later, the secretory response of cortisol began more rapidly (by 4 min), reached a higher peak, and was more prolonged than the response on day 1. ACTH rose to significantly higher values than on day 1, but only after 8 min. There was no differences in cardiovascular variables after hemorrhage on the 2 days. A repeated 3.75 ml/kg hemorrhage did not lead to a potentiated response. These results confirm reports that after physiological stimulation, changes occur in the pituitary-adrenal system that may lead to a potentiated response to later stimuli. The mechanism of these changes is unknown, but our results suggest that both an increase in circulating ACTH and a change in adrenal sensitivity to ACTH may be involved.


Asunto(s)
Corteza Suprarrenal/fisiopatología , Hemorragia/fisiopatología , Hidrocortisona/metabolismo , Hormona Adrenocorticotrópica/sangre , Animales , Glucemia/análisis , Presión Sanguínea , Temperatura Corporal , Perros , Frecuencia Cardíaca , Factores de Tiempo
12.
J Endocrinol ; 167(2): 205-17, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11054634

RESUMEN

We determined how changes in the responsiveness of the hypothalamo-pituitary-adrenal (HPA) system that accompany experimentation affect facilitation of HPA responses to hemorrhage. Hemorrhage (10 ml/kg over 3 min) was performed in conscious, chronically prepared rats. Blood was sampled over 1 h followed by reinfusion of shed blood. Hemorrhage was performed either once or twice separated by 24 h in different groups of animals. To test the effect of the circadian variation in responsiveness, rats were hemorrhaged on days 4 and 5 after surgery either in the morning (AM) or in the afternoon (PM). The response of ACTH to hemorrhage on day 4 was greater in the PM than in the AM (P<0.01). The ACTH response to the second hemorrhage on day 5 was greater than that to hemorrhage on day 4 only in the AM group (P<0.01). Thus, facilitation of ACTH responses by prior hemorrhage was evident only in the AM. To determine the effects of surgical recovery, additional experiments were done in the AM either early (days 3 and 4) or later (days 6 and 7) after surgery. In these experiments, hemorrhage was performed in all rats on days 4 and 7 and either hemorrhage or blood sampling alone was performed on day 3 and 6. ACTH did not increase in rats with sampling and no hemorrhage. ACTH increased more after an initial hemorrhage on day 3 than on day 6 (P<0.01). ACTH response to hemorrhage on day 4 was greater when preceded by hemorrhage vs sampling on day 3 (P<0.01). ACTH response to hemorrhage in rats bled twice did not differ on day 3 and day 4. On day 7, the response of ACTH in rats that had hemorrhage on day 6 was greater than both their own response on day 6 and the response of a control group with sampling on day 6 (P<0.01). These results demonstrate potentiation of ACTH responses to hemorrhage by an earlier similar hemorrhage, but clearly indicate that enhanced sensitivity of the HPA to hemorrhage either by circadian factors or by surgery can mask this effect.


Asunto(s)
Hormona Adrenocorticotrópica/sangre , Ritmo Circadiano/fisiología , Hemorragia Posoperatoria/fisiopatología , Animales , Presión Sanguínea/fisiología , Corticosterona/sangre , Frecuencia Cardíaca/fisiología , Sistema Hipotálamo-Hipofisario/fisiopatología , Masculino , Sistema Hipófiso-Suprarrenal/fisiopatología , Hemorragia Posoperatoria/sangre , Periodo Posoperatorio , Ratas , Ratas Sprague-Dawley , Recurrencia
13.
Arch Surg ; 127(12): 1463-74, 1992 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-1365694

RESUMEN

The hypothalamic-pituitary-adrenal (HPA) system has been a model for neuroendocrine control of responses of organisms to stressors since the turn of the century. Despite this, the pathways by which infectious insults interact with the HPA system remained poorly defined. Recently, evidence has been presented suggesting that humoral mediators released by inflammatory cells (cytokines) may participate in two-way communication between the site of inflammation and the central nervous system. In this review, we detail the current understanding of the responses of the HPA system to the classic physiologic stimuli of hypovolemia and pain, with an emphasis on the cellular mechanisms and mediators discovered in recent years. We also examine the data substantiating a role of interleukin 1, interleukin 6, and tumor necrosis factor in the direct humoral activation of the HPA system and consider the evidence favoring a physiologic negative feedback relationship between the HPA and the immune systems. Such as interaction is an exciting concept with broad clinical implications. However, we believe that the temporal and quantitative aspects of experiments designed to evaluate this interaction must be carefully evaluated to assure that true physiologic stimuli are studied and that the responses observed are not due to pharmacologic effects of inflammatory mediators acting through "classic" neuroendocrine pathways.


Asunto(s)
Citocinas/fisiología , Sistema Hipotálamo-Hipofisario/inmunología , Sistema Hipófiso-Suprarrenal/inmunología , Vías Aferentes/fisiología , Animales , Formación de Anticuerpos/inmunología , Retroalimentación/fisiología , Humanos , Sistema Hipófiso-Suprarrenal/inervación
14.
Arch Surg ; 119(7): 849-53, 1984 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-6375635

RESUMEN

Despite a paucity of published clinical trials, use of the Angelchik antireflux prosthesis has increased dramatically since its introduction in 1979. Serious complications of this device have begun to appear. We dealt with two cases of erosion of the prosthesis into the gastrointestinal tract, one of which represents, to our knowledge, the first reported case of a gastroenteric fistula secondary to the device. Other complications of the use of this prosthesis have appeared in the literature. Carefully controlled clinical studies with long-term follow-up are needed to assess the overall benefits and safety of this new antireflux prosthesis.


Asunto(s)
Reflujo Gastroesofágico/prevención & control , Prótesis e Implantes/efectos adversos , Falla de Equipo , Femenino , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/cirugía , Humanos , Obstrucción Intestinal/diagnóstico por imagen , Obstrucción Intestinal/etiología , Obstrucción Intestinal/cirugía , Masculino , Persona de Mediana Edad , Radiografía , Gastropatías/diagnóstico por imagen , Gastropatías/etiología , Gastropatías/cirugía
15.
Arch Surg ; 132(5): 499-504, 1997 May.
Artículo en Inglés | MEDLINE | ID: mdl-9161392

RESUMEN

OBJECTIVES: To study the incidence of postoperative deep venous thrombosis (DVT) in patients undergoing elective aortic reconstruction and to determine if aggressive DVT prophylaxis would reduce the incidence of DVT in these patients. DESIGN: Randomized, prospective trial. SETTING: University hospital and Veterans Affairs hospital. PATIENTS: One hundred patients undergoing aortic reconstruction for aneurysmal or occlusive disease randomized to receive DVT prophylaxis (treatment group) or no prophylaxis (control group). Exclusion criteria included a history of DVT, long-term anticoagulant use, or a malignant neoplasm. During the study period, 12 patients were ineligible for follow-up. Ninety-eight patients completed the trial, including 50 patients in the treatment group and 48 patients in the control group. Two patients in the control group died postoperatively of unrelated causes. INTERVENTION: Patients in the treatment group received DVT prophylaxis using a combination of low-dose heparin sodium therapy (5000 U every 12 hours) and calf-length intermittent mechanical compression devices. Control patients received no DVT prophylaxis. MAIN OUTCOME MEASURES: The occurrence of acute lower extremity DVT diagnosed by interval venous duplex ultrasound scan surveillance performed on postoperative days 1, 3, and 7. RESULTS: The overall incidence of proximal DVT in this study was 2%. One case of DVT occurred in the treatment group, and the other one occurred in the control group. There was no statistically significant difference (P = .99) in the incidence of DVT between the 2 groups. One patients in the control group had a nonfatal pulmonary embolus (1% of the patients overall). CONCLUSIONS: The incidence of proximal DVT in patients undergoing elective aortic reconstruction is low compared with patients undergoing other major intraabdominal general surgical procedures. The use of aggressive DVT prophylaxis did not reduce the risk of postoperative proximal DVT in this study. The selective use of DVT prophylaxis in patients undergoing elective aortic surgery should be based on associated concomitant or evolving risk factors.


Asunto(s)
Enfermedades de la Aorta/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Tromboflebitis/epidemiología , Tromboflebitis/prevención & control , Adulto , Anciano , Anciano de 80 o más Años , Costos y Análisis de Costo , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Embolia Pulmonar/epidemiología , Embolia Pulmonar/prevención & control , Terapia Trombolítica/economía
16.
AJNR Am J Neuroradiol ; 20(1): 177-8, 1999 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9974078

RESUMEN

A woman reported painful thrombosis of the superficial femoral artery 16 months after a transfemoral microcatheter was glued into a cerebral arteriovenous malformation and transected at the groin. When the catheter was removed, a portion was found to be incorporated into the wall of the carotid artery. This case demonstrates that portions of a retained microcatheter may be incorporated into the arterial wall while other portions may remain mobile and cause late peripheral arterial symptoms.


Asunto(s)
Arteria Carótida Interna , Cateterismo/efectos adversos , Embolización Terapéutica/efectos adversos , Cuerpos Extraños/diagnóstico , Malformaciones Arteriovenosas Intracraneales/terapia , Adulto , Arteria Carótida Interna/cirugía , Embolización Terapéutica/instrumentación , Femenino , Arteria Femoral , Cuerpos Extraños/complicaciones , Cuerpos Extraños/cirugía , Humanos , Radiografía Intervencional , Trombosis/diagnóstico , Trombosis/etiología
17.
Am J Surg ; 178(2): 92-7, 1999 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10487256

RESUMEN

BACKGROUND: Techniques for placement of inferior vena cava (IVC) filters have undergone continued evolution from open surgical exposure of the venous insertion site to percutaneous insertion in most cases today. However, the required transport either to an operating room or interventional suite can be complex and potentially hazardous for the multiply injured trauma patient who may require ventilator support, controlled intravenous infusions, or skeletal immobilization. Increased experience with color-flow duplex scanning for routine IVC imaging and portability of ultrasound equipment have suggested the usefulness of duplex-guided IVC filter insertion (DGFI) in critically ill trauma and intensive care unit (ICU) patients. METHODS: A total of 25 multitrauma/ICU patients were considered for DGIF. Screening color-flow duplex scans were performed on all patients, and obesity or bowel gas prevented ultrasound imaging in 2 cases, leaving 23 patients suitable for DGFI. In each case, the IVC was imaged in the transverse and longitudinal planes. The right renal artery was identified as it passed posterior to the IVC and was used as a landmark of the infrarenal segment of the IVC. All procedures were performed at the bedside in a monitored ICU setting using percutaneous placement of titanium Greenfield filters. Duplex scanning after insertion was used to document proper placement, and circumferential engagement of the filter struts in the IVC wall. An abdominal radiograph was also obtained in each case to confirm proper filter location. Duplex ultrasound imaging was repeated within 1 week of insertion to assess IVC and insertion site patency. RESULTS: DGFI was successful in all cases. The filter was deployed at a suprarenal level in one case, as was recognized at the time of postprocedural scanning. Three patients died as a result of their injuries but there were no pulmonary embolism deaths. Repeat duplex scanning was obtained in 17 patients, and revealed no case of IVC or insertion site thrombosis. CONCLUSIONS: Vena caval interruption can be safely performed under ultrasound guidance in a monitored, ICU environment. In selected multiply injured trauma patients, this will reduce the risk, complexity and cost of transport for these critically ill patients. DGFI also reduces procedural costs compared with an operating room or interventional suite, and eliminates intravenous contrast exposure. Preprocedural scanning is essential to identify patients suitable for DGFI, and careful attention must be paid to the known ultrasonographic anatomical landmarks.


Asunto(s)
Traumatismo Múltiple/complicaciones , Ultrasonografía Doppler Dúplex , Ultrasonografía Intervencional , Filtros de Vena Cava , Adulto , Anciano , Cateterismo Periférico , Causas de Muerte , Cuidados Críticos , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Inmovilización , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Transferencia de Pacientes , Radiografía , Arteria Renal/diagnóstico por imagen , Respiración Artificial , Estudios Retrospectivos , Titanio , Ultrasonografía Doppler en Color , Ultrasonografía Doppler Dúplex/economía , Ultrasonografía Intervencional/economía , Grado de Desobstrucción Vascular , Vena Cava Inferior/diagnóstico por imagen
18.
Am J Surg ; 178(3): 194-6, 1999 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10527437

RESUMEN

BACKGROUND: Coronary artery disease occurs frequently in patients undergoing aortic reconstruction, and it has been presumed that internal carotid artery occlusive disease is also common. This has led to the practice of screening for and repairing significant carotid lesions in asymptomatic patients prior to aortic reconstruction. The purpose of this study was to determine the true prevalence of internal carotid artery disease in these patients. METHODS: The records of 240 patients who underwent duplex ultrasound screening for carotid artery disease prior to aortic reconstruction were reviewed. Surgery was performed for aortic aneurysm (AA) or aorto-iliac occlusive disease (AO). The prevalence of hyperlipidemia and coronary artery disease was similar between the two groups, but tobacco use, hypertension, and diabetes mellitus differed. RESULTS: Internal carotid artery stenosis > or = 50% occurred in 26.7% of the total group (64 of 240 cases). Stenosis > or = 50% was more common in the AO group (40 of 101 cases, 39.6%) than the AA group (24 of 139 cases, 17.3%, P = 0.0001). Severe disease (70% to 99%) was also more common in the AO group than the AA group (9.9% versus 3.6%, P = 0.0464). CONCLUSION: Internal carotid artery disease occurs commonly in patients undergoing aortic reconstruction, and screening is worthwhile. Significant disease is more common in patients with aorto-iliac occlusive disease than in those with aortic aneurysm, although atherosclerotic risk factors occur with varying frequency in the two groups. These findings suggest that additional factors may contribute to the higher prevalence of internal carotid artery stenosis in aorto-iliac occlusive disease.


Asunto(s)
Enfermedades de la Aorta/cirugía , Estenosis Carotídea/epidemiología , Anciano , Aneurisma de la Aorta/complicaciones , Aneurisma de la Aorta/cirugía , Enfermedades de la Aorta/complicaciones , Arteriopatías Oclusivas/complicaciones , Arteriopatías Oclusivas/cirugía , Arteria Carótida Interna , Estenosis Carotídea/complicaciones , Estenosis Carotídea/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Ultrasonografía Doppler Dúplex
19.
J Cardiovasc Pharmacol Ther ; 6(1): 31-6, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11452334

RESUMEN

BACKGROUND: Cross-clamping of the descending aorta during operative repairs causes sudden, significant reductions in renal function that may persist well beyond arterial clamp release. Commonly used agents, such as dopamine and mannitol, have not consistently affected renal outcome in these high-risk patients. Fenoldopam mesylate is a novel, highly selective dopamine type-1 agonist that preferentially dilates the renal and splanchnic vasculature, but has not been investigated in patients undergoing prolonged aortic clamping for whom adverse renal outcomes should be more likely. METHODS AND RESULTS: Twenty-two adult patients without significant pre-existing renal dysfunction and presenting for elective repairs of abdominal aortic aneurysms were studied. Fenoldopain mesylate was infused after obtaining baseline values ranging from 0.1 to 1.0 microg/kg/min for the first 24 hours postoperatively to maintain mean arterial pressure +/-25% baseline. Serial renal function indices, including creatinine clearance and electrolyte fractional excretions, were measured at baseline, at aortic clamping and unclamping, and post-clamp release, and were estimated through hospital discharge. Creatinine clearance fell during abdominal exploration and clamping, reaching a nadir with clamp removal. Partial recovery occurred by 2 hours after clamp removal, and returned to baseline values by postoperative day 1 and thereafter. Fractional excretions rose rapidly throughout the operative phase. Total fenoldopam dose was directly related to the baseline creatinine clearance; after clamp removal, creatinine clearance was directly related to the mean arterial pressure at the lowest dose of fenoldopam, and inversely related to the mean arterial pressure at clamp release. CONCLUSIONS: In elderly patients with severe vascular disease undergoing aneurysmal repairs, the use of a fenoldopam infusion in this open-label, uncontrolled trial was associated with a relatively rapid return of renal function to baseline values, despite profound decreases during aortic cross-clamping. Further studies will be necessary to investigate how fenoldopam infusions compare with traditional therapies.


Asunto(s)
Aorta/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Quirúrgicos Cardiovasculares/efectos adversos , Agonistas de Dopamina/farmacología , Fenoldopam/farmacología , Riñón/irrigación sanguínea , Insuficiencia Renal/prevención & control , Adulto , Factores de Edad , Anciano , Agonistas de Dopamina/administración & dosificación , Femenino , Fenoldopam/administración & dosificación , Humanos , Infusiones Intravenosas , Riñón/fisiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Insuficiencia Renal/etiología , Instrumentos Quirúrgicos , Resultado del Tratamiento
20.
Science ; 343(6171): 631-4, 2014 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-24457214

RESUMEN

One-dimensional (1D) interacting electronic systems exhibit distinct properties when compared to their counterparts in higher dimensions. We report Coulomb drag measurements between vertically integrated quantum wires separated by a barrier only 15 nanometers wide. The temperature dependence of the drag resistance is measured in the true 1D regime where both wires have less than one 1D subband occupied. As a function of temperature, an upturn in the drag resistance is observed below a temperature T* ~ 1.6 kelvin. This crossover in Coulomb drag behavior is consistent with Tomonaga-Luttinger liquid models for the 1D-1D drag between quantum wires.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda