Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Transl Vis Sci Technol ; 11(10): 11, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36201201

RESUMEN

Purpose: The purpose of this study was to evaluate the diagnostic performance of retinal blood flow (RBF) measured with the Doppler optical coherence tomography (OCT) segmental scanning method to distinguish between healthy and glaucoma eyes. Methods: Fifty-eight patients with normal tension glaucoma (NTG) who had a single-hemifield visual field defect and 44 age-matched healthy subjects were enrolled. Retinal nerve fiber layer thickness (RNFLT) was measured with swept-source OCT. Superior and inferior temporal arteries (TAs) and temporal veins (TVs) RBF were measured with Doppler OCT. The area under the curve (AUC) of the receiver operating characteristic (ROC) was used to compare the diagnostic performances in the damaged and normal hemispheres. Results: Multivariate regression analysis showed TA RBF and TV RBF were significantly reduced in the damaged and normal hemispheres. The ROC analysis showed that the AUC for quadrant RNFLT, TA RBF, and TV RBF were 0.973, 0.909, and 0.872 in the damaged hemisphere, respectively. The AUC values in the normal hemisphere were 0.783, 0.744, and 0.697, respectively. The combination of quadrant RNFLT and TA/TV RBF had a greater AUC than quadrant RNFLT alone in both damaged (AUC = 0.987) and normal (AUC = 0.825) hemispheres. Conclusions: In NTG eyes with single-hemifield damage, the RBF was found to be significantly reduced in the damaged and normal hemispheres independent from structural changes. The combination of RNFLT and RBF could improve diagnostic performances for glaucoma. Translational Relevance: Combining morphological and blood flow measurements with Doppler OCT may be useful in glaucoma diagnosis.


Asunto(s)
Glaucoma , Glaucoma de Baja Tensión , Glaucoma/diagnóstico por imagen , Humanos , Glaucoma de Baja Tensión/diagnóstico por imagen , Fibras Nerviosas , Retina , Células Ganglionares de la Retina , Tomografía de Coherencia Óptica/métodos
2.
Transl Vis Sci Technol ; 10(13): 25, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34792557

RESUMEN

Purpose: We aimed to explore the velocity waveform characteristics of the retinal artery associated with age and the cardio-ankle vascular index (CAVI) as a conventional arterial stiffness marker by applying the Doppler optical coherence tomography (DOCT) flowmeter. Methods: In this cross-sectional study, DOCT flowmeter imaging was performed in 66 participants aged 21 to 83 years (17 men, 49 women) with no history of eye diseases and no systemic diseases, except for hypertension. Retinal blood velocity waveform was analyzed where several parameters in time (upstroke time, T1, T2, T3, and T4) and area under the waveform (area elevation, area declination, A1, A2, A3, and A4) were extracted. Systolic blood pressure-adjusted Pearson's coefficients were calculated to determine the correlations of each parameter with age or CAVI. Results: Corrected upstroke time (UTc) was the waveform parameter most positively correlated with age (r = 0.497, P < 0.001). Area declination was the waveform parameter most negatively correlated with age (r = -0.682, P < 0.001) and CAVI (r = -0.601, P < 0.001). Conclusions: We extracted the waveform parameters associated with the risks of arterial stiffening. The velocity waveform analysis of the retinal artery with DOCT flowmeter potentially could become a new method for arterial stiffness identification. Translational Relevance: DOCT flowmeter could evaluate arterial stiffening in a different way from the conventional method of measuring arterial stiffening using pressure waveform. Because the DOCT flowmeter can easily, quickly, and noninvasively provide a retinal blood velocity waveform, this system could be useful as a routine medical examination for arterial stiffening.


Asunto(s)
Índice Vascular Cardio-Tobillo , Hipertensión , Envejecimiento , Presión Sanguínea , Estudios Transversales , Femenino , Humanos , Masculino
3.
Sci Rep ; 10(1): 14639, 2020 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-32901054

RESUMEN

The physiological stresses that diminish tissue stem-cell characteristics remain largely unknown. We previously reported that type I interferon (IFN), which is essential for host antiviral responses, is a physiological stressor for hematopoietic stem cells (HSCs) and small intestinal stem cells (ISCs) and that interferon regulatory factor-2 (IRF2), which attenuates IFN signaling, maintains their stemness. Here, using a dextran sodium sulfate (DSS)-induced colitis model, we explore the role of IRF2 in maintaining colonic epithelial stem cells (CoSCs). In mice with a conditional Irf2 deletion in the intestinal epithelium (hereafter Irf2ΔIEC mice), both the number and the organoid-forming potential of CoSCs were markedly reduced. Consistent with this finding, the ability of Irf2ΔIEC mice to regenerate colon epithelium after inducing colitis was severely impaired, independently of microbial dysbiosis. Mechanistically, CoSCs differentiated prematurely into transit-amplifying (TA) cells in Irf2ΔIEC mice, which might explain their low CoSC counts. A similar phenotype was induced in wild-type mice by repeated injections of low doses of poly(I:C), which induces type I IFN. Collectively, we demonstrated that chronic IFN signaling physiologically stresses CoSCs. This study provides new insight into the development of colitis and molecular mechanisms that maintain functional CoSCs throughout life.


Asunto(s)
Autorrenovación de las Células , Colitis Ulcerosa/metabolismo , Factor 2 Regulador del Interferón/metabolismo , Interferones/metabolismo , Mucosa Intestinal/metabolismo , Células Madre/metabolismo , Estrés Fisiológico , Animales , Células Cultivadas , Colitis Ulcerosa/patología , Colon/metabolismo , Colon/patología , Factor 2 Regulador del Interferón/genética , Mucosa Intestinal/citología , Mucosa Intestinal/patología , Ratones , Ratones Endogámicos C57BL , Células Madre/fisiología
4.
Transl Vis Sci Technol ; 8(3): 13, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31110914

RESUMEN

PURPOSE: To evaluate the repeatability and reproducibility of the measurement of retinal arteriole pulse waveforms using a novel fully-automated Doppler optical coherence tomography (DOCT) flowmeter in healthy subjects. METHODS: Twenty eyes of 20 healthy subjects were included to test the intrasession repeatability of pulse waveform analysis. DOCT measurements were performed based on a newly developed instantaneous Doppler angle measurement method. Upstroke time (UT), which is the time from the minimum to the maximum retinal blood velocity, and the resistance index (RI) of the retinal arteriole pulse waveform were measured. Coefficients of variation (CVs) and intraclass correlation coefficients (ICCs) were calculated. Interdevice reproducibility between two instruments was assessed in five eyes of five subjects. RESULTS: The mean UT was 130.3 ms (range, 110.1-152.1 ms), and the mean RI was 0.66 (range, 0.51-0.82). The respective ICCs of UT and the RI for the intrasession repeatability of assessment were 0.87 and 0.78. The respective CVs of UT and the RI were 6.6 ± 3.3% and 4.7 ± 2.1%. Regarding interdevice reproducibility, there were no significant differences between the measurements derived from the instruments (P > 0.05). CONCLUSIONS: Pulse waveform measurement in retinal arterioles using a fully-automated DOCT flowmeter exhibited good repeatability and interdevice reproducibility. TRANSLATIONAL RELEVANCE: The above-described improved DOCT flowmeter system provides reasonably repeatable measurements of retinal arteriole pulse waveforms, potentially facilitating systemic-circulation abnormality monitoring. The examination of the circulation with the novel device can be potentially useful for evaluating systemic circulation.

5.
J Vet Med Sci ; 76(11): 1501-4, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25077664

RESUMEN

Scratching and skin barrier dysfunctions are pivotal features and therapeutic targets of atopic dermatitis (AD); however, time-of-day-dependent variations of these characteristics remain unclear. NC/Tnd mice have been shown to exhibit severe scratching behavior and skin barrier disruption together with the development of spontaneous atopic dermatitis when they are raised under air-uncontrolled environment. In the present study, time-of-day-dependent variations of scratching behavior and transepidermal water loss (TEWL) were evaluated in NC/Tnd mice that developed moderate to severe AD. Analysis of the mice for 24 hr revealed that scratching frequency and duration were increased from in the afternoon to the nocturnal period when locomotor activity was low, and scratching behavior was decreased in the morning. The highest scratching frequency and duration were 3.8- and 4.1-fold increases in the lowest scratching frequency and duration, respectively. In addition, TEWL on the dorsal skin lesion was decreased in the diurnal period, while that was increased in the nocturnal period. The highest TEWL was a 1.3-fold increase in the lowest TEWL. Significant daily variations were detected in scratching frequency and duration and TEWL. These results indicate that NC/Tnd mice are an appropriate mouse model to investigate time-of-day-dependent variations of scratching behavior and skin barrier dysfunctions associated with AD.


Asunto(s)
Ritmo Circadiano/fisiología , Dermatitis Atópica/fisiopatología , Pérdida Insensible de Agua/fisiología , Análisis de Varianza , Animales , Conducta Animal/fisiología , Femenino , Locomoción/fisiología , Masculino , Ratones , Ratones Endogámicos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda