Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Epilepsia ; 64(10): 2827-2840, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37543852

RESUMEN

OBJECTIVE: Posttranscriptional mechanisms are increasingly recognized as important contributors to the formation of hyperexcitable networks in epilepsy. Messenger RNA (mRNA) polyadenylation is a key regulatory mechanism governing protein expression by enhancing mRNA stability and translation. Previous studies have shown large-scale changes in mRNA polyadenylation in the hippocampus of mice during epilepsy development. The cytoplasmic polyadenylation element-binding protein CPEB4 was found to drive epilepsy-induced poly(A) tail changes, and mice lacking CPEB4 develop a more severe seizure and epilepsy phenotype. The mechanisms controlling CPEB4 function and the downstream pathways that influence the recurrence of spontaneous seizures in epilepsy remain poorly understood. METHODS: Status epilepticus was induced in wild-type and CPEB4-deficient male mice via an intra-amygdala microinjection of kainic acid. CLOCK binding to the CPEB4 promoter was analyzed via chromatin immunoprecipitation assay and melatonin levels via high-performance liquid chromatography in plasma. RESULTS: Here, we show increased binding of CLOCK to recognition sites in the CPEB4 promoter region during status epilepticus in mice and increased Cpeb4 mRNA levels in N2A cells overexpressing CLOCK. Bioinformatic analysis of CPEB4-dependent genes undergoing changes in their poly(A) tail during epilepsy found that genes involved in the regulation of circadian rhythms are particularly enriched. Clock transcripts displayed a longer poly(A) tail length in the hippocampus of mice post-status epilepticus and during epilepsy. Moreover, CLOCK expression was increased in the hippocampus in mice post-status epilepticus and during epilepsy, and in resected hippocampus and cortex of patients with drug-resistant temporal lobe epilepsy. Furthermore, CPEB4 is required for CLOCK expression after status epilepticus, with lower levels in CPEB4-deficient compared to wild-type mice. Last, CPEB4-deficient mice showed altered circadian function, including altered melatonin blood levels and altered clustering of spontaneous seizures during the day. SIGNIFICANCE: Our results reveal a new positive transcriptional-translational feedback loop involving CPEB4 and CLOCK, which may contribute to the regulation of the sleep-wake cycle during epilepsy.


Asunto(s)
Proteínas CLOCK , Epilepsia Refractaria , Epilepsia del Lóbulo Temporal , Melatonina , Proteínas de Unión al ARN , Estado Epiléptico , Animales , Humanos , Masculino , Ratones , Epilepsia del Lóbulo Temporal/metabolismo , Hipocampo , Melatonina/sangre , ARN Mensajero/metabolismo , Proteínas de Unión al ARN/genética , Proteínas de Unión al ARN/metabolismo , Convulsiones , Estado Epiléptico/inducido químicamente , Estado Epiléptico/genética , Factores de Transcripción/metabolismo , Proteínas CLOCK/genética
2.
Eye Contact Lens ; 49(3): 120-126, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36700614

RESUMEN

PURPOSE: To evaluate the effect of the topical instillation of hyaluronic acid eye drops with different viscosity on soft contact lens wettability and comfort. METHODS: A randomized and participant-masked study was performed, involving 20 participants (25.4±2.6 years). One eye wore hydrogel (ocufilcon D) contact lenses, and another eye wore silicone-hydrogel (somofilcon A) contact lenses. The in vivo wettability tear film surface quality (TFSQ) index and comfort were measured before and after the instillation of different eye drops: saline solution (control) and 0.1%, 0.2%, and 0.3% hyaluronic acid. RESULTS: Compared with saline solution, the instillation of 0.1%, 0.2%, and 0.3% hyaluronic acid improved the in vivo wettability of the hydrogel contact lenses by decreasing their TFSQ mean for 5, 10, and 30 min, respectively ( P <0.05). During silicone-hydrogel contact lens wear, the hyaluronic acid did not affect wettability because there were no changes in TFSQ mean ( P ≥0.05), but the 0.3% hyaluronic acid produced a decrease in comfort for the first 3 min ( P <0.05). CONCLUSIONS: The instillation of hyaluronic acid eye drops increased the in vivo wettability of the hydrogel contact lens, and the duration of this effect was directly related to its concentration and viscosity.


Asunto(s)
Lentes de Contacto Hidrofílicos , Ácido Hialurónico , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Hidrogeles , Soluciones Oftálmicas , Solución Salina , Siliconas , Humectabilidad
3.
Int J Mol Sci ; 22(21)2021 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-34769429

RESUMEN

(1) Background: Artemia salina is a brine shrimp containing high concentrations of dinucleotides, molecules with properties for dry eye treatment. For this reason, the purpose of the study was to evaluate the effect of the artificial tears based on an extract of Artemia salina in a rabbit dry eye model. (2) Methods: A prospective and randomized study was carried out. Twenty rabbits were divided into 4 groups (n = 5, each group): healthy rabbits, dry eye rabbits, dry eye rabbits treated with hypromellose (HPMC), and dry eye rabbits treated with Artemia salina. Dry eye was induced by the topical instillation of 0.2% benzalkonium chloride. The measurements were performed before and after the treatment for 5 consecutive days. (3) Results: The topical instillation of artificial tears containing Artemia salina showed beneficial effects on tear secretion, tear break-up time, corneal staining, the density of Goblet cells, heigh of mucin cloud secreted by these cells, and mRNA levels of IL-1ß and MMP9 in conjunctival cells. Compared with the HPMC, there was a statistically significant improvement (p < 0.05) with the Artemia salina in all the variables under study, except for the conjunctival hyperemia, density of Goblet cells, and mRNA levels of IL-6. (4) Conclusions: The potential of artificial tears based on Artemia salina as a secretagogue agent for dry eye treatment was confirmed, opening the door for future clinical trials and studies to extrapolate the findings for dry eye patients.


Asunto(s)
Artemia/química , Fosfatos de Dinucleósidos/farmacología , Síndromes de Ojo Seco/tratamiento farmacológico , Derivados de la Hipromelosa/farmacología , Gotas Lubricantes para Ojos/administración & dosificación , Extractos Vegetales/farmacología , Lágrimas/efectos de los fármacos , Animales , Modelos Animales de Enfermedad , Síndromes de Ojo Seco/metabolismo , Masculino , Conejos , Lágrimas/metabolismo
4.
Eye Contact Lens ; 44 Suppl 1: S307-S311, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28945652

RESUMEN

OBJECTIVE: To compare, in terms of efficacy, the differences between the use of saline solution and a viscous artificial tear to fill the lens during the first month of orthokeratology wear. METHODS: A pilot, double-masked, crossed, randomized, and prospective study was conducted. In this study, 20 subjects (14 males and 6 females) with a mean age of 16.29±6.22 years (range, 10-26) were fitted with orthokeratology contact lenses. For the study, nonpreserved 0.9% NaCl commercial saline solution (Avizor, Madrid, Spain) and nonpreserved artificial teardrops with 0.3% of hyaluronic acid (Ocudry 0.3%; Avizor, Madrid, Spain) were used. Corneal staining, tear break up time (TBUT), topography, refraction, visual acuity, and subjective comfort and vision with the visual analog scale (score from 0 to 10, being 10 better comfort and vision) were evaluated at 1 day, 1 week, and 1 month of contact lens wear. RESULTS: The corneal staining was statistically greater in the saline group than in the Ocudry group for the first day and during 1 week of wear (P<0.05). Comfort was found to be statistically better, with Ocudry 0.3% than saline solution, being 7.17±1.94 and 6.37±1.63, for the first day, and 8.78±0.43 and 8.15±0.62 for the day 28, respectively (P<0.05). However, no differences were found for subjective vision scores, TBUT, spherical equivalent, best-corrected visual acuity and uncorrected visual acuity, and mean keratometry between groups for any visit (P>0.05). CONCLUSION: Viscous artificial tears improve the subjective comfort of patients and reduce the corneal staining, compared with saline solution during the orthokeratology lenses fitting process. However, no differences between solutions for the treatment efficacy, in vision and corneal topography, were found.


Asunto(s)
Lentes de Contacto , Córnea/patología , Miopía/terapia , Procedimientos de Ortoqueratología/métodos , Refracción Ocular/fisiología , Cloruro de Sodio/administración & dosificación , Agudeza Visual , Adolescente , Adulto , Niño , Córnea/metabolismo , Topografía de la Córnea , Estudios Cruzados , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Gotas Lubricantes para Ojos/administración & dosificación , Gotas Lubricantes para Ojos/química , Masculino , Miopía/patología , Miopía/fisiopatología , Estudios Prospectivos , Lágrimas/química , Factores de Tiempo , Viscosidad , Adulto Joven
5.
Eye Contact Lens ; 43(6): 346-351, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27203795

RESUMEN

OBJECTIVE: To evaluate the ocular surface temperature using an infrared thermography camera before and after wearing scleral lens in patients with keratoconus and correlate these results with the tear production and stability. METHODS: A pilot, experimental, short-term study has been performed. Twenty-six patients with keratoconus (36.95±8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (KC-ICRS group) and patients without ICRS (KC group). Schirmer test, tear breakup time (TBUT), and ocular surface temperature in the conjunctiva, limbus, and cornea were evaluated before and after wearing a scleral lens. RESULTS: The patients wore the scleral lenses from 6 to 9 hours with average of 7.59±0.73 hours. No significant changes in Schirmer test and TBUT were found for both groups. No temperature differences were found between the KC-ICRS and the KC groups for all zones evaluated. There was a slight, but statistically significant, increase in the inferior cornea, temporal limbus, and nasal conjunctival temperature for KC-ICRS group and temporal limbus temperature decreasing for the KC group after wearing scleral lens (P<0.05). The conjunctiva and limbus temperature was statistically higher than the central cornea for both groups before and after scleral lenses wearing (P<0.05), but no difference in the peripheral cornea was found. No statistically significant differences in the central corneal temperature were found between the groups after scleral lens wearing (P>0.05). CONCLUSION: Scleral contact lens seems not to modify the ocular surface temperature despite the presence of the tear film stagnation under the lens.


Asunto(s)
Temperatura Corporal/fisiología , Conjuntiva/fisiología , Lentes de Contacto , Córnea/fisiología , Queratocono/terapia , Prótesis e Implantes , Esclerótica , Adulto , Femenino , Humanos , Queratocono/metabolismo , Limbo de la Córnea/fisiología , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Lágrimas/metabolismo , Termografía/métodos
6.
Optom Vis Sci ; 93(2): 150-7, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26657697

RESUMEN

PURPOSE: To evaluate the most important signs of dry eye, such as osmolarity, inflammation, and diadenosine tetraphosphate (Ap(4)A) concentration before and after wearing scleral lenses for 8 h in keratoconus patients. METHODS: A pilot, experimental, short-term study involved 26 keratoconus patients (average age, 36.95 ± 8.95 years). They voluntarily enrolled in the study at the Optometry Clinic of the Faculty of Optics and Optometry in the University Complutense of Madrid. They were divided into two groups: patients with intrastromal corneal ring, the ICRS group, and patients without ICRS, the keratoconus (KC) group. Ocular Surface Disease Index questionnaire, the Schirmer test without anesthesia, tear break-up time, matrix metalloproteinase 9 (MMP-9) concentration, osmolarity, and Ap4A concentration were evaluated before and after wearing a scleral lens for 8 h. RESULTS: The patients wore the scleral lenses from 6 to 9 h, with a mean of 7.59 ± 0.73 h. The mean scleral lens sag for all patients was 4310 ± 166.31 µm, ranging from 4200 µm to 4800 µm. No significant changes in the Schirmer test and tear break-up time were found for either group. Ocular Surface Disease Index scores were statistically lower after wearing scleral lenses for both groups (p < 0.05). A significantly lower osmolarity and a significant rise of MMP-9 concentration after wearing scleral lenses were found in both groups (p < 0.05). Diadenosine tetraphosphate concentration was lower after wearing the scleral lens in the KC group (p < 0.05) but no significant difference was found for the ICRS group (p > 0.05). CONCLUSIONS: Short-term scleral lens wearing improves the symptomatology and some signs of dry eye, such as osmolarity and Ap4A concentration. The increase of MMP-9 concentration could be caused by tear film stagnation and use of preserved saline.


Asunto(s)
Lentes de Contacto , Síndromes de Ojo Seco/diagnóstico , Queratocono/terapia , Esclerótica , Lágrimas/fisiología , Adulto , Biomarcadores/metabolismo , Sustancia Propia/cirugía , Fosfatos de Dinucleósidos/metabolismo , Síndromes de Ojo Seco/metabolismo , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Queratocono/metabolismo , Masculino , Metaloproteinasa 9 de la Matriz/metabolismo , Persona de Mediana Edad , Concentración Osmolar , Prótesis e Implantes , Ajuste de Prótesis , Implantación de Prótesis , Encuestas y Cuestionarios , Lágrimas/química
7.
Eye Contact Lens ; 42(5): 280-8, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26372476

RESUMEN

Dry eye disease affects a substantial segment of the word population with increasing frequency. It is a multifactorial disease of the ocular surface and tear film, which causes ocular discomfort, visual disturbances, and tear instability with potential damage to the cornea and conjunctiva. Because of its multifactorial etiology, the use of different pharmacological treatment for dry eye treatment has been proposed, which include anti-inflammatory molecules, lubricants or comfort agents, and secretagogues. However, in some cases these pharmacological approaches only relieve symptoms temporarily, and consequently, eye care professionals continue to have difficulties managing dry eye. To improve pharmacological therapy that allows a more efficient and long-term action, effective ocular drug delivery of the currently available drugs for dry eye treatment is required. Contact lenses are emerging as alternative ophthalmic drugs delivery systems that provide an increased residence time of the drug at the eye, thus leading to enhanced bioavailability and more convenient and efficacious therapy. In this article, we reviewed the different techniques used to prepare contact lens-based drug delivery systems and focused on articles that describe the delivery of compounds for dry eye treatment through contact lenses.


Asunto(s)
Antiinflamatorios/administración & dosificación , Lentes de Contacto , Sistemas de Liberación de Medicamentos/métodos , Síndromes de Ojo Seco/tratamiento farmacológico , Soluciones Oftálmicas/administración & dosificación , Agentes Mojantes/administración & dosificación , Disponibilidad Biológica , Conjuntiva/efectos de los fármacos , Córnea/efectos de los fármacos , Fosfatos de Dinucleósidos/administración & dosificación , Humanos
8.
Eye Contact Lens ; 42(2): 108-14, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25943051

RESUMEN

OBJECTIVES: To evaluate neophyte contact lens wearers' fitting to rigid gas permeable (RGP) contact lenses in terms of wearing time, tear volume, stability, corneal staining, and subjective ratings, over a 1-month period of time. METHODS: Twenty-two young healthy subjects were enrolled for wearing RGP on a daily wear basis. The participants included in this study never wore contact lenses and showed a value under 10 in McMonnies Questionnaire. Contact Lens Dry Eye Questionnaire, Visual Analog Scales, Schirmer test, tear film break-up time (BUT), and corneal staining grading were performed. Follow-up visits were scheduled at 1, 7, 15, and 28 days. RESULTS: Six subjects dropped out due to discomfort from the study before 1 month (27% of discontinuation rate). Successful RGP wearers (16 participants) achieved high levels of subjective vision and reported comfort scores of approximately 9 of 10 between 10 and 15 days. They reported wearing their lenses for an average of 10.12±2.43 hr after 1 month of wear. Conversely, unsuccessful wearers discontinued wearing the lenses after the first 10 to 15 days, showing comfort scores and wearing time significantly lower compared with the first day of wear. Schirmer test showed a significant increase at 10 days (P<0.001), and the BUT trends decreased after the first week of wear in unsuccessful group. CONCLUSIONS: Symptomatology related with dryness and discomfort, detected during the first 10 days of the adaptation, may help the clinician to predict those participants who will potentially fail to adapt to RGP lens wear.


Asunto(s)
Lentes de Contacto/efectos adversos , Síndromes de Ojo Seco/etiología , Dolor Ocular/etiología , Adulto , Córnea/patología , Síndromes de Ojo Seco/metabolismo , Síndromes de Ojo Seco/patología , Femenino , Humanos , Masculino , Satisfacción del Paciente , Lágrimas/metabolismo , Agudeza Visual , Adulto Joven
9.
J Pharmacol Exp Ther ; 345(3): 331-41, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23504005

RESUMEN

The presence and activity of nucleotides and dinucleotides in the physiology of most, if not all, organisms, from bacteria to humans, have been recognized by the scientific community, and the eye is no exception. Nucleotides in the dynamic fluids interact with many ocular structures, such as the tears and aqueous humor. Moreover, high concentrations of nucleotides in these secretions may reflect disease states such as dry eye and glaucoma. Apart from the nucleotide concentration in these fluids, P2 purinergic receptors have been described on the ocular surface (cornea and conjunctiva), anterior pole (ciliary body, trabecular meshwork), and posterior pole (retina). P2X and P2Y purinergic receptors are essential in maintaining the homeostasis of ocular processes, such as tear secretion, aqueous humor production, or retinal modulation. When they are functioning properly, they allow the eye to do its job (to see), but in some cases, a lack or an excess of nucleotides or a malfunction in the corresponding purinergic receptors leads to disease. This Perspective is focused on the nucleotides and dinucleotides and the P2 purinergic receptors in the eye and how they contribute to normal and disease states. We also emphasize the action of nucleotides and their receptors and antagonists as potential therapeutic agents.


Asunto(s)
Oftalmopatías/tratamiento farmacológico , Nucleótidos/fisiología , Fenómenos Fisiológicos Oculares , Animales , Humor Acuoso/metabolismo , Movimiento Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Ojo/inmunología , Oftalmopatías/metabolismo , Humanos , Nucleótidos/metabolismo , Nucleósidos de Purina/metabolismo , Nucleósidos de Purina/fisiología , Nucleótidos de Purina/metabolismo , Nucleótidos de Purina/fisiología , Retina/efectos de los fármacos , Retina/metabolismo , Epitelio Pigmentado de la Retina/metabolismo , Epitelio Pigmentado de la Retina/fisiología , Lágrimas/química , Lágrimas/metabolismo , Cicatrización de Heridas/efectos de los fármacos
10.
J Pharmacol Exp Ther ; 346(1): 138-45, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23591996

RESUMEN

Melatonin is currently considered a promising drug for glaucoma treatment because of its ocular hypotensive and neuroprotective effects. We have investigated the effect of melatonin and its analog 5-methoxycarbonylamino-N-acetyltryptamine, 5-MCA-NAT, on ß2/α(2A)-adrenergic receptor mRNA as well as protein expression in cultured rabbit nonpigmented ciliary epithelial cells. Quantitative polymerase chain reaction and immunocytochemical assays revealed a significant ß2-adrenergic receptor downregulation as well as α(2A)-adrenergic receptor up-regulation of treated cells (P < 0.001, maximal significant effect). In addition, we have studied the effect of these drugs upon the ocular hypotensive action of a nonselective ß-adrenergic receptor (timolol) and a selective α2-adrenergic receptor agonist (brimonidine) in normotensive rabbits. Intraocular pressure (IOP) experiments showed that the administration of timolol in rabbits pretreated with melatonin or 5-MCA-NAT evoked an additional IOP reduction of 14.02% ± 5.8% or 16.75% ± 5.48% (P < 0.01) in comparison with rabbits treated with timolol alone for 24 hours. Concerning brimonidine hypotensive action, an additional IOP reduction of 29.26% ± 5.21% or 39.07% ± 5.81% (P < 0.001) was observed in rabbits pretreated with melatonin or 5-MCA-NAT when compared with animals treated with brimonidine alone for 24 hours. Additionally, a sustained potentiating effect of a single dose of 5-MCA-NAT was seen in rabbits treated with brimonidine once daily for up 4 days (extra IOP decrease of 15.57% ± 5.15%, P < 0.05, compared with brimonidine alone). These data confirm the indirect action of melatoninergic compounds on adrenergic receptors and their remarkable effect upon the ocular hypotensive action mainly of α2-adrenergic receptor agonists but also of ß-adrenergic antagonists.


Asunto(s)
Agonistas Adrenérgicos/farmacología , Presión Intraocular/efectos de los fármacos , Melatonina/farmacología , Fármacos Neuroprotectores/farmacología , Receptores Adrenérgicos alfa 2/metabolismo , Receptores Adrenérgicos beta 2/metabolismo , Triptaminas/farmacología , Agonistas Adrenérgicos/efectos adversos , Agonistas Adrenérgicos/uso terapéutico , Agonistas de Receptores Adrenérgicos alfa 2/química , Agonistas de Receptores Adrenérgicos alfa 2/farmacología , Agonistas de Receptores Adrenérgicos alfa 2/uso terapéutico , Antagonistas Adrenérgicos beta/química , Antagonistas Adrenérgicos beta/farmacología , Antagonistas Adrenérgicos beta/uso terapéutico , Animales , Células Cultivadas , Cuerpo Ciliar/citología , Cuerpo Ciliar/efectos de los fármacos , Cuerpo Ciliar/metabolismo , Sinergismo Farmacológico , Células Epiteliales/metabolismo , Regulación de la Expresión Génica/efectos de los fármacos , Glaucoma/tratamiento farmacológico , Glaucoma/fisiopatología , Masculino , Melatonina/efectos adversos , Melatonina/análogos & derivados , Melatonina/uso terapéutico , Proteínas del Tejido Nervioso/agonistas , Proteínas del Tejido Nervioso/antagonistas & inhibidores , Proteínas del Tejido Nervioso/genética , Proteínas del Tejido Nervioso/metabolismo , Fármacos Neuroprotectores/efectos adversos , Fármacos Neuroprotectores/uso terapéutico , Hipotensión Ocular/inducido químicamente , Soluciones Oftálmicas/farmacología , Conejos , Receptores Adrenérgicos alfa 2/química , Receptores Adrenérgicos alfa 2/genética , Receptores Adrenérgicos beta 2/química , Receptores Adrenérgicos beta 2/genética , Triptaminas/efectos adversos , Triptaminas/uso terapéutico
11.
Biomedicines ; 11(2)2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36830827

RESUMEN

The eye is a metabolically active structure, constantly exposed to solar radiations making its structure vulnerable to the high burden of reactive oxygen species (ROS), presenting many molecular interactions. The biomolecular cascade modification is caused especially in diseases of the ocular surface, cornea, conjunctiva, uvea, and lens. In fact, the injury in the anterior segment of the eye takes its origin from the perturbation of the pro-oxidant/antioxidant balance and leads to increased oxidative damage, especially when the first line of antioxidant defence weakens with age. Furthermore, oxidative stress is related to mitochondrial dysfunction, DNA damage, lipid peroxidation, protein modification, apoptosis, and inflammation, which are involved in anterior ocular disease progression such as dry eye, keratoconus, uveitis, and cataract. The different pathologies are interconnected through various mechanisms such as inflammation, oxidative stress making the diagnostics more relevant in early stages. The end point of the molecular pathway is the release of different antioxidant biomarkers offering the potential of predictive diagnostics of the pathology. In this review, we have analysed the oxidative stress and inflammatory processes in the front of the eye to provide a better understanding of the pathomechanism, the importance of biomarkers for the diagnosis of eye diseases, and the recent treatment of anterior ocular diseases.

12.
Exp Eye Res ; 101: 49-55, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22677090

RESUMEN

The ability of diinosine polyphosphates, diinosine triphosphate (Ip(3)I), diinosine tetraphosphate (Ip(4)I) and diinosine pentaphosphate (Ip(5)I) to modify intraocular pressure in normotensive New Zealand white rabbits was tested. Ip(5)I produced increase in intraocular pressure, while Ip(3)I and Ip(4)I produced a decrease. Ip(4)I was the most effective reducing intraocular pressure inducing a maximal decrease of intraocular pressure to 74.2 ± 2.5% compared with the control value. Dose-response analysis demonstrated a concentration dependent pattern which presented a pD(2) value of 6.19 ± 0.18, equivalent to an EC(50) of 0.63 µM. Regarding the underlying mechanism used by Ip(4)I to reduce intraocular pressure, studies with agonists and antagonists revealed that Ip(4)I reduces intraocular pressure via P2Y receptors in the eye. We suggest that topical application of Ip(4)I to the cornea has therapeutic potential for lowering intraocular pressure, a major risk factor for glaucoma.


Asunto(s)
Fosfatos de Dinucleósidos/farmacología , Inosina/análogos & derivados , Presión Intraocular/efectos de los fármacos , Animales , Línea Celular , Cromatografía Líquida de Alta Presión , Relación Dosis-Respuesta a Droga , Masculino , Conejos , Receptores Purinérgicos P2Y/metabolismo , Tonometría Ocular
13.
J Pineal Res ; 52(3): 265-70, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22107075

RESUMEN

We have previously demonstrated that melatonin and its analogue, 5-methoxycarbonylamino-N-acetyltryptamine (5-MCA-NAT), reduce intraocular pressure (IOP) in New Zealand rabbits. More recently, we have shown that 5-MCA-NAT can also regulate ciliary adrenoceptor gene expression. Like adrenoceptors, carbonic anhydrase (CA) enzymes are involved in aqueous humour secretion by the ocular ciliary epithelium. Moreover, CA enzymes have been reported to be regulated by melatonin. Hence, the aim of this study was to investigate whether the hypotensive effect of 5-MCA-NAT is also because of a regulation of CA genes and enzymes. Time course of 5-MCA-NAT effect on rabbit IOP was followed for 7 hr every day for up to 144 hr (6 days). 5-MCA-NAT reduced IOP, maximally by 51.30 ± 2.41% (at 3 hr), and the hypotensive effect was maintained for up to 96 hr with a single application. IOP studies with 5-MCA-NAT plus Trusopt(®) and immunohistochemical analysis confirmed that CA are molecular targets of 5-MCA-NAT. In addition, real-time quantitative PCR (qPCR) and immunocytochemical assays were performed to determine changes in CA2 (CAII) and CA12 (CAXII) expression in cultured rabbit nonpigmented ciliary epithelial cells (NPE) treated with 5-MCA-NAT. NPE cells showed a prominent decrease in both CA, at the mRNA and protein levels. These data confirm that the long-term hypotensive effect of 5-MCA-NAT is also due, to a down-regulation of CA2 (CAII) and CA12 (CAXII) expression.


Asunto(s)
Anhidrasas Carbónicas/metabolismo , Hipertensión Ocular/tratamiento farmacológico , Triptaminas/uso terapéutico , Animales , Secuencia de Bases , Cartilla de ADN , Inmunohistoquímica , Presión Intraocular/efectos de los fármacos , Hipertensión Ocular/enzimología , Conejos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Triptaminas/farmacología
14.
Artículo en Inglés | MEDLINE | ID: mdl-35409575

RESUMEN

(1) Background: The purpose of this study was to evaluate the efficacy in terms of sensitivity, specificity, and accuracy of the quantusSKIN system, a new clinical tool based on deep learning, to distinguish between benign skin lesions and melanoma in a hospital population. (2) Methods: A retrospective study was performed using 232 dermoscopic images from the clinical database of the Ramón y Cajal University Hospital (Madrid, Spain). The skin lesions images, previously diagnosed as nevus (n = 177) or melanoma (n = 55), were analyzed by the quantusSKIN system, which offers a probabilistic percentage (diagnostic threshold) for melanoma diagnosis. The optimum diagnostic threshold, sensitivity, specificity, and accuracy of the quantusSKIN system to diagnose melanoma were quantified. (3) Results: The mean diagnostic threshold was statistically lower (p < 0.001) in the nevus group (27.12 ± 35.44%) compared with the melanoma group (72.50 ± 34.03%). The area under the ROC curve was 0.813. For a diagnostic threshold of 67.33%, a sensitivity of 0.691, a specificity of 0.802, and an accuracy of 0.776 were obtained. (4) Conclusions: The quantusSKIN system is proposed as a useful screening tool for melanoma detection to be incorporated in primary health care systems.


Asunto(s)
Aprendizaje Profundo , Melanoma , Nevo , Enfermedades de la Piel , Neoplasias Cutáneas , Dermoscopía/métodos , Hospitales , Humanos , Melanoma/diagnóstico por imagen , Redes Neurales de la Computación , Nevo/patología , Estudios Retrospectivos , Neoplasias Cutáneas/diagnóstico por imagen
15.
Biomolecules ; 11(3)2021 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-33668357

RESUMEN

Circadian rhythm and the molecules involved in it, such as melanopsin and melatonin, play an important role in the eye to regulate the homeostasis and even to treat some ocular conditions. As a result, many ocular pathologies like dry eye, corneal wound healing, cataracts, myopia, retinal diseases, and glaucoma are affected by this cycle. This review will summarize the current scientific literature about the influence of circadian patterns on the eye, focusing on its relationship with increased intraocular pressure (IOP) fluctuations and glaucoma. Regarding treatments, two ways should be studied: the first one, to analyze if some treatments could improve their effect on the ocular disease when their posology is established in function of circadian patterns, and the second one, to evaluate new drugs to treat eye pathologies related to the circadian rhythm, as it has been stated with melatonin or its analogs, that not only could be used as the main treatment but as coadjutant, improving the circadian pattern or its antioxidant and antiangiogenic properties.


Asunto(s)
Ritmo Circadiano/fisiología , Glaucoma/fisiopatología , Animales , Síndromes de Ojo Seco/fisiopatología , Glaucoma/metabolismo , Humanos , Presión Intraocular/fisiología , Melatonina/metabolismo , Miopía/metabolismo , Miopía/fisiopatología
16.
Pharmaceutics ; 13(9)2021 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-34575451

RESUMEN

Most irreversible blindness observed with glaucoma and retina-related ocular diseases, including age-related macular degeneration and diabetic retinopathy, have their origin in the posterior segment of the eye, making their physiopathology both complex and interconnected. In addition to the age factor, these diseases share the same mechanism disorder based essentially on oxidative stress. In this context, the imbalance between the production of reactive oxygen species (ROS) mainly by mitochondria and their elimination by protective mechanisms leads to chronic inflammation. Oxidative stress and inflammation share a close pathophysiological process, appearing simultaneously and suggesting a relationship between both mechanisms. The biochemical end point of these two biological alarming systems is the release of different biomarkers that can be used in the diagnosis. Furthermore, oxidative stress, initiating in the vulnerable tissue of the posterior segment, is closely related to mitochondrial dysfunction, apoptosis, autophagy dysfunction, and inflammation, which are involved in each disease progression. In this review, we have analyzed (1) the oxidative stress and inflammatory processes in the back of the eye, (2) the importance of biomarkers, detected in systemic or ocular fluids, for the diagnosis of eye diseases based on recent studies, and (3) the treatment of posterior ocular diseases, based on long-term clinical studies.

17.
Curr Eye Res ; 42(4): 513-519, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27450910

RESUMEN

PURPOSE: Based on the relationship between keratoconus and dry eye, the aim of this study was to evaluate changes in signs and symptoms of dry eye in keratoconus patients before and after intrastromal corneal ring surgery. METHODS: Fifteen keratoconus patients were enrolled in Fundación Jiménez-Díaz of Madrid and University Clinic of Optometry of the Universidad Complutense de Madrid (Madrid, Spain). Tear break up time (TBUT), Schirmer test without anesthesia, corneal staining, diadenosine tetraphosphate (Ap4A) concentration, and ocular surface disease index (OSDI) were evaluated. Impression cytology combined with laser confocal microscopy was performed to evaluate goblet cell density, mucin cloud height (MCH), and cell layer thickness (CLT). All measurements were performed before (pre) surgery, 1 month (post) and 6 months after surgery (post6m). RESULTS: We found no statistical differences in time in Schirmer test, TBUT, and corneal staining. OSDI scores were 44.96 ± 8.65, 26.30 ± 6.79, and 19.31 ± 4.28 for (pre), (post), and (post6m) surgery, respectively (p < 0.001). Impression cytology showed a decrease in cell density at (post6m) compared with presurgery (47.36 ± 35.15 cells/mm2 and 84.88 ± 32.08 cells/mm2, respectively, p = 0.04). At post6m, the MCH increased compared with presurgery values (13.97 ± 4.26 µm and 6.77 ± 2.51 µm, respectively, p < 0.001). There was a statistically significant increase in CLT in time. Ap4A tear concentrations were lower post6m than presurgery (1.02 ± 0.65 and 2.56 ± 1.10 µM, respectively, p < 0.001). CONCLUSION: Intrastromal corneal ring surgery induces changes improving dry eye symptoms but no changes were found in signs of dry eye after surgery in keratoconus patients except for the MCH that increases drastically. More studies are needed to clarify the reason of its improvement.


Asunto(s)
Sustancia Propia/cirugía , Síndromes de Ojo Seco/diagnóstico , Queratocono/diagnóstico , Queratocono/cirugía , Procedimientos Quirúrgicos Oftalmológicos , Implantación de Prótesis , Adolescente , Adulto , Recuento de Células , Fosfatos de Dinucleósidos/metabolismo , Síndromes de Ojo Seco/metabolismo , Femenino , Células Caliciformes/metabolismo , Células Caliciformes/patología , Humanos , Masculino , Microscopía Confocal , Estudios Prospectivos , Prótesis e Implantes , Lágrimas/química , Adulto Joven
18.
Clin Exp Optom ; 100(6): 577-582, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28125853

RESUMEN

BACKGROUND: The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. METHODS: Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. RESULTS: A significant increase of turbidity was found in all groups assessed (p < 0.05). The number of particles per square millimetre was eight times higher after scleral lens wear than at the beginning of wearing the lens for all groups. VA decreases in all groups after scleral lens wear (p < 0.001). All patients showed a statistical diminishing of contrast sensitivity after scleral lens wear (p < 0.05). A significant correlation was found for both turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p < 0.05). CONCLUSION: The VA decrease during the scleral lens wearing, filled with preserved saline solution, was due to the increasing post-lens tear layer turbidity.


Asunto(s)
Lentes de Contacto , Queratocono/terapia , Esclerótica , Lágrimas/metabolismo , Agudeza Visual/fisiología , Adulto , Sensibilidad de Contraste/fisiología , Paquimetría Corneal , Femenino , Humanos , Queratocono/metabolismo , Queratocono/fisiopatología , Masculino , Persona de Mediana Edad , Nefelometría y Turbidimetría , Factores de Tiempo , Tomografía de Coherencia Óptica
19.
Cont Lens Anterior Eye ; 39(4): 266-9, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27085466

RESUMEN

OBJECTIVE: To evaluate the differences between goblet cell density (GCD) and symptomatology after one month of orthokeratology lens wear. METHODS: A pilot, short-term study was conducted. Twenty-two subjects (29.7±7.0 years old) participated voluntarily in the study. Subjects were divided into two groups: habitual silicone hydrogel contact lens wearers (SiHCLW) and new contact lens wearers (NCLW). Schirmer test, tear break up time (TBUT), Ocular Surface Disease Index (OSDI) questionnaire and conjunctival impression cytology. GCD, mucin cloud height (MCH) and cell layer thickness (CLT) were measured. All measurements were performed before orthokeratology fitting and one month after fitting to assess the evolution of the changes throughout this time. RESULTS: No differences in tear volume and TBUT between groups were found (p>0.05). However, the OSDI score was statistically better after one month of orthokeratology lens wear than the baseline for the SiHCLW group (p=0.03). Regarding the goblet cell analysis, no differences were found in CLT and MCH from the baseline visit to the one month visit for the SiHCLW compared with NCLW groups (p>0.05). At baseline, the GCD in the SiHCLW group were statistically lower than NCLW group (p<0.001). There was a significant increase in GCD after orthokeratology fitting from 121±140cell/mm(2) to 254±130cell/mm(2) (p<0.001) in the SiHCLW group. CONCLUSION: Orthokeratology improves the dry eye subject symptoms and GCD after one month of wearing in SiHCLW. These results suggest that orthokeratology could be considered a good alternative for silicone hydrogel contact lens discomfort and dryness.


Asunto(s)
Biopsia/métodos , Conjuntiva/patología , Lentes de Contacto/efectos adversos , Síndromes de Ojo Seco/patología , Células Caliciformes/patología , Procedimientos de Ortoqueratología/métodos , Adulto , Técnicas de Diagnóstico Oftalmológico , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/prevención & control , Femenino , Humanos , Masculino , Procedimientos de Ortoqueratología/efectos adversos , Procedimientos de Ortoqueratología/instrumentación , Proyectos Piloto , Lágrimas/citología , Resultado del Tratamiento
20.
Prog Retin Eye Res ; 55: 182-205, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27421962

RESUMEN

Dinucleoside polyphosphates comprises a group of dinucleotides formed by two nucleosides linked by a variable number of phosphates, abbreviated NpnN (where n represents the number of phosphates). These compounds are naturally occurring substances present in tears, aqueous humour and in the retina. As the consequence of their presence, these dinucleotides contribute to many ocular physiological processes. On the ocular surface, dinucleoside polyphosphates can stimulate tear secretion, mucin release from goblet cells and they help epithelial wound healing by accelerating cell migration rate. These dinucleotides can also stimulate the presence of proteins known to protect the ocular surface against microorganisms, such as lysozyme and lactoferrin. One of the latest discoveries is the ability of some dinucleotides to facilitate the paracellular way on the cornea, therefore allowing the delivery of compounds, such as antiglaucomatous ones, more easily within the eye. The compound Ap4A has been described being abnormally elevated in patient's tears suffering of dry eye, Sjogren syndrome, congenital aniridia, or after refractive surgery, suggesting this molecule as biomarker for dry eye condition. At the intraocular level, some diadenosine polyphosphates are abnormally elevated in glaucoma patients, and this can be related to the stimulation of a P2Y2 receptor that increases the chloride efflux and water movement in the ciliary epithelium. In the retina, the dinucleotide dCp4U, has been proven to be useful to help in the recovery of retinal detachments. Altogether, dinucleoside polyphosphates are a group of compounds which present relevant physiological actions but which also can perform promising therapeutic benefits.


Asunto(s)
Humor Acuoso/metabolismo , Córnea/metabolismo , Fosfatos de Dinucleósidos/fisiología , Lágrimas/química , Distribución Tisular/fisiología , Animales , Humanos , Sistemas de Mensajero Secundario
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda