Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
Ther Drug Monit ; 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38723151

RESUMEN

BACKGROUND: The use of psychoactive substances (PSs) during pregnancy is a major public health concern because of their increasing prevalence worldwide. This study examined the understudied issue of gestational PS consumption in a cohort of Argentine delivering mothers. METHODS: A cross-sectional pilot study involving 51 women receiving delivery care was conducted at the Santa Rosa Hospital in La Pampa, Argentina. Information on maternal sociodemographic characteristics, pregnancy history, and drug use was obtained through standardized interviews. Maternal hair samples were analyzed for alcohol, tobacco, licit, illicit, and prescription substance biomarkers using ultra-high-performance liquid chromatography high-resolution mass spectrometry and gas chromatography mass spectrometry. RESULTS: During pregnancy, 49.0% of participants reported alcohol consumption, 25.5% reported tobacco use, and 23.5% reported cannabis use. Hair samples from 56.9% of the women were positive for illicit PSs, with the most frequent being cocaine (41.2%) and cannabis (15.7%). Among the women, 47.1% consumed alcohol during pregnancy. Of the 24 women with hair ethyl glucuronide ≥5 pg/mg, 33.3% drank until the end of gestation and 58.3% started a social drinking habit in the second half. The analysis also detected prescription substances (anticonvulsants, antidepressants, methadone, opioids, antihistamines, antiemetics, and analgesics), caffeine (70.6%), lidocaine, and levamisole, some of which were cocaine or opioid adulterants. CONCLUSIONS: This is the first study to objectively assess the consumption of licit and illicit PSs during pregnancy in Argentina. In contrast to most nearby countries, cocaine was the most detected illicit PS in this cohort of Argentine delivering women. This finding highlights the importance of regular monitoring of local trends in PS use during pregnancy.

2.
Clin Chem Lab Med ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38727000

RESUMEN

OBJECTIVES: Italy legalized cannabis oil for specific medical conditions (neuropathic pain, refractory epilepsy and other established pathologies) in 2015, but mandates titration of principal cannabinoids before marketing each batch using iphenated techniques coupled with mass spectrometry. To assess reliability of laboratories from the Italian National Health Service in charge of titrating the batches, the Italian National Institute of Health set up an quality control program on determination of Δ9-tetrahydrocannabinol l (THC), cannabidiol (CBD), Δ9-tetrahydrocannabinolic acid A (THCA-A) and cannabidiolic acid (CBDA) in cannabis oil preparations. METHODS: Two rounds of exercises have been carried out since 2019, involving sixteen Italian laboratories. Five different cannabis oil samples (19-1A and 19-1B for the first round and 22-1A, 22-1B and 22-1C for the second one were prepared and 1 mL amount of each sample was sent to the laboratories. The quantitative performance of each laboratory was assessed calculating the z-score value, a statistical measurement for value's relationship to the mean of a group of values. RESULTS: In the first round, eight out of fourteen laboratories employed an LC-MS while the remaining six used GC-MS. Differently, in the second round, six out of eleven laboratories employed a GC-MS while the remaining five used LC-MS. In the first round, only 28.6 % laboratories achieved an acceptable performance (z-score±2), and all of them used LC-MS as analytical method. In the second round, none of the laboratories achieved an acceptable performance. Satisfactory results, based on z-scores, were generally low (0.0-75.0 %), with only one exception of 100 % for THCA-A determination in sample 22-1B. In the second round, three false negatives (two THC and one CBD by GC-MS determination) were reported while no false positives were described in the blank sample. The two rounds yielded a mean ERR% of 42 % approximately and a mean CV% around 70 % in GC-MS determination. When applying LC-MS determination, the two rounds yielded a mean ERR% of 36 % approximately and a mean CV% around 33 %. CONCLUSIONS: The obtained results underline the need for a clear and consistent protocol to be adopted by all laboratories intending to include the titration of oily cannabis-based products into their routinely analytical techniques. This emphasis on methodology standardization and participation to quality control schemes is essential for ensuring reliable and accurate measurements, ultimately enhancing the overall effectiveness and reliability of medical cannabis treatments.

3.
Int J Mol Sci ; 24(11)2023 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-37298339

RESUMEN

This study presents a validated GC-MS/MS method for the detection and quantification of 4-chloromethcathinone or clephedrone (4-CMC), N-ethyl Pentedrone (NEP), and N-ethyl Hexedrone (NEH, also named HEXEN) in oral fluid and sweat and verifies its feasibility in determining human oral fluid concentrations and pharmacokinetics following the administration of 100 mg of 4-CMC orally and 30 mg of NEP and NEH intranasally. A total of 48 oral fluid and 12 sweat samples were collected from six consumers. After the addition of 5 µL of methylone-d3 and 200 µL of 0.5 M ammonium hydrogen carbonate, an L/L extraction was carried out using ethyl acetate. The samples, dried under a nitrogen flow, were then derivatized with pentafluoropropionic anhydride and dried again. One microliter of the sample reconstituted in 50 µL of ethyl acetate was injected into GC-MS/MS. The method was fully validated according to international guidelines. Our results showed how, in oral fluid, the two cathinones taken intranasally were absorbed very rapidly, within the first hour, when compared with the 4-CMC which reached its maximum concentration peak in the first three hours. We observed that these cathinones were excreted in sweat in an amount equivalent to approximately 0.3% of the administered dose for 4-CMC and NEP. The total NEH excreted in sweat 4 h after administration was approximately 0.2% of the administered dose. Our results provide, for the first time, preliminary information about the disposition of these synthetic cathinones in the consumers' oral fluid and sweat after controlled administration.


Asunto(s)
Cathinona Sintética , Espectrometría de Masas en Tándem , Humanos , Espectrometría de Masas en Tándem/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Proyectos Piloto , Sudor
4.
Eur Addict Res ; 28(5): 323-330, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35378545

RESUMEN

INTRODUCTION: New synthetic opioids (NSO), a class of new psychoactive substances (NPS), have recently emerged and pose an upcoming global public health challenge. The effects produced by NSO are similar to those from morphine, but they present greater pharmacological potency and abuse potential. Due to the increasing number of fatal overdoses and seizures in which NSO have been detected as heroin substitutes or adulterants, individuals with Opioid Use Disorder (OUD) represent a vulnerable population. The aim of our study was to describe and characterize from a gender perspective a Spanish cohort of potential conscious or unconscious NSO users. METHODS: A cross-sectional study was conducted in a cohort of OUD participants under treatment in addiction care services in Barcelona and Badalona, Spain. Clinical evaluation was performed through an ad hoc survey, a scale to evaluate reasons to use an opioid without prescription (range 0-4) and the Wellbeing Index (WHO-5) (range 0-100). Objective consumption of NSO was assessed by urinalysis carried out by two validated methods: high-sensitivity gas chromatography-mass spectrometry (MS) and ultra-high-performance liquid chromatography-high-resolution MS. RESULTS: A total of 154 participants with OUD were enrolled. They were mainly men (72.7%), mean age 47.8 years. Methadone was the predominant medication for opioid agonist treatment (mean dose 61.25 mg/day). A total of 32 (20.8%) participants reported having consumed some opioid to become "high" in the previous 3 months. The principal reasons for consuming illicit opioids were Replacing other drugs (mean 2.03) and Availability (mean 1.62), although Low price, was more highly valued by men (p = 0.045) and Shorter effect duration, most highly rated by women (p = <0.001). In the WHO-5, the mean score was 55 (SD = 30.1) without differences by gender. Fentanyl and derivatives or/and metabolites were detected in 7 (6.1%) participants, but illicit/non-prescribed NSOs were found in 5 out of 114 patients (4.4%), and other non-fentanyl opioids in 36 participants (26 men and 10 women). CONCLUSION: A non-negligible consumption of NSO-fentanyl's (positive detection in 6.1% of biological samples) was detected. The reasons for using these substances and also the well-being differed between the genders. There is therefore both voluntary and involuntary NSO consumption in our country which highlights the importance of approaching this potential public health problem.


Asunto(s)
Sobredosis de Droga , Trastornos Relacionados con Opioides , Analgésicos Opioides/uso terapéutico , Estudios Transversales , Femenino , Fentanilo , Humanos , Masculino , Persona de Mediana Edad , Trastornos Relacionados con Opioides/tratamiento farmacológico , Trastornos Relacionados con Opioides/epidemiología
5.
Int J Mol Sci ; 22(8)2021 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-33924438

RESUMEN

The use of the new psychoactive substances is continuously growing and the implementation of accurate and sensible analysis in biological matrices of users is relevant and fundamental for clinical and forensic purposes. Two different analytical technologies, high-sensitivity gas chromatography-mass spectrometry (GC-MS) and ultra-high-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS) were used for a screening analysis of classic drugs and new psychoactive substances and their metabolites in urine of formed heroin addicts under methadone maintenance therapy. Sample preparation involved a liquid-liquid extraction. The UHPLC-HRMS method included Accucore™ phenyl Hexyl (100 × 2.1 mm, 2.6 µm, Thermo, USA) column with a gradient mobile phase consisting of mobile phase A (ammonium formate 2 mM in water, 0.1% formic acid) and mobile phase B (ammonium formate 2 mM in methanol/acetonitrile 50:50 (v/v), 0.1% formic acid) and a full-scan data-dependent MS2 (ddMS2) mode for substances identification (mass range 100-1000 m/z). The GC-MS method employed an ultra-Inert Intuvo GC column (HP-5MS UI, 30 m, 250 µm i.d, film thickness 0.25 µm; Agilent Technologies, Santa Clara, CA, USA) and electron-impact (EI) mass spectra were recorded in total ion monitoring mode (scan range 40-550 m/z). Urine samples from 296 patients with a history of opioid use disorder were examined. Around 80 different psychoactive substances and/or metabolites were identified, being methadone and metabolites the most prevalent ones. The possibility to screen for a huge number of psychotropic substances can be useful in suspected drug related fatalities or acute intoxication/exposure occurring in emergency departments and drug addiction services.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas , Psicotrópicos/orina , Analgésicos Opioides/orina , Cromatografía Líquida de Alta Presión , Humanos , Metadona/orina , Trastornos Relacionados con Sustancias/orina
6.
Int J Mol Sci ; 21(24)2020 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-33321929

RESUMEN

The consumption of synthetic cannabinoids (SCs) has significantly increased in the last decade and the analysis of SCs and their metabolites in human specimens is gaining interest in clinical and forensic toxicology. A pilot study has been carried out using a combination of an initial last generation gas chromatography-mass spectrometry (GC-MS) screening method for the determination of JWH-122, JWH-210, UR-144) in oral fluid (OF) of consumers and an ultra-high performance liquid chromatography high resolution mass spectrometry (UHPLC-HRMS) confirmatory method for the quantification of the parent compounds and their metabolites in the same biological matrix. OF samples were simply liquid-liquid extracted before injecting in both chromatographic systems. The developed methods have been successfully validated and were linear from limit of quantification (LOQ) to 50 ng/mL OF. Recovery of analytes was always higher than 70% and matrix effect always lower than 15% whereas intra-assay and inter-assay precision and accuracy were always better than 16%. After smoking 1 mg JWH-122 or UR-144 and 3 mg JWH-210, maximum concentration of 4.00-3.14 ng/mL JWH-122, 8.10-7.30 ng/mL JWH-210 ng/mL and 7.40 and 6.81 ng/mL UR-144 were measured by GC-MS and UHPLC-HRMS respectively at 20 min after inhalation. Metabolites of JWH 122 and 210 were quantified in OF by UHPLC-HRMS, while that of UR144 was only detectable in traces. Our results provide for the first time information about disposition of these SCs and their metabolites in consumers OF. Last generation GC-MS has proven useful tool to identify and quantify parent SCs whereas UHPLC-HRMS also confirmed the presence of SCs metabolites in the OF of SCs consumers.


Asunto(s)
Cannabinoides/farmacocinética , Indoles/farmacocinética , Naftalenos/farmacocinética , Saliva/metabolismo , Adulto , Cannabinoides/administración & dosificación , Cannabinoides/análisis , Cromatografía Liquida , Femenino , Humanos , Indoles/administración & dosificación , Indoles/análisis , Masculino , Fumar Marihuana/metabolismo , Espectrometría de Masas , Mucosa Bucal/metabolismo , Naftalenos/administración & dosificación , Naftalenos/análisis , Saliva/química
7.
Medicina (Kaunas) ; 56(8)2020 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-32823724

RESUMEN

Background and Objectives: The use of synthetic cannabinoids has increased around the world. As a result, the implementation of accurate analysis in human biological matrices is relevant and fundamental. Two different analytical technologies, ultra-high-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS) and high-sensitivity gas chromatography-mass spectrometry (GC-MS) were used for the determination of three synthetic cannabinoids JWH-122, JWH 210, UR-144 and their metabolites in urine of consumers. Materials and Methods: Sample preparation included an initial hydrolysis with ß-glucuronidase and liquid-liquid extraction. The UHPLC-HRMS method included a Kinetex 2.6 u Biphenyl 100A (100 × 2.1 mm, 2.6 µm) (Phenomenex, Italy) column with a gradient mobile phase consisting of mobile phase A (ammonium formate 2mM in water, 0.1% formic acid) and mobile phase B (ammonium formate 2mM in methanol/acetonitrile 50:50 (v/v), 0.1% formic acid) and a full-scan data-dependent MS2 (ddMS2) mode was used (mass range 100-1000 m/z). The GC-MS method employed an ultra-Inert Intuvo GC column (HP-5MS UI, 30 m × 250 µm i.d, film thickness 0.25 µm; Agilent Technologies, Santa Clara, CA, USA) and electron-impact (EI) mass spectra were recorded in total ion monitoring mode (scan range 40-550 m/z). Results: Both methods have been successfully used for screening of parent synthetic cannabinoids and their metabolites in urine samples of consumers. Conclusions: The screening method applied JWH-122, JWH-210, UR-144 and their metabolites in urine of consumers can be applied to other compounds of the JWH family.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Drogas Ilícitas/orina , Indoles/orina , Naftalenos/orina , Humanos , Reproducibilidad de los Resultados
8.
Int J Legal Med ; 131(6): 1543-1553, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28710651

RESUMEN

The acute and chronic toxicity of several new psychoactive substances (NPS) is unknown, and only little information is available on the pharmacology and toxicology, toxicokinetics, and detectability in body samples of such new compounds. We here propose analytical methods to disclose acute and chronic use of two types of new psychostimulants: benzofurans and ethylphenidate and we applied them to a real case of a subject attending Emergency Department with signs of acute intoxication due to psychotropic drug(s). After a urinary immunoassay screening which gave a positivity to amphetamines, general unknown gas chromatography-mass spectrometry (GC-MS) urine analysis identified 5-(2-methylaminopropyl)benzofuran (5-MAPB), 5-(2-aminopropyl)benzofuran (5-APB), 5-(2-ethylaminopropyl)benzofuran (5-EAPB), ethylphenidate, and ritalinic acid. All these substances were confirmed and quantified not only in urine but also in serum samples at different times after hospitalization by GC-MS and ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Two subsequent 2-cm hair segments were also analyzed and tested positive for the above reported substances, evidencing repeated use. The matching quantitative results in all the analyzed biological matrices demonstrated that both analytical methodologies were suitable to correctly quantify NPS involved in the current intoxication. The objective assessment of acute and chronic intoxication by the above reported compounds demonstrate that the development of analytical methods aiming at the detection of a broad spectrum of compounds in conventional and non-conventional biological matrices is helpful when facing the new challenging threat of intoxications caused by NPS.


Asunto(s)
Benzofuranos/análisis , Cabello/química , Metilfenidato/análogos & derivados , Psicotrópicos/análisis , Detección de Abuso de Sustancias/métodos , Trastornos Relacionados con Sustancias/diagnóstico , Benzofuranos/efectos adversos , Cromatografía Líquida de Alta Presión , Cromatografía de Gases y Espectrometría de Masas , Humanos , Inmunoensayo , Masculino , Metilfenidato/efectos adversos , Metilfenidato/análisis , Psicotrópicos/efectos adversos , Espectrometría de Masas en Tándem , Adulto Joven
9.
Clin Chem Lab Med ; 55(10): 1555-1563, 2017 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-28207408

RESUMEN

BACKGROUND: Cannabis has been used since ancient times to relieve neuropathic pain, to lower intraocular pressure, to increase appetite and finally to decrease nausea and vomiting. The combination of the psychoactive cannabis alkaloid Δ9-tetrahydrocannabinol (THC) with the non-psychotropic alkaloids cannabidiol (CBD) and cannabinol (CBN) demonstrated a higher activity than THC alone. The Italian National Institute of Health sought to establish conditions and indications on how to correctly use nationally produced cannabis to guarantee therapeutic continuity in individuals treated with medical cannabis. METHODS: The evaluation of cannabinoids concentration and stability in standardized preparations of cannabis tea and cannabis oil was conducted using an easy and fast ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) assay. RESULTS: Extraction efficiency of oil was significantly higher than that of water with respect to the different cannabinoids. This was especially observed in the case of the pharmacologically active THC, CBD and their acidic precursors. Fifteen minutes boiling was sufficient to achieve the highest concentrations of cannabinoids in the cannabis tea solutions. At ambient temperature, a significant THC and CBD decrease to 50% or less of the initial concentration was observed over 3 and 7 days, respectively. When refrigerated at 4 °C, similar decreasing profiles were observed for the two compounds. The cannabinoids profile in cannabis oil obtained after pre-heating the flowering tops at 145 °C for 30 min in a static oven resulted in a complete decarboxylation of cannabinoid acids CBDA and THCA-A. Nevertheless, it was apparent that heat not only decarboxylated acidic compounds, but also significantly increased the final concentrations of cannabinoids in oil. The stability of cannabinoids in oil samples was higher than that in tea samples since the maximum decrease (72% of initial concentration) was observed in THC coming from unheated flowering tops at ambient temperature. In the case of the other cannabinoids, at ambient and refrigerated temperatures, 80%-85% of the initial concentrations were measured up to 14 days after oil preparation. CONCLUSIONS: As the first and most important aim of the different cannabis preparations is to guarantee therapeutic continuity in treated individuals, a strictly standardized preparation protocol is necessary to assure the availability of a homogeneous product of defined stability.


Asunto(s)
Cannabinoides/análisis , Cromatografía Líquida de Alta Presión , Aceites de Plantas/química , Espectrometría de Masas en Tándem , Té/química , Cannabinoides/aislamiento & purificación , Cannabinoides/normas , Cannabis/química , Cannabis/metabolismo , Cromatografía Líquida de Alta Presión/normas , Estándares de Referencia , Espectrometría de Masas en Tándem/normas , Temperatura
10.
J Antimicrob Chemother ; 71(4): 1027-30, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26679247

RESUMEN

OBJECTIVES: To evaluate antiretroviral drug concentrations in mothers and infants enrolled under the Option B-Plus approach for the prevention of HIV mother-to-child transmission in Malawi and to assess the maternal virological response after 1 year of treatment. PATIENTS AND METHODS: Forty-seven women and 25 children were studied. Mothers were administered during pregnancy a combination of tenofovir, lamivudine and efavirenz and continued it during breastfeeding (up to 2 years) and thereafter. Drug concentrations were evaluated in mothers (plasma and breast milk) at 1 and 12 months post-partum and in infants (plasma) at 6 and 12 months of age. Drug concentrations were determined using an LC-MS/MS validated methodology. RESULTS: In breast milk, tenofovir concentrations were very low (breast milk/maternal plasma ratio = 0.08), while lamivudine was concentrated (breast milk/plasma ratio = 3) and efavirenz levels were 80% of those found in plasma. In infants, median levels at 6 months were 24 ng/mL tenofovir, 2.5 ng/mL lamivudine and 86.4 ng/mL efavirenz. At month 12, median levels were below the limit of quantification for the three drugs. No correlation was found between drug concentrations and laboratory parameters or indices of growth. HIV-RNA >1000 copies/mL was seen at month 1 in 15% of the women and at month 12 in 8.5%. Resistance was found in half of the women with detectable viral load. CONCLUSIONS: Breastfeeding infants under Option B-Plus are exposed to low concentrations of antiretroviral drugs. With this strategy, mothers had a good virological response 1 year after delivery.


Asunto(s)
Terapia Antirretroviral Altamente Activa , Benzoxazinas/farmacocinética , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/transmisión , Transmisión Vertical de Enfermedad Infecciosa/prevención & control , Lamivudine/farmacocinética , Tenofovir/farmacocinética , Adulto , Alquinos , Recuento de Linfocito CD4 , Cromatografía Liquida , Ciclopropanos , Femenino , Infecciones por VIH/diagnóstico , Humanos , Lactante , Malaui , Embarazo , Complicaciones Infecciosas del Embarazo , Espectrometría de Masas en Tándem , Carga Viral , Adulto Joven
11.
Clin Chem Lab Med ; 54(3): 427-35, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26351940

RESUMEN

BACKGROUND: In recent years, fatty acid ethyl esters (FAEEs) and ethyl glucuronide (EtG) in meconium emerged as reliable, direct biological markers for establishing gestational ethanol exposure. We investigated whether EtG in maternal hair measured during the three trimesters of pregnancy correlated with EtG and FAEEs in neonatal meconium. METHODS: In a prospective sample of 80 mother-infant dyads from Barcelona (Spain), we measured EtG and FAEE in maternal hair segments and meconium samples using a validated UHPLC-MS/MS method. RESULTS: Fifty-eight (72.5%) women had EtG concentrations in the hair shafts >7 pg/mg in one or more pregnancy trimesters, and EtG and FAEEs in meconium samples were documented in 50 and 24 of their neonates, respectively. The best significant correlations (p<0.0001) were found between EtG concentration in the proximal 0-3 and 3-6 hair shaft segments corresponding to the last two pregnancy trimesters and EtG in neonatal meconium (ρ=0.609 and ρ=0.577, respectively). Using the combination of EtG in meconium ≥30 ng/g and a median of EtG >11 pg/mg in maternal hair during the second and third trimesters of pregnancy, prenatal ethanol exposure could be predicted with a sensitivity of 85.7% and specificity of 73.7%. CONCLUSIONS: This study provides evidence of proven fetal exposure to ethanol during the second and third trimesters of pregnancy by linking detection of ethanol biomarkers (EtG) in maternal hair segments and EtG in neonatal meconium.


Asunto(s)
Consumo de Bebidas Alcohólicas , Biomarcadores/química , Glucuronatos/análisis , Cabello/química , Meconio/química , Adulto , Cromatografía Liquida , Femenino , Humanos , Recién Nacido , Embarazo , Trimestres del Embarazo , Espectrometría de Masas en Tándem
12.
Adicciones ; 28(3): 158-62, 2016 Jun 15.
Artículo en Inglés, Español | MEDLINE | ID: mdl-27399225

RESUMEN

This study presents the case of a 4-year-old healthy child admitted to the paediatric ward for suspected accidental intoxication due to ingestion of narcoleptic drugs (methylphenidate, sertraline and quetiapine), taken on a regular basis by his 8-year-old brother affected by Asperger syndrome.Intoxication can be objectively assessed by measurements of drugs and metabolites in biological matrices with short-term (blood and urine) or long-term (hair) detection windows. At the hospital, the child's blood and urine were analysed by immunoassay (confirmed by liquid chromatography-mass spectrometry), and sertraline and quetiapine and their metabolites were identified. The suspicion that the mother administered drugs chronically prompted the analysis of six, consecutive 2-cm segments of the child's hair, using ultra-high performance liquid chromatography-tandem mass spectrometry, thereby accounting for ingestion over the previous 12 months. Quetiapine was found in the first four segments with a mean concentration of 1.00 ng/mg ± 0.94 ng/mg hair while sertraline and its metabolite, desmethyl-sertraline, were found in all segments with a mean concentration of 2.65 ± 0.94 ng/mg and 1.50 ± 0.94 ng/mg hair, respectively. Hair analyses were negative for methylphenidate and its metabolite (ritalinic acid). Biological matrices testing for psychoactive drugs disclosed both acute and chronic intoxication with quetiapine and sertraline administered by the mother.


Se presenta el caso de un niño sano de 4 años de edad que ingresa en la sala de hospitalización pediátrica por la sospecha de una intoxicación accidental debido a la ingesta de fármacos narcolépticos (metilfenidato, sertralina y quetiapina), que tomaba de forma pautada su hermano de 8 años de edad que padecía un síndrome de Asperger.La evaluación objetiva de la intoxicación se puede realizar con la determinación de los fármacos y sus metabolitos en matrices biológicas con una ventana de tiempo corta (sangre y orina) o larga (pelo).En el hospital se realizó un análisis de sangre y orina mediante inmunoanálisis (confirmado mediante espectrometría líquida-cromatografía de masas) y se identificó la presencia de sertralina y quetiapina y sus metabolitos. Con la sospecha de administración crónica de fármacos al niño, se procedió al análisis del pelo con cromatografía líquida de ultra-alto rendimiento-espectrometría de masas en tándem. El pelo se dividió en 6 segmentos consecutivos de 2 cm de longitud, de forma que permitieron estudiar la ingesta de los fármacos durante los últimos 12 meses. En los primeros 4 segmentos se encontró quetiapina con una concentración media de 1,00 ng/mg ± 0,94 ng/mg de pelo y en todos los segmentos se encontraron sertralina y su metabolito, desmetil-sertralina, con una concentración media de 2,65 ± 0,94 ng/mg y 1,50 ± 0,94 ng/mg de pelo, respectivamente. El análisis de pelo resultó negativo para metilfenidato y su metabolito (ácido ritalínico).La detección en matrices biológicas de fármacos psicoactivos demostró la intoxicación aguda y crónica por quetiapina y sertralina, administradas por la madre.


Asunto(s)
Cabello/química , Psicotrópicos/análisis , Psicotrópicos/envenenamiento , Preescolar , Humanos , Masculino
15.
Clin Chem Lab Med ; 52(5): 679-86, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24285127

RESUMEN

BACKGROUND: Drug testing in hair is a unique analysis in pharmacotoxicology for establishing a past repeated history of consumption or passive exposure to psychotropic substances. A rather lengthy sample treatment is usually required before parent drugs and eventual metabolites are amenable to quali-quantitative analysis. METHODS: We evaluated a high throughput screening and confirmation analysis of drugs of abuse in hair by immunoassay and a validated ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) after applying a rapid digestion of the keratin matrix with VMA-T reagent before screening assay and M3 reagent before confirmatory analysis. RESULTS: Samples digestion with VMA-T reagent and immunometric screening analysis of hair calibrators, controls and clinical samples for a total of 150 samples was completed in 4 h. No false-positive and -negative results were found for the control material. UPLC-MS/MS analysis confirmed all of the 31 adult hair samples positive to the screening test using internationally established cut-offs, and identified and quantified drugs of abuse in 32 pediatric hair samples, applying lower limits of quantification from 0.01 to 0.1 ng analyte per mg hair. Analytical recovery was between 70.9% and 100.7%. Intra- and inter-assay imprecision and inaccuracy were always lower than 10%. CONCLUSIONS: Rapid extraction, identification and quantification of drugs of abuse in hair by immunoassay and UPLC-MS/MS was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in hair in epidemiological studies.


Asunto(s)
Cromatografía Líquida de Alta Presión , Drogas Ilícitas/análisis , Inmunoensayo , Espectrometría de Masas en Tándem , Cabello/química , Humanos , Queratinas/química
16.
J Pharm Biomed Anal ; 243: 116084, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38452420

RESUMEN

In 2019, Italian National Institute of Health established an external quality assessment program (EQA) to evaluate the performance of oral fluid testing for classical and new psychoactive substances by laboratories participating in the National Early Warning System collaborative centres. This report presents the results of four rounds between 2019 and 2023. Eleven oral fluid specimens, including 3 blank samples, were prepared by adding different classes of and new psychoactive drugs at known concentrations to pre-screened drug-free oral fluid. False-negative and false-positive results were calculated for the qualitative data evaluation. The quantitative evaluation measured the imprecision and accuracy of the results, in terms of coefficient of variation (CV%) and percent error (ERR%), respectively, with respect to a mean value obtained by reference laboratories. Z-score values were then calculated. Over the years, there has been a significant improvement in false-negative results (from 42.7% in the first year to 19.4% in the last year), but not in false-positive results (from 33.3% in the first year to 22.2% in the last one). In addition to the classic drugs of abuse (e.g. cocaine, amphetamine, methadone), the substances found in false positive samples belonged to the class of synthetic cannabinoids (e.g 5-fluoro CUMYL-PINACA and 5-fluoro-EDMB-PICA), synthetic opioids (e.g butyrylfentanyl) and tryptamines (e.g. 5-methoxy-N-methyl-N-isopropyltryptamine). The four rounds yielded a mean ERR% of approximately 22.1% and a mean CV% of around 41.5%. The participating laboratories demonstrated variable performances in relation to the class of analysed psychoactive substances, as evidenced by the calculated Z-scores. Between 25% and 60% of the reported results in all rounds should be considered satisfactory. EQA is a crucial element of laboratory quality management systems. It promotes continuous improvement and maintains high standards in the field of forensic and clinical drug testing.


Asunto(s)
Cannabinoides , Cocaína , Fármacos del Sistema Nervioso Central , Italia , Cocaína/análisis , Cannabinoides/análisis , Triptaminas
17.
J Pharm Biomed Anal ; 243: 116100, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38513500

RESUMEN

In 2019, the Italian National Institute of Health established an external quality assessment (EQA) program to evaluate the performance of laboratories of collaborative centres participating in the National Early Warning System in hair testing for classical and new psychoactive substances (NPS). The results obtained in the four rounds (2019-2023) and the evolution in hair testing performance for classic drugs of abuse and new psychoactive substances are presented. A total of 11 hair specimens, including 3 blank samples, were prepared by adding different classes of classical and NPS at known concentrations to pre-screened drug-free hair. False negative and false positive results were calculated for the qualitative data evaluation. The quantitative evaluation included the imprecision (as % coefficient of variation, CV%) and the accuracy (as % error, ERR%) of the results with respect to a mean value obtained by reference laboratories and Z-score values were assessed. Over the years, an improvement in false negative results (from 52.4% in the first year to 34.3% in the last one) and false positive results (from 55.0% in the first year to 30.8.% in the last one) was observed. In the first round, the mean ERR% ranged from 6.2% to 112.8% due to NPS determination. However, in the subsequent three rounds, the mean ERR% ranged from 10.4% to 22.4%, The mean CV% in the four rounds was approximately 41.5% (ranging from 44.3% to 53.3%). Between 12.0% and 56.6% of the reported results in all rounds should be considered satisfactory. EQA programs help laboratories to identify and correct problems within their processes by highlighting errors and variations. This ensures that the results produced are accurate and reproducible.


Asunto(s)
Fármacos del Sistema Nervioso Central , Cabello , Italia
18.
J Pharm Biomed Anal ; 241: 115994, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38309098

RESUMEN

Forensic laboratories are constantly required to identify new drugs and their metabolites. N-ethylhexedrone (NEH, HEXEN), N-Ethylpentedrone (NEP), and 4-Chloromethcathinone (4-CMC, clephedrone) are synthetic substances structurally related to natural cathinone, alkaloid present in the leaves of the Catha edulis (Khat) plant. These synthetic cathinones (SC) are members of the heterogenous family of new psychoactive substances (NPS) that raised major concerns in scientific and forensic communities over the past years due to their widespread consumption. In this context, we investigated their metabolic profile using of UHPLC-QTOF-HRMS to elucidate the distribution of the parent drug and its metabolites in urine samples over time. Initially, both male and female volunteers were divided into three groups and eight subjects of each group were administered intranasally or orally with one SC (20-40 mg of NEH or NEP intranasal, 100-150 mg of 4-CMC oral). Urine samples were collected at 0-2 and 2-4 or 2-5 h. Urine (50 µL) was diluted 1:2 with acetonitrile/methanol (95:5) and injected into the UHPLC-QTOF-HRMS. Phase-I and phase-II metabolites were identified on the basis of fragmentation patterns and exact masses. Several phase-I and glucuronide-phase-II metabolites were identified in urine samples. Keto group reduction, hydroxylation and dealkylation were the common metabolic pathways identified for all cathinones and the presence of NEH-glucuronide, NEP-glucuronide and 4-CMC-glucuronide was also relevant. Significant is the slower metabolite formation for 4-CMC, which was detected at high concentrations in its original form even 5 h after administration, due to its long half-life and low intrinsic clearance compared to the other SCs. UHPLC-QTOF-HRMS demonstrated a considerable capability to semi-quantify the three synthetic cathinones and identify the target metabolites with high reliability. The introduction of new target compounds improves the efficiency of toxicological screening analysis on real samples and extends the window of detection of the SCs in biological matrices.


Asunto(s)
Glucurónidos , Metilaminas , Propiofenonas , Cathinona Sintética , Humanos , Cromatografía Líquida de Alta Presión , Reproducibilidad de los Resultados , Metaboloma
19.
Ther Drug Monit ; 35(3): 402-7, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23666568

RESUMEN

BACKGROUND: The deleterious effects exerted by prenatal ethanol exposure include physical, mental, behavioral, and/or learning disabilities that are included in the term fetal alcohol spectrum disorder. The measurement of ethylglucuronide (EtG) in alternative biological matrices, including neonatal and maternal hair, neonatal meconium, and maternal nails, is receiving increasing interest for the accurate evaluation of the in utero exposure to alcohol. OBJECTIVE: To evaluate the correlation between EtG in maternal hair and nails with EtG in neonatal meconium to further explore the suitability of these biomarkers in disclosing prenatal exposure to ethanol. METHODS: A total of 151 maternal hair strands (0-6 cm), nail clips (2-6 mm), and corresponding neonatal meconium and nails samples were obtained from neonatal wards of 4 Mediterranean public hospitals: Rome, Florence, and Belluno in Italy and Barcelona in Spain. Hair, nails, and meconium were analyzed for the presence of EtG by validated liquid chromatography mass spectrometry assay. Meconium was also analyzed for the presence of fatty acid ethyl esters (FAEEs) as a complementary biomarker of potential in utero exposure to alcohol. RESULTS: Eighteen newborns resulted in utero exposed to maternal alcohol consumption by FAEE testing in meconium with EtG values between 0.5 and 1.5 nmol/g. Unfortunately, none of these cases were confirmed by the presence of EtG in maternal hair and nails samples, which resulted all negative to this biomarker. DISCUSSION AND CONCLUSIONS: The results confirm that FAEEs and EtG in meconium are the best biomarkers to assess in utero exposure to maternal alcohol. EtG in hair and nails are not good biomarkers to disclose alcohol consumption lower than on daily basis and lower than 1-2 alcoholic units per day.


Asunto(s)
Consumo de Bebidas Alcohólicas/metabolismo , Etanol/metabolismo , Glucuronatos/análisis , Meconio/química , Consumo de Bebidas Alcohólicas/efectos adversos , Biomarcadores/análisis , Cromatografía Liquida/métodos , Ésteres/análisis , Etanol/efectos adversos , Ácidos Grasos/análisis , Femenino , Trastornos del Espectro Alcohólico Fetal/diagnóstico , Cabello/química , Humanos , Recién Nacido , Espectrometría de Masas/métodos , Exposición Materna , Uñas/química , Embarazo
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda