Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Eur J Vasc Endovasc Surg ; 51(3): 380-5, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26818022

RESUMEN

OBJECTIVES: The aim was to evaluate the current results of aortic arch aneurysm repair using inner branched endografts performed in three high volume aortic endovascular centers and to compare them to the pioneering global experience with this technology. METHODS: Included patients underwent repair of aortic arch aneurysms >55 mm in diameter using inner branched endograft technology between April 2013 and November 2014. All patients were deemed unfit for open surgery. Inner branches were designed to perfuse the brachiocephalic trunk and the left common carotid artery in all cases. A left subclavian artery (LSA) revascularization was performed prior to the arch endovascular repair. Data were collected retrospectively in an electronic database. Parameters included length of procedure, fluoroscopy time, contrast volume, technical success, presence of endoleaks, early and late complications, and mortality. RESULTS: Twenty-seven patients were included in the study. Technical success was achieved in all cases. No patients died during the 30 day post-operative period. Early neurologic events included two major strokes (7.4%) and one minor stroke (3.7%). Transient spinal cord ischemia with full recovery was observed in two patients (7.4%). Four patients (14.8%) underwent early (<30 day) re-interventions; these were for an access complication, an ischemic limb and exploration of the left ventricle through a sternotomy in two patients. During follow up (median 12 months), one patient (3.7%) died from a remote thoraco-abdominal aneurysm rupture. There were three Type 2 endoleaks (11.1%). Two re-interventions (7.4%) were performed, one to treat a Type 2 endoleak and one to treat a septic false aneurysm. A significant decrease in overall mortality was observed when comparing patients from the early experience with patients from the current report. CONCLUSIONS: The early outcomes associated with this technology are favorable. Branched endografting of aortic arch aneurysms should be considered in patients unfit for open surgery.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Procedimientos Endovasculares/métodos , Injerto Vascular/métodos , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda