Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Zhonghua Wai Ke Za Zhi ; 57(10): 38-43, 2019 Oct 01.
Artículo en Zh | MEDLINE | ID: mdl-31510731

RESUMEN

Objective: To evaluate the accuracy of endoscopic titanium clip localization combined with CT three-dimensional reconstruction for the control of incision margin in early gastric cancer under laparoscopy. Methods: A prospective analysis was made for gastric cancer whose lesions were located in the middle of the stomach and T stage was 1 to 2 from October 2017 to January 2019 at Department of Gastrointestinal and Pancreatic Surgery, Zhejiang Provincial People's Hospital. Totally 25 patients were eventually enrolled in the study. There were 17 males and 8 females aging of (63.6± 7.2) years (range: 48 to 77 years). All cases were treated with titanium clip localization under endoscope combined with CT three-dimensional (3D) reconstruction to construct a virtual panorama of gastric cavity and lesions, and to design surgical margins. Laparoscopic surgical resection was performed according to the surgical margins designed before operation. The distance from the gastric angle to the origin of the minor curvature of the incisional margin, the distance from the gastric angle to the the center of lesion and the distance of the upper incision margin were measured under three-dimensional CT reconstruction and under actual specimen. Paired t test was used to compare the three distances measured by two methods. Results: The measured distances from the gastric angle to the center of the lesion and the proximal incisional margin under 3D reconstruction CT were according to the measured values of actual specimens ((2.67±1.38) cm vs. (2.83±1.56) cm, t=1.51, P=0.14; (5.23±0.60) cm vs. 5 cm, t=1.93, P=0.07); the measured distances from the gastric angle to the origin of the minor curvature of the incisional margin under CT 3D reconstruction were different with the measured values of solid specimens ((5.94±0.94) cm vs. (6.37±0.90) cm, t=3.52, P=0.00). Conclusion: The method of titanium clip localization combined with CT 3D reconstruction can provide a feasible laparoscopic localization method and incision edge solution for T1 to 2 gastric central cancer.


Asunto(s)
Márgenes de Escisión , Neoplasias Gástricas/diagnóstico por imagen , Neoplasias Gástricas/cirugía , Anciano , Femenino , Gastrectomía , Gastroscopía , Humanos , Imagenología Tridimensional , Laparoscopía , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Instrumentos Quirúrgicos , Tomografía Computarizada por Rayos X
4.
Zhonghua Yi Xue Za Zhi (Taipei) ; 51(3): 200-7, 1993 Mar.
Artículo en Zh | MEDLINE | ID: mdl-8490794

RESUMEN

A dedicated X-ray mammography was introduced to our hospital from 1987 and an imaging receptor of xeroradiography was applied. We reported previously that the average air exposure was 0.79R and that the absorption dose of skin was 1.00 rad. These data are similar to literature reports. Screen-film mammography was introduced recently. To select the best breast imaging and the least radiation exposure, diverse methods were investigated. A dosimetry (Capintec model 192) and a PS-033 parallel ionization chamber were applied to compare the absorption dose on polystyrene phantom between various exposure factors, the application of breast clamp and the size of exposure field. Retrospective estimation of the radiation dose was obtained from the exposure factors of previous mammography since July, 1990 to May, 1992. There were 1035 xeromammographic examinations and 358 examinations with medium-speed screen-film mammography. Another 61 craniocaudal and 96 mediolateral projections with high-speed screen-film mammography were recruited during the recent two months. An ionization chamber (Exradin, Shonka-Wyckoff A5) with an electrometer (Keithley 617) wer selected to obtain the dose equivalent from air exposure between selected exposure factors. The radiation dose of mammography is linearly correlated with voltage/kV and current/mAs. The application of a breast clump reduces 10% of the skin dose. The average exposure factors of xeromammography are 45.6 kV, 163.5 mAs. These results remain the same as in our previous report. Xeromammography has a greater exposure to air, estimated average glandular dose and absorbed dose than screen-film mammography. The mean exposure factor of rapid screen-film mammography gains half the value of medium screen-film mammography, ie. 26.6 kV, 87.0 mAs vs. 26.0 kV, 164.5 mAs.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Mamografía , Dosis de Radiación , Femenino , Humanos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda