RESUMEN
It remains a challenge to exploit dual-functional metal-organic frameworks (MOFs) for applications, including luminescence detection and proton conduction. With the deliberate selection of the bifunctional organic ligand 5-sulfoisophthalic acid monosodium salt (NaH2bts), and the phosphonic acid ligand N,N'-piperazine (bismethylenephosphonic acid; H4L), a robust three-dimensional (3D) noninterpenetrating dual-functional MOF, [Tb(H2L)(H2bts)(H2O)]·H2O (1), has been synthesized hydrothermally. On the basis of the excellent thermal and chemical as well as superior luminescence stabilities in water and solutions with different pHs, 1 can serve as the simple, rapid, and highly selective and sensitive luminescence detection of the carcinoid biomarkers 5-hydroxytryptamine (HT) and its metabolite 5-hydroxyindole-3-acetic acid (HIAA) with detection limits of nanomolar magnitude in water and in simulated blood plasma and urine systems. Due to the change in the signals that could be readily differentiated by the naked eye under a UV lamp, a portable test paper has been developed. The probable quenching mechanisms are discussed in detail. In addition, a great number of hydrogen-bonding networks are formed among the uncoordinated carboxylic oxygen atoms, sulfonate oxygen atoms, protonated nitrogen atoms, and water molecules, which provide potential proton-hopping sites for proton conduction, leading to a maximum proton conductivity of 2.3 × 10-4 S cm-1 at 368 K and 95% relative humidity. The above results suggest that rationally designed dual-functional MOFs can open an avenue for the development of occupational diagnostic tools and alternative energy technology.
Asunto(s)
Tumor Carcinoide/química , Luminiscencia , Estructuras Metalorgánicas/química , Protones , Biomarcadores/análisis , Estructuras Metalorgánicas/síntesis química , Modelos MolecularesRESUMEN
OBJECTIVE: To determinethe diagnostic valuesand reliabilityof cardiac magnetic resonance tissue tracking (CMR-TT) derived two-dimensional(2D) and three-dimensional(3D) strains in assessing experimental autoimmunity myocarditis (EAM) in rats. METHODS: 20 Lewis rats were randomly divided into model and control groups. The animal model of autoimmune myocarditis was induced by injecting porcine cardiac myosin into the footpads of the rats.On day 35, all of the rats were examined using the 7.0T CMR cine scan. The cardiac function and global strain of the left ventricular of the rats were analyzed with specific cardiac post-processing. The rats were then sacrificed and myocardial samples were taken and stained with HE and Masson. The diagnostic values of the strain parameters were assessed by receiver operating characteristic (ROC) curves with the pathological results as diagnostic criteria.The reliability of the strain parameters were tested using interclass correlation coefficient (ICC), coefficients of variation (CV) and Bland-Altman. RESULTS: No abnormal pathological changes in myocardial cells were found in the control group. Myocarditis was successfully induced in all of the rats in the model group, showing myocardial fiber arrangement disorder, degeneration, necrosis, inflammatory cell infiltration and interstitial fibrosis. The ROC showed that 2D global strain parameters possessed higher diagnostic values than 3D strain parameters. The 2D had an area under the curve (AUC) of 0.96 in global circumferential strain (GCS), 0.95 in global radial strain (GRS), and 0.90 in global longitudinal strain (GLS), compared with 0.87 GCS, 0.85 GRS, and 0.77 GLS in the 3D, respectively.The reliability of the 2D strain parameters was high, except for inter-observer 2D GRS(ICC=0.893). The 3D strain parameters had lower reliability (ICCs:0.421-0.79) than the 2D strain parameters (ICCs:0.893-0.986). CONCLUSION: The diagnostic values of 2D strain parameters are higher than 3D strain parameters in diagnosing myocarditis.
Asunto(s)
Enfermedades Autoinmunes/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Miocarditis/diagnóstico por imagen , Animales , Modelos Animales de Enfermedad , Distribución Aleatoria , Ratas , Ratas Endogámicas Lew , Reproducibilidad de los Resultados , Porcinos , Función Ventricular IzquierdaRESUMEN
Toxicity is one of the major reasons for failure in drug development. Zebrafish, as an ideal vertebrate model, could also be used to evaluate drug toxicity. In this study, we aimed to show the predictability and highlight novel findings of toxicity in zebrafish model. Seven anticancer compounds, including triptolide (TP), gambogic acid (GA), mycophenolic acid (MPA), curcumin, auranofin, thalidomide, and taxol, were assessed in zebrafish for their toxicity. Three compounds (GA, TP, and taxol) showed highest acute lethality, with 50% lethal concentration ≈ 1 µmol/L. Missing tails, severe pericardial edema, and enlarged yolk sacs were observed in MPA-treated embryos. The development of pectoral fins was severely disturbed in thalidomide-, GA-, and TP-treated embryos. Bradycardia was observed in MPA- and thalidomide-treated groups. Our findings suggested that the zebrafish are a good model for toxicity assessment of anticancer compounds.
Asunto(s)
Antineoplásicos/toxicidad , Pez Cebra/fisiología , Animales , Enfermedades Cardiovasculares/inducido químicamente , Embrión no Mamífero/efectos de los fármacos , Desarrollo Embrionario/efectos de los fármacos , Hemodinámica/efectos de los fármacos , Larva/anatomía & histología , Larva/efectos de los fármacos , Dosificación Letal Mediana , Teratógenos/toxicidadRESUMEN
BACKGROUND: Stroke often results in significant respiratory dysfunction in patients. Respiratory muscle training (RMT) has been proposed as a rehabilitative intervention to address these challenges, but its effectiveness compared to routine training remains debated. This systematic review and meta-analysis aim to evaluate the effects of RMT on exercise tolerance, muscle strength, and pulmonary function in post-stroke patients. AIM: To systematically assess the efficacy of RMT in improving exercise tolerance, respiratory muscle strength, and pulmonary function in patients recovering from a stroke, and to evaluate whether RMT offers a significant advantage over routine training modalities in enhancing these critical health outcomes in the post-stroke population. METHODS: Following the Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines, a comprehensive search across PubMed, Embase, Web of Science, and the Cochrane Library was conducted on October 19, 2023, without temporal restrictions. Studies were selected based on the predefined inclusion and exclusion criteria focusing on various forms of RMT, control groups, and outcome measures [including forced expiratory volume in the first second (FEV1), forced vital capacity (FVC), maximal voluntary ventilation (MVV), peak expiratory flow (PEF), maximal inspiratory pressure (MIP), maximal expiratory pressure (MEP), and 6-min walking test (6MWT)]. Only randomized controlled trials (RCTs) were included. Data extraction and quality assessment were conducted independently by two reviewers using the Cochrane Collaboration's risk of bias tool. Statistical analyses, including those using the fixed-effect and random-effects models, sensitivity analysis, and publication bias assessment, were performed using Review Manager software. RESULTS: A total of 15 RCTs were included. Results indicated significant improvements in MIP (12.51 cmH2O increase), MEP (6.24 cmH2O increase), and various pulmonary function parameters (including FEV1, FVC, MVV, and PEF). A substantial increase in 6MWT distance (22.26 meters) was also noted. However, the heterogeneity among studies was variable, and no significant publication bias was detected. CONCLUSION: RMT significantly enhances walking ability, respiratory muscle strength (MIP and MEP), and key pulmonary function parameters (FEV1, FVC, MVV, and PEF) in post-stroke patients. These findings support the incorporation of RMT into post-stroke rehabilitative protocols.
RESUMEN
OBJECTIVES: To evaluate the performance of a dual-energy computed tomography (DECT) virtual non-calcium (VNCa) technique in the detection of edema-like marrow signal intensity (ELMSI) in patients with knee joint osteoarthritis (OA) compared to magnetic resonance imaging (MRI). METHODS: The study received local ethics board approval, and written informed consent was obtained. DECT and MRI were used to examine 28 knees in 24 patients with OA. VNCa images were generated by dual-energy subtraction of calcium. The knee joint was divided into 15 regions for ELMSI grading, performed independently by two musculoskeletal radiologists, with MRI as the reference standard. We also analyzed CT numbers through receiver operating characteristics and calculated cut-off values. RESULTS: For the qualitative analysis, we obtained CT sensitivity (Readers 1, 2 = 83.7%, 89.8%), specificity (Readers 1, 2 = 99.5%, 99.5%), positive predictive value (Readers 1, 2 = 95.3%, 95.7%), and negative predictive value (Readers 1, 2 = 97.9%, 98.7%) for ELMSI. The interobserver agreement was excellent (κ = 0.92). The area under the curve for Reader 1 and Reader 2 was 0.961 (95% CI 0.93, 0.99) and 0.992 (95% CI 0.98, 1.00), respectively. CT numbers obtained from the VNCa images were significantly different between regions with and without ELMSI (p < .001). CONCLUSIONS: VNCa images have good diagnostic performance for the qualitative and quantitative analysis of knee osteoarthritis-related ELMSI.
RESUMEN
The exploration of low-cost, long-term stable, and highly electrochemically active cathode catalysts is important for the practical application of microbial fuel cell (MFC). In this work, a series of the 3D hierarchical porous Co-N-C (3DHP Co-N-C) materials are designed and synthesized by a metal-organic framework ZIF-67 as a precursor and SiO2 sphere of different sizes as the hard template. The 3DHP Co-N-C-2 with 129 nm macropore exhibits excellent ORR performance in 0.1 M KOH solution with a half-wave potential of 0.80 V vs. RHE and superior durability than Pt/C (20%) due to the specific macropore-mesopore-micropore structure that exposes a large number of active sites and accelerates the electrolyte transport and oxygen diffusion. The MFC with 3DHP Co-N-C-2 as the cathode catalysts shows excellent performance with a maximum power density of 426.9±7.87 mW m-2 and favorable durability after 50 d of operation. In addition, 16s rDNA results reveal the presence of different dominant electrogenic bacteria and different abundance of important non-electrogenic bacteria in the anode biofilm in MFCs using cathode catalysts with different ORR activity. And 3DHP Co-N-C-2 was found to be beneficial to the synergistic effect of electrogenic and non-electrogenic bacteria. This study explores electrocatalysts in terms of both electrocatalytic activity and anode microorganisms, providing new and comprehensive insights into the power generation of MFC.
Asunto(s)
Fuentes de Energía Bioeléctrica , Microbiota , Biopelículas , Carbono , Electrodos , Porosidad , Dióxido de SilicioRESUMEN
Though a number of Eimeria tenella rhoptry kinase family proteins have been identified, little is known about their molecular functions. In the present study, the gene fragment encoding the matured peptide of E. tenella rhoptry kinase family protein 17 (EtROP17) was used to construct a recombinant vector, followed by transfection into leghorn male hepatoma (LMH) cells. Then, the transcriptional changes in the transfected cells were determined by RNA-seq. The expression of EtROP17 in LMH cells was validated by both Western blot and indirect immunofluorescence analysis. Our analysis showed that EtROP17 altered the expression of 309 genes (114 downregulated genes and 195 upregulated genes) in LMH cells. The quantitative real-time polymerase chain reaction (qRT-PCR) results of the selected differentially expressed genes (DEGs) were consistent with the RNA-seq data. Kyoto Encyclopedia of Genes and Genomes (KEGG) analysis showed that DEGs were significantly enriched in nine pathways, such as toll-like receptor signaling pathway, ECM-receptor interaction, intestinal immune network for IgA production and focal adhesion. These findings reveal several potential roles of EtROP17, which contribute to understanding the molecular mechanisms underlying the host-parasite interplay.
RESUMEN
Though genome sequencing of Eimeria tenella predicts more than 8,000 genes, the molecular functions of many proteins remain unknown. In this study, the coding region corresponding to the mature peptide of a hypothetical protein of E. tenella (ETH_00023950) was amplified and expressed in a bacterial system. Following preparation of polyclonal antibody that recognizes ETH_00023950, the expression of ETH_00023950 in merozoites was examined. Meanwhile, we determined the transcriptomic responses of the leghorn male hepatoma (LMH) cells to its expression. Sequencing analysis showed that one single nucleotide polymorphism and one indel of ETH_00023950 of E. tenella SD-01 strain were found compared with that of the UK reference Houghton strain, leading to a frame shift and a premature stop codon. The expression of ETH_00023950 in E. tenella merozoites was confirmed by indirect immunofluorescence and Western blot analysis. Transcriptomic analysis showed that ETH_00023950 altered the expression of 2,680 genes (321 downregulated genes and 2,359 upregulated genes) in LMH cells. The RNA-sequencing data were consistent with the results of the quantitative real-time polymerase chain reaction (qRT-PCR). Kyoto Encyclopedia of Genes and Genomes (KEGG) enrichment analysis revealed that differentially expressed transcripts were significantly related to 8 pathways, including oxidative phosphorylation and TGF-beta signaling pathway. These findings contribute to understanding host-pathogen interaction and secondary bacterial infections related to E. tenella.
Asunto(s)
Coccidiosis , Eimeria tenella , Animales , Masculino , Eimeria tenella/genética , Pollos/genética , Transcriptoma , Merozoítos/genética , Perfilación de la Expresión Génica/veterinaria , Coccidiosis/veterinaria , Coccidiosis/metabolismoRESUMEN
OBJECTIVE: To systematically evaluate the acceptability of high-technology augmentative and alternative communication (high-tech AAC) among ICU patients who are voiceless guided by the technology acceptance model (TAM). METHODS: We searched the Cochrane Library, EMBASE, PubMed, CINAHL, PsycINFO, Web of Science, SinoMed, China National Knowledge Infrastructure (CNKI), China Science and Technology Journal Database and Wanfang Database from database inception to September 2019. Studies that examined conscious nonverbal ICU patients with high-tech AAC intervention were included. Two reviewers independently collected and evaluated all the studies. The methodological quality was assessed by using the Joanna Briggs Institute critical appraisal tool. RESULTS: Eighteen studies with a total of 914 patients met the inclusion criteria, and the quality of the studies varied from low to moderate. Based on the TAM, ICU voiceless patients perceived that high-tech AAC was useful, was easy to use, decreased communication difficulties, reduced negative emotions, and improved symptom identification and management. Patients maintained a positive attitude and were willing to continue to use high-tech AAC. CONCLUSIONS: Although the existing evidence is limited, voiceless patients regard high-tech AAC devices as a useful, reliable, and acceptable alternative communication choice in the ICU. Multicenter, large-sample, and high-quality studies are highly recommended in the future.
Asunto(s)
Equipos de Comunicación para Personas con Discapacidad , Unidades de Cuidados Intensivos , China , Comunicación , Humanos , Estudios Multicéntricos como Asunto , TecnologíaRESUMEN
OBJECTIVE: To observe the clinical effect on post-stroke oculomotor nerve palsy treated with the interaction of twelve meridian muscle regions and contralateral needling therapy. METHODS: A total of 46 patients with post-stroke oculomotor nerve palsy were randomized into an observation group and a control group, 23 cases in each one. In the control group, the intramusclar injection of mecobalamine at the buttock region was given, 1 mL each time, once every two days, 3 times weekly. Besides, citicoline sodium capsules were prescribed for oral administration, 0.2 g each time, 3 times daily. In the observation group, on the base of the treatment as the control group, the interaction of twelve meridian muscle regions and contralateral needling therapy was supplemented. Acupoints on the health sides included Juliao (ST 3) and Hanyan (GB 4), acupoints on the affected side included Jingming (BL 1), Sibai (ST 2), Yangbai (GB 14), Cuanzhu (BL 2), Shangming (Extra), Sizhukong (TE 23), Tongziliao (GB 1) and bilateral Fengchi (GB 20), Quchi (LI 11), Pianli (LI 6), Waiguan (TE 5), Hegu (LI 4) were selected. The needles were retained for 30 min in each acupuncture treatment, once a day, 5 times weekly. The treatment for 4 weeks was required in the two groups. Before and after treatment, the score of cervical range of motion (CROM), pupil size, eye fissure width and eyeball mobility were observed in the patients of the two groups. The clinical effect was evaluated in the two groups. RESULTS: After treatment, CROM scores and pupil size were reduced in the patients of the two groups (P<0.05), and the values in the observation group were lower than the control group (P<0.05). The eye fissure width and eyeball mobility were increased in the two groups (P<0.05), the eye fissure width and the mobility of the muscles of rectus internus, inferior rectus and inferior oblique in the observation group were larger than the control group (P<0.05). The effective rate was 82.6% (19/23) in the observation group, higher than 65.2% (15/23) in the control group (P<0.05). CONCLUSION: The interaction of twelve meridian muscle regions and contrallateral needling therapy effectively relieves diplopia, pupil dilation, narrow eye fissure and limited eyeball mobility in the patients with post-stroke oculomotor nerve palsy.
Asunto(s)
Terapia por Acupuntura , Meridianos , Enfermedades del Nervio Oculomotor , Accidente Cerebrovascular , Puntos de Acupuntura , Humanos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/terapia , Resultado del TratamientoRESUMEN
OBJECTIVE: The objective of this study was to develop magnetic embolic microspheres that could be visualized by clinical magnetic resonance imaging (MRI) scanners aiming to improve the efficiency and safety of embolotherapy. METHODS AND DISCUSSION: Magnetic ferrite nanoclusters (FNs) were synthesized with microwave-assisted solvothermal method, and their morphology, particle size, crystalline structure, magnetic properties as well as T2 relaxivity were characterized to confirm the feasibility of FNs as an MRI probe. Magnetic polymer microspheres (FNMs) were then produced by inverse suspension polymerization with FNs embedded inside. The physicochemical and mechanical properties (including morphology, particle size, infrared spectra, elasticity, etc.) of FNMs were investigated, and the magnetic properties and MRI detectable properties of FNMs were also assayed by vibrating sample magnetometer and MRI scanners. Favorable biocompatibility and long-term MRI detectability of FNMs were then studied in mice by subcutaneous injection. FNMs were further used to embolize rabbits' kidneys to evaluate the embolic property and detectability by MRI. CONCLUSION: FNMs could serve as a promising MRI-visualized embolic material for embolotherapy in the future.
Asunto(s)
Embolización Terapéutica , Compuestos Férricos/química , Imagen por Resonancia Magnética , Magnetismo , Microesferas , Nanopartículas/química , Polímeros/química , Animales , Dispersión Dinámica de Luz , Elasticidad , Femenino , Hierro/metabolismo , Riñón/diagnóstico por imagen , Riñón/patología , Masculino , Ratones , Nanopartículas/ultraestructura , Tamaño de la Partícula , Espectroscopía de Fotoelectrones , ConejosRESUMEN
To develop embolic microspheres with MRI detectability, superparamagnetic iron oxide nanoparticles (SPIONs) were synthesized and mixed with monomer of acrylic acid to prepare SPIONs-loaded polymerized microspheres (SPMs) by inverse suspension polymerization method. The SPMs were evaluated for the ability of embolization by investigating the morphology, particle size, elasticity and renal arterial embolization to rabbits. Meanwhile, the loading of SPIONs was verified by optical microscope, transmission electron microscope, Fourier transform infrared spectrum, vibrating sample magnetometer, X-ray diffraction and X-ray photoelectron spectroscopy, and the content of SPIONs in SPMs was measured quantitatively. Furthermore, the MRI detectability of SPMs was testified in gel phantom, mice and rabbits respectively by a clinical 3.0T MRI scanner. The results revealed the SPMs were potential MRI detectable embolic microspheres for improving the effectiveness and safety of embolotherapy in the future.
Asunto(s)
Resinas Acrílicas/química , Embolización Terapéutica , Nanopartículas de Magnetita/química , Microesferas , Animales , Imagen por Resonancia Magnética , Masculino , Ratones , ConejosRESUMEN
Nano-diamond was synthesized by TNT/RDX explosives detonation in a steel chamber and characterized by X-ray diffraction (XRD), laser Raman spectroscopy, and infrared spectroscopy. XRD results indicate that nano-diamond has cubic diamond structure. The parameter of unit cell of nano-diamond is 0.359 23 nm and is 0.72% larger than that of the bulk diamond. The high-density defects and other impurity atoms in the nano-diamond structure may lead to the large lattice constant. The examination results of Raman spectra show that the Raman band is broader and shifts to l ow frequency by 3 cm(-1), because the size of nano-diamond reaches nanometer order. There is little graphite in the nano-diamond. There are two peaks in FTIR of the nano-diamond, which are characteristic peaks of diamond at 1 262 and 1 134 cm(-1). Besides these two peaks, there are six peaks at 3 422, 1 643, 2 971, 2 930, 2 857 and 1 788 cm(-1) respectively. The FTIR bands at 2 930 and 2 857 cm(-1) are the antisymmetrical and symmetrical stretch vibration absorption spectra of CH2 respectively. The 3 422 cm(-1) is the stretch vibration absorption peak of O-H. The 1 634 cm(-1) confirms that there are H2O in the nano-diamond. The 2 971 cm(-1) is the antisymmetrical stretch vibration absorption peak of CH3. The 1 788 cm(-1) is the stretch vibration absorption peak of C=O. These indicate that there are H and O elements in the nano-diamond. From the mechanism of the nano-diamond, the authors discuss the reason for the vibration absorption peaks of O-H, CH2, CH3, and C=O, existing in the FTIR of the nano-diamond.
Asunto(s)
Diamante/química , Sustancias Explosivas/química , Espectroscopía Infrarroja por Transformada de Fourier , Espectrometría Raman , Algoritmos , Cristalización , Nanoestructuras/química , Triazinas/química , Trinitrotolueno/química , Difracción de Rayos XRESUMEN
The nano-graphite powder synthesized by the detonation of explosives with negative oxygen balance is a new powder material with potential applications. In this work, the preparation of nano-graphite powder in steel chamber by pure TNT (trinitrotoluene) explosives has been introduced. In the synthesis process, the protective gases in the steel chamber are N2, CO2 and Ar, and the pressure is 0.25-2 atm. Raman spectrum of the nano-graphite was measured. The characteristic Raman band assigned to sp2 of graphite has been observed at about 1 585 cm(-1) with half-peak width of 22 cm(-1). The peak shifted to a higher frequency by 5 cm(-1) compared with that of bulk graphite. The authors explain this blue shift phenomenon by size effect. The average size of nanographite from Raman measurement is 2.97-3.97 nm. X-ray diffraction (XRD) and transmission electron microscopy (TEM) were used to measure the structure and particle size of the nano-graphite. The crystallite size of nano-graphite estimated from XRD andTEM are 2.58 nm (acid untreated) and 1.86 nm (acid treated) respectively, which is in accord with the results of the measurement approximately.
Asunto(s)
Sustancias Explosivas/química , Grafito/química , Espectrometría Raman , Trinitrotolueno/química , Argón/química , Dióxido de Carbono/química , Cristalización , Grafito/síntesis química , Microscopía Electrónica de Transmisión , Nanoestructuras/química , Nitrógeno/química , Tamaño de la Partícula , Polvos , Difracción de Rayos XRESUMEN
The loss of cultural information transmission, inaccurate of translation or misunderstanding of the whole sentence in acupuncture translation are illustrated in this article. It suggests that these mistakes should be paid attention to and avoided; simultaneously, the solutions are stated so as to insure the accurate transmission of acupuncture.